Objective:Patients with ductal-dependent pulmonary circulation require alternative bloodflow to provide and maintain adequate oxygenation.Modified Blalock-Taussig Shunt(MBTS)has been the standard for providing such a ...Objective:Patients with ductal-dependent pulmonary circulation require alternative bloodflow to provide and maintain adequate oxygenation.Modified Blalock-Taussig Shunt(MBTS)has been the standard for providing such a result.Currently,less invasive methods such as Arterial Duct(AD)stenting have been performed as alter-natives.This study aims to compare the outcome of AD stenting and MBTS.Method:Systematic research was performed in online databases using the PRISMA protocol.The outcomes measured were 30-day mortality,com-plication,unplanned intervention,oxygen saturation,duration of hospital,and ICU length of stay.Any compara-tive study provided with full text is included.The outcome of each study was analyzed using a trandom effects model with relative risk and mean difference as the effect size.Bias risk assessment was conducted using the New-castle-Ottawa Scale.All analyses were performed using Review Manager 5.4.1.Result:A total of 11 studies with 3154 samples included in this study.There is no significant difference in 30-day mortality between the two groups(p-value=0.10).However,there is significantly less complication(RR 0.53[0.35,0.82];p-value=0.004)and unplanned intervention(RR 0.59[0.38,0.92];p-value=0.02)in the AD stent group.Comparison of the Nakata index showed no significant difference(p-value=0.88).Post-operative oxygen saturation was measured signifi-cantly higher in the AD stenting(MD 1.80[0.85,2.74];p-value=0.0002).However,AD stent group shows sig-nificantly lower long-term oxygen saturation(MD-8.43[-14.38,-2.48];p-value=0.005).Both hospital and ICU length of stay was significantly shorter in the AD stent group(MD-8.30[-11.13,-5.48];p-value<0.00001;MD-5.09[-7.79,-2.38];p-value=0.0002).Conclusion:AD stenting provides comparable outcomes relative to MBTS as it provides less complication and unplanned intervention and higher post-procedural O2 saturation.However,MBTS proved its superiority in maintaining higher long-term oxygen saturation and still became the preferred option to manage complex cases where stenting is either challenging or unsuccessful.展开更多
Objectives:To determine immediate and long-term follow-up of transcatheter closure of patent ductus arteriosus(PDA)in children.Background:National antibiotic prophylaxis(AP)guideline for infective endocarditis changed...Objectives:To determine immediate and long-term follow-up of transcatheter closure of patent ductus arteriosus(PDA)in children.Background:National antibiotic prophylaxis(AP)guideline for infective endocarditis changed after 2009,the effect on practice of PDA closure is unknown.Methods:Observational single center study analyzing follow-up of PDA closure comparing two time periods before(2002–2009)and after(2010–2019)changes in AP guideline.Results:332 patients(68.1%female),median(interquartile range)age 3.0 years(1.5–5.7)and body weight 14.0 kg(10.0–19.3),were enrolled.PDA morphology was conical type A(50.3%),window type B(1.2%),tubular type C(40.1%),complex type D(2.1%),elongated type E(0.9%)and other(5.4%).Minimal PDA diameter and length were 1.9 mm(1.3–2.5)and 8.0 mm(6.2–10.2).PDA was closed using coils(56.3%),Amplatzer Duct Occluders(41.9%)and others(1.8%).Complete closure rate was 61.1%at catheter intervention,72.3%on day 1,87.7%after 6 months and 98.4%at last follow-up on echocardiography.Moderate complication rate(severity level 3)was 4.2%and major complication rate(severity level 4)0.3%,with no catastrophic complications(severity level 5).Annual PDA closure rate declined in the second time period(22.6/year vs.15.5/year,p=0.018),PDA size increased(1.6 mm vs.2.0 mm,p=0.002)and proportion of coils decreased(72.4%vs.37.1%,p<0.001).Conclusions:Interventional closure of PDA is associated with excellent closure rates during follow-up(>98%)and only a small number of complications leading to reintervention or surgery.Change in AP guidelines changed indication for and practice of PDA closure.展开更多
We present a case of a one-day-old newborn,without prenatal diagnosis,referred to our cardiologic intensive care unit in critical condition presenting sub-cyanosis and peripheral oxygen saturation of 80%.Echocardiogra...We present a case of a one-day-old newborn,without prenatal diagnosis,referred to our cardiologic intensive care unit in critical condition presenting sub-cyanosis and peripheral oxygen saturation of 80%.Echocardiography diagnosis was tricuspid valve dysplasia with severe regurgitation,functional pulmonary valve atresia with intact ventricular septum and reversal flow in the large patent ductus arteriosus(PDA).Chest X-ray showed severe cardiomegaly and wall to wall heart.Prostaglandin E1 infusion was started once after birth.After few days,clinical conditions progressively worsened because of right heart failure;a first pharmacological approach to close PDA failed and surgery ligation of PDA was necessary to restore anterograde pulmonary flow and heart size.展开更多
Background: Liver transplantation has become the treatment of choice for patients with end-stage acute or chronic hepatic disease. Bile duct complications are common events after liver transplantation. The aim of thi...Background: Liver transplantation has become the treatment of choice for patients with end-stage acute or chronic hepatic disease. Bile duct complications are common events after liver transplantation. The aim of this study was to evaluate the blood supply of the human bile duct and identify the underlying mechanisms of bile duct complications after liver transplantation. Methods: The duct supply branches from gastroduodenal artery and blood supply of extrahepatic bile duct system were re-evaluated through selective hepatic angiography from 600 patients. In addition, 33 cadavers were injected with latex casting material into the common hepatic artery, then the extrahepatic bile duct and the branches from the common hepatic artery were carefully dissected to visualize the gastroduodenal artery and its branching to the extrahepatic bile duct. Results: The bile duct artery arose from the branch of the gastroduodenal artery in 8.1% (49/600). Of these 49 individuals, the bile duct artery was supplied by the gastroduodenal artery (61.22%, 30/49), the proper hepatic artery (14.29%, 7/49), or both the gastroduodenal artery and the proper hepatic artery (24.49%, 12/49). In our study of 33 cadavers, the percentage that the bile duct artery arose from the gastroduodenal artery was 27.27%. The blood supply to the bile extrahepatic bile ducts was divided into different segments and formed longitudinal and arterial network anastomosed on the walls of the duct. Conclusions: There is a close relationship between the duct supply branches from gastroduodenal artery and the blood supplying patterns of the extrahepatic bile duct system. In liver transplant surgery, the initial part of the gastroduodenal artery is preferred to be preserved in the donor liver. It is of great significance to improve the success rate of operation and reduce complications.展开更多
文摘Objective:Patients with ductal-dependent pulmonary circulation require alternative bloodflow to provide and maintain adequate oxygenation.Modified Blalock-Taussig Shunt(MBTS)has been the standard for providing such a result.Currently,less invasive methods such as Arterial Duct(AD)stenting have been performed as alter-natives.This study aims to compare the outcome of AD stenting and MBTS.Method:Systematic research was performed in online databases using the PRISMA protocol.The outcomes measured were 30-day mortality,com-plication,unplanned intervention,oxygen saturation,duration of hospital,and ICU length of stay.Any compara-tive study provided with full text is included.The outcome of each study was analyzed using a trandom effects model with relative risk and mean difference as the effect size.Bias risk assessment was conducted using the New-castle-Ottawa Scale.All analyses were performed using Review Manager 5.4.1.Result:A total of 11 studies with 3154 samples included in this study.There is no significant difference in 30-day mortality between the two groups(p-value=0.10).However,there is significantly less complication(RR 0.53[0.35,0.82];p-value=0.004)and unplanned intervention(RR 0.59[0.38,0.92];p-value=0.02)in the AD stent group.Comparison of the Nakata index showed no significant difference(p-value=0.88).Post-operative oxygen saturation was measured signifi-cantly higher in the AD stenting(MD 1.80[0.85,2.74];p-value=0.0002).However,AD stent group shows sig-nificantly lower long-term oxygen saturation(MD-8.43[-14.38,-2.48];p-value=0.005).Both hospital and ICU length of stay was significantly shorter in the AD stent group(MD-8.30[-11.13,-5.48];p-value<0.00001;MD-5.09[-7.79,-2.38];p-value=0.0002).Conclusion:AD stenting provides comparable outcomes relative to MBTS as it provides less complication and unplanned intervention and higher post-procedural O2 saturation.However,MBTS proved its superiority in maintaining higher long-term oxygen saturation and still became the preferred option to manage complex cases where stenting is either challenging or unsuccessful.
文摘Objectives:To determine immediate and long-term follow-up of transcatheter closure of patent ductus arteriosus(PDA)in children.Background:National antibiotic prophylaxis(AP)guideline for infective endocarditis changed after 2009,the effect on practice of PDA closure is unknown.Methods:Observational single center study analyzing follow-up of PDA closure comparing two time periods before(2002–2009)and after(2010–2019)changes in AP guideline.Results:332 patients(68.1%female),median(interquartile range)age 3.0 years(1.5–5.7)and body weight 14.0 kg(10.0–19.3),were enrolled.PDA morphology was conical type A(50.3%),window type B(1.2%),tubular type C(40.1%),complex type D(2.1%),elongated type E(0.9%)and other(5.4%).Minimal PDA diameter and length were 1.9 mm(1.3–2.5)and 8.0 mm(6.2–10.2).PDA was closed using coils(56.3%),Amplatzer Duct Occluders(41.9%)and others(1.8%).Complete closure rate was 61.1%at catheter intervention,72.3%on day 1,87.7%after 6 months and 98.4%at last follow-up on echocardiography.Moderate complication rate(severity level 3)was 4.2%and major complication rate(severity level 4)0.3%,with no catastrophic complications(severity level 5).Annual PDA closure rate declined in the second time period(22.6/year vs.15.5/year,p=0.018),PDA size increased(1.6 mm vs.2.0 mm,p=0.002)and proportion of coils decreased(72.4%vs.37.1%,p<0.001).Conclusions:Interventional closure of PDA is associated with excellent closure rates during follow-up(>98%)and only a small number of complications leading to reintervention or surgery.Change in AP guidelines changed indication for and practice of PDA closure.
文摘We present a case of a one-day-old newborn,without prenatal diagnosis,referred to our cardiologic intensive care unit in critical condition presenting sub-cyanosis and peripheral oxygen saturation of 80%.Echocardiography diagnosis was tricuspid valve dysplasia with severe regurgitation,functional pulmonary valve atresia with intact ventricular septum and reversal flow in the large patent ductus arteriosus(PDA).Chest X-ray showed severe cardiomegaly and wall to wall heart.Prostaglandin E1 infusion was started once after birth.After few days,clinical conditions progressively worsened because of right heart failure;a first pharmacological approach to close PDA failed and surgery ligation of PDA was necessary to restore anterograde pulmonary flow and heart size.
文摘Background: Liver transplantation has become the treatment of choice for patients with end-stage acute or chronic hepatic disease. Bile duct complications are common events after liver transplantation. The aim of this study was to evaluate the blood supply of the human bile duct and identify the underlying mechanisms of bile duct complications after liver transplantation. Methods: The duct supply branches from gastroduodenal artery and blood supply of extrahepatic bile duct system were re-evaluated through selective hepatic angiography from 600 patients. In addition, 33 cadavers were injected with latex casting material into the common hepatic artery, then the extrahepatic bile duct and the branches from the common hepatic artery were carefully dissected to visualize the gastroduodenal artery and its branching to the extrahepatic bile duct. Results: The bile duct artery arose from the branch of the gastroduodenal artery in 8.1% (49/600). Of these 49 individuals, the bile duct artery was supplied by the gastroduodenal artery (61.22%, 30/49), the proper hepatic artery (14.29%, 7/49), or both the gastroduodenal artery and the proper hepatic artery (24.49%, 12/49). In our study of 33 cadavers, the percentage that the bile duct artery arose from the gastroduodenal artery was 27.27%. The blood supply to the bile extrahepatic bile ducts was divided into different segments and formed longitudinal and arterial network anastomosed on the walls of the duct. Conclusions: There is a close relationship between the duct supply branches from gastroduodenal artery and the blood supplying patterns of the extrahepatic bile duct system. In liver transplant surgery, the initial part of the gastroduodenal artery is preferred to be preserved in the donor liver. It is of great significance to improve the success rate of operation and reduce complications.