We studied moist deciduous forests of Chhattisgarh, India (1) to assess the effect of four levels of historic wildland fire frequency (high, medium, low, and no-fire) on regeneration of seedlings in fire affected ...We studied moist deciduous forests of Chhattisgarh, India (1) to assess the effect of four levels of historic wildland fire frequency (high, medium, low, and no-fire) on regeneration of seedlings in fire affected areas during pre and post-fire seasons, (2) to evaluate vegetation struc- ture and diversity by layer in the four fire frequency zones, (3) to evalu- ate the impact of fire frequency on the structure of economically impor- tant tree species of the region, and (4) to quantify fuel loads by fire fre- quency level. We classified fire-affected areas into high, medium, low, and no-fire frequency classes based on government records. Tree species were unevenly distributed across fire frequency categories. Shrub density was maximum in zones of high fire frequency and minimum in low- frequency and no-fire zones. Lower tree density after fires indicated that regeneration of seedlings was reduced by fire. The population structure in the high-frequency zone was comprised of seedlings of size class (A) and saplings of size class (B), represented by Diospyros melanoxylon, Dalbergia sissoo, Shorea robusta and Tectona grandis. Younger and older trees were more abundant for Tectona grandis and Dalbargia sis- soo after fire, whereas intermediate-aged trees were more abundant pre- fire, indicating that the latter age-class was thinned by the catastrophic effect of fire. The major contributing components of fuel load included duff litter and small woody branches and twigs on the forest floor. Total fuel load on the forest floor ranged from 2.2 to 3.38 Mg/ha. The netchange in fuel load was positive in high- and medium-frequency fire zones and negative under low- and no-fire zones. Repeated fires, how- ever, slowly reduced stand stability. An ecological approach is needed for fire management to restore the no-fire spatial and temporal structure of moist deciduous forests, their species composition and fuel loads. The management approach should incorporate participatory forest manage- ment. Use of controlled fire, fire lines and mapping of fire prone areas are fundamental principles of fire hazard reduction in these areas.展开更多
Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in...Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in good agreement with those of tests. Fire resistance of the two kinds of composite slabs is calculated by using a numeric method. The results show that: due to heat absorbing of concrete, the performance of composite slabs under fire is better than that of unprotected steel structure, and fire resistance of composite slabs mentioned in this paper is at least 30 min subjected to standard fire. Parameters related to the fire resistance are discussed. It was found that with increasing of concrete strength and thickness of slab, fire resistance increases, and with increasing of steel strength and steel ratio, fire resistance decreases. Also thickness of fire proof is calculated by a numeric method. The results obtained in this paper may be referenced for practical engineering.展开更多
A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship betwe...A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship between pressure, temperature and concentration of the lithium bromide solution have been analyzed. The result obtained indicates that the pressure of the high pressure generator and the temperature of the exhausted smoke are the most sensitive parameters. It is also found that the transition time from a full load to a part load condition is quite long, and part load relative cooling capacity is almost near the intermittent running time ratio and oil consumption ratio.展开更多
Forest fire, an important agent for change in many forest ecosystems, plays an important role in atmo- spheric chemical cycles and the carbon cycle. The primary emissions from forest fire, CO2, CO, CH4, long-chained h...Forest fire, an important agent for change in many forest ecosystems, plays an important role in atmo- spheric chemical cycles and the carbon cycle. The primary emissions from forest fire, CO2, CO, CH4, long-chained hydrocarbons and volatile organic oxides, however, have not been well quantified. Quantifying the carbonaceous gas emissions of forest fires is a critical part to better under- stand the significance of forest fire in calculating carbon balance and forecasting climate change. This study uses images from Enhanced Thematic Mapper Plus (ETM+) on the Earth-observing satellite LANDSAT-7 for the year 2005 to estimate the total gases emitted by the 2006 Kanduhe forest fire in the Daxing'an Mountains. Our results suggest that the fire emitted approximately 149,187.66 t CO2, 21,187.70 t CO, 1925.41 t CxHy, 470.76 t NO and 658.77 t SO2. In addition, the gases emitted from larch forests were significantly higher than from both broadleaf-needle leaf mixed forests and broadleaf mixed forests.展开更多
基金financed by NRSA,Hyderabad,Forest Department of Chhattisgarh,India
文摘We studied moist deciduous forests of Chhattisgarh, India (1) to assess the effect of four levels of historic wildland fire frequency (high, medium, low, and no-fire) on regeneration of seedlings in fire affected areas during pre and post-fire seasons, (2) to evaluate vegetation struc- ture and diversity by layer in the four fire frequency zones, (3) to evalu- ate the impact of fire frequency on the structure of economically impor- tant tree species of the region, and (4) to quantify fuel loads by fire fre- quency level. We classified fire-affected areas into high, medium, low, and no-fire frequency classes based on government records. Tree species were unevenly distributed across fire frequency categories. Shrub density was maximum in zones of high fire frequency and minimum in low- frequency and no-fire zones. Lower tree density after fires indicated that regeneration of seedlings was reduced by fire. The population structure in the high-frequency zone was comprised of seedlings of size class (A) and saplings of size class (B), represented by Diospyros melanoxylon, Dalbergia sissoo, Shorea robusta and Tectona grandis. Younger and older trees were more abundant for Tectona grandis and Dalbargia sis- soo after fire, whereas intermediate-aged trees were more abundant pre- fire, indicating that the latter age-class was thinned by the catastrophic effect of fire. The major contributing components of fuel load included duff litter and small woody branches and twigs on the forest floor. Total fuel load on the forest floor ranged from 2.2 to 3.38 Mg/ha. The netchange in fuel load was positive in high- and medium-frequency fire zones and negative under low- and no-fire zones. Repeated fires, how- ever, slowly reduced stand stability. An ecological approach is needed for fire management to restore the no-fire spatial and temporal structure of moist deciduous forests, their species composition and fuel loads. The management approach should incorporate participatory forest manage- ment. Use of controlled fire, fire lines and mapping of fire prone areas are fundamental principles of fire hazard reduction in these areas.
文摘Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in good agreement with those of tests. Fire resistance of the two kinds of composite slabs is calculated by using a numeric method. The results show that: due to heat absorbing of concrete, the performance of composite slabs under fire is better than that of unprotected steel structure, and fire resistance of composite slabs mentioned in this paper is at least 30 min subjected to standard fire. Parameters related to the fire resistance are discussed. It was found that with increasing of concrete strength and thickness of slab, fire resistance increases, and with increasing of steel strength and steel ratio, fire resistance decreases. Also thickness of fire proof is calculated by a numeric method. The results obtained in this paper may be referenced for practical engineering.
文摘A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship between pressure, temperature and concentration of the lithium bromide solution have been analyzed. The result obtained indicates that the pressure of the high pressure generator and the temperature of the exhausted smoke are the most sensitive parameters. It is also found that the transition time from a full load to a part load condition is quite long, and part load relative cooling capacity is almost near the intermittent running time ratio and oil consumption ratio.
基金supported by Fundamental Research Funds for Central Universities(No.DL13BA02)National Natural Science Foundation of China(Grant No.31400552)+1 种基金the Twelfth5-Year National Science and Technology Project In Rural Areas(No.2011BAD37B0104)the Forestry Industry Research Special Funds For Public Welfare Project(No.201004003-6)
文摘Forest fire, an important agent for change in many forest ecosystems, plays an important role in atmo- spheric chemical cycles and the carbon cycle. The primary emissions from forest fire, CO2, CO, CH4, long-chained hydrocarbons and volatile organic oxides, however, have not been well quantified. Quantifying the carbonaceous gas emissions of forest fires is a critical part to better under- stand the significance of forest fire in calculating carbon balance and forecasting climate change. This study uses images from Enhanced Thematic Mapper Plus (ETM+) on the Earth-observing satellite LANDSAT-7 for the year 2005 to estimate the total gases emitted by the 2006 Kanduhe forest fire in the Daxing'an Mountains. Our results suggest that the fire emitted approximately 149,187.66 t CO2, 21,187.70 t CO, 1925.41 t CxHy, 470.76 t NO and 658.77 t SO2. In addition, the gases emitted from larch forests were significantly higher than from both broadleaf-needle leaf mixed forests and broadleaf mixed forests.