期刊文献+
共找到178,347篇文章
< 1 2 250 >
每页显示 20 50 100
Determination of Benzo[a]pyrene in Edible Oil by High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FL)
1
作者 Guixia YANG Jie LIU +3 位作者 Xiujuan WANG Fenglan ZHANG Kun XIN Chunli KONG 《Agricultural Biotechnology》 2024年第2期8-9,19,共3页
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc... In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil. 展开更多
关键词 BENZO[A]PYRENE High performance liquid chromatography Fluorescence detector
下载PDF
Determination of Stereoisomers of Epalrestat by Liquid Chromatography 被引量:1
2
作者 齐美玲 王鹏 杨建军 《Journal of Beijing Institute of Technology》 EI CAS 2004年第4期445-448,共4页
An isocratic reversed-phase liquid chromatographic (LC) method is described for the determination of epalrestat and its three stereoisomers (degradation impurities) in drug substance. The LC separation system consiste... An isocratic reversed-phase liquid chromatographic (LC) method is described for the determination of epalrestat and its three stereoisomers (degradation impurities) in drug substance. The LC separation system consisted of a Hypersil C18 column (250 mm×4.6 mm, 5 μm) with a mobile phase comprising methanol, acetonitrile and water (volume ratio 60∶1∶50, pH 4.5) delivered at a flow rate of 1.6 mL/min and UV detection at 280 nm. The proposed LC method is simple and selective for the determination of the stereoisomers of epalrestat in the drug substance with a limit of detection and quantification of 3.9 μg/mL and 4.9 μg/mL, respectively. The stereoisomers were identified by liquid chromatography-mass spectrometry (LC-MS). 展开更多
关键词 liquid chromatography EPALRESTAT STEREOISOMERS
下载PDF
Efficient and selective extraction of uranium from seawater based on a novel pulsed liquid chromatography radionuclide separation method 被引量:2
3
作者 Jian‑Hua Ye Tao Yu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第2期13-27,共15页
The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation met... The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation method was proposed,and a pulsed nuclide automated separation device was developed,alongside a new chromatographic column.The length of this chromatographic column was 10 m,with an internal warp of 3 mm and a packing size of 1 mm,while the total separation units of the column reached 12,250.The most favorable conditions for the separation of nuclides were then obtained through optimizing the separation conditions of the device:Sample pH in the column=2,sample injection flow rate=5.698 mL/min,chromatographic column heating temperature=60℃.Separation experiments were also carried out for uranium,europium,and sodium ions in mixed solutions;uranium and sodium ions in water samples from the Ganjiang River;and uranium,sodium,and magnesium ions from seawater samples.The separation factors between the different nuclei were then calculated based on the experimental data,and a formula for the separation level was derived.The experimental results showed that the separation factor in the mixed solution of uranium and europium(1:1)was 1.088,while achieving the initial separation of uranium and europium theoretically required a 47-stage separation.Considering the separation factor of 1.50for the uranium and sodium ions in water samples from the Ganjiang River,achieving the initial separation of uranium and sodium ions would have theoretically required at least a 21-stage separation.Furthermore,for the seawater sample separation experiments,the separation factor of uranium and sodium ions was 1.2885;therefore,more than 28 stages of sample separation would be required to achieve uranium extraction from seawater.The novel pulsed liquid chromatography method proposed in this study was innovative in terms of uranium separation and enrichment,while expanding the possibilities of extracting uranium from seawater through chromatography. 展开更多
关键词 Pulsed liquid chromatography Nuclide separation Seawater uranium extraction Uranium enrichment
下载PDF
Determination of 14 Organophosphorus Pesticide Residues in Mutton by Gel Permeation Chromatography-Gas Chromatography-Mass Spectrometry(GPC-GC-MS)
4
作者 Junpeng ZHAO Richard Avoi +2 位作者 Azman Bin Atil@Azmi Jiao CHEN Ling YUN 《Agricultural Biotechnology》 2024年第3期28-30,33,共4页
[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by ga... [Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton. 展开更多
关键词 MUTTON Gas chromatography-mass spectrometry Gel permeation chromatography ORGANOPHOSPHORUS Pesticide residue
下载PDF
Determination of Veterinary Drug Residues in Animal-derived Foods by Liquid Chromatography-Mass Spectrometry 被引量:2
5
作者 Haowei CUI Kun XIN Guixia YANG 《Agricultural Biotechnology》 CAS 2023年第1期84-86,93,共4页
[Objectives]This study was conducted to establish a rapid and effective method for simultaneous extraction of 54 kinds of veterinary drug residues in animal-derived food, including sulfonamides, quinolones, tetracycli... [Objectives]This study was conducted to establish a rapid and effective method for simultaneous extraction of 54 kinds of veterinary drug residues in animal-derived food, including sulfonamides, quinolones, tetracyclines, malachite greens, penicillins, nitroimidazoles, tranquilizers and macrolides, by HPLC-MS. [Methods] The samples were extracted with 80% acetonitrile water(containing 0.1% formic acid), combined with QuEChERS extraction technology and C18 and PSA purification, analyzed by high performance liquid chromatography-mass spectrometry, and quantified by external standard method. The target substances were analyzed on ZORBAX Eclipse C18 chromatographic column using 0.2% formic acid water and 0.2% methanol as mobile phases. The gradient elution mode was used for chromatographic separation and multiple reaction detection. [Results] In the linear range of 0.5-50.0 ng/ml, the linear relationship of the 54 kinds of veterinary drug residues was good, with correlation coefficients(r~2) greater than 0.995, and the detection limits ranged from 0.30 to 1.00 μg/kg. The results showed that the recovery ranged from 75.4% to 118.2% when different matrixes were added for recovery. [Conclusions] This method is simple, efficient, accurate, stable, and highly operable. It is applicable to simultaneous batch screening of veterinary drug residues in animal-derived food, and has high practical application value. 展开更多
关键词 Animal-derived food Multiple veterinary drug residues OPTIMIZATION liquid chromatography-mass spectrometry
下载PDF
Determination of Voriconazole in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry: Application in Therapeutic Drug Monitoring
6
作者 Waleed Alhussaini Ezzeldeen Ghanem +4 位作者 Magd Alsahly Amani Kurdi Eman Alharbi Imadul Islam Majed Aljeraisy 《American Journal of Analytical Chemistry》 2023年第9期378-389,共12页
A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with flucona... A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM. 展开更多
关键词 VORICONAZOLE Human Plasma liquid chromatography Tandem Mass Spectrometry Therapeutic Drug Monitoring
下载PDF
A High-Performance Liquid Chromatography Method for the Simultaneous Determination of Five Index Components in Danhong Injection
7
作者 Yun An Tian Tian +2 位作者 Qinglin Wang Xingchu Gong Chenchen Wang 《American Journal of Analytical Chemistry》 CAS 2023年第11期481-492,共12页
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a... The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R2> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. 展开更多
关键词 Danhong Injection High Performance liquid chromatography Phenolic Acid FLAVONOIDS
下载PDF
Determination of egg and milk allergen in food products by liquid chromatography-tandem mass spectrometry based on signature peptides and isotope-labeled internal standard
8
作者 Sufang Fan Junmei Ma +4 位作者 Zhuo Liu Yawei Ning Meicong Cao Qiang Li Yan Zhang 《Food Science and Human Wellness》 SCIE CSCD 2023年第3期728-736,共9页
The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLD... The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLDTDYK,FFVAPFPEVFGK,and NAVPITPTLNR were confirmed and synthesized as the quantitative peptide of ovalbumin,α-lactalbumin,β-lactoglobulin,α_(S1)-casein andα_(S2)-casein,the relative isotope-labeled internal standards were used in the quantitative analysis.Linear range was in the range of0.5-5000.0 nmol/L for egg and milk allergen in bread,cake,cookie,rice crust and wheat flour samples with free from egg and milk,the limits of detection of milk allergens and egg allergen were in the range between0.94 mg/100 g and 56.71 mg/100 g,limits of quantification of milk allergens and egg allergen were in the range between 2.36 mg/100 g and 141.78 mg/100 g.The recoveries ranged from 76.7%to 122.8%,the relative standard deviations were in the range of 1.60%-15.60%.The developed method has been successfully used for the detection of egg and milk allergen in various food samples. 展开更多
关键词 liquid chromatography-tandem mass spectrometry Egg and milk allergen Signature peptides Isotope-labeled internal standards
下载PDF
Simultaneous Determination of 14 β-Receptor Agonists Residues in Mutton by High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)
9
作者 Zhe MENG Jianhua WANG +5 位作者 Bo LIU Yuhang GUO Haoshuang DONG Pingyang SHAN Dawei WANG Yajuan SONG 《Agricultural Biotechnology》 CAS 2023年第5期55-58,共4页
[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-g... [Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton. 展开更多
关键词 MUTTON High performance liquid chromatography-tandem mass spectrometry β-receptor agonist RESIDUE
下载PDF
Simultaneous purification of minor components in natural products using twin-column recycling chromatography with a step solvent gradient
10
作者 Guangxia Jin Yuxue Wu Feng Wei 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第5期212-219,共8页
The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar co... The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar compounds.This study introduces an optimized twin-column recycling chromatography method for the efficient and simultaneous purification of these elusive constituents.By introducing water at a small flowing rate between the twin columns,a step solvent gradient is created,by which the leading edge of concentration band would migrate at a slower rate than the trailing edge as it flowing from the upstream to downstream column.Hence,the band broadening is counterbalanced,resulting in an enrichment effect for those minor components in separation process.Herein,two target substances,which showed similar peak position in high performance liquid chromatography(HPLC)and did not exceed 1.8%in crude paclitaxel were selected as target compounds for separation.By using the twin-column recycling chromatography with a step solvent gradient,a successful purification was achieved in getting the two with the purity almost 100%.We suggest this method is suitable for the separation of most components in natural produces,which shows higher precision and recovery rate compared with the common lab-operated separation ways for natural products(thin-layer chromatography and prep-HPLC). 展开更多
关键词 Solvent gradient Twin-column recycling chromatography PURIFICATION Minor component Natural products
下载PDF
Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
11
作者 Pan Lijing Chen Weiwei Yuan Minjia 《China Detergent & Cosmetics》 CAS 2023年第4期30-36,共7页
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte... An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics. 展开更多
关键词 ultra performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS) OLEUROPEIN COSMETICS
下载PDF
Comprehensive analysis of phenolic composition and antioxidant mechanisms in Gymnema sylvestre extracts using LC-MS and column chromatography
12
作者 Shengjie Hao Yuxin Du +2 位作者 Jianglong He Qian Li Guilin Chen 《Asian Journal of Traditional Medicines》 2024年第4期211-222,共12页
Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant propertie... Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant properties of Gymnema sylvestre extracts.Ethanolic reflux extraction followed by column chromatography was employed to isolate phenolic compounds.The total phenolic and flavonoid contents were quantified using the Folin–Ciocalteu and aluminum chloride colorimetric methods,respectively.Antioxidant activities were assessed by DPPH,ABTS scavenging assays and the ferric reducing antioxidant power(FRAP)assay.High-Performance Liquid Chromatography(HPLC)with a C18 column and Thermo TSQ Quantum Access Max(LC-MS)were used to determine the levels of gymnemic acid and identify other potential phenolic compounds.The analysis revealed significant antioxidant activities in the fractions.Fraction A showed the highest DPPH and ABTS scavenging activities,and Fraction C demonstrated the highest ferric reducing power.LC-MS analysis identified several phenolic compounds,indicating that these are major contributors to the antioxidant efficacy of the extract.This study provides a detailed phenolic profile and confirms the strong antioxidant potential of Gymnema sylvestre leaf extract,supporting its therapeutic use and further investigation. 展开更多
关键词 Gymnema sylvestre ANTIOXIDANTS column chromatography phenolic compounds LC-MS
下载PDF
Simultaneous Determination of Tetramethylpyrazine and Aspirin in a New Compound Formulation by Liquid Chromatography 被引量:2
13
作者 王鹏 齐美玲 +1 位作者 周莉 方林 《Journal of Chinese Pharmaceutical Sciences》 CAS 2004年第1期58-62,共5页
Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two d... Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two drugs was achieved on a Diamonsil C_(18) column, usinga binary mixture of methanol-1.5% acetic acid (35:65, V/V, pH = 3.1) as mobile phase at a flow rateof 1.0 mL·min^(-1). Results Separation was completed in less than 12 min. Benzoic acid was used asthe internal standard. Recoveries at levels corresponding to 80 % to 120 % of the label claim ofthe formulation ranged from 99.6 to 100.3 % for aspirin and from 99.9 to 101.3% for TMP. The linearrange was 12.6 - 150.9 μg·mL^(-1)(r= 0.9997, n = 5) for aspirin and 25.0- 300.0 μg·mL^(-1) (r =0.9999, n = 5) for TMP. Conclusion The method developed can be used for the simultaneousdetermination of TMP and aspirin in pharmaceutical preparations. 展开更多
关键词 liquid chromatography TETRAMETHYLPYRAZINE ASPIRIN ASSAY
下载PDF
High Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometric Analysis of Bilobalide and Ginkgolides in Ginkgo biloba L. Leaves 被引量:1
14
作者 卢定强 韦萍 +1 位作者 欧阳平凯 陈钧 《Journal of Chinese Pharmaceutical Sciences》 CAS 2002年第2期26-30,共5页
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi... The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy. 展开更多
关键词 High performance liquid chromatography Electrospray ionization Mass spectrometry Ginkgo terpene lactones
下载PDF
Studies on Chromatography Fingerprint of Hongqi by High-performance Liquid Chromatography 被引量:2
15
作者 ShiLanFENG FangDiHU +2 位作者 JianXiongZHAO JingWenXU LiRenCHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第11期1335-1338,共4页
Chromatography fingerprint (CFP) of 10 samples of hongqi were studied. 23 common peaks were analyzed, their average similarity was 97.29%. CFP were positioned with main index composition such as formononetin, calyco... Chromatography fingerprint (CFP) of 10 samples of hongqi were studied. 23 common peaks were analyzed, their average similarity was 97.29%. CFP were positioned with main index composition such as formononetin, calycosin and then the contents of index composition were determined. The character and exclusive of CFP of 10 samples of hongqi were clear. CFP and content determination of index composition of hongqi could be used to evaluate the quality of hongqi comprehensively. 展开更多
关键词 Hongqi chromatography fingerprint high-performance liquid chromatography.
下载PDF
Simultaneous determination of 15 pesticide residues in Chinese cabbage and cucumber by liquid chromatography-tandem mass spectrometry utilizing online turbulent flow chromatography 被引量:5
16
作者 Sufang Fan Junmei Ma +5 位作者 Meirong Cao Juan Wang Leilei Zhang Yan Zhang Qiang Li Jia Chen 《Food Science and Human Wellness》 SCIE 2021年第1期78-86,共9页
In this experiment,a liquid chromatography tandem mass spectrometry method was built to determine 15 pesticide residues in Chinese cabbage and cucumber samples based on online turbulent flow chromatography purificatio... In this experiment,a liquid chromatography tandem mass spectrometry method was built to determine 15 pesticide residues in Chinese cabbage and cucumber samples based on online turbulent flow chromatography purification.After modified quick,easy,cheap,effective,rugged,and safe(QuEChERS)extraction,extracts were directly injected to the TLX(TurboFlow Liquid Xcalibur)system and brought to TurboFlow™columns for on-line purification and then transferred to analytical column for further separation and analysis.TurboFlow™columns types,transfer flow rate,and transfer time were optimized.Limits of detection and limits of quantification of the method obtained for 15 pesticide residues were ranged between 0.2–1.0μg/kg and 0.5–2.0μg/kg in Chinese cabbage and cucumber samples.Recoveries of pesticide residues were in range of 75.3%–103.7%.Matrix effects for 15 pesticides were in range of 5.6%–106.6%.The developed method has been successfully used for the determination of 15 pesticide residues in real samples. 展开更多
关键词 Pesticide residues Online turbulent flow chromatography liquid chromatography-tandem mass SPECTROMETRY
下载PDF
Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods 被引量:1
17
作者 Cheng-Ping Li1,2,Mao Mao1,Lan-Jun Zheng1,Wei-Guang Shan11.College of Pharmaceutical Sciences,Zhejiang University of Technology,Hangzhou 310032 2.College of Biology and Environment Engineering,Zhejiang Shuren University,Hangzhou 310015,China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第4期218-222,共5页
Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 co... Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine. 展开更多
关键词 GANCICLOVIR related substances high performance liquid chromatography high performance liquid chromatography/mass spectrometry
下载PDF
Determination of Steroid Hormone Residues in Fish Tissues Using Gel Permeation Chromatography and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:3
18
作者 LI Peipei YAN Zhongyong +3 位作者 SUN Xiumei CHEN Si CHEN Yin ZHANG Xiaojun 《Journal of Ocean University of China》 SCIE CAS CSCD 2018年第5期1171-1177,共7页
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s... A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues. 展开更多
关键词 ultra performance liquid chromatography-tandem mass spectrometry anabolic hormone gel permeation chromatography fish tissue
下载PDF
Comparison of liquid-liquid extraction-thin layer chromatography with solid-phase extraction-high-performance thin layer chromatography in detection of urinary morphine 被引量:1
19
作者 Ali Ahadi Alireza Partoazar +1 位作者 Mohammad Hassan Abedi Khorasgani Seyed Vahid Shetab Boushehri 《The Journal of Biomedical Research》 CAS 2011年第5期362-367,共6页
Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tr... Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tra- ditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as mor- phine-positive samples by a strip test, 'were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories. 展开更多
关键词 morphine detection liquid-liquid extraction thin-layer chromatography solid-phase extraction highperformance thin layer chromatography
下载PDF
Determination of trans-resveratrol in mouse liver by high performance liquid chromatography
20
作者 姚倩 侯世祥 +3 位作者 何希辉 张瑄 颜军 苟小军 《Journal of Chinese Pharmaceutical Sciences》 CAS 2008年第2期158-162,共5页
To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted ... To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted by ethyl acetate. The organic layer was isolated and evaporated to dryness, the residue was reconstituted in 0.2 mL mobile phase for centrifugation, and 50 uL of the supernatant was injected into the/-IPLC instrument. The sample was separated on a Shimadzu ODS column (150 mm × 4.6 mm, 5 um) at 35 ℃ and detected by ultraviolet (UV) detector at the wavelength of 305 nm. The mobile phase consisted of methanol and 0.1 mol/L acetic acid (4:6, v/v) with the flow-rote at 1 mL/min. The limit of detection was 3.0 ng/g in liver homogenate with a signal/noise ratio of 3:1. The linear range of the calibration curve was 5.0-120.0 ng/g. The mean recoveries at the concentrations of 6, 10 and 80 ng/g were 102%, 96.0% and 91.5%, respectively. The RSDs for inter- and intra-day assays were less than 5%. Compared with other reported methods, this method was faster and more sensitive. It was also proved to be of good linearity, selectivity, accuracy and precision, and can be efficiently applied to the pharmacoldnetic study of trans-resveratrol in mouse liver. 展开更多
关键词 High performance liquid chromatography TRANS-RESVERATROL Mouse liver
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部