Fifty-six patients with chest pain underwent selective coronaryangiography,radionuclide ventriculography (RNV) and frequency domaincardiography (FCG) to evaluate left ventricular function in coronary artery dis-ease (...Fifty-six patients with chest pain underwent selective coronaryangiography,radionuclide ventriculography (RNV) and frequency domaincardiography (FCG) to evaluate left ventricular function in coronary artery dis-ease (CAD).The sensitivity,specificity and accuracy of FCG were 87.5%,77.8%and 82.9%,respectively,which were slightly less than those of RNV (92.5%,88.9% and 90.8%,respectively).The changes of FCG scores were negatively corre-lated with changes of LVEF (r=-0.586,P【0.01),and TS (r=-0.679,P【0.01).These results indicate that FCG may be useful for the evaluation of leftventricular function in patients with CAD.展开更多
目的探讨左束支区域起搏与右心室间隔起搏技术对老年患者左心室收缩同步性、心功能的影响。方法回顾性选取2022年2月至2023年3月期间于郴州市第一人民医院心血管内科接受永久性心脏起搏器植入术治疗的80例老年患者的临床资料,根据心脏...目的探讨左束支区域起搏与右心室间隔起搏技术对老年患者左心室收缩同步性、心功能的影响。方法回顾性选取2022年2月至2023年3月期间于郴州市第一人民医院心血管内科接受永久性心脏起搏器植入术治疗的80例老年患者的临床资料,根据心脏起搏电极植入部位分为两组,即对照组、观察组各40例。对照组患者于右心室间隔处植入心脏起搏器,观察组患者于左束支区域植入心脏起搏器。分别于患者心脏起搏器植入术后1个月、术后6个月、术后12个月观察各指标变化,包括左心室收缩同步性参数[左心室收缩期纵向应变达峰时间标准差(time to peak longitudinal strain standard deviation,Tls-SD)、最大差值(time to peak longitudinal strain maximum difference,Tls-dif),左心室收缩期径向应变达峰时间标准差(time to peak radial strain standard deviation,Trs-SD)、最大差值(time to peak radial strain maximum difference,Trs-dif),左心室收缩期环向应变达峰时间标准差(time to peak circumferential strain standard deviation,Tcs-SD)、最大差值(time to peak circumferential strain maximum difference,Tcs-dif)]以及心功能指标[左心室射血分数(left ventricular ejection fraction,LVEF)、心排血量(cardiac output,CO)、心脏指数(cardiac index,CI)]、心腔大小[右心房内径(right atrial inner diameter,RAD)、左心房内径(left atrial diameter,LAD)、左心室舒张末期内径(left ventricular end diastolic diameter,LVEDD)、左心室收缩末期内径(left ventricular end systolic diameter,LVESD)]、氨基末端脑钠肽前体(N-terminal pro-brain natriuretic peptide,NT-proBNP)浓度等。于术后12个月测定起搏参数(感知、阈值、阻抗、心室起搏比例),并统计心脏起搏器植入术后12个月内心力衰竭再入院、死亡等不良事件发生情况。结果术后各时间点观察组心功能指标LVEF、CO、CI略高于对照组,但两组比较差异无统计学意义(P>0.05)。术后各时间点观察组心腔大小指标RAD、LAD、LVEDD、LVESD低于对照组,尤其是术后12个月[RAD:(36.63±2.22)mm vs.(40.13±1.61)mm,LAD:(31.09±1.14)mm vs.(38.32±1.08)mm,LVEDD:(49.76±3.22)mm vs.(54.63±3.14)mm,LVESD:(40.64±2.11)mm vs.(48.11±3.24)mm,P<0.05]。术后各时间点观察组左心室收缩同步性指标LSDI、Tls-SD、Tls-dif、Trs-SD、Trs-dif、Tcs-SD、Tcs-dif均低于对照组,尤其是术后12个月[LSDI:4.86%±0.83%vs.9.49%±0.48%,Tls-SD:(14.42±1.78)ms vs.(25.00±1.43)ms,Tls-dif:(50.92±4.53)ms vs.(90.17±8.41)ms,Trs-SD:(50.37±4.33)ms vs.(69.44±6.52)ms,Trs-dif:(141.03±15.64)ms vs.(179.04±18.42)ms,Tcs-SD:(37.85±3.41)ms vs.(48.10±4.62)ms,Tcs-dif:(130.09±14.53)ms vs.(158.09±18.57)ms,P<0.05]。术后各时间点观察组NT-proBNP浓度略低于对照组,但两组比较差异无统计学意义(P>0.05)。两组起搏程控参数起搏感知、阻抗比较,差异无统计学意义(P<0.05);观察组起搏阈值低于对照组[(0.66±0.10)V vs.(0.75±0.12)V,P<0.05];两组起搏程控参数起搏感知、阻抗、阈值均处于正常范围。观察组心室起搏比例低于对照组(43.23%±4.53%vs.73.43%±6.56%,P<0.05)。术后12个月观察组心力衰竭再入院发生率明显低于对照组,差异有统计学意义(5.00%vs.22.50%,P<0.05)。结论左束支区域起搏技术在改善永久性心脏起搏器植入患者左心室收缩同步性、心功能方面优于右心室间隔起搏技术,术后12个月不良事件发生率较低,更有利于保护心功能,起搏参数稳定,属于一种有效且安全的起搏技术。展开更多
文摘Fifty-six patients with chest pain underwent selective coronaryangiography,radionuclide ventriculography (RNV) and frequency domaincardiography (FCG) to evaluate left ventricular function in coronary artery dis-ease (CAD).The sensitivity,specificity and accuracy of FCG were 87.5%,77.8%and 82.9%,respectively,which were slightly less than those of RNV (92.5%,88.9% and 90.8%,respectively).The changes of FCG scores were negatively corre-lated with changes of LVEF (r=-0.586,P【0.01),and TS (r=-0.679,P【0.01).These results indicate that FCG may be useful for the evaluation of leftventricular function in patients with CAD.
文摘目的探讨左束支区域起搏与右心室间隔起搏技术对老年患者左心室收缩同步性、心功能的影响。方法回顾性选取2022年2月至2023年3月期间于郴州市第一人民医院心血管内科接受永久性心脏起搏器植入术治疗的80例老年患者的临床资料,根据心脏起搏电极植入部位分为两组,即对照组、观察组各40例。对照组患者于右心室间隔处植入心脏起搏器,观察组患者于左束支区域植入心脏起搏器。分别于患者心脏起搏器植入术后1个月、术后6个月、术后12个月观察各指标变化,包括左心室收缩同步性参数[左心室收缩期纵向应变达峰时间标准差(time to peak longitudinal strain standard deviation,Tls-SD)、最大差值(time to peak longitudinal strain maximum difference,Tls-dif),左心室收缩期径向应变达峰时间标准差(time to peak radial strain standard deviation,Trs-SD)、最大差值(time to peak radial strain maximum difference,Trs-dif),左心室收缩期环向应变达峰时间标准差(time to peak circumferential strain standard deviation,Tcs-SD)、最大差值(time to peak circumferential strain maximum difference,Tcs-dif)]以及心功能指标[左心室射血分数(left ventricular ejection fraction,LVEF)、心排血量(cardiac output,CO)、心脏指数(cardiac index,CI)]、心腔大小[右心房内径(right atrial inner diameter,RAD)、左心房内径(left atrial diameter,LAD)、左心室舒张末期内径(left ventricular end diastolic diameter,LVEDD)、左心室收缩末期内径(left ventricular end systolic diameter,LVESD)]、氨基末端脑钠肽前体(N-terminal pro-brain natriuretic peptide,NT-proBNP)浓度等。于术后12个月测定起搏参数(感知、阈值、阻抗、心室起搏比例),并统计心脏起搏器植入术后12个月内心力衰竭再入院、死亡等不良事件发生情况。结果术后各时间点观察组心功能指标LVEF、CO、CI略高于对照组,但两组比较差异无统计学意义(P>0.05)。术后各时间点观察组心腔大小指标RAD、LAD、LVEDD、LVESD低于对照组,尤其是术后12个月[RAD:(36.63±2.22)mm vs.(40.13±1.61)mm,LAD:(31.09±1.14)mm vs.(38.32±1.08)mm,LVEDD:(49.76±3.22)mm vs.(54.63±3.14)mm,LVESD:(40.64±2.11)mm vs.(48.11±3.24)mm,P<0.05]。术后各时间点观察组左心室收缩同步性指标LSDI、Tls-SD、Tls-dif、Trs-SD、Trs-dif、Tcs-SD、Tcs-dif均低于对照组,尤其是术后12个月[LSDI:4.86%±0.83%vs.9.49%±0.48%,Tls-SD:(14.42±1.78)ms vs.(25.00±1.43)ms,Tls-dif:(50.92±4.53)ms vs.(90.17±8.41)ms,Trs-SD:(50.37±4.33)ms vs.(69.44±6.52)ms,Trs-dif:(141.03±15.64)ms vs.(179.04±18.42)ms,Tcs-SD:(37.85±3.41)ms vs.(48.10±4.62)ms,Tcs-dif:(130.09±14.53)ms vs.(158.09±18.57)ms,P<0.05]。术后各时间点观察组NT-proBNP浓度略低于对照组,但两组比较差异无统计学意义(P>0.05)。两组起搏程控参数起搏感知、阻抗比较,差异无统计学意义(P<0.05);观察组起搏阈值低于对照组[(0.66±0.10)V vs.(0.75±0.12)V,P<0.05];两组起搏程控参数起搏感知、阻抗、阈值均处于正常范围。观察组心室起搏比例低于对照组(43.23%±4.53%vs.73.43%±6.56%,P<0.05)。术后12个月观察组心力衰竭再入院发生率明显低于对照组,差异有统计学意义(5.00%vs.22.50%,P<0.05)。结论左束支区域起搏技术在改善永久性心脏起搏器植入患者左心室收缩同步性、心功能方面优于右心室间隔起搏技术,术后12个月不良事件发生率较低,更有利于保护心功能,起搏参数稳定,属于一种有效且安全的起搏技术。