This paper presents a method for optimizing a grid-connected photovoltaic system through an LCL filter. An algorithm based on particle swarm optimization (PSO) is used to determine the number of batteries, the number ...This paper presents a method for optimizing a grid-connected photovoltaic system through an LCL filter. An algorithm based on particle swarm optimization (PSO) is used to determine the number of batteries, the number of panels in series and in parallel, as well as to evaluate the joule losses due to cable heating and the switching losses of the multilevel inverters. This system is applied to a village named YAGOUA, located in the far north of Cameroon. The evaluation of the Joule effect and the switching losses as well as the regulation of the voltage level at the point of common coupling (PCC) are carried out in PVsyst and Matlab software, then at IEEE 33 bus. This algorithm reduced the Joule losses to 1.2% and the switching losses to 2.2%. A power of 210.4 MWh is produced, to be injected in the electrical network via an LCL filter. The THD calculation gave a rate of 3.015% in accordance with the 519 standards. Synchronization through the Phase Locked Loop (PLL) is performed. After the power was injected into the grid, the voltage and current remained in phase, showing the power factor correction and the efficiency of the filter. According to NASA meteorological data, the locality of YAGOUA gives the global solar irradiation forecast of 6.8 kW/m2.展开更多
The integration of distributed generations (DGs) into distribution systems (DSs) is increasingly becoming a solution for compensating for isolated local energy systems (ILESs). Additionally, distributed generations ar...The integration of distributed generations (DGs) into distribution systems (DSs) is increasingly becoming a solution for compensating for isolated local energy systems (ILESs). Additionally, distributed generations are used for self-consumption with excess energy injected into centralized grids (CGs). However, the improper sizing of renewable energy systems (RESs) exposes the entire system to power losses. This work presents an optimization of a system consisting of distributed generations. Firstly, PSO algorithms evaluate the size of the entire system on the IEEE bus 14 test standard. Secondly, the size of the system is allocated using improved Particles Swarm Optimization (IPSO). The convergence speed of the objective function enables a conjecture to be made about the robustness of the proposed system. The power and voltage profile on the IEEE 14-bus standard displays a decrease in power losses and an appropriate response to energy demands (EDs), validating the proposed method.展开更多
The classical minimization of power losses in transmission lines is dominated by artificial intelligence techniques, which do not guarantee global optimum amidst local minima. Revolutionary and evolutionary techniques...The classical minimization of power losses in transmission lines is dominated by artificial intelligence techniques, which do not guarantee global optimum amidst local minima. Revolutionary and evolutionary techniques are encumbered with sophisticated transformations, which weaken the techniques. Power loss minimization is crucial to the efficient design and operation of power transmission lines. Minimization of losses is one way to meet steady grid supply, especially at peak demand. Thus, this paper has presented a gradient technique to obtain optimal variables and values from the power loss model, which efficiently minimizes power losses by modifying the traditional power loss model that combines Ohm and Corona losses. Optimality tests showed that the unmodified model does not support the minimization of power losses on transmission lines as the Hessian matrix portrayed the maximization of power losses. However, the modified model is consistent with the gradient method of optimization, which yielded optimum variables and values from the power loss model developed in this study. The unmodified (modified) models for Bujagali-Kawanda 220 kV and Masaka West-Mbarara North 132 kV transmission lines in Uganda showed maximum power losses of 0.406 (0.391) and 0.452 (0.446) kW/km/phase respectively. These results indicate that the modified model is superior to the unmodified model in minimizing power losses in the transmission lines and should be implemented for the efficient design and operation of power transmission lines within and outside Uganda for the same transmission voltages.展开更多
According to the dimensional tolerances on hydrodynamic journal bearing system, a nonlinear oil film force model was established,and the Reynolds' equation was solved by adopting finite difference method. In order...According to the dimensional tolerances on hydrodynamic journal bearing system, a nonlinear oil film force model was established,and the Reynolds' equation was solved by adopting finite difference method. In order to fulfill different dimensional tolerances in the system,adopting 2kfactor design and using the eccentricity ratio corresponding to the stability critical curve,the effects of the friction power loss brought by the dimensional tolerances of the dynamic viscosity,bearing width,bearing diameter and journal diameter were analyzed. The effect on dynamic characteristics of the hydrodynamic journal bearing system was quantitatively analyzed,and the nonlinear dynamic analysis, modeling and calculation methods were studied while considering the manufacturing tolerances. The results show that in contrast to the impacts of the tolerances in journal diameter,dynamic viscosity and bearing width,the bearing diameter tolerance would lead to the rise in the power loss, and the dimensional tolerances have different degrees of impacts on the journal bearing system. The friction power loss decreased as the eccentricity ratio increased, and when the eccentricity ratio was 0. 695 the power loss came to the minimum.The investigation would find the best solution and reduce energy consumption,then control varieties of nonlinear dynamical behavior effectively,and provide a theoretical basis for hydrodynamic journal bearing system in parameter design.展开更多
Effect of the content of dopants in the manganese-zinc ferrites on the low power loss is studied by measuring magnetic properties and observing the grain boundary structures. The Mn0.738Zn0.206Fe2.066O4 composition po...Effect of the content of dopants in the manganese-zinc ferrites on the low power loss is studied by measuring magnetic properties and observing the grain boundary structures. The Mn0.738Zn0.206Fe2.066O4 composition powders were prepared by using conventional ceramic powder processing technique. The microstructure of grain boundary was observed by scanning electron microscope (SEM). It has been found that power loss is greatly dependent upon the content of the additives.展开更多
The dependences of the power loss per cycle on frequency f and amplitude flux density Bm have been investigated for the three main original magnetic states in five sorts of Fe-based nanocrystalline soft magnetic alloy...The dependences of the power loss per cycle on frequency f and amplitude flux density Bm have been investigated for the three main original magnetic states in five sorts of Fe-based nanocrystalline soft magnetic alloys in the ranges of 10 Hz<=f<=1000 Hz and 0.4 T<= Bm <=1.0 T. The total loss P is decomposed into the sum of the hysteresis loss Physt, the classical eddy current loss Pel and the excess loss Pexc. Physt has been found to be proportional to Bm^2 and f. The behavior of Pexc/f vs f being equivalent to P/f vs f clearly exhibits nonlinearity in the range not more than about 120 Hz, whereas the behavior of P/f vs f roughly shows linearity in the range far above 100 Hz and not more than 1000 Hz. In the range up to 1000 Hz, Physt is dominant in the original high permeability state and the state of low residual flux density, whereas Pexc in the state of high residual flux density is dominant in the wider range above about 100 Hz. The framework of the statistical theory of power loss has been used for representing the behavior of Pexc/f vs f. It has been found that the number n of the simultaneously active 'Magnetic Objects' linearly varies as n = n0 + Hexc/H0 as a function of the dynamic field Hexc in the range below about 120 Hz, whereas n approximately follows a law of the form n = n0 + (Hexc/H0)^m with 1 < m < 2 in the range far above 100 Hz and not more than 1000 Hz. The values of the field HO in principle related to the microstructure and the domain structure have been calculated for the three states.展开更多
The aim of this paper is to determine the power losses recorded by a PV generator operating under partial shading conditions. These losses are evaluated through two distinct methods. The first method is based on mathe...The aim of this paper is to determine the power losses recorded by a PV generator operating under partial shading conditions. These losses are evaluated through two distinct methods. The first method is based on mathematical modeling, while the second is based on Simulink’s physical model. The losses recorded are considerable and increase as a function of the increase in the percentage of shading up to a limit value where they become constant in the case where an ideal by-pass diode is connected in parallel with the modules. This limit value is non-existent in the case where the bypass diode is not ideal, which in fact corresponds to the real model. However, it emerges that the power losses are minimized in a PV system comprising bypass diodes, in particular in the case where the partial shading is considerable.展开更多
A type of silicon detector known as AXUV (absolute extreme ultraviolet) photodiodes is successfully used to measure the radiated power in EAST. The detector is characterized by compact structure, fast temporal respo...A type of silicon detector known as AXUV (absolute extreme ultraviolet) photodiodes is successfully used to measure the radiated power in EAST. The detector is characterized by compact structure, fast temporal response (〈0.5 s) and flat spectral sensitivity in the range from ultra-violet to X-ray. Two 16-channel AXUV arrays are installed in EAST to view the whole poloidal cross-section of plasma. Based on the diagnostic system, typical radiation distributions for both limiter and divertor plasma are obtained and compared. As divertor detachment occurs, the radiation distribution in X-point region is observed to vary distinctly. The total radiation power losses in discharges with different plasma parameters are briefly analyzed.展开更多
Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop f...Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop for different types of consumers.Reducing losses and improving voltage profiles in rural distribution networks are significant challenges for electricity distribution companies.However different solutions were proposed in the literature to overcome these challenges,most of them face difficulties when applied in the conventional distribution network.To address the above issues,an applicable solution is proposed in this paper by installing a number of small-capacity distribution transformers instead of every single large-capacity transformer in rural areas.The proposed approach is implemented in the branch network of Al-Hoqool village,which belongs to the Nineveh distribution network.The network has been inspected on-site,drawn,and analyzed using the electrical systems analysis program(ETAP).The analysis showed that using the single-phase pole-mounted transformers can improve the voltage in the network’s end by 29%and enhance the voltage profile for all consumers.The analysis has also demonstrated that the modification can reduce the total power losses by 78%compared to the existing network.Concerning the economic aspect,the payback period for the proposed network is assigned to be 20 months.展开更多
In this report,we show that hyperspectral high-resolution photoluminescence mapping is a powerful tool for the selection and optimiz1ation of the laser ablation processes used for the patterning interconnections of su...In this report,we show that hyperspectral high-resolution photoluminescence mapping is a powerful tool for the selection and optimiz1ation of the laser ablation processes used for the patterning interconnections of subcells on Cu(Inx,Ga1-x)Se2(CIGS)modules.In this way,we show that in-depth monitoring of material degradation in the vicinity of the ablation region and the identification of the underlying mechanisms can be accomplished.Specifically,by analyzing the standard P1 patterning line ablated before the CIGS deposition,we reveal an anomalous emission-quenching effect that follows the edge of the molybdenum groove underneath.We further rationalize the origins of this effect by comparing the topography of the P1 edge through a scanning electron microscope(SEM)cross-section,where a reduction of the photoemission cannot be explained by a thickness variation.We also investigate the laser-induced damage on P1 patterning lines performed after the deposition of CIGS.We then document,for the first time,the existence of a short-range damaged area,which is independent of the application of an optical aperture on the laser path.Our findings pave the way for a better understanding of P1-induced power losses and introduce new insights into the improvement of current strategies for industry-relevant module interconnection schemes.展开更多
The research reported in this paper focuses on non-technical power loss reduction for power distribution systems. Such reduction of costs of energy not served (ENS.COST), is intelligently evaluated and optimized using...The research reported in this paper focuses on non-technical power loss reduction for power distribution systems. Such reduction of costs of energy not served (ENS.COST), is intelligently evaluated and optimized using a firefly algorithm, from where savings of 43.3% on energy not served are achieved.展开更多
In the design of the CAT 3408 engine, the Low Temperature (BT) circuits used to cool the engine lubricating oil and the charge air and the High Temperature (HT) circuits for cooling the cylinder liners, cylinder heads...In the design of the CAT 3408 engine, the Low Temperature (BT) circuits used to cool the engine lubricating oil and the charge air and the High Temperature (HT) circuits for cooling the cylinder liners, cylinder heads and body of turbofans are mainly used to cool the engine, so that it works properly. This work, based on the analysis carried out, to determine the lubrication compliance of the Yacco VX 100 - SAE 15 W-40 oil and that of the Camwater water used in the engine of the Boat Yang 1 by carrying out a series of conventional tests such as that: the density, the viscosity, the viscosity index, the flash point, the density, the sulphate center content, the water content, the total acidity index (TAN), total basic number (TBN) and pour point for the oil case and pH, hardness, sodium chloride content [NaCl], sodium sulphate content [NaSO<sub>4</sub>] for the water case which will be compared to the specified requirements to determine whether compliance is achieved for each of these characteristics. The results of the oil and water samples taken from the engine after use show that the used oil gives a specific gravity of 0.8822, a viscosity (at 40°C) of 92.29 mm<sup>2</sup>/s, a viscosity (at 100°C) of 13.99 mm<sup>2</sup>/s, a viscosity index (VI) of 155.39, a pour point -21°C, a Flash Point (VO) 215°C, a Sulfated ash content of 18%, a density 881.5 kg/m<sup>3</sup>, a total basic number (TBN) of 12.60 mgKOH/g, a Total Acid Index (TAN) of 3.096 mgKOH/g, a Water Content of 1.8 % and the water used gives a pH of 6.00, a hardness of 3.2 french degrees, a sodium chloride content [NaCl] of 0.468 mg/L, and a calcium sulphate content [CaSO<sub>4</sub>] of 2.38345 mg/L. the results of the water content and content of sulfated centers justify the thermal overload and power losses in the marine diesel engine CAT 3408 of the boat Yang 1 because of their values which are not in conformity with the standards.展开更多
We present a theoretic model to calculate skin depths and eddy-current power losses for a magnetic position sensor. Eddy-current, arised from the operation of an alternating-current excitation, induces secondary curre...We present a theoretic model to calculate skin depths and eddy-current power losses for a magnetic position sensor. Eddy-current, arised from the operation of an alternating-current excitation, induces secondary currents and fields between magnetic material and magnetic position sensor. In this paper, a magnetic position sensor system is simplified to be an outer-winding coil along the axial direction of a low carbon steel bar. The analytical model is derived from basic field and circuit theory considering a linear approximation for a nonlinear permeability. Thus the skin depths and eddy-current power losses from the model in eddy-current modeling techniques at various frequencies of an excited current source can be calculated. The proposed configuration is capable of predicting the skin depths and eddy-current power losses for a magnetic position sensor and has a consistence with experiments.展开更多
This paper presents a powerful approach to find the optimal size and location of distributed generation units in a distribution system using GA (Genetic Optimization algorithm). It is proved that GA method is fast a...This paper presents a powerful approach to find the optimal size and location of distributed generation units in a distribution system using GA (Genetic Optimization algorithm). It is proved that GA method is fast and easy tool to enable the planners to select accurate and the optimum size of generators to improve the system voltage profile in addition to reduce the active and reactive power loss. GA fitness function is introduced including the active power losses, reactive power losses and the cumulative voltage deviation variables with selecting weight of each variable. GA fitness function is subjected to voltage constraints, active and reactive power losses constraints and DG size constraint.展开更多
Shanghai high-repetition-rate XFEL and extreme light facility (SHINE), the first hard XFEL based on a superconducting accelerated structure in China, is now under development at the Shanghai Institute of Applied Physi...Shanghai high-repetition-rate XFEL and extreme light facility (SHINE), the first hard XFEL based on a superconducting accelerated structure in China, is now under development at the Shanghai Institute of Applied Physics, Chinese Academy of Sciences. In this paper, power losses caused by trapped longitudinal high-order modes (HOM), steady-state loss, and transient loss generated by untrapped HOMs in the 1.3-GHz SHINE cryomodule are investigated and calculated. The heat load generated by resistive wall wakefields is considered as well. Results are presented for power losses of every element in the 1.3-GHz cryomodule, caused by HOM excitation in the acceleration RF system of the continuouswave linac of SHINE.展开更多
An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of succe...An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.展开更多
Harmonics in power systems is increasingly at high level. Also, there has been an incredible growth in the use of cross linked polyethylene (XLPE) cables in distribution systems. Harmonics cause additional power loss/...Harmonics in power systems is increasingly at high level. Also, there has been an incredible growth in the use of cross linked polyethylene (XLPE) cables in distribution systems. Harmonics cause additional power loss/temperature rise;causing premature failure of cables. Catastrophic failure of power cables leads to great inconvenience to consumers and loss of system reliability and money. To avoid the overheating of power cables;the additional power loss due to harmonics should be accurately calculated and properly accommodated by derating the cable. The present method of calculating the power loss in cables in harmonics rich environment is very arduous. The aim of this paper is to present the reasonably accurate method for evaluating effects of harmonics on the power loss in XLPE cables. Computational model is developed in MATLAB for power loss calculation using conventional method. Using this model, calculations are performed for aluminium and copper conductor XLPE cables of different size and type;for three different types of harmonics spectrums having total harmonics distortion (THD) of 30.68%, including all odd harmonics components up to 49th order. Using these results;a mathematical model in the form of simple empirical formula is developed by curve fitting technique. The results obtained by various models are presented and compared with error justification.展开更多
With the development of concentrated wind power areas, new energy’s dispatching problems are more prominent with its fast expansion. However, we can maximize the utilization of wind power under power curtailment cond...With the development of concentrated wind power areas, new energy’s dispatching problems are more prominent with its fast expansion. However, we can maximize the utilization of wind power under power curtailment conditions by optimal wind power dispatching. The paper studies on the basic theories of wind power turbines, and analyses the power’s control and output characteristics of wind turbine, which analyses the double-fed inductor generator’s excellent decoupling control of power and its excellent reactive power output capability. By studying the characteristics of wind power output, this paper provides a strategy for optimal dispatch in wind power generation. The calculation results show that the total active and reactive power output of the wind farm match the request of dispatch center. And the total active loss and total reactive loss is the least in the meantime.展开更多
Improving vehicle transmission efficiency and reducing vehicle fuel consumption is currently one of the main objectives in the automotive field. Reducing gear churning power losses has significant influence on the dec...Improving vehicle transmission efficiency and reducing vehicle fuel consumption is currently one of the main objectives in the automotive field. Reducing gear churning power losses has significant influence on the decreasing vehicle fuel consumption. Based on the two phase flow theory, a 2D two-phase model of the simplified hypoid gear is established to predict the churning losses in different conditions, the VOF method is introduced to track the volume fraction of the free surface, a standard k-ε model is also built to calculate complex turbulence. The oil distributions at the different rotational speed, the different immersion depth and the different viscosity as well as the churning losses of the hypoid gear are obtained and discussed in detail. In general, the churning power losses increase with the increase of the speed, the immersion depth and the viscosity, while the rotational speed shows the greatest influence on the churning losses. It is hoped that this investigation will be helpful in automotive industry applications.展开更多
Ideally,converter losses should be determined without using an excessive amount of simulation time.State-of-the-art power semiconductor models provide good accuracy,unfortunately they often require a very long simulat...Ideally,converter losses should be determined without using an excessive amount of simulation time.State-of-the-art power semiconductor models provide good accuracy,unfortunately they often require a very long simulation time.This paper describes how to estimate power losses from simulation using ideal switches combined with measured power loss data.The semiconductor behavior is put into a look-up table,which replaces the advanced semiconductor models and shortens the simulation time.To extract switching and conduction losses,a converter is simulated and the semiconductor power losses are estimated.Measurement results on a laboratory converter are compared with the estimated losses and a good agreement is shown.Using the ideal switch simulation and the post processing power estimation program,a ten to twenty fold increase in simulation speed is obtained,compared to simulations using advanced models of semiconductors.展开更多
文摘This paper presents a method for optimizing a grid-connected photovoltaic system through an LCL filter. An algorithm based on particle swarm optimization (PSO) is used to determine the number of batteries, the number of panels in series and in parallel, as well as to evaluate the joule losses due to cable heating and the switching losses of the multilevel inverters. This system is applied to a village named YAGOUA, located in the far north of Cameroon. The evaluation of the Joule effect and the switching losses as well as the regulation of the voltage level at the point of common coupling (PCC) are carried out in PVsyst and Matlab software, then at IEEE 33 bus. This algorithm reduced the Joule losses to 1.2% and the switching losses to 2.2%. A power of 210.4 MWh is produced, to be injected in the electrical network via an LCL filter. The THD calculation gave a rate of 3.015% in accordance with the 519 standards. Synchronization through the Phase Locked Loop (PLL) is performed. After the power was injected into the grid, the voltage and current remained in phase, showing the power factor correction and the efficiency of the filter. According to NASA meteorological data, the locality of YAGOUA gives the global solar irradiation forecast of 6.8 kW/m2.
文摘The integration of distributed generations (DGs) into distribution systems (DSs) is increasingly becoming a solution for compensating for isolated local energy systems (ILESs). Additionally, distributed generations are used for self-consumption with excess energy injected into centralized grids (CGs). However, the improper sizing of renewable energy systems (RESs) exposes the entire system to power losses. This work presents an optimization of a system consisting of distributed generations. Firstly, PSO algorithms evaluate the size of the entire system on the IEEE bus 14 test standard. Secondly, the size of the system is allocated using improved Particles Swarm Optimization (IPSO). The convergence speed of the objective function enables a conjecture to be made about the robustness of the proposed system. The power and voltage profile on the IEEE 14-bus standard displays a decrease in power losses and an appropriate response to energy demands (EDs), validating the proposed method.
文摘The classical minimization of power losses in transmission lines is dominated by artificial intelligence techniques, which do not guarantee global optimum amidst local minima. Revolutionary and evolutionary techniques are encumbered with sophisticated transformations, which weaken the techniques. Power loss minimization is crucial to the efficient design and operation of power transmission lines. Minimization of losses is one way to meet steady grid supply, especially at peak demand. Thus, this paper has presented a gradient technique to obtain optimal variables and values from the power loss model, which efficiently minimizes power losses by modifying the traditional power loss model that combines Ohm and Corona losses. Optimality tests showed that the unmodified model does not support the minimization of power losses on transmission lines as the Hessian matrix portrayed the maximization of power losses. However, the modified model is consistent with the gradient method of optimization, which yielded optimum variables and values from the power loss model developed in this study. The unmodified (modified) models for Bujagali-Kawanda 220 kV and Masaka West-Mbarara North 132 kV transmission lines in Uganda showed maximum power losses of 0.406 (0.391) and 0.452 (0.446) kW/km/phase respectively. These results indicate that the modified model is superior to the unmodified model in minimizing power losses in the transmission lines and should be implemented for the efficient design and operation of power transmission lines within and outside Uganda for the same transmission voltages.
基金National Natural Science Foundations of China(No.11272100,No.50865001)
文摘According to the dimensional tolerances on hydrodynamic journal bearing system, a nonlinear oil film force model was established,and the Reynolds' equation was solved by adopting finite difference method. In order to fulfill different dimensional tolerances in the system,adopting 2kfactor design and using the eccentricity ratio corresponding to the stability critical curve,the effects of the friction power loss brought by the dimensional tolerances of the dynamic viscosity,bearing width,bearing diameter and journal diameter were analyzed. The effect on dynamic characteristics of the hydrodynamic journal bearing system was quantitatively analyzed,and the nonlinear dynamic analysis, modeling and calculation methods were studied while considering the manufacturing tolerances. The results show that in contrast to the impacts of the tolerances in journal diameter,dynamic viscosity and bearing width,the bearing diameter tolerance would lead to the rise in the power loss, and the dimensional tolerances have different degrees of impacts on the journal bearing system. The friction power loss decreased as the eccentricity ratio increased, and when the eccentricity ratio was 0. 695 the power loss came to the minimum.The investigation would find the best solution and reduce energy consumption,then control varieties of nonlinear dynamical behavior effectively,and provide a theoretical basis for hydrodynamic journal bearing system in parameter design.
基金Project supported by National High-Technology Research and De-velopment Program(Grant No .2001AA3250380)
文摘Effect of the content of dopants in the manganese-zinc ferrites on the low power loss is studied by measuring magnetic properties and observing the grain boundary structures. The Mn0.738Zn0.206Fe2.066O4 composition powders were prepared by using conventional ceramic powder processing technique. The microstructure of grain boundary was observed by scanning electron microscope (SEM). It has been found that power loss is greatly dependent upon the content of the additives.
基金National Amorphous and Nanocrystalline Alloy Engineering Researeh Cease
文摘The dependences of the power loss per cycle on frequency f and amplitude flux density Bm have been investigated for the three main original magnetic states in five sorts of Fe-based nanocrystalline soft magnetic alloys in the ranges of 10 Hz<=f<=1000 Hz and 0.4 T<= Bm <=1.0 T. The total loss P is decomposed into the sum of the hysteresis loss Physt, the classical eddy current loss Pel and the excess loss Pexc. Physt has been found to be proportional to Bm^2 and f. The behavior of Pexc/f vs f being equivalent to P/f vs f clearly exhibits nonlinearity in the range not more than about 120 Hz, whereas the behavior of P/f vs f roughly shows linearity in the range far above 100 Hz and not more than 1000 Hz. In the range up to 1000 Hz, Physt is dominant in the original high permeability state and the state of low residual flux density, whereas Pexc in the state of high residual flux density is dominant in the wider range above about 100 Hz. The framework of the statistical theory of power loss has been used for representing the behavior of Pexc/f vs f. It has been found that the number n of the simultaneously active 'Magnetic Objects' linearly varies as n = n0 + Hexc/H0 as a function of the dynamic field Hexc in the range below about 120 Hz, whereas n approximately follows a law of the form n = n0 + (Hexc/H0)^m with 1 < m < 2 in the range far above 100 Hz and not more than 1000 Hz. The values of the field HO in principle related to the microstructure and the domain structure have been calculated for the three states.
文摘The aim of this paper is to determine the power losses recorded by a PV generator operating under partial shading conditions. These losses are evaluated through two distinct methods. The first method is based on mathematical modeling, while the second is based on Simulink’s physical model. The losses recorded are considerable and increase as a function of the increase in the percentage of shading up to a limit value where they become constant in the case where an ideal by-pass diode is connected in parallel with the modules. This limit value is non-existent in the case where the bypass diode is not ideal, which in fact corresponds to the real model. However, it emerges that the power losses are minimized in a PV system comprising bypass diodes, in particular in the case where the partial shading is considerable.
基金supported by National Natural Science Foundation of China (No. 10935004)National Magnetic Confinement Fusion Science Program of China (Nos. 2010GB106000, 2010GB106004)
文摘A type of silicon detector known as AXUV (absolute extreme ultraviolet) photodiodes is successfully used to measure the radiated power in EAST. The detector is characterized by compact structure, fast temporal response (〈0.5 s) and flat spectral sensitivity in the range from ultra-violet to X-ray. Two 16-channel AXUV arrays are installed in EAST to view the whole poloidal cross-section of plasma. Based on the diagnostic system, typical radiation distributions for both limiter and divertor plasma are obtained and compared. As divertor detachment occurs, the radiation distribution in X-point region is observed to vary distinctly. The total radiation power losses in discharges with different plasma parameters are briefly analyzed.
文摘Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop for different types of consumers.Reducing losses and improving voltage profiles in rural distribution networks are significant challenges for electricity distribution companies.However different solutions were proposed in the literature to overcome these challenges,most of them face difficulties when applied in the conventional distribution network.To address the above issues,an applicable solution is proposed in this paper by installing a number of small-capacity distribution transformers instead of every single large-capacity transformer in rural areas.The proposed approach is implemented in the branch network of Al-Hoqool village,which belongs to the Nineveh distribution network.The network has been inspected on-site,drawn,and analyzed using the electrical systems analysis program(ETAP).The analysis showed that using the single-phase pole-mounted transformers can improve the voltage in the network’s end by 29%and enhance the voltage profile for all consumers.The analysis has also demonstrated that the modification can reduce the total power losses by 78%compared to the existing network.Concerning the economic aspect,the payback period for the proposed network is assigned to be 20 months.
基金the DFG research training group GRK 1896 at Erlangen University and from the Joint Project Helmholtz-Institute Erlangen-Nürnberg(HI-ERN)for Renewable Energy Production under Project DBF01253,respectivelyfinancial support through the“Aufbruch Bayern”initiative of the state of Bavaria(EnCN and Solar Factory of the Future)and the“Solar Factory of the Future”with the Energy Campus Nürnberg(EnCN).
文摘In this report,we show that hyperspectral high-resolution photoluminescence mapping is a powerful tool for the selection and optimiz1ation of the laser ablation processes used for the patterning interconnections of subcells on Cu(Inx,Ga1-x)Se2(CIGS)modules.In this way,we show that in-depth monitoring of material degradation in the vicinity of the ablation region and the identification of the underlying mechanisms can be accomplished.Specifically,by analyzing the standard P1 patterning line ablated before the CIGS deposition,we reveal an anomalous emission-quenching effect that follows the edge of the molybdenum groove underneath.We further rationalize the origins of this effect by comparing the topography of the P1 edge through a scanning electron microscope(SEM)cross-section,where a reduction of the photoemission cannot be explained by a thickness variation.We also investigate the laser-induced damage on P1 patterning lines performed after the deposition of CIGS.We then document,for the first time,the existence of a short-range damaged area,which is independent of the application of an optical aperture on the laser path.Our findings pave the way for a better understanding of P1-induced power losses and introduce new insights into the improvement of current strategies for industry-relevant module interconnection schemes.
文摘The research reported in this paper focuses on non-technical power loss reduction for power distribution systems. Such reduction of costs of energy not served (ENS.COST), is intelligently evaluated and optimized using a firefly algorithm, from where savings of 43.3% on energy not served are achieved.
文摘In the design of the CAT 3408 engine, the Low Temperature (BT) circuits used to cool the engine lubricating oil and the charge air and the High Temperature (HT) circuits for cooling the cylinder liners, cylinder heads and body of turbofans are mainly used to cool the engine, so that it works properly. This work, based on the analysis carried out, to determine the lubrication compliance of the Yacco VX 100 - SAE 15 W-40 oil and that of the Camwater water used in the engine of the Boat Yang 1 by carrying out a series of conventional tests such as that: the density, the viscosity, the viscosity index, the flash point, the density, the sulphate center content, the water content, the total acidity index (TAN), total basic number (TBN) and pour point for the oil case and pH, hardness, sodium chloride content [NaCl], sodium sulphate content [NaSO<sub>4</sub>] for the water case which will be compared to the specified requirements to determine whether compliance is achieved for each of these characteristics. The results of the oil and water samples taken from the engine after use show that the used oil gives a specific gravity of 0.8822, a viscosity (at 40°C) of 92.29 mm<sup>2</sup>/s, a viscosity (at 100°C) of 13.99 mm<sup>2</sup>/s, a viscosity index (VI) of 155.39, a pour point -21°C, a Flash Point (VO) 215°C, a Sulfated ash content of 18%, a density 881.5 kg/m<sup>3</sup>, a total basic number (TBN) of 12.60 mgKOH/g, a Total Acid Index (TAN) of 3.096 mgKOH/g, a Water Content of 1.8 % and the water used gives a pH of 6.00, a hardness of 3.2 french degrees, a sodium chloride content [NaCl] of 0.468 mg/L, and a calcium sulphate content [CaSO<sub>4</sub>] of 2.38345 mg/L. the results of the water content and content of sulfated centers justify the thermal overload and power losses in the marine diesel engine CAT 3408 of the boat Yang 1 because of their values which are not in conformity with the standards.
文摘We present a theoretic model to calculate skin depths and eddy-current power losses for a magnetic position sensor. Eddy-current, arised from the operation of an alternating-current excitation, induces secondary currents and fields between magnetic material and magnetic position sensor. In this paper, a magnetic position sensor system is simplified to be an outer-winding coil along the axial direction of a low carbon steel bar. The analytical model is derived from basic field and circuit theory considering a linear approximation for a nonlinear permeability. Thus the skin depths and eddy-current power losses from the model in eddy-current modeling techniques at various frequencies of an excited current source can be calculated. The proposed configuration is capable of predicting the skin depths and eddy-current power losses for a magnetic position sensor and has a consistence with experiments.
文摘This paper presents a powerful approach to find the optimal size and location of distributed generation units in a distribution system using GA (Genetic Optimization algorithm). It is proved that GA method is fast and easy tool to enable the planners to select accurate and the optimum size of generators to improve the system voltage profile in addition to reduce the active and reactive power loss. GA fitness function is introduced including the active power losses, reactive power losses and the cumulative voltage deviation variables with selecting weight of each variable. GA fitness function is subjected to voltage constraints, active and reactive power losses constraints and DG size constraint.
基金supported by the Frontier Research of Large Science Installation(2016YFA0401902)the Youth Innovation Promotion Association CAS(No.2018300)
文摘Shanghai high-repetition-rate XFEL and extreme light facility (SHINE), the first hard XFEL based on a superconducting accelerated structure in China, is now under development at the Shanghai Institute of Applied Physics, Chinese Academy of Sciences. In this paper, power losses caused by trapped longitudinal high-order modes (HOM), steady-state loss, and transient loss generated by untrapped HOMs in the 1.3-GHz SHINE cryomodule are investigated and calculated. The heat load generated by resistive wall wakefields is considered as well. Results are presented for power losses of every element in the 1.3-GHz cryomodule, caused by HOM excitation in the acceleration RF system of the continuouswave linac of SHINE.
基金supported by National Basic Research Program of China(973 Program)(2011CB209404)
文摘An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.
文摘Harmonics in power systems is increasingly at high level. Also, there has been an incredible growth in the use of cross linked polyethylene (XLPE) cables in distribution systems. Harmonics cause additional power loss/temperature rise;causing premature failure of cables. Catastrophic failure of power cables leads to great inconvenience to consumers and loss of system reliability and money. To avoid the overheating of power cables;the additional power loss due to harmonics should be accurately calculated and properly accommodated by derating the cable. The present method of calculating the power loss in cables in harmonics rich environment is very arduous. The aim of this paper is to present the reasonably accurate method for evaluating effects of harmonics on the power loss in XLPE cables. Computational model is developed in MATLAB for power loss calculation using conventional method. Using this model, calculations are performed for aluminium and copper conductor XLPE cables of different size and type;for three different types of harmonics spectrums having total harmonics distortion (THD) of 30.68%, including all odd harmonics components up to 49th order. Using these results;a mathematical model in the form of simple empirical formula is developed by curve fitting technique. The results obtained by various models are presented and compared with error justification.
文摘With the development of concentrated wind power areas, new energy’s dispatching problems are more prominent with its fast expansion. However, we can maximize the utilization of wind power under power curtailment conditions by optimal wind power dispatching. The paper studies on the basic theories of wind power turbines, and analyses the power’s control and output characteristics of wind turbine, which analyses the double-fed inductor generator’s excellent decoupling control of power and its excellent reactive power output capability. By studying the characteristics of wind power output, this paper provides a strategy for optimal dispatch in wind power generation. The calculation results show that the total active and reactive power output of the wind farm match the request of dispatch center. And the total active loss and total reactive loss is the least in the meantime.
文摘Improving vehicle transmission efficiency and reducing vehicle fuel consumption is currently one of the main objectives in the automotive field. Reducing gear churning power losses has significant influence on the decreasing vehicle fuel consumption. Based on the two phase flow theory, a 2D two-phase model of the simplified hypoid gear is established to predict the churning losses in different conditions, the VOF method is introduced to track the volume fraction of the free surface, a standard k-ε model is also built to calculate complex turbulence. The oil distributions at the different rotational speed, the different immersion depth and the different viscosity as well as the churning losses of the hypoid gear are obtained and discussed in detail. In general, the churning power losses increase with the increase of the speed, the immersion depth and the viscosity, while the rotational speed shows the greatest influence on the churning losses. It is hoped that this investigation will be helpful in automotive industry applications.
文摘Ideally,converter losses should be determined without using an excessive amount of simulation time.State-of-the-art power semiconductor models provide good accuracy,unfortunately they often require a very long simulation time.This paper describes how to estimate power losses from simulation using ideal switches combined with measured power loss data.The semiconductor behavior is put into a look-up table,which replaces the advanced semiconductor models and shortens the simulation time.To extract switching and conduction losses,a converter is simulated and the semiconductor power losses are estimated.Measurement results on a laboratory converter are compared with the estimated losses and a good agreement is shown.Using the ideal switch simulation and the post processing power estimation program,a ten to twenty fold increase in simulation speed is obtained,compared to simulations using advanced models of semiconductors.