The dynamic performances of an ultra-precision fly cutting machine tool(UFCMT)has a dramatic impact on the quality of ultra-precision machining.In this study,the dynamic model of an UFCMT was established based on the ...The dynamic performances of an ultra-precision fly cutting machine tool(UFCMT)has a dramatic impact on the quality of ultra-precision machining.In this study,the dynamic model of an UFCMT was established based on the transfer matrix method for multibody systems.In particular,the large-span scale flow field mesh model was created;and the variation in linear and angular stiffness of journal and thrust bearings with respect to film thickness was investigated by adopting the dynamic mesh technique.The dynamic model was proven to be valid by comparing the dynamic characteristics of the machine tool obtained by numerical simulation with the experimental results.In addition,the power spectrum density estimation method was adopted to simulate the statistical ambient vibration excitation by processing the ambient vibration signal measured over a long period of time.Applying it to the dynamic model,the dynamic response of the tool tip under ambient vibration was investigated.The results elucidated that the tool tip response was significantly affected by ambient vibration,and the isolation foundation had a good effect on vibration isolation.展开更多
In this study,the methodology and results of ambient vibration-based investigations of the historical Tash Mosque in Kosovo and a 3-story historical building in Bulgaria are presented.The investi gations include full-...In this study,the methodology and results of ambient vibration-based investigations of the historical Tash Mosque in Kosovo and a 3-story historical building in Bulgaria are presented.The investi gations include full-scale in situ testing of both structures due to ambient vibrations induced by micro-seismic,wind,traffic,and other human activities.To this aim,Ranger seismometers and Kinemetric products were used.Measurements were performed in both horizontal directions in several points along the structures'height utilizing a high-speed data acquisition device.All recorded data have been analyzed and processed by the software developed at IZIIS,and then the processed data were used as input for modal analysis.The basic assumption is that the excitation can be considered as a stationary random process to have a relatively flat spectrum.The paper clearly describes the procedure used for investigations and presents the dynamic properties of the whole structures.The inv estigated structures are both historical buildings and defined as architectural heritage and the outcome of this study including the natural vibration frequencies and mode shapes)can be very benefi-cial for the verification stage of the analytical/numerical models for future retro-fiting/rehabilitation schemes.展开更多
Operational modal analysis is a non-destructive structural investigation that considers only the loads resulting from service conditions.This approach allows the measurement of vibrations on a given structure with no ...Operational modal analysis is a non-destructive structural investigation that considers only the loads resulting from service conditions.This approach allows the measurement of vibrations on a given structure with no need to interrupt its use.The present work aims to develop a numerical model to represent the global structural behavior of a vessel breasting dolphin using a technique that is simple and cheap in order to obtain a fast answer about the stiffness of a pier after the collision of ships with capacity up to 400,000 t.To determine the modes of vibration,one accelerometer was installed on the breasting dolphin located on the pier and a frequency domain technic was conducted over recorded data to obtain modal parameters of the structure.In situ measurements were compared to data from a finite element model based on the original structural design in order to adapt the model to accurately represent the actual behavior of the system.This allowed a reliable structural analysis that accounted for existing structural damage and imperfections.The results of the experiment presented herein are the numerical characterization of the structure,along with the structural analysis to assess the degree of damage currently observed on the system.It is noted that the dolphin subjected to ship impacts presents a reduction in stiffness of approximately10%and its global damage level can be monitored from now after new accidents.展开更多
The practical difficulties presented by forced vibration testing of large steel structures, such as tall buildings, transmission lines or bridges, led to an increased interest in structural monitoring through ambient ...The practical difficulties presented by forced vibration testing of large steel structures, such as tall buildings, transmission lines or bridges, led to an increased interest in structural monitoring through ambient vibrations, which usually allows the proper identification of modal properties, natural frequencies, damping and modes of vibration. Changes in these modal properties constitute an indication of structural damage, which may then be assessed on the basis of experimental evidence. The authors proposed an approach to determine the so-called damage damping and stiffness matrices, which are essential to identify the location and intensity of damage. No restrictions were introduced on the damping matrix of the system. The approach requires ambient vibration data of all relevant coordinates used in the structural model, which are processed employing the SSI method. In practice, the identification method is seriously hampered by ambient factors such as temperature or humidity. In general those effects must be filtered out in other to obtain a reliable diagnosis of damage, approach that demands long term monitoring. In this paper, an alternative approach is explored, based on the introduction of error damping and stiffness matrices. Data on both matrices is generated on the basis of observed variations of structural member stiffness and damping caused by ambient factors. The influence of this uncertainty on the identified spectral properties is assessed by simulation.展开更多
This article describes an improved data acquisition system from a previous system dedicated to one-sensor site studies, aimed at recording ambient vibrations (microtremors). A multi-channel and/or remote triggering sy...This article describes an improved data acquisition system from a previous system dedicated to one-sensor site studies, aimed at recording ambient vibrations (microtremors). A multi-channel and/or remote triggering system is proposed. The system was conceived by IRD-Leas, France, and used at ISTerre, France, for research activities. The size, weight of this high quality system and its autonomy (no need to be connected to a laptop) make it a real portable device. The system acquires data with 24-bit delta-sigma ADCs in the 10 - 1000 sps range at 10 - 20 bit resolution on up to 18 channels in the multi-channel version. The input stage dynamics is available at ±2.5 V or ±5 V. The dynamic range varies, for example, from 108 dB at 100 sps to 90 dB at 250 sps. Gain is selectable from 1 (0 dB) to 8192 (78 dB) by powers of two (6 dB). Its very low level of internal noise allows recording of very low tension signals without missing code. Continuous recording and GPS may also be implemented in the system. While primarily dedicated to ambient vibration recordings, this system can be connected to any type of device delivering an output tension in the ±5 V range.展开更多
This paper presents an effective approach for updating finite element dynamic model from incomplete modal data identified from ambient vibration measurements.The proposed method is based on the relationship between th...This paper presents an effective approach for updating finite element dynamic model from incomplete modal data identified from ambient vibration measurements.The proposed method is based on the relationship between the perturbation of structural parameters such as stiffness and mass changes and the modal data measurements of the tested structure such as measured mode shape readings.Structural updating parameters including both stiffness and mass parameters are employed to represent the differences in structural parameters between the finite element model and the associated tested structure.These updating parameters are then evaluated by an iterative solution procedure,giving optimised solutions in the least squares sense without requiring an optimisation technique.In order to reduce the influence of modal measurement uncertainty,the truncated singular value decomposition regularization method incorporating the quasi-optimality criterion is employed to produce reliable solutions for the structural updating parameters.Finally,the numerical investigations of a space frame structure and the practical applications to the Canton Tower benchmark problem demonstrate that the proposed method can correctly update the given finite element model using the incomplete modal data identified from the recorded ambient vibration measurements.展开更多
The main purpose of the present study is to enhance high-level noisy data by a wavelet-based iterative filtering algorithm for identification of natural frequencies during ambient wind vibrational tests on a petrochem...The main purpose of the present study is to enhance high-level noisy data by a wavelet-based iterative filtering algorithm for identification of natural frequencies during ambient wind vibrational tests on a petrochemical process tower.Most of denoising methods fail to filter such noise properly.Both the signal-to-noise ratio and the peak signal-to-noise ratio are small.Multiresolution-based one-step and variational-based filtering methods fail to denoise properly with thresholds obtained by theoretical or empirical method.Duc to the fact that it is impossible to completely denoise such high-level noisy data,the enhancing approach is used to improve the data quality,which is the main novelty from the application point of view here.For this iterative method,a simple computational approach is proposed to estimate the dynamic threshold values.Hence,different thresholds can be obtained for different recorded signals in one ambient test.This is in contrast to commonly used approaches recommending one global threshold estimated mainly by an empirical method.After the enhancements,modal frequencies are directly detected by the cross wavelet transform(XWT),the spectral power density and autocorrelation of wavelet coefficients.Estimated frequencies are then compared with those of an undamaged-model,simulated by the finite element method.展开更多
An ambient vibration test on a concrete bridge constructed in 1971 and calibration of its finite element model are presented.The bridge is characterized by a system of post-tensioned and simply supported beams.The dyn...An ambient vibration test on a concrete bridge constructed in 1971 and calibration of its finite element model are presented.The bridge is characterized by a system of post-tensioned and simply supported beams.The dynamic characteristics of the bridge,i.e.natural frequencies,mode shapes and damping ratios were computed from the ambient vibration tests by using the Eigensystem Realization Algorithm(ERA).Then,these characteristics were used to update the finite element model of the bridge by formulating an optimization problem and then using Genetic Algorithms(GA)to solve it.From the results of the ambient vibration test of this type of bridge,it is concluded that two-dimensional mode shapes exist:in the longitudinal and transverse;and these experimentally obtained dynamic characteristics were also achieved in the analytical model through updating.The application of GAs as optimization techniques showed great versatility to optimize any number and type of variables in the model.展开更多
Recently,ambient vibration test(AVT)is widely used tu estimate dynamic characteristics of large civil struc- tures.Dynamic characteristics ean be affected by various envirnnmental factors such as humidity,intensity of...Recently,ambient vibration test(AVT)is widely used tu estimate dynamic characteristics of large civil struc- tures.Dynamic characteristics ean be affected by various envirnnmental factors such as humidity,intensity of wind,and temperature.Besides these environmental conditions,tire mass of vehicles may change the measured valnes when traffic-in- duced vibration is used as a source of AVT tor bridges.The effect of vehicle mass on dynamic characteristics is investigated through traffic-induced vibration tests on three bridges;(1)three-span suspension bridge(128m+404m+128m),(2) five-span continuous steel box girder bridge(59m+3@ 95m+59m),(3)simply supported plate girder bridge(46m). Acceleration histories of each measurement location under normal traffic are recorded for 30 minutes at field.These recor- ded histories are divided into individual vibrations and are combined into two groups aceording to the level of vibration;one by heavy vehicles such as trucks and buses and the other by light vehicles such as passenger cars.Separate processing of the two groups of signals shows that,for the middle and long-span bridges,the difference can be hardly detected,but,for the short span bridges whose mass is relatively small,the measured natural frequencies can change up to 5.4%.展开更多
The main aim of this study is to understand the dynamic behavior of a cable-stayed bridge, using both numerical and experimental analysis. A three-dimensional finite element model for the bridge was developed for the ...The main aim of this study is to understand the dynamic behavior of a cable-stayed bridge, using both numerical and experimental analysis. A three-dimensional finite element model for the bridge was developed for the free vibration analysis and the ambient vibration properties of the bridge were determined through field testing. The experimental and numerical results of natural frequencies and the associated mode shapes were compared, and the high accuracy between them shows that the 3D model is capable of approximately representing the dynamic behavior of the bridge and the use of ambient vibration survives in future testing of the bridge. These dynamic characteristics can be used as the basis for updating the finite element model and also for global damage detection.展开更多
An output-only modal identification method by a combination use of the peak-picking method and the cross spectrum methods are presented. Meanwhile, a novel mode shape optimum method of the deck is proposed. The method...An output-only modal identification method by a combination use of the peak-picking method and the cross spectrum methods are presented. Meanwhile, a novel mode shape optimum method of the deck is proposed. The methods are applied to the operational modal identification system of the Runyang Suspension Bridge, which can be used to obtain the modal parameters of the bridge from out-only data sets collected by its structural health monitoring system (SHMS). As an example, the vibration response data of the deck, cable and tower recorded during typhoon Matsa excitation are used to illustrate the program application. Some of the modal frequencies observed from deck vibration responses are also found in the vibration responses of the cable and the tower. The results show that some modal shapes of the deck are strongly coupled with the cable and the tower. By comparing the identification results from the operational modal system with those from field measurements, a good agreement between them is achieved, but some modal frequencies identified from the operational modal identification system (OMIS), such as L1 and L2, obviously decrease compared with those from the field measurements.展开更多
During the service life of civil engineering structures such as long-span bridges, local damage at key positions may continually accumulate, and may finally result in their sudden failure. One core issue of global vib...During the service life of civil engineering structures such as long-span bridges, local damage at key positions may continually accumulate, and may finally result in their sudden failure. One core issue of global vibration-based health monitoring methods is to seek some damage indices that are sensitive to structural damage, This paper proposes an online structural health monitoring method for long-span suspension bridges using wavelet packet transform (WPT). The WPT- based method is based on the energy variations of structural ambient vibration responses decomposed using wavelet packet analysis. The main feature of this method is that the proposed wavelet packet energy spectrum (WPES) has the ability to detect structural damage from ambient vibration tests of a long-span suspension bridge. As an example application, the WPES-based health monitoring system is used on the Runyang Suspension Bridge under daily environmental conditions. The analysis reveals that changes in environmental temperature have a long-term influence on the WPES, while the effect of traffic loadings on the measured WPES of the bridge presents instantaneous changes because of the nonstationary properties of the loadings. The condition indication indices VD reflect the influences of environmental temperature on the dynamic properties of the Runyang Suspension Bridge. The field tests demonstrate that the proposed WPES-based condition indication index VD is a good candidate index for health monitoring of long-span suspension bridges under ambient excitations.展开更多
The dynamic finite element model (FEM) of a prestressed concrete continuous box-girder bridge, called the Tongyang Canal Bridge, is built and updated based on the results of ambient vibration testing (AVT) using a...The dynamic finite element model (FEM) of a prestressed concrete continuous box-girder bridge, called the Tongyang Canal Bridge, is built and updated based on the results of ambient vibration testing (AVT) using a real-coded accelerating genetic algorithm (RAGA). The objective functions are defined based on natural frequency and modal assurance criterion (MAC) metrics to evaluate the updated FEM. Two objective functions are defined to fully account for the relative errors and standard deviations of the natural frequencies and MAC between the AVT results and the updated FEM predictions. The dynamically updated FEM of the bridge can better represent its structural dynamics and serve as a baseline in long-term health monitoring, condition assessment and damage identification over the service life of the bridge .展开更多
Modal parameters, including fundamental frequencies, damping ratios, and mode shapes, could be used to evaluate the health condition of structures. Automatic modal parameter identification, which plays an essential ro...Modal parameters, including fundamental frequencies, damping ratios, and mode shapes, could be used to evaluate the health condition of structures. Automatic modal parameter identification, which plays an essential role in realtime structural health monitoring, has become a popular topic in recent years. In this study, an automatic modal parameter identification procedure for high arch dams is proposed. The proposed procedure is implemented by combining the densitybased spatial clustering of applications with noise(DBSCAN) algorithm and the stochastic subspace identification(SSI). The 210-m-high Dagangshan Dam is investigated as an example to verify the feasibility of the procedure. The results show that the DBSCAN algorithm is robust enough to interpret the stabilization diagram from SSI and may avoid outline modes. This leads to the proposed procedure obtaining a better performance than the partitioned clustering and hierarchical clustering algorithms. In addition, the errors of the identified frequencies of the arch dam are within 4%, and the identified mode shapes are in agreement with those obtained from the finite element model, which implies that the proposed procedure is accurate enough to use in modal parameter identification. The procedure is feasible for online modal parameter identification and modal tracking of arch dams.展开更多
Analytical models prepared from field drawings do not generally provide results that match with experimental results.The error may be due to uncertainties in the property of materials,size of members and errors in the...Analytical models prepared from field drawings do not generally provide results that match with experimental results.The error may be due to uncertainties in the property of materials,size of members and errors in the modelling process.It is important to improve analytical models using experimentally obtained data.For the past several years,data obtained from ambient vibration testing have been successfully used in many cases to update and match dynamic behaviors of analytical models with real structures.This paper presents a comparison between artificial neural network(ANN) and eigensensitivity based model updating of an existing multi-story building.A simple spring-mass analytical model,developed from the structural drawings of the building,is considered and the corresponding spring stiffness and lumped mass of all floors are chosen as updating parameters.The advantages and disadvantages of these updating methods are discussed.The advantage is that both methods ensure a physically meaningful model which canbe further employed in determining structural response and health monitoring.展开更多
The effects of concrete's time-variant elastic modulus,casting structural components,assembling temporary shoring framework system,and shock by operating construction equipment on dynamic behavior of the reinforce...The effects of concrete's time-variant elastic modulus,casting structural components,assembling temporary shoring framework system,and shock by operating construction equipment on dynamic behavior of the reinforced concrete frame structure during construction were investigated. The dynamic tests of an eight-storey reinforced concrete frame structure during full-scaled stages of the sixth storey construction cycle were carried out by ambient vibration. Natural frequencies,corresponding mode shapes and damping ratio were determined by power spectrum processing the tested signal data in frequency domain. The changes of frequencies,mode shapes and damping ratios at different construction stages were given. The results show that natural frequencies and modal damping ratios reach the maximum at stage of casting fresh concrete,especially for higher modes. Modal damping ratios at each construction stage are less than 5% of those during usage.展开更多
As a type of nonstructural component, infill walls play a significant role in the seismic behavior of high-rise buildings. However, the stiffness of the infill wall is generally either ignored or considered by simplif...As a type of nonstructural component, infill walls play a significant role in the seismic behavior of high-rise buildings. However, the stiffness of the infill wall is generally either ignored or considered by simplified empirical criteria that lead to a period shortening. The difference can be greatly decreased by using a structural identification methodology. In this study, an ambient vibration test was performed on four on-site reinforced concrete high-rise buildings, and the design results were compared with the PKPM models using corresponding finite element(FE) models. A diagonal strut model was used to simulate the behavior of the infill wall, and the identified modal parameters measured from the on-site test were employed to calibrate the parameters of the diagonal strut in the FE models. The SAP2000 models with calibrated elastic modulus were used to evaluate the seismic response in the elastic state. Based on the load-displacement relationship of the infill wall, nonlinear dynamic analysis models were built in PERFORM-3 D and calibrated using the measured modal periods. The analysis results revealed that the structural performance under small/large earthquake records were both strengthened by infill walls, and the contribution of infill walls should be considered for better accuracy in the design process.展开更多
In this review article,the past investigations carried out on heritage structures using Ambient Vibration Test(AVT)and Operational Modal Analysis(OMA)for system identification(determination of dynamic properties like ...In this review article,the past investigations carried out on heritage structures using Ambient Vibration Test(AVT)and Operational Modal Analysis(OMA)for system identification(determination of dynamic properties like frequency,mode shape and damping ratios)and associated applications are summarized.A total of 68 major research studies on heritage structures around the world that are available in literature are surveyed for this purpose.At first,field investigations carried out on heritage structures prior to conducting AVT are explained in detail.Next,specifications of accelerometers,location of accelerometers and optimization of accelerometer networks have been elaborated with respect to the geometry of the heritage structures.In addition to this,ambient vibration loads and data acquisition procedures are also discussed.Further,the state of art of performing OMA techniques for heritage structures is explained briefly.Furthermore,various applications of system identification for heritage structures are documented.Finally,conclusions are made towards errorless system identification of heritage structures through AVT and OMA.展开更多
Being able to significantly reduce system installation time and cost,wireless sensing technology has attracted much interest in the structural health monitoring(SHM)community.This paper reports the field application o...Being able to significantly reduce system installation time and cost,wireless sensing technology has attracted much interest in the structural health monitoring(SHM)community.This paper reports the field application of a wireless sensing system on a 4-span highway bridge located in Wayne,New Jersey in the US.Bridge vibration due to traffic and ambient excitation is measured.To enhance the signal-to-noise ratio,a low-noise high-gain signal conditioning module is developed for the wireless sensing system.Nineteen wireless and nineteen cabled accelerometers are first installed along the sidewalk of two neighboring bridge spans.The performance of the wireless sensing system is compared with the high-precision cabled sensing system.In the next series of testing,16 wireless accelerometers are installed under the deck of another bridge span,forming a 4×4 array.Operating deflection analysis is successfully conducted using the wireless measurement of traffic and ambient vibrations.展开更多
Condition assessment of bridges has become increasingly important. In order to accurately simulate the real bridge, finite element (FE) model updating method is often applied. This paper presents the calibration of ...Condition assessment of bridges has become increasingly important. In order to accurately simulate the real bridge, finite element (FE) model updating method is often applied. This paper presents the calibration of the FE model of a reinforced concrete tied-arch bridge using Douglas-Reid method in combination with Rosenbrock optimization algorithm. Based on original drawings and topographic survey, a FE model of the investigated bridge is created. Eight global modes of vibration of the bridge are identified by ambient vibration tests and the frequency domain decomposition technique. Then, eight structural parameters are selected for FE model updating procedure through sensitivity analysis. Finally, the optimal structural parameters are identified using Rosenbrock optimization algorithm. Results show that although the identified parameters lead to a perfect agreement between approximate and measured natural frequencies, they may not be the optimal variables which minimize the differences between numerical and experimental modal data. However, a satisfied agreement between them is still presented. Hence, FE model updating based on Douglas-Reid method and Rosenbrock optimization algorithm could be used as an alternative to other complex updating procedures.展开更多
文摘The dynamic performances of an ultra-precision fly cutting machine tool(UFCMT)has a dramatic impact on the quality of ultra-precision machining.In this study,the dynamic model of an UFCMT was established based on the transfer matrix method for multibody systems.In particular,the large-span scale flow field mesh model was created;and the variation in linear and angular stiffness of journal and thrust bearings with respect to film thickness was investigated by adopting the dynamic mesh technique.The dynamic model was proven to be valid by comparing the dynamic characteristics of the machine tool obtained by numerical simulation with the experimental results.In addition,the power spectrum density estimation method was adopted to simulate the statistical ambient vibration excitation by processing the ambient vibration signal measured over a long period of time.Applying it to the dynamic model,the dynamic response of the tool tip under ambient vibration was investigated.The results elucidated that the tool tip response was significantly affected by ambient vibration,and the isolation foundation had a good effect on vibration isolation.
文摘In this study,the methodology and results of ambient vibration-based investigations of the historical Tash Mosque in Kosovo and a 3-story historical building in Bulgaria are presented.The investi gations include full-scale in situ testing of both structures due to ambient vibrations induced by micro-seismic,wind,traffic,and other human activities.To this aim,Ranger seismometers and Kinemetric products were used.Measurements were performed in both horizontal directions in several points along the structures'height utilizing a high-speed data acquisition device.All recorded data have been analyzed and processed by the software developed at IZIIS,and then the processed data were used as input for modal analysis.The basic assumption is that the excitation can be considered as a stationary random process to have a relatively flat spectrum.The paper clearly describes the procedure used for investigations and presents the dynamic properties of the whole structures.The inv estigated structures are both historical buildings and defined as architectural heritage and the outcome of this study including the natural vibration frequencies and mode shapes)can be very benefi-cial for the verification stage of the analytical/numerical models for future retro-fiting/rehabilitation schemes.
文摘Operational modal analysis is a non-destructive structural investigation that considers only the loads resulting from service conditions.This approach allows the measurement of vibrations on a given structure with no need to interrupt its use.The present work aims to develop a numerical model to represent the global structural behavior of a vessel breasting dolphin using a technique that is simple and cheap in order to obtain a fast answer about the stiffness of a pier after the collision of ships with capacity up to 400,000 t.To determine the modes of vibration,one accelerometer was installed on the breasting dolphin located on the pier and a frequency domain technic was conducted over recorded data to obtain modal parameters of the structure.In situ measurements were compared to data from a finite element model based on the original structural design in order to adapt the model to accurately represent the actual behavior of the system.This allowed a reliable structural analysis that accounted for existing structural damage and imperfections.The results of the experiment presented herein are the numerical characterization of the structure,along with the structural analysis to assess the degree of damage currently observed on the system.It is noted that the dolphin subjected to ship impacts presents a reduction in stiffness of approximately10%and its global damage level can be monitored from now after new accidents.
文摘The practical difficulties presented by forced vibration testing of large steel structures, such as tall buildings, transmission lines or bridges, led to an increased interest in structural monitoring through ambient vibrations, which usually allows the proper identification of modal properties, natural frequencies, damping and modes of vibration. Changes in these modal properties constitute an indication of structural damage, which may then be assessed on the basis of experimental evidence. The authors proposed an approach to determine the so-called damage damping and stiffness matrices, which are essential to identify the location and intensity of damage. No restrictions were introduced on the damping matrix of the system. The approach requires ambient vibration data of all relevant coordinates used in the structural model, which are processed employing the SSI method. In practice, the identification method is seriously hampered by ambient factors such as temperature or humidity. In general those effects must be filtered out in other to obtain a reliable diagnosis of damage, approach that demands long term monitoring. In this paper, an alternative approach is explored, based on the introduction of error damping and stiffness matrices. Data on both matrices is generated on the basis of observed variations of structural member stiffness and damping caused by ambient factors. The influence of this uncertainty on the identified spectral properties is assessed by simulation.
基金funded by IRD(Institut de Recherche pour le Developpement),a French public research institute,and LEAS company.
文摘This article describes an improved data acquisition system from a previous system dedicated to one-sensor site studies, aimed at recording ambient vibrations (microtremors). A multi-channel and/or remote triggering system is proposed. The system was conceived by IRD-Leas, France, and used at ISTerre, France, for research activities. The size, weight of this high quality system and its autonomy (no need to be connected to a laptop) make it a real portable device. The system acquires data with 24-bit delta-sigma ADCs in the 10 - 1000 sps range at 10 - 20 bit resolution on up to 18 channels in the multi-channel version. The input stage dynamics is available at ±2.5 V or ±5 V. The dynamic range varies, for example, from 108 dB at 100 sps to 90 dB at 250 sps. Gain is selectable from 1 (0 dB) to 8192 (78 dB) by powers of two (6 dB). Its very low level of internal noise allows recording of very low tension signals without missing code. Continuous recording and GPS may also be implemented in the system. While primarily dedicated to ambient vibration recordings, this system can be connected to any type of device delivering an output tension in the ±5 V range.
文摘This paper presents an effective approach for updating finite element dynamic model from incomplete modal data identified from ambient vibration measurements.The proposed method is based on the relationship between the perturbation of structural parameters such as stiffness and mass changes and the modal data measurements of the tested structure such as measured mode shape readings.Structural updating parameters including both stiffness and mass parameters are employed to represent the differences in structural parameters between the finite element model and the associated tested structure.These updating parameters are then evaluated by an iterative solution procedure,giving optimised solutions in the least squares sense without requiring an optimisation technique.In order to reduce the influence of modal measurement uncertainty,the truncated singular value decomposition regularization method incorporating the quasi-optimality criterion is employed to produce reliable solutions for the structural updating parameters.Finally,the numerical investigations of a space frame structure and the practical applications to the Canton Tower benchmark problem demonstrate that the proposed method can correctly update the given finite element model using the incomplete modal data identified from the recorded ambient vibration measurements.
基金The authors gratefully acknowledge the financial support of Iran National Science Foundation(INSF).
文摘The main purpose of the present study is to enhance high-level noisy data by a wavelet-based iterative filtering algorithm for identification of natural frequencies during ambient wind vibrational tests on a petrochemical process tower.Most of denoising methods fail to filter such noise properly.Both the signal-to-noise ratio and the peak signal-to-noise ratio are small.Multiresolution-based one-step and variational-based filtering methods fail to denoise properly with thresholds obtained by theoretical or empirical method.Duc to the fact that it is impossible to completely denoise such high-level noisy data,the enhancing approach is used to improve the data quality,which is the main novelty from the application point of view here.For this iterative method,a simple computational approach is proposed to estimate the dynamic threshold values.Hence,different thresholds can be obtained for different recorded signals in one ambient test.This is in contrast to commonly used approaches recommending one global threshold estimated mainly by an empirical method.After the enhancements,modal frequencies are directly detected by the cross wavelet transform(XWT),the spectral power density and autocorrelation of wavelet coefficients.Estimated frequencies are then compared with those of an undamaged-model,simulated by the finite element method.
文摘An ambient vibration test on a concrete bridge constructed in 1971 and calibration of its finite element model are presented.The bridge is characterized by a system of post-tensioned and simply supported beams.The dynamic characteristics of the bridge,i.e.natural frequencies,mode shapes and damping ratios were computed from the ambient vibration tests by using the Eigensystem Realization Algorithm(ERA).Then,these characteristics were used to update the finite element model of the bridge by formulating an optimization problem and then using Genetic Algorithms(GA)to solve it.From the results of the ambient vibration test of this type of bridge,it is concluded that two-dimensional mode shapes exist:in the longitudinal and transverse;and these experimentally obtained dynamic characteristics were also achieved in the analytical model through updating.The application of GAs as optimization techniques showed great versatility to optimize any number and type of variables in the model.
基金the Ministry of Construction and Transportation,Korea Highway Corporation and Hyundai E&C Co.Ltd.under Project No.R&D/970003-2.
文摘Recently,ambient vibration test(AVT)is widely used tu estimate dynamic characteristics of large civil struc- tures.Dynamic characteristics ean be affected by various envirnnmental factors such as humidity,intensity of wind,and temperature.Besides these environmental conditions,tire mass of vehicles may change the measured valnes when traffic-in- duced vibration is used as a source of AVT tor bridges.The effect of vehicle mass on dynamic characteristics is investigated through traffic-induced vibration tests on three bridges;(1)three-span suspension bridge(128m+404m+128m),(2) five-span continuous steel box girder bridge(59m+3@ 95m+59m),(3)simply supported plate girder bridge(46m). Acceleration histories of each measurement location under normal traffic are recorded for 30 minutes at field.These recor- ded histories are divided into individual vibrations and are combined into two groups aceording to the level of vibration;one by heavy vehicles such as trucks and buses and the other by light vehicles such as passenger cars.Separate processing of the two groups of signals shows that,for the middle and long-span bridges,the difference can be hardly detected,but,for the short span bridges whose mass is relatively small,the measured natural frequencies can change up to 5.4%.
基金This paper is supported by the programfor New Century Excellent Tal-ents in University (2004) .
文摘The main aim of this study is to understand the dynamic behavior of a cable-stayed bridge, using both numerical and experimental analysis. A three-dimensional finite element model for the bridge was developed for the free vibration analysis and the ambient vibration properties of the bridge were determined through field testing. The experimental and numerical results of natural frequencies and the associated mode shapes were compared, and the high accuracy between them shows that the 3D model is capable of approximately representing the dynamic behavior of the bridge and the use of ambient vibration survives in future testing of the bridge. These dynamic characteristics can be used as the basis for updating the finite element model and also for global damage detection.
基金The National High Technology Research and Development Program of China(863Program)(No.2006AA04Z416)
文摘An output-only modal identification method by a combination use of the peak-picking method and the cross spectrum methods are presented. Meanwhile, a novel mode shape optimum method of the deck is proposed. The methods are applied to the operational modal identification system of the Runyang Suspension Bridge, which can be used to obtain the modal parameters of the bridge from out-only data sets collected by its structural health monitoring system (SHMS). As an example, the vibration response data of the deck, cable and tower recorded during typhoon Matsa excitation are used to illustrate the program application. Some of the modal frequencies observed from deck vibration responses are also found in the vibration responses of the cable and the tower. The results show that some modal shapes of the deck are strongly coupled with the cable and the tower. By comparing the identification results from the operational modal system with those from field measurements, a good agreement between them is achieved, but some modal frequencies identified from the operational modal identification system (OMIS), such as L1 and L2, obviously decrease compared with those from the field measurements.
基金National Hi-Tech Research and Development Program of China (863 Program) (No. 2006AA04Z416)the National Natural Science Foundation of China Under Grant No. 50538020
文摘During the service life of civil engineering structures such as long-span bridges, local damage at key positions may continually accumulate, and may finally result in their sudden failure. One core issue of global vibration-based health monitoring methods is to seek some damage indices that are sensitive to structural damage, This paper proposes an online structural health monitoring method for long-span suspension bridges using wavelet packet transform (WPT). The WPT- based method is based on the energy variations of structural ambient vibration responses decomposed using wavelet packet analysis. The main feature of this method is that the proposed wavelet packet energy spectrum (WPES) has the ability to detect structural damage from ambient vibration tests of a long-span suspension bridge. As an example application, the WPES-based health monitoring system is used on the Runyang Suspension Bridge under daily environmental conditions. The analysis reveals that changes in environmental temperature have a long-term influence on the WPES, while the effect of traffic loadings on the measured WPES of the bridge presents instantaneous changes because of the nonstationary properties of the loadings. The condition indication indices VD reflect the influences of environmental temperature on the dynamic properties of the Runyang Suspension Bridge. The field tests demonstrate that the proposed WPES-based condition indication index VD is a good candidate index for health monitoring of long-span suspension bridges under ambient excitations.
基金National Natural Science Foundation of China Under Grant No.50575101Transportation Science Research Item of Jiangsu Province Under Grant No.06Y20
文摘The dynamic finite element model (FEM) of a prestressed concrete continuous box-girder bridge, called the Tongyang Canal Bridge, is built and updated based on the results of ambient vibration testing (AVT) using a real-coded accelerating genetic algorithm (RAGA). The objective functions are defined based on natural frequency and modal assurance criterion (MAC) metrics to evaluate the updated FEM. Two objective functions are defined to fully account for the relative errors and standard deviations of the natural frequencies and MAC between the AVT results and the updated FEM predictions. The dynamically updated FEM of the bridge can better represent its structural dynamics and serve as a baseline in long-term health monitoring, condition assessment and damage identification over the service life of the bridge .
基金National Natural Science Foundation of China under Grant Nos. 51725901 and 51639006。
文摘Modal parameters, including fundamental frequencies, damping ratios, and mode shapes, could be used to evaluate the health condition of structures. Automatic modal parameter identification, which plays an essential role in realtime structural health monitoring, has become a popular topic in recent years. In this study, an automatic modal parameter identification procedure for high arch dams is proposed. The proposed procedure is implemented by combining the densitybased spatial clustering of applications with noise(DBSCAN) algorithm and the stochastic subspace identification(SSI). The 210-m-high Dagangshan Dam is investigated as an example to verify the feasibility of the procedure. The results show that the DBSCAN algorithm is robust enough to interpret the stabilization diagram from SSI and may avoid outline modes. This leads to the proposed procedure obtaining a better performance than the partitioned clustering and hierarchical clustering algorithms. In addition, the errors of the identified frequencies of the arch dam are within 4%, and the identified mode shapes are in agreement with those obtained from the finite element model, which implies that the proposed procedure is accurate enough to use in modal parameter identification. The procedure is feasible for online modal parameter identification and modal tracking of arch dams.
文摘Analytical models prepared from field drawings do not generally provide results that match with experimental results.The error may be due to uncertainties in the property of materials,size of members and errors in the modelling process.It is important to improve analytical models using experimentally obtained data.For the past several years,data obtained from ambient vibration testing have been successfully used in many cases to update and match dynamic behaviors of analytical models with real structures.This paper presents a comparison between artificial neural network(ANN) and eigensensitivity based model updating of an existing multi-story building.A simple spring-mass analytical model,developed from the structural drawings of the building,is considered and the corresponding spring stiffness and lumped mass of all floors are chosen as updating parameters.The advantages and disadvantages of these updating methods are discussed.The advantage is that both methods ensure a physically meaningful model which canbe further employed in determining structural response and health monitoring.
基金Project(50678064) supported by the National Natural Science Foundation of China
文摘The effects of concrete's time-variant elastic modulus,casting structural components,assembling temporary shoring framework system,and shock by operating construction equipment on dynamic behavior of the reinforced concrete frame structure during construction were investigated. The dynamic tests of an eight-storey reinforced concrete frame structure during full-scaled stages of the sixth storey construction cycle were carried out by ambient vibration. Natural frequencies,corresponding mode shapes and damping ratio were determined by power spectrum processing the tested signal data in frequency domain. The changes of frequencies,mode shapes and damping ratios at different construction stages were given. The results show that natural frequencies and modal damping ratios reach the maximum at stage of casting fresh concrete,especially for higher modes. Modal damping ratios at each construction stage are less than 5% of those during usage.
基金Supported by:National Key Research and Development Program of China under Grant Nos.2016YFC0701400 and 2016YFC0701308the Key Research and Development Program of Hunan Province under Grant No.2017SK2220the National Natural Science Foundation of China(NSFC)under Grant No.51878264
文摘As a type of nonstructural component, infill walls play a significant role in the seismic behavior of high-rise buildings. However, the stiffness of the infill wall is generally either ignored or considered by simplified empirical criteria that lead to a period shortening. The difference can be greatly decreased by using a structural identification methodology. In this study, an ambient vibration test was performed on four on-site reinforced concrete high-rise buildings, and the design results were compared with the PKPM models using corresponding finite element(FE) models. A diagonal strut model was used to simulate the behavior of the infill wall, and the identified modal parameters measured from the on-site test were employed to calibrate the parameters of the diagonal strut in the FE models. The SAP2000 models with calibrated elastic modulus were used to evaluate the seismic response in the elastic state. Based on the load-displacement relationship of the infill wall, nonlinear dynamic analysis models were built in PERFORM-3 D and calibrated using the measured modal periods. The analysis results revealed that the structural performance under small/large earthquake records were both strengthened by infill walls, and the contribution of infill walls should be considered for better accuracy in the design process.
文摘In this review article,the past investigations carried out on heritage structures using Ambient Vibration Test(AVT)and Operational Modal Analysis(OMA)for system identification(determination of dynamic properties like frequency,mode shape and damping ratios)and associated applications are summarized.A total of 68 major research studies on heritage structures around the world that are available in literature are surveyed for this purpose.At first,field investigations carried out on heritage structures prior to conducting AVT are explained in detail.Next,specifications of accelerometers,location of accelerometers and optimization of accelerometer networks have been elaborated with respect to the geometry of the heritage structures.In addition to this,ambient vibration loads and data acquisition procedures are also discussed.Further,the state of art of performing OMA techniques for heritage structures is explained briefly.Furthermore,various applications of system identification for heritage structures are documented.Finally,conclusions are made towards errorless system identification of heritage structures through AVT and OMA.
基金This research is partially sponsored by the National Science Foundation,under grant number CMMI-0928095(Program Manager:Dr.Shih-Chi Liu).
文摘Being able to significantly reduce system installation time and cost,wireless sensing technology has attracted much interest in the structural health monitoring(SHM)community.This paper reports the field application of a wireless sensing system on a 4-span highway bridge located in Wayne,New Jersey in the US.Bridge vibration due to traffic and ambient excitation is measured.To enhance the signal-to-noise ratio,a low-noise high-gain signal conditioning module is developed for the wireless sensing system.Nineteen wireless and nineteen cabled accelerometers are first installed along the sidewalk of two neighboring bridge spans.The performance of the wireless sensing system is compared with the high-precision cabled sensing system.In the next series of testing,16 wireless accelerometers are installed under the deck of another bridge span,forming a 4×4 array.Operating deflection analysis is successfully conducted using the wireless measurement of traffic and ambient vibrations.
文摘Condition assessment of bridges has become increasingly important. In order to accurately simulate the real bridge, finite element (FE) model updating method is often applied. This paper presents the calibration of the FE model of a reinforced concrete tied-arch bridge using Douglas-Reid method in combination with Rosenbrock optimization algorithm. Based on original drawings and topographic survey, a FE model of the investigated bridge is created. Eight global modes of vibration of the bridge are identified by ambient vibration tests and the frequency domain decomposition technique. Then, eight structural parameters are selected for FE model updating procedure through sensitivity analysis. Finally, the optimal structural parameters are identified using Rosenbrock optimization algorithm. Results show that although the identified parameters lead to a perfect agreement between approximate and measured natural frequencies, they may not be the optimal variables which minimize the differences between numerical and experimental modal data. However, a satisfied agreement between them is still presented. Hence, FE model updating based on Douglas-Reid method and Rosenbrock optimization algorithm could be used as an alternative to other complex updating procedures.