期刊文献+
共找到910篇文章
< 1 2 46 >
每页显示 20 50 100
Wildland fires and moist deciduous forests of Chhattisgarh, India: divergent component assessment 被引量:4
1
作者 B.H.Kittur S.L.Swamy +1 位作者 S.S.Bargali Manoj Kumar Jhariya 《Journal of Forestry Research》 SCIE CAS CSCD 2014年第4期857-866,共10页
We studied moist deciduous forests of Chhattisgarh, India (1) to assess the effect of four levels of historic wildland fire frequency (high, medium, low, and no-fire) on regeneration of seedlings in fire affected ... We studied moist deciduous forests of Chhattisgarh, India (1) to assess the effect of four levels of historic wildland fire frequency (high, medium, low, and no-fire) on regeneration of seedlings in fire affected areas during pre and post-fire seasons, (2) to evaluate vegetation struc- ture and diversity by layer in the four fire frequency zones, (3) to evalu- ate the impact of fire frequency on the structure of economically impor- tant tree species of the region, and (4) to quantify fuel loads by fire fre- quency level. We classified fire-affected areas into high, medium, low, and no-fire frequency classes based on government records. Tree species were unevenly distributed across fire frequency categories. Shrub density was maximum in zones of high fire frequency and minimum in low- frequency and no-fire zones. Lower tree density after fires indicated that regeneration of seedlings was reduced by fire. The population structure in the high-frequency zone was comprised of seedlings of size class (A) and saplings of size class (B), represented by Diospyros melanoxylon, Dalbergia sissoo, Shorea robusta and Tectona grandis. Younger and older trees were more abundant for Tectona grandis and Dalbargia sis- soo after fire, whereas intermediate-aged trees were more abundant pre- fire, indicating that the latter age-class was thinned by the catastrophic effect of fire. The major contributing components of fuel load included duff litter and small woody branches and twigs on the forest floor. Total fuel load on the forest floor ranged from 2.2 to 3.38 Mg/ha. The netchange in fuel load was positive in high- and medium-frequency fire zones and negative under low- and no-fire zones. Repeated fires, how- ever, slowly reduced stand stability. An ecological approach is needed for fire management to restore the no-fire spatial and temporal structure of moist deciduous forests, their species composition and fuel loads. The management approach should incorporate participatory forest manage- ment. Use of controlled fire, fire lines and mapping of fire prone areas are fundamental principles of fire hazard reduction in these areas. 展开更多
关键词 forest fire DIVERSITY fuel load vegetation structure
下载PDF
Behavior of steel-concrete composite slabs subjected to standard fire 被引量:2
2
作者 毛小勇 张耀春 韩林海 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2002年第2期155-160,共6页
Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in... Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in good agreement with those of tests. Fire resistance of the two kinds of composite slabs is calculated by using a numeric method. The results show that: due to heat absorbing of concrete, the performance of composite slabs under fire is better than that of unprotected steel structure, and fire resistance of composite slabs mentioned in this paper is at least 30 min subjected to standard fire. Parameters related to the fire resistance are discussed. It was found that with increasing of concrete strength and thickness of slab, fire resistance increases, and with increasing of steel strength and steel ratio, fire resistance decreases. Also thickness of fire proof is calculated by a numeric method. The results obtained in this paper may be referenced for practical engineering. 展开更多
关键词 Composite SLAB temperature FIELDS VALID load under fire failure CRITERIA fire resistance fire PROOF finite element numeric method
下载PDF
Dynamic Performance of On-off Operation for a Small Scale Direct Fired Absorption Chiller
3
作者 Wang Lei(王磊) +1 位作者 Lu Zhen(陆震) 《Journal of Donghua University(English Edition)》 EI CAS 2001年第1期46-50,共5页
A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship betwe... A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship between pressure, temperature and concentration of the lithium bromide solution have been analyzed. The result obtained indicates that the pressure of the high pressure generator and the temperature of the exhausted smoke are the most sensitive parameters. It is also found that the transition time from a full load to a part load condition is quite long, and part load relative cooling capacity is almost near the intermittent running time ratio and oil consumption ratio. 展开更多
关键词 DIRECT fired ABSORPTION chiller part load DYNAMIC performance.
下载PDF
宽负荷下切圆燃煤锅炉H_(2)S分布特性的数值模拟 被引量:1
4
作者 邓磊 袁茂博 +3 位作者 杨家辉 韩磊 姜家豪 车得福 《煤炭学报》 EI CAS CSCD 北大核心 2024年第6期2887-2895,共9页
锅炉采用空气分级燃烧降低NO_(x)排放的同时也提高了主燃区H_(2)S体积分数。炉墙壁面过高的H_(2)S体积分数是加剧水冷壁高温腐蚀的重要因素。为保障新能源并网发电,大型燃煤机组灵活调峰的需求增加,不同负荷下的水冷壁近壁面H_(2)S分布... 锅炉采用空气分级燃烧降低NO_(x)排放的同时也提高了主燃区H_(2)S体积分数。炉墙壁面过高的H_(2)S体积分数是加剧水冷壁高温腐蚀的重要因素。为保障新能源并网发电,大型燃煤机组灵活调峰的需求增加,不同负荷下的水冷壁近壁面H_(2)S分布特性值得关注。通过正交试验分析了切圆燃煤锅炉运行参数对水冷壁近壁面H_(2)S体积分数分布的影响。选取一台超临界600 MW切圆燃煤锅炉建立数值模型,设计L_(16)(4^(5))正交工况,覆盖100%BMCR、75%THA,50%THA以及35%BMCR四种负荷。建立了自定义SO_(x)生成模型以确定燃料硫的析出和转化路径,模型包含多表面反应子模型以描述焦炭与O_(2)/CO_(2)/H_(2)O等3种气体的异相反应,并确定焦炭气化反应消耗量占总消耗量的比例,进而对炉膛H_(2)S空间分布进行了模拟计算。研究表明,近壁面高体积分数H_(2)S区域主要位于投运燃烧器层中最下层燃烧器以下以及最上层燃烧器以上至SOFA层之间,烟气切圆沿炉膛高度增加逐渐增大是造成后一区域H_(2)S体积分数较高的重要原因。35%BMCR负荷下水冷壁重点区域的H_(2)S平均体积分数为364μL/L,明显低于其他负荷。锅炉运行参数对重点区域H_(2)S体积分数影响程度的排序为:锅炉负荷>一次风率>主燃区空气过量系数>假想切圆直径>燃烧器竖直摆角。 展开更多
关键词 切圆燃煤锅炉 宽负荷 H2S分布 正交分析 数值模拟
下载PDF
超高层建筑综合体消防负荷供配电系统设计 被引量:1
5
作者 迟珊 《建筑电气》 2024年第1期3-7,共5页
结合现行国家、行业及地方规范、标准,对超高层建筑综合体的消防负荷供配电系统、柴油发电机选择等设计方法及设计要点进行详细探讨。
关键词 超高层建筑 综合体 消防负荷 供配电系统 设计要点 柴油发电机组 配电干线 防火分区
下载PDF
燃煤机组锅炉负荷偏差分析模型与评价系统
6
作者 陈冬林 蒋权 +4 位作者 胡章茂 殷立国 杨宁武 刘文哲 张博 《锅炉技术》 北大核心 2024年第3期19-27,共9页
“双碳”大背景下我国上网新能源装机发展十分迅速。为了加大电网对新能源发电的消纳,燃煤发电机组频繁参与深度调峰导致了机组实际负荷与自动发电控制(AGC)指令负荷出现较大偏差。针对这一技术难题,以锅炉及其辅助设备为对象,研究构建... “双碳”大背景下我国上网新能源装机发展十分迅速。为了加大电网对新能源发电的消纳,燃煤发电机组频繁参与深度调峰导致了机组实际负荷与自动发电控制(AGC)指令负荷出现较大偏差。针对这一技术难题,以锅炉及其辅助设备为对象,研究构建了锅炉机组本体及其辅助设备的实际出力模型、应有出力模型和最大出力模型,建立了用以分析评价锅炉机组负荷偏差原因及诊断与预警的分析评价系统,并将该系统在电厂中进行了验证。结果表明:该分析评价系统可有效地对锅炉及其辅助设备的出力故障进行早期预警和诊断,可有效提高机组运行的可靠性、安全性与经济性。 展开更多
关键词 燃煤机组 锅炉 负荷偏差 系统开发
下载PDF
Estimation of gases emitted by forest fires based on remote sensing data
7
作者 Qiang Wang Futao Guo +2 位作者 Haiqing Hu Sen Jin Zhangwen Su 《Journal of Forestry Research》 SCIE CAS CSCD 2016年第2期369-378,共10页
Forest fire, an important agent for change in many forest ecosystems, plays an important role in atmo- spheric chemical cycles and the carbon cycle. The primary emissions from forest fire, CO2, CO, CH4, long-chained h... Forest fire, an important agent for change in many forest ecosystems, plays an important role in atmo- spheric chemical cycles and the carbon cycle. The primary emissions from forest fire, CO2, CO, CH4, long-chained hydrocarbons and volatile organic oxides, however, have not been well quantified. Quantifying the carbonaceous gas emissions of forest fires is a critical part to better under- stand the significance of forest fire in calculating carbon balance and forecasting climate change. This study uses images from Enhanced Thematic Mapper Plus (ETM+) on the Earth-observing satellite LANDSAT-7 for the year 2005 to estimate the total gases emitted by the 2006 Kanduhe forest fire in the Daxing'an Mountains. Our results suggest that the fire emitted approximately 149,187.66 t CO2, 21,187.70 t CO, 1925.41 t CxHy, 470.76 t NO and 658.77 t SO2. In addition, the gases emitted from larch forests were significantly higher than from both broadleaf-needle leaf mixed forests and broadleaf mixed forests. 展开更多
关键词 Forest fire Gases estimation Daxing'anMountains China Fuel load estimation Fuel loadconsumption Greenhouse gases CARBON
下载PDF
适应大型燃煤机组全工况灵活性运行的快速变负荷控制策略
8
作者 侯国莲 黄婷 +5 位作者 郭志强 余琦 江浩 李勇 周振华 安振一 《热力发电》 CAS CSCD 北大核心 2024年第12期93-101,共9页
随着高比例可再生能源电网负荷波动问题的日益突出,提高大型燃煤机组在全工况下的快速变负荷能力已成为维护电力系统安全稳定运行的迫切需求。为此,提出了一种与高加旁路改造技术相结合的负荷快速调控策略以实现灵活性需求下的超临界机... 随着高比例可再生能源电网负荷波动问题的日益突出,提高大型燃煤机组在全工况下的快速变负荷能力已成为维护电力系统安全稳定运行的迫切需求。为此,提出了一种与高加旁路改造技术相结合的负荷快速调控策略以实现灵活性需求下的超临界机组全工况负荷快速爬坡。首先,为机组的高压回热系统增加一条高加小旁路灵活改变从汽轮机抽取的高温高压蒸汽量,以加快直流锅炉的能量供给速率;其次,充分考虑滑压运行模式下机炉可承受的主蒸汽压力、温度的上下限及变化速率,同时对输出功率与主蒸汽压力进行解耦并设计一套适应机组高爬坡速率的负荷快速调控方案;最后,在某燃煤600 MW机组上进行试验验证。研究结果表明,负荷爬坡速率3%Pe/min下机组能够实现全工况范围内的负荷快速响应,且主蒸汽压力、汽轮机总调节阀开度等参数保持平稳变化,并通过仿真验证了机组在负荷爬坡速率5%Pe/min下的负荷调节能力,充分证实了所设计负荷快速调控策略的有效性。 展开更多
关键词 燃煤机组 负荷快速爬坡 全工况 灵活运行 改进协调控制策略
下载PDF
火灾后正六边形孔蜂窝组合梁受力性能研究
9
作者 吕俊利 齐雪婷 +2 位作者 高青松 李汝凯 祝健 《山东建筑大学学报》 2024年第1期9-15,共7页
火灾后蜂窝组合梁受力性能研究可为建筑结构受火后的加固修复提供重要依据。文章通过两个火灾后正六边形孔蜂窝组合梁的静力加载试验,分析了不同开孔率的正六边形孔蜂窝组合梁的破坏形态和承载性能。结果表明:火灾后正六边形孔蜂窝组合... 火灾后蜂窝组合梁受力性能研究可为建筑结构受火后的加固修复提供重要依据。文章通过两个火灾后正六边形孔蜂窝组合梁的静力加载试验,分析了不同开孔率的正六边形孔蜂窝组合梁的破坏形态和承载性能。结果表明:火灾后正六边形孔蜂窝组合梁在正弯矩作用下会发生弯曲破坏,临近梁端的第3个孔压缩变形较为严重且两侧钢梁腹板局部屈曲,两加载点之间板顶混凝土破坏严重,钢梁上部板面出现纵向贯通裂缝;开孔率是影响火灾后正六边形孔蜂窝组合梁极限承载力的重要因素,相较于开孔率为70%的蜂窝组合梁,开孔率为60%的蜂窝组合梁的极限承载力和延性分别提高了20%和35%;所提出的正六边形孔蜂窝组合梁受火后剩余承载力计算方法具有较好的精度。 展开更多
关键词 蜂窝组合梁 火灾后 静力加载试验 开孔率 受力性能
下载PDF
330 MW机组煤粉锅炉耦合油污泥低负荷燃烧数值模拟与试验研究 被引量:2
10
作者 张海丹 张凡志 +2 位作者 方仙明 梁震 张光学 《热力发电》 CAS CSCD 北大核心 2024年第3期153-160,共8页
针对含油污泥的无害化处置问题,提出预处理后送入煤粉锅炉与煤粉耦合燃烧的技术路线,在330 MW机组四角切圆锅炉上做了改造,并进行了含油污泥的热重分析及含油污泥入炉后的数值模拟,开展了油污泥入炉低负荷稳燃试验。结果表明:含油污泥... 针对含油污泥的无害化处置问题,提出预处理后送入煤粉锅炉与煤粉耦合燃烧的技术路线,在330 MW机组四角切圆锅炉上做了改造,并进行了含油污泥的热重分析及含油污泥入炉后的数值模拟,开展了油污泥入炉低负荷稳燃试验。结果表明:含油污泥具有易着火且热值接近动力煤的特点,可提高锅炉低负荷稳燃能力;含油污泥入炉后火焰中心略微下移,排放的烟气NO_(x)量有所降低;锅炉最低稳燃负荷率可低至20.00%,对应燃烧器层炉膛温度上升30~50℃,煤粉燃烧器火检信号更稳定,飞灰含碳量从4.79%降至3.80%,证明了油污泥对低负荷工况下煤粉燃烧的促进作用;120 MW负荷下含油污泥入炉后,锅炉效率提高约0.23百分点,可降低供电煤耗率约0.7 g/(k W·h),含油污泥热值可替代标准煤约3.7 t/h,节能效果显著。 展开更多
关键词 含油污泥 锅炉 耦合燃烧 低负荷稳燃
下载PDF
火灾后圆形孔蜂窝组合梁受力性能研究
11
作者 吕俊利 高青松 +1 位作者 齐雪婷 孙柏 《山东建筑大学学报》 2024年第5期11-19,共9页
圆形孔蜂窝组合梁火灾后的力学性能研究,可为受火后建筑结构性能评估提供参考依据。对4根火灾后圆形孔蜂窝组合梁及1根未过火处理圆形孔蜂窝组合梁开展静力加载试验,分析火灾、加劲肋设置、开孔率等因素对圆形孔蜂窝组合梁破坏形态、抗... 圆形孔蜂窝组合梁火灾后的力学性能研究,可为受火后建筑结构性能评估提供参考依据。对4根火灾后圆形孔蜂窝组合梁及1根未过火处理圆形孔蜂窝组合梁开展静力加载试验,分析火灾、加劲肋设置、开孔率等因素对圆形孔蜂窝组合梁破坏形态、抗弯刚度及承载能力的影响。结果表明:降低开孔率可以提高火灾后圆形孔蜂窝组合梁的抗弯刚度和极限承载能力;设置加劲肋的火灾后圆形孔蜂窝组合梁与未设置加劲肋的构件相比,其极限承载能力提高了6.9%;火灾前、后,圆形孔蜂窝组合梁在静力荷载作用下均发生弯曲破坏,但火灾后其开裂荷载、极限承载能力和延性均出现不同幅度的下降;提出了具有良好精度的圆形孔蜂窝组合梁火灾后剩余抗弯承载力的计算方法。 展开更多
关键词 圆形孔蜂窝组合梁 火灾后 静力试验 承载力 破坏形态
下载PDF
火灾后装配式钢筋混凝土梁疲劳性能试验研究
12
作者 傅传国 匡华硕 +2 位作者 王运兴 秦海亮 许腾飞 《山东建筑大学学报》 2024年第5期1-10,共10页
开展火灾后装配式钢筋混凝土结构承载性能研究,对于其抗灾能力提升具有重要的理论和现实意义。为模拟装配式钢筋混凝土梁装配连接节点性能,设计了4根两端为预制部分、钢筋采用灌浆套筒连接的对接连接足尺装配式钢筋混凝土简支梁试件,对... 开展火灾后装配式钢筋混凝土结构承载性能研究,对于其抗灾能力提升具有重要的理论和现实意义。为模拟装配式钢筋混凝土梁装配连接节点性能,设计了4根两端为预制部分、钢筋采用灌浆套筒连接的对接连接足尺装配式钢筋混凝土简支梁试件,对1根试件进行火灾作用后的静力加载试验,对另外3根试件进行火灾作用后循环加载下的耐疲劳性能试验。结果表明:经历火灾作用后的试验梁,静载破坏呈现延性破坏特征,而疲劳破坏则呈现明显的脆性破坏特征;循环荷载下限值相同时,随着循环荷载上限值的增加,试验梁实测疲劳寿命明显降低,循环荷载幅值为150和120 kN时的实测疲劳寿命比幅值为90 kN时分别降低55.07%和34.78%,说明循环荷载幅值对火灾后装配式钢筋混凝土梁的耐疲劳性能影响显著。 展开更多
关键词 装配式 火灾后 钢筋混凝土梁 循环加载 疲劳性能
下载PDF
600 MW机组燃煤锅炉30%深度调峰下现场试验研究 被引量:1
13
作者 闫超 李德波 +6 位作者 廖伟辉 陈兆立 阙正斌 陈智豪 阚伟民 余冯坚 陈锦攀 《广东电力》 北大核心 2024年第3期109-114,共6页
随着新能源发电机组装机容量不断增加,需要提高电网的新能源消纳能力,因此对火电机组的调峰要求越来越高。为了研究燃煤机组深度调峰的能力及影响,基于广东省内某600 MW机组燃煤锅炉,开展低负荷稳燃现场试验研究。试验结果表明:该锅炉... 随着新能源发电机组装机容量不断增加,需要提高电网的新能源消纳能力,因此对火电机组的调峰要求越来越高。为了研究燃煤机组深度调峰的能力及影响,基于广东省内某600 MW机组燃煤锅炉,开展低负荷稳燃现场试验研究。试验结果表明:该锅炉可以在30%额定负荷(180 MW)条件下稳定运行,且整个过程中现有的各系统经过调控后基本能正常工作;在降负荷过程和低负荷稳定运行过程中,机组环保参数无超标,各污染物排放指标符合环保要求。研究结果可作为机组深度调峰依据,为燃煤锅炉低负荷运行控制提供参考。 展开更多
关键词 调峰 燃煤锅炉 低负荷 系统运行 热效率 污染物
下载PDF
火灾后高强钢管混凝土柱轴压的参数化分析
14
作者 王晓初 杨玉琪 +5 位作者 刘晓 回彦川 崔洧瑄 袁立灏 朱俊 侯东序 《沈阳大学学报(自然科学版)》 CAS 2024年第1期61-67,76,共8页
为研究不同参数对火灾后高强钢管混凝土柱受轴压时的性能影响,利用ABAQUS有限元软件模拟火灾后高强钢管混凝土柱轴压模型,对该构件以钢管屈服强度、受火时间、混凝土强度为主要参数进行承载力-位移曲线分析,并剖析火灾后高强钢管混凝土... 为研究不同参数对火灾后高强钢管混凝土柱受轴压时的性能影响,利用ABAQUS有限元软件模拟火灾后高强钢管混凝土柱轴压模型,对该构件以钢管屈服强度、受火时间、混凝土强度为主要参数进行承载力-位移曲线分析,并剖析火灾后高强钢管混凝土柱典型曲线。结果表明:随着钢管屈服强度和混凝土强度增大,构件极限承载力增大;随着受火时间增加构件极限承载力出现下降趋势;从整体上看,受火时间分别为60、90、120 min时,构件中的混凝土承担主要载荷。 展开更多
关键词 高强钢管混凝土 火灾后 参数化分析 轴压 极限承载力
下载PDF
木结构建筑之间火灾蔓延的试验研究
15
作者 彭磊 邱培芳 欧加加 《消防科学与技术》 CAS 北大核心 2024年第7期959-966,共8页
搭建木结构试验框架,对影响木结构建筑之间火灾蔓延的因素开展实体火灾试验研究,分别考虑火灾荷载密度、外墙开口尺寸、外墙材料的燃烧性能、水平间距等影响因素。研究结果表明,在相同火灾荷载密度条件下,增大着火房间外墙开口面积会显... 搭建木结构试验框架,对影响木结构建筑之间火灾蔓延的因素开展实体火灾试验研究,分别考虑火灾荷载密度、外墙开口尺寸、外墙材料的燃烧性能、水平间距等影响因素。研究结果表明,在相同火灾荷载密度条件下,增大着火房间外墙开口面积会显著增大目标墙体上的辐射强度;在相同的开口条件下,增加室内火灾荷载密度,也会增大目标墙体上的辐射强度;当着火房间的外墙被引燃时,目标墙体受窗口辐射和被引燃外墙上火焰的双重辐射,会进一步增加火灾蔓延的风险。在测试的火灾场景中,当防火间距为6 m时,目标墙体上的辐射热流强度值小于10 kW/m^(2),不会因热辐射的原因造成建筑之间的火灾蔓延。研究结果可为定量分析各因素对火灾在建筑之间蔓延的影响和合理确定防火间距提供数据支撑。 展开更多
关键词 木结构建筑 火灾蔓延 辐射强度 防火间距 开口尺寸 火灾荷载密度
下载PDF
火灾后钢筋混凝土板力学性能评估方法
16
作者 李玉梅 王广勇 戴林 《防灾减灾工程学报》 CSCD 北大核心 2024年第2期389-395,共7页
钢筋混凝土楼板是火灾中最容易破坏的结构构件,需要对其火灾后的承载能力进行评估并加固。考虑升温阶段、降温阶段及火灾后阶段材料本构关系的不同,考虑高温下混凝土保护层的爆裂对温度场及力学性能的影响,提出了火灾后钢筋混凝土楼板... 钢筋混凝土楼板是火灾中最容易破坏的结构构件,需要对其火灾后的承载能力进行评估并加固。考虑升温阶段、降温阶段及火灾后阶段材料本构关系的不同,考虑高温下混凝土保护层的爆裂对温度场及力学性能的影响,提出了火灾后钢筋混凝土楼板力学性能分析的有限元计算模型。同时,针对典型的钢筋混凝土板加固方法,在前述有限元模型的基础上建立了火灾后加固的钢筋混凝土板有限元计算模型,利用该模型对典型的火灾后加固钢筋混凝土板的承载能力进行了计算分析。模型中采用单元生死技术实现了混凝土高温下的爆裂及火灾后加固的数值模拟,模型可用于火灾后及加固后钢筋混凝土板力学性能的评估。分析表明,经历火灾后,钢筋混凝土板的承载能力降低幅度较大,板存在明显残余挠度。加固后,钢筋混凝土板的承载能力得到较大程度的恢复。 展开更多
关键词 火灾后 钢筋混凝土楼板 承载能力 升温阶段 降温阶段 加固
下载PDF
超重型消防车地下室顶板荷载等效取值研究
17
作者 陈悦 刘光七 +1 位作者 沈培文 李畅 《四川建筑科学研究》 2024年第5期28-34,共7页
目前国内各大城市均有采购多辆101 m登高平台消防车(63 t),其重量远远超过了《建筑结构荷载规范》(GB 50009—2012)中原型消防车的重量(30 t),《建筑结构荷载规范》(GB 50009—2012)未对此类消防车给出具体的等效均布荷载取值。以101 m... 目前国内各大城市均有采购多辆101 m登高平台消防车(63 t),其重量远远超过了《建筑结构荷载规范》(GB 50009—2012)中原型消防车的重量(30 t),《建筑结构荷载规范》(GB 50009—2012)未对此类消防车给出具体的等效均布荷载取值。以101 m登高平台消防车(63 t)为研究对象,首先通过绘制板的跨中弯矩影响面来确定其最不利位置,然后利用ABAQUS计算出2种荷载工况下板的跨中弯矩值,最后再等效出101 m登高平台消防车(63 t)分别在7 m×7 m、8 m×8 m、9 m×9 m双向板的荷载取值。结果表明:板跨大于6 m的地下室双向板消防车荷载不建议直接取规范值,可按照设计需要采用相应流程进行等效;若对地下室顶板设计精度要求不高,当双向板板跨大于8 m时,63 t级消防车可参照规范要求进行荷载等效。 展开更多
关键词 超重型消防车 地下室顶板 影响面 荷载等效
下载PDF
利用热网蓄能辅助供热机组调频的控制研究
18
作者 殳建军 史耕金 《计算机仿真》 2024年第5期102-106,115,共6页
随着如风电、太阳能等可再生能源的并网,使得火电机组需要进行深度调峰且快速响应调度指令。然而,传统的负荷调节控制方法难以使得机组应对调度指令的频繁变化。火电机组热网包含着大量的管道与热力设备,它们均具有很强的蓄热能力,合理... 随着如风电、太阳能等可再生能源的并网,使得火电机组需要进行深度调峰且快速响应调度指令。然而,传统的负荷调节控制方法难以使得机组应对调度指令的频繁变化。火电机组热网包含着大量的管道与热力设备,它们均具有很强的蓄热能力,合理利用其蓄热可在短时间内提升机组负荷响应速度。针对上述问题,对利用热网蓄能辅助供热机组负荷调节进行了研究,并设计了基于调度指令与负荷响应偏差的协调控制系统。仿真结果表明,所设计的协调控制系统能够提高机组负荷响应调度指令的能力,且保证供热压力的稳定。 展开更多
关键词 火电机组 蓄能 热网 协调控制系统 负荷调节
下载PDF
600 MW等级超超临界燃煤发电机组动态建模与变负荷控制优化
19
作者 刘茜 刘泽锋 +2 位作者 王朝阳 刘明 严俊杰 《热力发电》 CAS CSCD 北大核心 2024年第10期97-105,共9页
为提升超超临界燃煤发电机组变负荷过程关键参数控制效果及能效,以某600 MW等级超超临界燃煤发电机组为研究对象进行建模仿真,其关键热力参数偏差满足火电仿真标准规定,建立了燃煤发电机组热力系统内部蓄热分布模型,提出了前馈机组内部... 为提升超超临界燃煤发电机组变负荷过程关键参数控制效果及能效,以某600 MW等级超超临界燃煤发电机组为研究对象进行建模仿真,其关键热力参数偏差满足火电仿真标准规定,建立了燃煤发电机组热力系统内部蓄热分布模型,提出了前馈机组内部蓄热状态的水燃比和烟气挡板开度控制逻辑,将机组变负荷过程实时的蓄热状态前馈到给水、给煤流量和烟气挡板调控中。仿真结果表明:机组在40%THA~70%THA负荷段以1.0%Pe/min~3.0%Pe/min速率变负荷时,累计主蒸汽温度偏差率绝对值下降27%~31%,机组瞬态过程平均发电标准煤耗率下降0.37~0.65 g/(kW·h)。证明所提出的控制策略提升了超超临界燃煤发电机组变负荷瞬态过程关键热力参数控制精度和能量转化效率。 展开更多
关键词 燃煤发电 变负荷 汽温控制 瞬态节能
下载PDF
备用电源与应急电源对比及供电方案探讨 被引量:1
20
作者 陈车 《建筑电气》 2024年第3期9-13,3,共6页
对比多本国家标准及规范对备用电源和应急电源术语的定义;分析二者的区别和侧重点;提出供配电系统设计时应充分理解备用电源和应急电源的定义,根据工程的负荷性质、用电容量、工程特点、系统规模和发展规划及当地供电条件进行多方案比选... 对比多本国家标准及规范对备用电源和应急电源术语的定义;分析二者的区别和侧重点;提出供配电系统设计时应充分理解备用电源和应急电源的定义,根据工程的负荷性质、用电容量、工程特点、系统规模和发展规划及当地供电条件进行多方案比选,并对5种备用电源供电方案和3种应急电源供电方案的特点和适用范围进行探讨。 展开更多
关键词 备用电源 应急电源 供电方案 消防负荷 应急母线段 备用母线段 消防母线段 柴油发电机组 特级负荷
下载PDF
上一页 1 2 46 下一页 到第
使用帮助 返回顶部