Differential pulse cathodic stripping voltammetry was used to determine pesticide metsulfuron-methyl on a suspended mercury electrode.Specific experimental parameters,such as the pH of Britton-Robinson buffer,accumula...Differential pulse cathodic stripping voltammetry was used to determine pesticide metsulfuron-methyl on a suspended mercury electrode.Specific experimental parameters,such as the pH of Britton-Robinson buffer,accumulation time,accumulation potential,and initial potential were optimized.The results show that a typical reduction peak appeared when pH was 2.0-4.0 and initial potential ranged from-0.75 to-1.0 V.To obtain the stripping signal of the best reduction peak,it is determined that the best pH was 2.0.The detection limit of the method was only 0.04 mg/L,and it had good selectivity and high accuracy,so the method has high sensitivity.In the analysis of actual drinking water,the recovery rate of metsulfuron-methyl could reach 93%-101%.展开更多
An electrochemical flow device has been developed for the determination of heavy metal ions(HMI)in water using multiwalled carbon nanotubes(MWCNTs)/Nafion(NA)/Hg electrode,by mean of diff erential pulse anodic strippi...An electrochemical flow device has been developed for the determination of heavy metal ions(HMI)in water using multiwalled carbon nanotubes(MWCNTs)/Nafion(NA)/Hg electrode,by mean of diff erential pulse anodic stripping voltammetry coupled with sequential injection analysis.The accuracy of the determination was ensured by the great electrical conductivity of MWCNTs and the high adsorption capacity of Hg.NA was used for MWCNTs immobilization for the long-term application of the electrode.The mercury film was cleaned after determination and another one would form during deposition.A lower limit of detection and a wider determination range of Cd^(2+)and Pb^(2+)could be achieved using the automatically analytical device combining with the MWCNTs/NA/Hg-modified electrode.The real-time monitoring of Cd^(2+)and Pb^(2+)in fresh water using this device continued for 10 days.The results indicated that the method was potential for on-site and real-time determination of HMI in water samples.展开更多
A novel differential pulse anodic stripping voltammetry for the determination of trace amounts of lead, using a biomacromolecule heparin drop-coated modified glassy carbon electrode, has been described. Pb2+ was depos...A novel differential pulse anodic stripping voltammetry for the determination of trace amounts of lead, using a biomacromolecule heparin drop-coated modified glassy carbon electrode, has been described. Pb2+ was deposited on the surface of a heparin-modified electrode at -1.0 V (vs. SCE) via forming Pb2+-heparin and subsequent re-duction at the electrode. In the following step, Pb-heparin was oxidized, and voltammograms were recorded by scanning the potential in a positive direction. Conditions were optimized with respect to the pH of the medium, the mass of drop-coated heparin, accumulation potential and accumulation time. The peak current was proportional to the Pb2+ concentration in the range of 2.0×10-9 to 7.0×10-7 mol/L. The detection limit was 3.0×10-10 mol/L. The relative standard deviation was 4.83% for 1.0×10-8 mol / L Pb2+ (n=10). The developed method has been applied to the determination of Pb2+ in water samples with satisfactory results.展开更多
A reliable method for simultaneous determination of three antibiotic drugs(levofloxacin,gatifloxacin and lomefloxacin) by differential pulse stripping voltammetry(DPSV) in Britton-Robinson buffer(pH 7.96) was pr...A reliable method for simultaneous determination of three antibiotic drugs(levofloxacin,gatifloxacin and lomefloxacin) by differential pulse stripping voltammetry(DPSV) in Britton-Robinson buffer(pH 7.96) was presented.The method is based on adsorptive accumulation of the antibacterial drugs on a hanging mercury dropping electrode(HMDE),followed by the reduction of the adsorptive species by the technique of DPSV.Optimal conditions,the deposition time of 80 s,the deposition potential of—1250 mV,and the scan rate of 25 mV/s,were obtained.The linear concentration ranges of 0.010-0.080μg/mL were obtained for all these three antibiotic drugs,while the detection limits were 2.38,3.20 and 1.60ng/mL for levofloxacin,gatifloxacin and lomefloxacin,respectively.In this work,chemometrics methods,such as classical least squares(CLS),partial least squares(PLS), principle component regression(PCR) and radial basis function-artificial neural networks(RBF-ANN),were used to quantitatively resolve the overlapping signals.It was found that PCR gave the best results with total relative prediction error(RPE_T) of 7.71%.The proposed method was applied to determine these three drugs in several commercial food samples with spiked method and yielded satisfactory recoveries.展开更多
In this work,we reported a simultaneous determination approach for Pb(II),Cd(II)and Zn(II)atμg L 1concentration levels using differential pulse stripping voltammetry on a bismuth film electrode(BiFE).The BiFE could b...In this work,we reported a simultaneous determination approach for Pb(II),Cd(II)and Zn(II)atμg L 1concentration levels using differential pulse stripping voltammetry on a bismuth film electrode(BiFE).The BiFE could be prepared in situ when the sample solution contained a suitable amount of Bi(NO)3,and its analytical performance was evaluated for the simultaneous determination of Pb(II),Cd(II)and Zn(II)in solutions.The determination limits were found to be 0.19μg L 1for Zn(II),and0.28μg L 1for Pb(II)and Cd(II),with a preconcentration time of 300 s.The BiFE approach was successfully applied to determine Pb(II),Cd(II)and Zn(II)in tea leaf and infusion samples,and the results were in agreement with those obtained using an atomic absorption spectrometry approach.Without Hg usage,the in situ preparation for BiFE supplied a green and acceptability sensitive method for the determination of the heavy metal ions.展开更多
Differential pulse stripping voltammetry method(DPSV) was applied to the determination of three herbicides, ametryn, cyanatryn, and dimethametryn. It was found that their voltammograms overlapped strongly, and it is...Differential pulse stripping voltammetry method(DPSV) was applied to the determination of three herbicides, ametryn, cyanatryn, and dimethametryn. It was found that their voltammograms overlapped strongly, and it is difficult to determine these compounds individually from their mixtures. With the aid of chemometrics, classical least squares(CLS), principal component regression(PCR) and partial least squares(PLS), voltammogram resolution and quantitative analysis of the synthetic mixtures of the three compounds were successfully performed. The proposed method was also applied to the analysis of some real samples with satisfactory results.展开更多
文摘Differential pulse cathodic stripping voltammetry was used to determine pesticide metsulfuron-methyl on a suspended mercury electrode.Specific experimental parameters,such as the pH of Britton-Robinson buffer,accumulation time,accumulation potential,and initial potential were optimized.The results show that a typical reduction peak appeared when pH was 2.0-4.0 and initial potential ranged from-0.75 to-1.0 V.To obtain the stripping signal of the best reduction peak,it is determined that the best pH was 2.0.The detection limit of the method was only 0.04 mg/L,and it had good selectivity and high accuracy,so the method has high sensitivity.In the analysis of actual drinking water,the recovery rate of metsulfuron-methyl could reach 93%-101%.
基金financially supported by the marine high-tech industry development projects of Fujian Province(No.2015-19)
文摘An electrochemical flow device has been developed for the determination of heavy metal ions(HMI)in water using multiwalled carbon nanotubes(MWCNTs)/Nafion(NA)/Hg electrode,by mean of diff erential pulse anodic stripping voltammetry coupled with sequential injection analysis.The accuracy of the determination was ensured by the great electrical conductivity of MWCNTs and the high adsorption capacity of Hg.NA was used for MWCNTs immobilization for the long-term application of the electrode.The mercury film was cleaned after determination and another one would form during deposition.A lower limit of detection and a wider determination range of Cd^(2+)and Pb^(2+)could be achieved using the automatically analytical device combining with the MWCNTs/NA/Hg-modified electrode.The real-time monitoring of Cd^(2+)and Pb^(2+)in fresh water using this device continued for 10 days.The results indicated that the method was potential for on-site and real-time determination of HMI in water samples.
基金Project supported by the National Natural Science Foundation of China (No. 20377007).
文摘A novel differential pulse anodic stripping voltammetry for the determination of trace amounts of lead, using a biomacromolecule heparin drop-coated modified glassy carbon electrode, has been described. Pb2+ was deposited on the surface of a heparin-modified electrode at -1.0 V (vs. SCE) via forming Pb2+-heparin and subsequent re-duction at the electrode. In the following step, Pb-heparin was oxidized, and voltammograms were recorded by scanning the potential in a positive direction. Conditions were optimized with respect to the pH of the medium, the mass of drop-coated heparin, accumulation potential and accumulation time. The peak current was proportional to the Pb2+ concentration in the range of 2.0×10-9 to 7.0×10-7 mol/L. The detection limit was 3.0×10-10 mol/L. The relative standard deviation was 4.83% for 1.0×10-8 mol / L Pb2+ (n=10). The developed method has been applied to the determination of Pb2+ in water samples with satisfactory results.
基金support by the National Natural Science Foundation of China (No21065007)the State Key Laboratory of Food Science and Technology of Nanchang University(SKLF-MB-201002 and SKLF-TS-200919)
文摘A reliable method for simultaneous determination of three antibiotic drugs(levofloxacin,gatifloxacin and lomefloxacin) by differential pulse stripping voltammetry(DPSV) in Britton-Robinson buffer(pH 7.96) was presented.The method is based on adsorptive accumulation of the antibacterial drugs on a hanging mercury dropping electrode(HMDE),followed by the reduction of the adsorptive species by the technique of DPSV.Optimal conditions,the deposition time of 80 s,the deposition potential of—1250 mV,and the scan rate of 25 mV/s,were obtained.The linear concentration ranges of 0.010-0.080μg/mL were obtained for all these three antibiotic drugs,while the detection limits were 2.38,3.20 and 1.60ng/mL for levofloxacin,gatifloxacin and lomefloxacin,respectively.In this work,chemometrics methods,such as classical least squares(CLS),partial least squares(PLS), principle component regression(PCR) and radial basis function-artificial neural networks(RBF-ANN),were used to quantitatively resolve the overlapping signals.It was found that PCR gave the best results with total relative prediction error(RPE_T) of 7.71%.The proposed method was applied to determine these three drugs in several commercial food samples with spiked method and yielded satisfactory recoveries.
基金supported by the National Natural Scientific Foundation of China(21175112)the Fund of Key Laboratory of Global Change and Marine-Atmospheric Chemistry,SOA,(GCMAC 1204)the Fujian Key Projects of Science and Technology(2011YZ0001-1)
文摘In this work,we reported a simultaneous determination approach for Pb(II),Cd(II)and Zn(II)atμg L 1concentration levels using differential pulse stripping voltammetry on a bismuth film electrode(BiFE).The BiFE could be prepared in situ when the sample solution contained a suitable amount of Bi(NO)3,and its analytical performance was evaluated for the simultaneous determination of Pb(II),Cd(II)and Zn(II)in solutions.The determination limits were found to be 0.19μg L 1for Zn(II),and0.28μg L 1for Pb(II)and Cd(II),with a preconcentration time of 300 s.The BiFE approach was successfully applied to determine Pb(II),Cd(II)and Zn(II)in tea leaf and infusion samples,and the results were in agreement with those obtained using an atomic absorption spectrometry approach.Without Hg usage,the in situ preparation for BiFE supplied a green and acceptability sensitive method for the determination of the heavy metal ions.
基金Supported by the National Natural Science Foundation of China(No. 20562009)the Natural Science Foundation of Jiangxi Province, China(No. 0620041)+1 种基金the State Key Laboratory of the Chemo/Biosensing and Chemometrics of Hunan University, Chi-na(No. 2005-22)the Program for Changjiang Scholars and Innovative Research Team in Universities of China(No. IRT0540).
文摘Differential pulse stripping voltammetry method(DPSV) was applied to the determination of three herbicides, ametryn, cyanatryn, and dimethametryn. It was found that their voltammograms overlapped strongly, and it is difficult to determine these compounds individually from their mixtures. With the aid of chemometrics, classical least squares(CLS), principal component regression(PCR) and partial least squares(PLS), voltammogram resolution and quantitative analysis of the synthetic mixtures of the three compounds were successfully performed. The proposed method was also applied to the analysis of some real samples with satisfactory results.