期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
CONSTRUCTION OF COMPACTLY SUPPORTED BIVARIATE ORTHOGONAL WAVELETS BY UNIVARIATE ORTHOGONAL WAVELETS 被引量:4
1
作者 杨建伟 李落清 唐远炎 《Acta Mathematica Scientia》 SCIE CSCD 2005年第2期233-242,共10页
After some permutation of conjugate quadrature filter, new conjugate quadrature filters can be derived. In terms of this permutation, an approach is developed for constructing compactly supported bivariate orthogonal ... After some permutation of conjugate quadrature filter, new conjugate quadrature filters can be derived. In terms of this permutation, an approach is developed for constructing compactly supported bivariate orthogonal wavelets from univariate orthogonal wavelets. Non-separable orthogonal wavelets can be achieved. To demonstrate this method, an example is given. 展开更多
关键词 PERMUTATION non-separable wavelets conjugate quadrature filter
下载PDF
A CRITERION FOR ORTHOGONALITY OF REFINABLE FUNCTIONS
2
作者 BiNing HuangDaren 《Applied Mathematics(A Journal of Chinese Universities)》 SCIE CSCD 2001年第4期397-401,共5页
In this note, a criterion for orthonormality of refinable functions via characteristic polynomial of a matrix is given.
关键词 Refinable function ORTHOGONALITY conjugate quadrature filter characteristic polynomial.
下载PDF
Research on Multi-Component Gas Optical Detection System Based on Conjugated Interferometer
3
作者 Xin GUI Yuheng TONG +2 位作者 Honghai WANG Haihu YU Zhengying LI 《Photonic Sensors》 SCIE EI CAS CSCD 2017年第3期261-269,共9页
An optical multi-component gas detection system based on the conjugated interferometer (CI) is proposed and experimentally demonstrated. It can realize the concentration detection of mixture gas in the environment. ... An optical multi-component gas detection system based on the conjugated interferometer (CI) is proposed and experimentally demonstrated. It can realize the concentration detection of mixture gas in the environment. The CI can transform the absorption spectrum of the target gases to a conjugated emission spectrum, when combining the CI with the broadband light source, the spectrum of output light matches well with the absorption spectrum of target gases. The CI design for different target gases can be achieved by replacing the kind of target absorbing gas in the CI filter. The traditional fiber gas sensor system requires multiple light sources for detection when there are several kinds of gases, and this problem has been solved by using the CI filter combined with the broadband light source. The experimental results show that the system can detect the concentration of multi-component gases, which are mixed with C2H2 and NH3. Experimental results also show a good concentration sensing linearity. 展开更多
关键词 Gas conjugated interference filter gas sensing spectral absorption
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部