The Parameter identification model is proposed for determining the linear adsorptionisotherms and the solid diffusion coefficients by using adsorption chromatography. Axialdispersion coefficients is firstly determined...The Parameter identification model is proposed for determining the linear adsorptionisotherms and the solid diffusion coefficients by using adsorption chromatography. Axialdispersion coefficients is firstly determined by pulse-respond experiment technique with aninert substance as tracer then the elution curves of chromatography separating the isomermannitol and sorbitol are determined by the chromatographic measuring technique, andfinally the adsorption isotherms and the solid diffusion coefficients of mannitol andsorbitol on Ca2+ resins are estimated by using this model. The results show that the axialdispersion coefficients increase with fluid velocity increasing, the adsorption equilibriumconstants decrease with temperature rising;and the solid diffusion coefficients increasewith temperature rising. The theoretical elution curves are good agreement with theexperimental elution curves of the liquid adsorption chromatography separating themannitol and the sorbitol. The model provides a simple and reliable procedure to estimatethe kinetic and thermodynamic parameters of the adsorption.展开更多
The performance of adsorption and separation for liensinine, isoliensinine and neferine was studied by double-column adsorption chromatography using macroporous adsorption and cation exchange resins. The alkaloid extr...The performance of adsorption and separation for liensinine, isoliensinine and neferine was studied by double-column adsorption chromatography using macroporous adsorption and cation exchange resins. The alkaloid extract with 49.2% total contents by mass representing 10.6% liensinine, 10.6% isoliensinine and 28.0% neferine respectively was prepared by D72 cation exchange resins, in which most of the impurities were water-soluble alkaloids. Furthermore,the alkaloid extract with 82.6% total contents by mass containing 33.1%, 15.0% and 34.5% of the three adsorbates respectively was prepared by double-column adsorption chromatography using AKS-W macroporous adsorption and D72 cation exchange resins. As a result, the content of single and total alkaloids has been greatly increased by the double-column adsorption chromatography.展开更多
Our previous studies on bovine serum albumin (BSA) adsorption to diethylaminoethyl dextran (DEAE dextran, DexD, grafting-ligand) and DEAE (D, surface-ligand) modified Sepharose FF resins found that all the graft...Our previous studies on bovine serum albumin (BSA) adsorption to diethylaminoethyl dextran (DEAE dextran, DexD, grafting-ligand) and DEAE (D, surface-ligand) modified Sepharose FF resins found that all the grafted resins (FF-DexD and FF-D-DexD) exhibited extremely fast uptake rate (effective diffusivity, De, De/Do 〉 1.4), which was six times greater than the ungrafted resins (De/Do 〈 0.3). In this work, the influence of ionic strength (IS) on 6 typical DEAE dextran-grafted resins was investigated. Bath adsorption equilibria and kinetics, breakthrough, and linear gradient elution experiments were conducted. Commercial DEAE Sepharose FF was used for comparison. It is found that protein adsorption capacities on DEAE dextran-FF resins and the commercial resin decreased with increasing IS, but DEAE dextran-FF resins exhibited much higher capacity sensitivity to salt concentration. Besides, steeper decrease of adsorption capacities could be obtained at higher graftingligand or surface-ligand density. It is worth noting that the facilitating role of surface-ligand to the "chain delivery" effect was weakened after adding salt, leading to the less improvement in uptake rate by increasing surface-ligand density at higher IS. Although the uptake rates of the DEAE dextran-FF resins increased first and then decreased with increasing fS, they kept the extremely high level of De values (De/Do 〉 1.1 ) at the their working/binding IS range. Moreover, the DEAE dextran-FF resin displayed much higher adsorption capacities and De values than commercial ungrafted resin in their working condition. Furthermore, the column results of DEAE dextran-FF resins presented higher dynamic binding capacities than and similar elution ISs with DEAE Sepharose FF to achieve similar (or even higher) recoveries suggest the excellent chromatographic column performance of the DEAE dextran-FF resins. Finally, both high recovery and purity of BSA and γ-globulin could be easily achieved using the typical DEAE dextran-FF column, FF-D60-DexD160, to separate their binary mixtures, by step gradient elution. The research has provided new insights into the practical application of the series of DEAE-dextran grafted resins in protein chromatography and proved their superiority.展开更多
文摘The Parameter identification model is proposed for determining the linear adsorptionisotherms and the solid diffusion coefficients by using adsorption chromatography. Axialdispersion coefficients is firstly determined by pulse-respond experiment technique with aninert substance as tracer then the elution curves of chromatography separating the isomermannitol and sorbitol are determined by the chromatographic measuring technique, andfinally the adsorption isotherms and the solid diffusion coefficients of mannitol andsorbitol on Ca2+ resins are estimated by using this model. The results show that the axialdispersion coefficients increase with fluid velocity increasing, the adsorption equilibriumconstants decrease with temperature rising;and the solid diffusion coefficients increasewith temperature rising. The theoretical elution curves are good agreement with theexperimental elution curves of the liquid adsorption chromatography separating themannitol and the sorbitol. The model provides a simple and reliable procedure to estimatethe kinetic and thermodynamic parameters of the adsorption.
基金The Educational Bureau of Hebei Province (Grant No.2007317)Scientific Foundation of Langfang Normal College (Grant No.LS200513)Nankai University Innovation Fund
文摘The performance of adsorption and separation for liensinine, isoliensinine and neferine was studied by double-column adsorption chromatography using macroporous adsorption and cation exchange resins. The alkaloid extract with 49.2% total contents by mass representing 10.6% liensinine, 10.6% isoliensinine and 28.0% neferine respectively was prepared by D72 cation exchange resins, in which most of the impurities were water-soluble alkaloids. Furthermore,the alkaloid extract with 82.6% total contents by mass containing 33.1%, 15.0% and 34.5% of the three adsorbates respectively was prepared by double-column adsorption chromatography using AKS-W macroporous adsorption and D72 cation exchange resins. As a result, the content of single and total alkaloids has been greatly increased by the double-column adsorption chromatography.
基金Supported by the National Natural Science Foundation of China(21406160,21621004)
文摘Our previous studies on bovine serum albumin (BSA) adsorption to diethylaminoethyl dextran (DEAE dextran, DexD, grafting-ligand) and DEAE (D, surface-ligand) modified Sepharose FF resins found that all the grafted resins (FF-DexD and FF-D-DexD) exhibited extremely fast uptake rate (effective diffusivity, De, De/Do 〉 1.4), which was six times greater than the ungrafted resins (De/Do 〈 0.3). In this work, the influence of ionic strength (IS) on 6 typical DEAE dextran-grafted resins was investigated. Bath adsorption equilibria and kinetics, breakthrough, and linear gradient elution experiments were conducted. Commercial DEAE Sepharose FF was used for comparison. It is found that protein adsorption capacities on DEAE dextran-FF resins and the commercial resin decreased with increasing IS, but DEAE dextran-FF resins exhibited much higher capacity sensitivity to salt concentration. Besides, steeper decrease of adsorption capacities could be obtained at higher graftingligand or surface-ligand density. It is worth noting that the facilitating role of surface-ligand to the "chain delivery" effect was weakened after adding salt, leading to the less improvement in uptake rate by increasing surface-ligand density at higher IS. Although the uptake rates of the DEAE dextran-FF resins increased first and then decreased with increasing fS, they kept the extremely high level of De values (De/Do 〉 1.1 ) at the their working/binding IS range. Moreover, the DEAE dextran-FF resin displayed much higher adsorption capacities and De values than commercial ungrafted resin in their working condition. Furthermore, the column results of DEAE dextran-FF resins presented higher dynamic binding capacities than and similar elution ISs with DEAE Sepharose FF to achieve similar (or even higher) recoveries suggest the excellent chromatographic column performance of the DEAE dextran-FF resins. Finally, both high recovery and purity of BSA and γ-globulin could be easily achieved using the typical DEAE dextran-FF column, FF-D60-DexD160, to separate their binary mixtures, by step gradient elution. The research has provided new insights into the practical application of the series of DEAE-dextran grafted resins in protein chromatography and proved their superiority.