Fault locating for traveling-wave accelerators based on transmission line theory
1
作者 Tong-Ning Hu Hai-Meng Wang +4 位作者 Yi-Feng Zeng Hong-Jie Xu Li Chen Guang-Yao Feng Yuan-Ji Pei 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第8期24-34,共11页
Radio-frequency(RF)breakdown analysis and location are critical for successful development of high-gradient traveling-wave(TW)accelerators,especially those expected to generate high-intensity,high-power beams.Compared... Radio-frequency(RF)breakdown analysis and location are critical for successful development of high-gradient traveling-wave(TW)accelerators,especially those expected to generate high-intensity,high-power beams.Compared with commonly used schemes involving dedicated devices or complicated techniques,a convenient approach for breakdown locating based on transmission line(TL)theory offers advantages in the typical constant-gradient TW-accelerating structure.To deliver such an approach,an equivalent TL model has been constructed to equate the TW-accelerating structure based on the fun-damental theory of the TL transient response in the time domain.An equivalence relationship between the TW-accelerating structure and the TL model has been established via analytical derivations associated with grid charts and verified by TL circuit simulations.Furthermore,to validate the proposed fault-locating method in practical applications,an elaborate analysis via such a method has been conducted for the recoverable RF-breakdown phenomena observed at an existing prototype of a TW-accelerating-structure-based beam injector constructed at the Huazhong University of Science and Technology.In addition,further considerations and discussion for extending the applications of the proposed method have been given.This breakdown-locating approach involving the transient response in the framework of TL theory can be a conceivable supple-ment to existing methods,facilitating solution to construction problems at an affordable cost. 展开更多
关键词 Traveling-wave structure RF breakdown fault locating Transmission line
下载PDF
Optimal Configuration of Fault Location Measurement Points in DC Distribution Networks Based on Improved Particle Swarm Optimization Algorithm
2
作者 Huanan Yu Hangyu Li +1 位作者 He Wang Shiqiang Li 《Energy Engineering》 EI 2024年第6期1535-1555,共21页
The escalating deployment of distributed power sources and random loads in DC distribution networks hasamplified the potential consequences of faults if left uncontrolled. To expedite the process of achieving an optim... The escalating deployment of distributed power sources and random loads in DC distribution networks hasamplified the potential consequences of faults if left uncontrolled. To expedite the process of achieving an optimalconfiguration of measurement points, this paper presents an optimal configuration scheme for fault locationmeasurement points in DC distribution networks based on an improved particle swarm optimization algorithm.Initially, a measurement point distribution optimization model is formulated, leveraging compressive sensing.The model aims to achieve the minimum number of measurement points while attaining the best compressivesensing reconstruction effect. It incorporates constraints from the compressive sensing algorithm and networkwide viewability. Subsequently, the traditional particle swarm algorithm is enhanced by utilizing the Haltonsequence for population initialization, generating uniformly distributed individuals. This enhancement reducesindividual search blindness and overlap probability, thereby promoting population diversity. Furthermore, anadaptive t-distribution perturbation strategy is introduced during the particle update process to enhance the globalsearch capability and search speed. The established model for the optimal configuration of measurement points issolved, and the results demonstrate the efficacy and practicality of the proposed method. The optimal configurationreduces the number of measurement points, enhances localization accuracy, and improves the convergence speedof the algorithm. These findings validate the effectiveness and utility of the proposed approach. 展开更多
关键词 Optimal allocation improved particle swarm algorithm fault location compressed sensing DC distribution network
下载PDF
Multi-Branch Fault Line Location Method Based on Time Difference Matrix Fitting
3
作者 Hua Leng Silin He +3 位作者 Jian Qiu Feng Liu Xinfei Huang Jiran Zhu 《Energy Engineering》 EI 2024年第1期77-94,共18页
The distribution network exhibits complex structural characteristics,which makes fault localization a challenging task.Especially when a branch of the multi-branch distribution network fails,the traditional multi-bran... The distribution network exhibits complex structural characteristics,which makes fault localization a challenging task.Especially when a branch of the multi-branch distribution network fails,the traditional multi-branch fault location algorithm makes it difficult to meet the demands of high-precision fault localization in the multi-branch distribution network system.In this paper,the multi-branch mainline is decomposed into single branch lines,transforming the complex multi-branch fault location problem into a double-ended fault location problem.Based on the different transmission characteristics of the fault-traveling wave in fault lines and non-fault lines,the endpoint reference time difference matrix S and the fault time difference matrix G were established.The time variation rule of the fault-traveling wave arriving at each endpoint before and after a fault was comprehensively utilized.To realize the fault segment location,the least square method was introduced.It was used to find the first-order fitting relation that satisfies the matching relationship between the corresponding row vector and the first-order function in the two matrices,to realize the fault segment location.Then,the time difference matrix is used to determine the traveling wave velocity,which,combined with the double-ended traveling wave location,enables accurate fault location. 展开更多
关键词 Multi-branch lines distribution network fault location double-ended traveling wave positioning least square method
下载PDF
Research on Asymmetric Fault Location of Wind Farm Collection System Based on Compressed Sensing
4
作者 Huanan Yu Gang Han +1 位作者 Hansong Luo He Wang 《Energy Engineering》 EI 2023年第9期2029-2057,共29页
Aiming at the problem that most of the cables in the power collection systemof offshore wind farms are buried deep in the seabed,whichmakes it difficult to detect faults,this paper proposes a two-step fault location m... Aiming at the problem that most of the cables in the power collection systemof offshore wind farms are buried deep in the seabed,whichmakes it difficult to detect faults,this paper proposes a two-step fault location method based on compressed sensing and ranging equation.The first step is to determine the fault zone through compressed sensing,and improve the datameasurement,dictionary design and algorithmreconstruction:Firstly,the phase-locked loop trigonometric functionmethod is used to suppress the spike phenomenon when extracting the fault voltage,so that the extracted voltage valuewillnot have a large error due to the voltage fluctuation.Secondly,theλ-NIM dictionary is designed by using the node impedancematrix and the fault location coefficient to further reduce the influence of pseudo-fault points.Finally,the CoSaMP algorithmis improved with the generalized Jaccard coefficient to improve the reconstruction accuracy.The second step is to use the ranging equation to accurately locate the asymmetric fault of the wind farm collection system on the basis of determining the fault interval.The simulation results show that the proposedmethod ismore accurate than the compressedsensingmethod andimpedancemethod in fault section location and fault location accuracy,the relative error is reduced from 0.75%to 0.4%,and has a certain anti-noise ability. 展开更多
关键词 Offshore wind farm convergence system compression sensing ranging equation fault location
下载PDF
Study on Missile Intelligent Fault Diagnosis System Based on Fuzzy NN Expert System 被引量:7
5
作者 Yang Jun Feng Zhensheng +1 位作者 Zhang Xien & Liu Pengyuan Dept. of Missile Engineering, Ordnance Engineering College, Shijiazhuang 050003, P. R. China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2001年第1期82-87,共6页
In order to study intelligent fault diagnosis methods based on fuzzy neural network (NN) expert system and build up intelligent fault diagnosis for a type of missile weapon system, the concrete implementation of a fuz... In order to study intelligent fault diagnosis methods based on fuzzy neural network (NN) expert system and build up intelligent fault diagnosis for a type of missile weapon system, the concrete implementation of a fuzzy NN fault diagnosis expert system is given in this paper. Based on thorough research of knowledge presentation, the intelligent fault diagnosis system is implemented with artificial intelligence for a large-scale missile weapon equipment. The method is an effective way to perform fuzzy fault diagnosis. Moreover, it provides a new way of the fault diagnosis for large-scale missile weapon equipment. 展开更多
关键词 Artificial intelligence Electric fault location Expert systems Fuzzy sets Missiles Neural networks
下载PDF
Adaptive restarting method for LCC-HVDC based on principle of fault location by current injection 被引量:2
6
作者 Ruidong Xu Guobing Song +1 位作者 Junjie Hou Zhongxue Chang 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期554-563,共10页
The existing LCC-HVDC transmission project adopts the fixed-time delay restarting method.This method has disadvantages such as non-selectivity,long restart process,and high probability of restart failure.These issues ... The existing LCC-HVDC transmission project adopts the fixed-time delay restarting method.This method has disadvantages such as non-selectivity,long restart process,and high probability of restart failure.These issues cause a secondary impact on equipment and system power fluctuation.To solve this problem,an adaptive restarting method based on the principle of fault location by current injection is proposed.First,an additional control strategy is proposed to inject a current detection signal.Second,the propagation law of the current signal in the line is analyzed based on the distributed parameter model of transmission line.Finally,a method for identifying fault properties based on the principle of fault location is proposed.The method fully considers the influence of the long-distance transmission line with earth capacitance and overcomes the influence of the increasing effect of the opposite terminal.Simulation results show that the proposed method can accurately identify the fault properties under various complex fault conditions and subsequently realize the adaptive restarting process. 展开更多
关键词 LCC-HVDC Adaptive restarting Current signal injection fault location fault property identification
下载PDF
Accurate Fault Location Modeling for Parallel Transmission Lines Considering Mutual Effect 被引量:1
7
作者 Hamdy A.Ziedan Hegazy Rezk Mujahed Al-Dhaifallah 《Computers, Materials & Continua》 SCIE EI 2021年第4期491-518,共28页
:A new accurate algorithms based on mathematical modeling of two parallel transmissions lines system(TPTLS)as influenced by the mutual effect to determine the fault location is discussed in this work.The distance rela... :A new accurate algorithms based on mathematical modeling of two parallel transmissions lines system(TPTLS)as influenced by the mutual effect to determine the fault location is discussed in this work.The distance relay measures the impedance to the fault location which is the positive-sequence.The principle of summation the positive-,negative-,and zero-sequence voltages which equal zero is used to determine the fault location on the TPTLS.Also,the impedance of the transmission line to the fault location is determined.These algorithms are applied to single-line-to-ground(SLG)and double-line-to-ground(DLG)faults.To detect the fault location along the transmission line,its impedance as seen by the distance relay is determined to indicate if the fault is within the relay’s reach area.TPTLS under study are fed from one-and both-ends.A schematic diagrams are obtained for the impedance relays to determine the fault location with high accuracy. 展开更多
关键词 New accurate algorithms mathematical modeling fault location scheme diagrams parallel transmission lines mutual effect SLG and DLG faults
下载PDF
Fault Location Identification for Localized Intermittent Connection Problems on CAN Networks 被引量:1
8
作者 LEI Yong YUAN Yong SUN Yichao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第5期1038-1046,共9页
The intermittent connection(IC)of the field-bus in networked manufacturing systems is a common but hard troubleshooting network problem,which may result in system level failures or safety issues.However,there is no ... The intermittent connection(IC)of the field-bus in networked manufacturing systems is a common but hard troubleshooting network problem,which may result in system level failures or safety issues.However,there is no online IC location identification method available to detect and locate the position of the problem.To tackle this problem,a novel model based online fault location identification method for localized IC problem is proposed.First,the error event patterns are identified and classified according to different node sources in each error frame.Then generalized zero inflated Poisson process(GZIP)model for each node is established by using time stamped error event sequence.Finally,the location of the IC fault is determined by testing whether the parameters of the fitted stochastic model is statistically significant or not using the confident intervals of the estimated parameters.To illustrate the proposed method,case studies are conducted on a 3-node controller area network(CAN)test-bed,in which IC induced faults are imposed on a network drop cable using computer controlled on-off switches.The experimental results show the parameters of the GZIP model for the problematic node are statistically significant(larger than 0),and the patterns of the confident intervals of the estimated parameters are directly linked to the problematic node,which agrees with the experimental setup.The proposed online IC location identification method can successfully identify the location of the drop cable on which IC faults occurs on the CAN network. 展开更多
关键词 CAN network fault location identification GZIP model intermittent connection
下载PDF
Small-current grounding fault location method based on transient main resonance frequency analysis 被引量:2
9
作者 Yongjie Zhang Xiaojun Wang +2 位作者 Junjuan Li Yin Xu Guohong Wu 《Global Energy Interconnection》 2020年第4期324-334,共11页
The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we t... The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we take that the main resonant frequency and its corresponding component is related to the fault distance.Based on this,a fault location method based on double-end wavelet energy ratio at the scale corresponding to the main resonant frequency is proposed.And back propagation neural network(BPNN)is selected to fit the non-linear relationship between the wavelet energy ratio and fault distance.The performance of this proposed method has been verified in different scenarios of a simulation model in PSCAD/EMTDC. 展开更多
关键词 Small-current grounding fault location Main resonant frequency Double-end wavelet energy ratio Backpropagation neural network(BPNN)
下载PDF
Field experiment using transient energy method to locate a single-phase to ground fault 被引量:1
10
作者 Wei Xie Xuewen Wang +4 位作者 Chen Fang Hengxu Zhang Fang Shi Xiaodong Xing Baicong Sun 《Global Energy Interconnection》 CAS 2020年第6期585-594,共10页
Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults... Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults.Because of the weak fault current and imperfect monitoring equipment configurations,methods used to determine the faulty line secti ons with SPG faults in NIGSs are in effective.The developme nt and application of distributi on-level phasor measurement units(PMUs)provide further comprehensive fault information for fault diagnosis in a distribution network.When an SPG fault occurs,the transient energy of the faulted line section tends to be higher than the sum of the transient energies of other line sections.In this regard,transient energy-based fault location algorithms appear to be a promising resolution.In this study,a field test plan was designed and implemented for a 10 kV distribution network.The test results dem on strate the effective ness of the transient en ergy-based SPG locati on method in practical distributi on networks. 展开更多
关键词 Sin gle-phase-to-gro und fault fault location Neutral in efficiently groundi ng systems Distributi on n etwork Distribution-level PMU Transient energy.
下载PDF
Auxiliary Fault Location on Commercial Equipment Based on Supervised Machine Learning 被引量:1
11
作者 ZHAO Zipiao ZHAO Yongli +1 位作者 YAN Boyuan WANG Dajiang 《ZTE Communications》 2022年第S01期7-15,共9页
As the fundamental infrastructure of the Internet,the optical network carries a great amount of Internet traffic.There would be great financial losses if some faults happen.Therefore,fault location is very important f... As the fundamental infrastructure of the Internet,the optical network carries a great amount of Internet traffic.There would be great financial losses if some faults happen.Therefore,fault location is very important for the operation and maintenance in optical networks.Due to complex relationships among each network element in topology level,each board in network element level,and each component in board level,the con-crete fault location is hard for traditional method.In recent years,machine learning,es-pecially deep learning,has been applied to many complex problems,because machine learning can find potential non-linear mapping from some inputs to the output.In this paper,we introduce supervised machine learning to propose a complete process for fault location.Firstly,we use data preprocessing,data annotation,and data augmenta-tion in order to process original collected data to build a high-quality dataset.Then,two machine learning algorithms(convolutional neural networks and deep neural networks)are applied on the dataset.The evaluation on commercial optical networks shows that this process helps improve the quality of dataset,and two algorithms perform well on fault location. 展开更多
关键词 optical network fault location supervised machine learning
下载PDF
Fault Location Method for STATCOM Connected Transmission Lines Using CCM 被引量:1
12
作者 R. Ilango T. Sree Renga Raja 《Circuits and Systems》 2016年第10期3131-3141,共12页
Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to loca... Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%. 展开更多
关键词 Distance Relay fault Location Flexible AC Transmission Systems (FACTS) Power System Protection Static Synchronous Compensator (STATCOM)
下载PDF
One-End Data Method for Fault Position Estimate of Two-Parallel Transmission Lines
13
作者 张庆超 刘飞 +1 位作者 武永峰 宋文南 《Journal of Beijing Institute of Technology》 EI CAS 2003年第1期105-108,共4页
An accurate numerical algorithm for three-line fault involving different phases from each of two-parallel lines is presented. It is based on one-terminal voltage and current data. The loop and nodel equations comparin... An accurate numerical algorithm for three-line fault involving different phases from each of two-parallel lines is presented. It is based on one-terminal voltage and current data. The loop and nodel equations comparing faulted phase to non-faulted phase of two-parallel lines are introduced in the fault location estimation modal, in which the faulted impedance of remote end is not involved. The effect of load flow and fault resistance on the accuracy of fault location are effectively eliminated, therefore an accurate algorithm of locating fault is derived. The algorithm is demonstrated by digital computer simulations and the results show that errors in locating fault are less than 1%. 展开更多
关键词 power system two-parallel lines fault location estimation one-terminal data
下载PDF
Parameter identification algorithm for fault location using one terminal data based on frequency domain
14
作者 康小宁 索南加乐 《Journal of Pharmaceutical Analysis》 SCIE CAS 2007年第1期18-23,共6页
This paper presents a novel algorithm of fault location for transmission line.Solving the network spectrum equations for different frequencies the fault can be located accurately by this algorithm with one terminal da... This paper presents a novel algorithm of fault location for transmission line.Solving the network spectrum equations for different frequencies the fault can be located accurately by this algorithm with one terminal data of voltage and current,and the identified parameters,such as fault distance, fault resistance,and opposite terminal system resistance and inductance.The algorithm eliminates the influence of the opposite system impedance on the fault location accuracy,which causes the main error in traditional fault location methods using one terminal data.A method of calculating spectrum from sampled data is also proposed.EMTP simulations show the validity and higher accuracy of the fault location algorithm compared to the existing ones based on one terminal data. 展开更多
关键词 fault location parameter identification frequency domain analysis
下载PDF
Fault location method for transmission line based on traveling waves
15
作者 ZHENG Na ZHAO Yulin 《Journal of Northeast Agricultural University(English Edition)》 CAS 2007年第1期79-81,共3页
The single phase grounding fault location is the focus which researchers pay attention to and study in power system. The accurate fault location can lighten the patrolling burden, and enhance the reliability of the po... The single phase grounding fault location is the focus which researchers pay attention to and study in power system. The accurate fault location can lighten the patrolling burden, and enhance the reliability of the power network. It adopts A/D which has high speed, and uses TMS320VC5402 DSP chip as the system core. This paper presented theory of operation based on traveling waves and achieved software and hardware in detail. 展开更多
关键词 traveling waves fault location DSP
下载PDF
Fault location by one-terminal measurement in distribution network
16
作者 韩凤玲 王毅 董慧峰 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2001年第1期90-93,共4页
Presents the theory behind, the system design of the acquisition of parameters for and the experiment on the fault location by one terminal measurement in actual distribution network, and some of laws governing the on... Presents the theory behind, the system design of the acquisition of parameters for and the experiment on the fault location by one terminal measurement in actual distribution network, and some of laws governing the on site acquisition of parameters and fault location established through experimental research on actual power distribution lines. 展开更多
关键词 distribution network one terminal measurement fault location
下载PDF
T-Shaped Transmission Line Fault Location Based on Phase-Angle Jump Checking
17
作者 Jia’an Xie YurongWang +1 位作者 Guobin Jin Mucheng Wu 《Energy Engineering》 EI 2022年第5期1797-1809,共13页
In order to effectively solve the dead-zone and low-precision of T-shaped transmission line fault location,a new T-shaped transmission line fault location algorithm based on phase-angle jump checking is proposed in th... In order to effectively solve the dead-zone and low-precision of T-shaped transmission line fault location,a new T-shaped transmission line fault location algorithm based on phase-angle jump checking is proposed in this paper.Firstly,the 3-terminal synchronous fundamental positive sequence voltage and current phasors are extracted and substituted into the fault branch distance function to realize the selection of fault branch when the fault occurs;Secondly,use the condition of the fundamental positive sequence voltage phasor at the fault point is equal to calculate all roots(including real root and virtual roots);Finally,the phase-angle jump check function is used for checking calculation,and then the only real root can be determined as the actual fault distance,thereby achieving the purpose of high-precision fault location.MATLAB simulation results show that the proposed new algorithm is feasible and effective with high fault location accuracy and good versatility. 展开更多
关键词 T-shaped transmission line fault location real root and virtual roots phase-angle jump check function
下载PDF
Improved fault location method for AT traction power network based on EMU load test
18
作者 Guosong Lin Xuguo Fu +1 位作者 Wei Quan Bin Hong 《Railway Engineering Science》 2022年第4期532-540,共9页
The autotransformer(AT)neutral current ratio method is widely used for fault location in the AT traction power network.With the development of high-speed electrified railways,a large number of data show that the relat... The autotransformer(AT)neutral current ratio method is widely used for fault location in the AT traction power network.With the development of high-speed electrified railways,a large number of data show that the relation between the AT neutral current ratio and the distance from the beginning of the fault AT section to the fault point(Q-L relation)is mostly nonlinear.Therefore,the linear Q-L relation in the traditional fault location method always leads to large errors.To solve this problem,a large number of load-related current data that can be used to describe the Q-L relation are obtained through the load test of the electric multiple unit(EMU).Thus,an improved fault location method based on the back propagation(BP)neural network is proposed in this paper.On this basis,a comparison between the improved method and the traditional method shows that the maximum absolute error and the average absolute error of the improved method are 0.651 km and 0.334 km lower than those of the traditional method,respectively,which demonstrates that the improved method can effectively eliminate the influence of nonlinear factors and greatly improve the accuracy of fault location for the AT traction power network.Finally,combined with a shortcircuit test,the accuracy of the improved method is verified. 展开更多
关键词 fault location EMU load test BP neural network AT traction power network High-speed electrified railway
下载PDF
Improved Leap-frog Method for Time-domain Fault Location
19
作者 Izudin Džafić Rabih A.Jabr 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第2期670-674,共5页
The partial differential equation(PDE)solution of the telegrapher is a promising fault location method among time-domain and model-based techniques.Recent research works have shown that the leap-frog process is superi... The partial differential equation(PDE)solution of the telegrapher is a promising fault location method among time-domain and model-based techniques.Recent research works have shown that the leap-frog process is superior to other explicit methods for the PDE solution.However,its implementation is challenged by determining the initial conditions in time and the boundary conditions in space.This letter proposes two implicit solution methods for determining the initial conditions and an analytical way to obtain the boundary conditions founded on the signal decomposition.The results show that the proposal gives fault location accuracy superior to the existing leap-frog scheme,particularly in the presence of harmonics. 展开更多
关键词 fault location leap-frog partial differential equation time-domain analysis transmission line
原文传递
Location of Asymmetric Ground Fault Using Virtual Injected Current Ratio and Two-stage Recovery Strategy in Distribution Networks
20
作者 Haiting Shan Luliang Zhang +1 位作者 Q.H.Wu Mengshi Li 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第1期151-161,共11页
Sparse measurements challenge fault location in distribution networks.This paper proposes a method for asymmetric ground fault location in distribution networks with limited measurements.A virtual injected current vec... Sparse measurements challenge fault location in distribution networks.This paper proposes a method for asymmetric ground fault location in distribution networks with limited measurements.A virtual injected current vector is formulated to estimate the fault line,which can be reconstructed from voltage sags measured at a few buses using compressive sensing(CS).The relationship between the virtual injected current ratio(VICR)and fault position is deduced from circuit analysis to pinpoint the fault.Furthermore,a two-stage recovery strategy is proposed for improving reconstruction accuracy of the current vector,where two different sensing matrixes are utilized to improve the incoherence.The proposed method is validated in IEEE 34 node test feeder.Simulation results show asymmetric ground fault type,resistance,fault position and access of distributed generators(DGs)do not significantly influence performance of our method.In addition,it works effectively under various scenarios of noisy measurement and line parameter error.Validations on 134 node test feeders prove the proposed method is also suitable for systems with more complex structure. 展开更多
关键词 Distribution networks fault location reconstruction accuracy two-stage recovery virtual injected current ratio
原文传递
上一页 1 2 3 下一页 到第