A novel green nanophosphor CaHPO4:Tb3+ was synthesized via a room-temperatureco-precipitation route driven by ethanol solvent. X-ray powder diffraction (XRD), scanningelectron microscopy (SEM) and photoluminesce...A novel green nanophosphor CaHPO4:Tb3+ was synthesized via a room-temperatureco-precipitation route driven by ethanol solvent. X-ray powder diffraction (XRD), scanningelectron microscopy (SEM) and photoluminescence spectroscopy (PL) techniques were utilizedto characterize the structure, morphology and fluorescence performance of the obtained powders.The results demonstrated that the prepared samples were well crystallized with triclinic phaseCaHPO4 structure and particle-like morphology. Photoluminescence measurements indicated thatCaHPOa:Tb3+ had a strong absorption peak at 370 nm and exhibited characteristic emissions withseveral sharp peaks corresponding to the transitions 5D4-7FJ (jr = 6-3) of Tb3+. Moreover, theluminescence optimum concentration for CaHPO4:Tb3+ was determined to be 11 mol%, whichmight be a promising green-emitting ohosohor for display applications.展开更多
Introduction: Infra-red (IR) thermometry is a safe and valid method to determine internal and surface temperature in human subjects. Under conditions of brain damage (head injury or stroke) knowledge of changes in the...Introduction: Infra-red (IR) thermometry is a safe and valid method to determine internal and surface temperature in human subjects. Under conditions of brain damage (head injury or stroke) knowledge of changes in the temperature of intracranial tissue is justified because of the vulnerability of neurons to accelerated damage at temperatures at the upper end of the febrile range. Aim: To determine the temperature at the inner canthus (IC) of the eye as a potential surrogate for brain temperature. Methods: Invasive monitoring of deep brain structures, lateral ventricle and deep white matter. IR temperature readings obtained at right and left IC. Results: ?Strong correlations were evident between R and L IC and brain. Close, as well as poor, agreement between?? sites was shown in some patients and at some times. For right hemispheric lesions four had a better correlation between TbrV and TRIC when compared to TLIC.? When the correlation between TbrV and TLIC was better compared to TbrV and TRIC, four had a predominant right hemispheric lesion. Conclusions: Improved techniques for IR thermal imaging accuracy at the bedside has the potential to improve temperature measurement agreement. The predominant lesion side may have a bearing on maximum ipsilateral IC temperature Further studies are ongoing in this pilot study population.展开更多
HY-2A is the first one of the Chinese HY-2 ocean satellite series carrying a microwave radiometer(RM)to measure sea surface temperature,sea surface wind speed,atmospheric water vapor,cloud liquid water content,and rai...HY-2A is the first one of the Chinese HY-2 ocean satellite series carrying a microwave radiometer(RM)to measure sea surface temperature,sea surface wind speed,atmospheric water vapor,cloud liquid water content,and rain rate.We verified the RM level 1B brightness temperature(T B)to retrieve environmental parameters.In the verification,TB that simulated using the ocean-atmosphere radiative transfer model(RTM)was used as a reference.The total bias and total standard deviation(SD)of the RM level 1B TB,with reference to the RTM simulation,ranged-20.6-4.38 K and 0.7-2.93 K,respectively.We found that both the total bias and the total SD depend on the frequency and polarization,although the values for ascending and descending passes are different.In addition,substantial seasonal variation of the bias was found at all channels.The verification results indicate the RM has some problems regarding calibration,e.g.,correction of antenna spillover and antenna physical emission,especially for the 18.7-GHz channel.Based on error analyses,a statistical recalibration algorithm was designed and recalibration was performed for the RM level 1B TB.Validation of the recalibrated TB indicated that the quality of the recalibrated RM level 1B TB was improved significantly.The bias of the recalibrated T B at all channels was reduced to<0.4 K,seasonal variation was almost eradicated,and SD was diminished(i.e.,the SD of the 18.7-GHz channel was reduced by more than 0.5K).展开更多
基金supported by the National Natural Science Foundation of China(21663021)China Postdoctoral Science Foundation(2015M571977)+1 种基金the Natural Science Foundation of Jiangxi Province(20161BAB213058)the Natural Science Key Project of Jiangxi Province(2017ACB20040)
文摘A novel green nanophosphor CaHPO4:Tb3+ was synthesized via a room-temperatureco-precipitation route driven by ethanol solvent. X-ray powder diffraction (XRD), scanningelectron microscopy (SEM) and photoluminescence spectroscopy (PL) techniques were utilizedto characterize the structure, morphology and fluorescence performance of the obtained powders.The results demonstrated that the prepared samples were well crystallized with triclinic phaseCaHPO4 structure and particle-like morphology. Photoluminescence measurements indicated thatCaHPOa:Tb3+ had a strong absorption peak at 370 nm and exhibited characteristic emissions withseveral sharp peaks corresponding to the transitions 5D4-7FJ (jr = 6-3) of Tb3+. Moreover, theluminescence optimum concentration for CaHPO4:Tb3+ was determined to be 11 mol%, whichmight be a promising green-emitting ohosohor for display applications.
文摘Introduction: Infra-red (IR) thermometry is a safe and valid method to determine internal and surface temperature in human subjects. Under conditions of brain damage (head injury or stroke) knowledge of changes in the temperature of intracranial tissue is justified because of the vulnerability of neurons to accelerated damage at temperatures at the upper end of the febrile range. Aim: To determine the temperature at the inner canthus (IC) of the eye as a potential surrogate for brain temperature. Methods: Invasive monitoring of deep brain structures, lateral ventricle and deep white matter. IR temperature readings obtained at right and left IC. Results: ?Strong correlations were evident between R and L IC and brain. Close, as well as poor, agreement between?? sites was shown in some patients and at some times. For right hemispheric lesions four had a better correlation between TbrV and TRIC when compared to TLIC.? When the correlation between TbrV and TLIC was better compared to TbrV and TRIC, four had a predominant right hemispheric lesion. Conclusions: Improved techniques for IR thermal imaging accuracy at the bedside has the potential to improve temperature measurement agreement. The predominant lesion side may have a bearing on maximum ipsilateral IC temperature Further studies are ongoing in this pilot study population.
基金Supported by the National Key Research and Development Program of China(No.2016YFC1401001)the National Natural Science Foundation of China(Nos.41501417,41406204)
文摘HY-2A is the first one of the Chinese HY-2 ocean satellite series carrying a microwave radiometer(RM)to measure sea surface temperature,sea surface wind speed,atmospheric water vapor,cloud liquid water content,and rain rate.We verified the RM level 1B brightness temperature(T B)to retrieve environmental parameters.In the verification,TB that simulated using the ocean-atmosphere radiative transfer model(RTM)was used as a reference.The total bias and total standard deviation(SD)of the RM level 1B TB,with reference to the RTM simulation,ranged-20.6-4.38 K and 0.7-2.93 K,respectively.We found that both the total bias and the total SD depend on the frequency and polarization,although the values for ascending and descending passes are different.In addition,substantial seasonal variation of the bias was found at all channels.The verification results indicate the RM has some problems regarding calibration,e.g.,correction of antenna spillover and antenna physical emission,especially for the 18.7-GHz channel.Based on error analyses,a statistical recalibration algorithm was designed and recalibration was performed for the RM level 1B TB.Validation of the recalibrated TB indicated that the quality of the recalibrated RM level 1B TB was improved significantly.The bias of the recalibrated T B at all channels was reduced to<0.4 K,seasonal variation was almost eradicated,and SD was diminished(i.e.,the SD of the 18.7-GHz channel was reduced by more than 0.5K).