期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
ANALYSIS OF HUMAN PLACENTA BY ^(31)P NUCLEAR MAGNETIC RESONANCE AND THIN-LAYER CHROMATOGRAPHY SCANNING COMBINED WITH THE CORRECTIVE METHOD OF ABSORBANCE PROPORTIONAL COEFFICIENT
1
作者 Rong GUO Jian wei CHEN Yi Min XU AiHua ZHANG Nanjing College of Traditional Chinese Medicine,Nanjing 210029 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第12期1081-1084,共4页
Five phospholipids in human placenta were determined by phosphorus 31 nuclear magnetic resonance(^(31)P NMR)spectroscopy and thin-layer chromatography(TLC) scanning combined with the corrective method of absorbance pr... Five phospholipids in human placenta were determined by phosphorus 31 nuclear magnetic resonance(^(31)P NMR)spectroscopy and thin-layer chromatography(TLC) scanning combined with the corrective method of absorbance proportional coefficient. The NMR spectrometer used this investigation was a Bruker AM-500 spectrometer operating at 202.4 MHz for ^(31)P chemical shifts are relative to 85% phosphoric acid. TIC was carried out by silica gel H plate developed in chloroform-methanol-glacial acetic acid-ethanol-water(25:4:6:2:0.5),with Vaskovsky reagent as colour -developing agent of phospholipids. 展开更多
关键词 P NUCLEAR MAGNETIC RESONANCE AND THIN-LAYER CHROMATOGRAPHY SCANNING COMBINED WITH THE CORRECTIVE METHOD OF absorbance PROPORTIONAL coefficient ANALYSIS OF HUMAN PLACENTA BY LPC TLC
下载PDF
Statistical absorption coefficient of microperforated absorbers 被引量:7
2
作者 Christian Nocke LIU Ke MAA Dab-You (Institute of Acoustics, Academia Sinica Beijing 100080) 《Chinese Journal of Acoustics》 2000年第2期97-104,共8页
Special attention is paid to the characteristics of microperforated panel absorbers (MPA) in a sa-called random or diffuse sound field. Preliminary analysis based on the theory of “normal model” are given. Measureme... Special attention is paid to the characteristics of microperforated panel absorbers (MPA) in a sa-called random or diffuse sound field. Preliminary analysis based on the theory of “normal model” are given. Measurements for different kinds of MPA in the reveberation chamber have been carried out and useful results have been obtained. For the theoretical predictions, PC-software has been developed. The further stuides in the near future are proposed. 展开更多
关键词 Statistical absorption coefficient of microperforated absorbers
原文传递
Mass-transfer studies of solid-base catalyst-aided CO_(2) absorption and solid-acid catalyst-aided CO_(2) desorption for CO_(2) capture in a pilot plant using aqueous solutions of MEA and blends of MEA-MDEA and BEA-AMP
3
作者 James Coker Daniel Boafo Afari +1 位作者 Jessica Narku-Tetteh Raphael Idem 《Clean Energy》 EI 2019年第4期263-277,共15页
Mass-transfer studies of catalyst-aided CO_(2) absorption and desorption were performed in a full-cycle,bench-scale pilot plant to improve CO_(2) absorption using 5M MEA,5M MEA-2M MDEA and 2M BEA-2M AMP.A solid-base c... Mass-transfer studies of catalyst-aided CO_(2) absorption and desorption were performed in a full-cycle,bench-scale pilot plant to improve CO_(2) absorption using 5M MEA,5M MEA-2M MDEA and 2M BEA-2M AMP.A solid-base catalyst,K/MgO,and an acid catalyst,HZSM-5,were used to facilitate absorption and desorption,respectively.Absorption and desorption mass-transfer performance was presented in terms of the overall mass-transfer coefficient of the gas side(KGav)and liquid side(K_(L)a_(v)),respectively.For non-catalytic runs,the highest K_(G)a_(V) and K_(L)a_(V) were 0.086 Kmol m^(3).kPa.hr and 0.7851 hr for 2M BEA-2M AMP solvent.The results showed 38.7% KGav and 23.6% K_(L)a_(v) increase for 2M BEA-2M AMP with only HZSM-5 catalyst in desorber and a 95% K_(G)a_(V) and 45% K_(L)a_(V) increase for both K/MgO catalyst and HZSM-5 catalyst.This was attributed to the role of K/MgO in bonding loosely with CO_(2) and making it available for the amine reaction. 展开更多
关键词 HZSM-5 K/MgO catalyst CO_(2)removal efficiency CO_(2)capture mass-transfer coefficients of absorber(KGaV)and desorber(K_(L)a_(V))
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部