期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
CUTTING REGULARITY AND DISCHARGE CHARACTERISTICS BY USING COMPOSITE COOLING LIQUID IN WIRE CUT ELECTRICAL DISCHARGE MACHINE WITH HIGH WIRE TRAVELING SPEED 被引量:11
1
作者 LIU Zhidong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第5期41-45,共5页
The analysis of cutting regularity is provided through using and comparing two typical cooling liquids. It is proved that cutting regularity is greatly affected by cooling liquid's washing ability. Discharge characte... The analysis of cutting regularity is provided through using and comparing two typical cooling liquids. It is proved that cutting regularity is greatly affected by cooling liquid's washing ability. Discharge characteristics and theoretic analysis between two electrodes are also discussed based on discharge waveform. By using composite cooling liquid which has strong washing ability, the efficiency in the first stable cutting phase has reached more than 200 mm^2/min, and the roughness of the surface has reached Ra〈0.8 μm after the fourth cutting with more than 50 mm^2/min average cutting efficiency. It is pointed out that cutting situation of the wire cut electrical discharge machine with high wire traveling speed (HSWEDM) is better than the wire cut electrical discharge machine with low wire traveling speed (LSWEDM) in the condition of improving the cooling liquid washing ability. The machining indices of HSWEDM will be increased remarkably by using the composite cooling liquid. 展开更多
关键词 Wire cut electrical discharge machine with high wire traveling speed Composite cooling liquid Discharge characteristic Cutting regularity
下载PDF
THE STRUCTURE AND PERFORMANCES OF THE LARGE DIMEMENSION STEEL BALL MADEOF 45 STEEL QUENCHED AFTER FORGING
2
作者 G.L.Huang Department of Materials Engineering, Jiangsu University of Science and Technology, Zhenjiang 212013, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1999年第5期845-848,共4页
The structure and performances of the large dimension steel ball made of 45 steel quenched after forging have been researched. The experiments indicate that the optimum results can be obtained under proper pro... The structure and performances of the large dimension steel ball made of 45 steel quenched after forging have been researched. The experiments indicate that the optimum results can be obtained under proper processes. 展开更多
关键词 quenched after forging cooling speed structure and performances
下载PDF
Effect of cooling pad installation on indoor airflow distribution in a tunnel-ventilated laying-hen house 被引量:4
3
作者 Hui Xue Zhu Qiang +4 位作者 Ji-Qin Ni Li Baoming Shi Zhengxiang Zhao Shumei Wang Yu 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2016年第4期169-177,共9页
Extra cooling pads on the sidewalls are needed for larger poultry houses using tunnel ventilation system.Preliminary study showed that the airflow velocity going through different aisles varies greatly when the extra ... Extra cooling pads on the sidewalls are needed for larger poultry houses using tunnel ventilation system.Preliminary study showed that the airflow velocity going through different aisles varies greatly when the extra pads are installed at the end of sidewalls,making a“[”-shape air inlet.Combined with field tests,the CFD(computational fluid dynamics)technology was used to study the uniformity of airflow distribution in a tunnel-ventilated laying-hen house.The air distribution was first monitored in a layer house to find the main reason resulting in the variations of airflows in different aisles.Then CFD simulations were carried out with different distances(D=2 m,3 m or 4 m)between the pads on end-wall and the extra pads on side walls.The field test showed that airflow streams from the different groups of cooling pads collided vertically at the house corners,mixed with each other,then flew towards the center of the house.This was the main reason that the wind speed in the middle aisle was much higher than in other aisles,leaving large zones of lower ventilation in the aisles adjacent to the sidewalls.The results of CFD simulations indicated that air distributions could be significantly improved when the extra pieces of pads were moved away for an appropriate distance from the end coolingpads.As far as conventional poultry house with a span of 12 m,the air speeds in different aisles were more uniform when this distance was about 3 m. 展开更多
关键词 Pad cooling system air distribution air speed laying-hen house CFD
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部