期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Development and Validation of Liquid Chromatographic Method for the Determination of the Related Substances of Rifampicin 被引量:2
1
作者 朱斌 胡昌勤 《Journal of Chinese Pharmaceutical Sciences》 CAS 2002年第1期19-23,共5页
A number of HPLC methods have been approved for the determination of rifampicin, but no references involved the assay of related substances of rifampicin. In the present paper, a reversed-phase liquid chromatographic ... A number of HPLC methods have been approved for the determination of rifampicin, but no references involved the assay of related substances of rifampicin. In the present paper, a reversed-phase liquid chromatographic method for the determination of related substances of rifampicin is developed and validated. Rifampicin and its related substances, including rifamycin SV, rifampicin N-oxide and 3-formylrifamycin SV were separated using a Zorbax Eclipse C8, 250×4.6 mm(i.d), 5 μm column by isocratic elution at a flow rate of 1 mL·min -1. The detector was set at 254 nm. The mobile phase is a mixture of methanol-acetonitrile -0.075 mol·L -1 monopotassium phosphate -1.0 mol·L -1 citric acid (31:31:35:3, v/v). The method validation included accuracy, precision, linearity, sensitivity and stability. All results are shown to be acceptable. 展开更多
关键词 RIFAMPICIN related substances HPLC
下载PDF
Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation 被引量:2
2
作者 Vivekanand A.Chatpalliwar Pawan K.Porwal Neeraj Upmanyu 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第3期226-237,共12页
A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride(DTZ) together with its six related substances(Diltiazem sulphoxide,Imp-A,Imp-B,Imp... A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride(DTZ) together with its six related substances(Diltiazem sulphoxide,Imp-A,Imp-B,Imp-D,Imp-E,and Imp-F) in a laboratory mixture as well as in a novel tablet formulation developed in-house.Efficient chromatographic separation was achieved on a Hypersil BDS C18(150 mm*4.6 mm,5.0 μm) with mobile phase containing 0.2% Triethylamine(TEA) in gradient combination with acetonitrile(ACN) at a flow rate of 1.0 mL/min and the eluent was monitored at 240 nm.In the developed method,the resolution of DTZ from any pair of impurities was found to be greater than 2.0.The test solution and related substances were found to be stable in the diluent for 24 h.The developed method resolved the drug from its known impurities,stated above,and also from additional impurities generated when the formulation was subjected to forced degradation;the mass balance was found close to 99.9%.Regression analyses indicate correlation coefficient value greater than 0.997 for DTZ and its six known impurities.The LOD for DTZ and the known impurities was at a level below 0.02%.The method has shown good,consistent recoveries for DTZ(99.8-101.2%) and also for its six known impurities(97.2-101.3%).The method was found to be accurate,precise,linear,specific,sensitive,rugged,robust,and stability-indicating. 展开更多
关键词 Diltiazem Hydrochloride BENZODIAZEPINE STABILITY-INDICATING related substances ICH guidelines HPLC
下载PDF
Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods 被引量:1
3
作者 Cheng-Ping Li1,2,Mao Mao1,Lan-Jun Zheng1,Wei-Guang Shan11.College of Pharmaceutical Sciences,Zhejiang University of Technology,Hangzhou 310032 2.College of Biology and Environment Engineering,Zhejiang Shuren University,Hangzhou 310015,China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第4期218-222,共5页
Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 co... Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine. 展开更多
关键词 GANCICLOVIR related substances high performance liquid chromatography high performance liquid chromatography/mass spectrometry
下载PDF
Determination of 9-Deoxo-9a-Aza-9a-Homoerythromycin A and Related Substances by High-Performance Liquid Chromatography
4
作者 史颖 姚国伟 +1 位作者 欧育湘 马敏 《Journal of Beijing Institute of Technology》 EI CAS 2005年第4期420-424,共5页
A high-performance liquid chromatography(HPLC) method was developed and validated for the assay of 9-deoxo-9a-aza-9a-homoerythromycin A and related substances that might coexist in products as impurities that origin... A high-performance liquid chromatography(HPLC) method was developed and validated for the assay of 9-deoxo-9a-aza-9a-homoerythromycin A and related substances that might coexist in products as impurities that originate from the synthesis processes. A chromatographic system comprising an ODS 150 mm× 4.6 mm I.D. column, a mobile phase of cetonitrile monobasic potassium phosphate buffer (25/75), a flow rate of 1.2 mL/min, a temperature of 30 ℃and a UV detector set at 205 nm has shown good chromatographic separation for 9-deoxo-9a-aza-9a-homoerythromycin A and other related substances. The linearity of the calibration curves, the precision, expressed as relative standard deviations, of the HPLC method have been studied. The HPLC method under study was found to be specific, precise, accurate and reproducible, indicating stability. 展开更多
关键词 9-deoxo-9a-aza-9a-homoerythromycin A related substances HPLC
下载PDF
LC-MS/MS Method Applied to the Detection and Quantification of Ursodeoxycholic Acid Related Substances in Raw Material and Pharmaceutical Formulation
5
作者 Boscolo Oriana Flor Sabrina +4 位作者 Dobrecky Cecilia Martinefski Manuela Tripodi Valeria Lucangioli Silvia Silvia Lucangioli 《Journal of Pharmacy and Pharmacology》 2018年第5期448-455,共8页
Objective: To develop a highly sensitive LC-MS/MS (liquid chromatography-mass spectxometry/mass spectrometry) method applied to the detection and quantitation of UDCA (ursodeoxycholic acid) related substances suc... Objective: To develop a highly sensitive LC-MS/MS (liquid chromatography-mass spectxometry/mass spectrometry) method applied to the detection and quantitation of UDCA (ursodeoxycholic acid) related substances such as CA (cholic acid), DCA (deoxycholic acid), CDCA (chenodeoxycholic acid) and LCA (lithocholic acid) in raw material and pharmaceutical formulation. Methods: The method was validated for specificity, linearity, accuracy, precision, robustness. A triple quadrupole mass detector was employed, equipped with an ESI (electrospray ionization) source operated in the negative ion mode. The chromatographic system consisted of a Symmetry C 18 column (150 mm × 4.6 mm, id; particle size 5 μm) and methanol-acetonitrile-ammonium acetate (pH 7.6; 10 mM) (40:40:20, v/v/v) as the mobile phase. The chromatographic conditions were 25 uL injection volume, flow rate of 0.4 mL/min and column temperature set at 35℃. Key tindings: The method requires a minimum sample amount and presents very low LOD (limits of detection) for CA (0.29 ng/mL), DCA (0.59 ng/mL), CDCA (0.13 ng/mL) and LCA (0.44 ng/mL) in comparison to LC methods coupled to different detectors like UV (ultraviolet), fluorescence and refractive index. Conclusions: The developed and validated LC-MS/MS method for the determination of UDCA and related substances in raw material and in a suspension was advantageous since it required a minimum sample amount. In turn, it could be used as a stability indicating method. 展开更多
关键词 UDCA related substances LC mass detector pharmaceutical formulation.
下载PDF
Development and validation of a stability-indicating HPLC method for the determination of retigabine and its related substances in drug substances 被引量:1
6
作者 吴锡凤 邵凤 +1 位作者 陶春蕾 李杰 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2015年第4期241-249,共9页
A stability-indicating high-performance liquid chromatography(HPLC) method has been developed and validated for the separation and determination of Retigabine and its related substances. The chromatographic separati... A stability-indicating high-performance liquid chromatography(HPLC) method has been developed and validated for the separation and determination of Retigabine and its related substances. The chromatographic separation was achieved on Agilent Eclipse Plus C18 column(4.6 mm×150 mm, 5 μm). The mobile phase was constituted of triethylamine-phosphate buffer as A and acetonitrile as B. The analysates were then eluted under the gradient conditions as description in this paper. The forced degradation study validated that the newly developed method was specific and selective to the degraded products. The performance of the method was verified according to the present International Conference on Harmonisation(ICH) guidelines for specificity, linearity, accuracy, precision and robustness. The correlation coefficients for Retigabine and its six impurities were greater than 0.999, which was shown in the regression analysis. Limits of detection(LOD) of these impurities were in the range of 0.0092%–0.0103%, indicating the high sensitivity of the newly developed method. Accuracy of the method was determined on the basis of recoveries to be between 96.49% and 118.35% for all impurities. Relative standard derivation(RSD) receiving in the repeatability and intermediate precision experiment, was less than 1.0%. The method can be successfully applied to routine quantify and stability testing Retigabine and its related substances in bulk drugs. 展开更多
关键词 Retigabine HPLC related substances Forced degradation
原文传递
液质联用分析美伐他汀的有关物质 被引量:2
7
作者 金美春 郑朝阳 《分析测试学报》 CAS CSCD 北大核心 2007年第z1期84-86,共3页
HPLC-ESI MS/MS method for relative substances of Mevastatin was established.An Agilent C18 column 250×4.6mm;Mobile phase: acetonitrile-0.05% formic acid (70:30),flow rate 1.0 mL/min,and λ238 nm;MS and MS/MS spec... HPLC-ESI MS/MS method for relative substances of Mevastatin was established.An Agilent C18 column 250×4.6mm;Mobile phase: acetonitrile-0.05% formic acid (70:30),flow rate 1.0 mL/min,and λ238 nm;MS and MS/MS spectra of sample and relative substances were obtained,approximately speculated the structure of relative substances,providing useful information for study and quality control of Mevastatin. 展开更多
关键词 Mevastatin LC-MS/MS Relative substances
下载PDF
First synthesis and characterization of key stereoisomers related to Ezetimibe 被引量:1
8
作者 Yun Ren Yan-Jun Duan +3 位作者 Ren-Jun Li Yong Deng Li Hai Yong Wu 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第8期1157-1160,共4页
uring the laboratory optimization and the late phase manufacturing studies of the cholesterol absorption inhibitor Ezetimibe 1, the formation of several stereoisomers was observed. To study the complete stereoisomer p... uring the laboratory optimization and the late phase manufacturing studies of the cholesterol absorption inhibitor Ezetimibe 1, the formation of several stereoisomers was observed. To study the complete stereoisomer profile of Ezetimibe 1, we have synthesized and completely characterized several key stereoisomers of Ezetimibe 1 for the first time. This study will provide an access to the reference standard of these stereoisomers and may have some implications in the development of new medicines. 展开更多
关键词 EZETIMIBE related substances Stereoisomers profile Synthesis Characterization
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部