Insulator defect detection plays a vital role in maintaining the secure operation of power systems.To address the issues of the difficulty of detecting small objects and missing objects due to the small scale,variable...Insulator defect detection plays a vital role in maintaining the secure operation of power systems.To address the issues of the difficulty of detecting small objects and missing objects due to the small scale,variable scale,and fuzzy edge morphology of insulator defects,we construct an insulator dataset with 1600 samples containing flashovers and breakages.Then a simple and effective surface defect detection method of power line insulators for difficult small objects is proposed.Firstly,a high-resolution featuremap is introduced and a small object prediction layer is added so that the model can detect tiny objects.Secondly,a simplified adaptive spatial feature fusion(SASFF)module is introduced to perform cross-scale spatial fusion to improve adaptability to variable multi-scale features.Finally,we propose an enhanced deformable attention mechanism(EDAM)module.By integrating a gating activation function,the model is further inspired to learn a small number of critical sampling points near reference points.And the module can improve the perception of object morphology.The experimental results indicate that concerning the dataset of flashover and breakage defects,this method improves the performance of YOLOv5,YOLOv7,and YOLOv8.In practical application,it can simply and effectively improve the precision of power line insulator defect detection and reduce missing detection for difficult small objects.展开更多
With the rapid development of high-speed-railway,environment around high voltage device on train roof becomes very complicated. Most train accidents happened due to occurrence of flashover on roof insulator,but the in...With the rapid development of high-speed-railway,environment around high voltage device on train roof becomes very complicated. Most train accidents happened due to occurrence of flashover on roof insulator,but the insulation condition estimation of insulator in such environment is much difficult. To ensure the insulation property of electric equipment,and guarantee the operation safety of high-speed-train,here established an instrument with high reliability which can on-line monitor insulation condition of roof insulator and give out advanced alarm before the incipient insulator flashover. The instrument consists of three parts,Data Acquisition & Sensor,Data Processing and Back Processing. Anti-interference and protection methods are processed to Rogowski coil sensor for better leakage current signal. To avoid the fluctuation from railway power supply,four modules are set to filter the power supply waveform. Through laboratory measurement,it is shown that the leakage current and the impedance angle can be detected by the instrument accurately. From the comparison of leakage current and impedance angle results under different moisture condition and the alarm operation when leakage current value reached threshold,this instrument can give out enough information for staff to understand the insulation condition of insulator.展开更多
基金State Grid Jiangsu Electric Power Co.,Ltd.of the Science and Technology Project(Grant No.J2022004).
文摘Insulator defect detection plays a vital role in maintaining the secure operation of power systems.To address the issues of the difficulty of detecting small objects and missing objects due to the small scale,variable scale,and fuzzy edge morphology of insulator defects,we construct an insulator dataset with 1600 samples containing flashovers and breakages.Then a simple and effective surface defect detection method of power line insulators for difficult small objects is proposed.Firstly,a high-resolution featuremap is introduced and a small object prediction layer is added so that the model can detect tiny objects.Secondly,a simplified adaptive spatial feature fusion(SASFF)module is introduced to perform cross-scale spatial fusion to improve adaptability to variable multi-scale features.Finally,we propose an enhanced deformable attention mechanism(EDAM)module.By integrating a gating activation function,the model is further inspired to learn a small number of critical sampling points near reference points.And the module can improve the perception of object morphology.The experimental results indicate that concerning the dataset of flashover and breakage defects,this method improves the performance of YOLOv5,YOLOv7,and YOLOv8.In practical application,it can simply and effectively improve the precision of power line insulator defect detection and reduce missing detection for difficult small objects.
基金supporting program of the National Science Foundation for Distinguished Young Scholars of China(Project No.51325704)the National Basic Research Program of China(973 Program,Project No.2011CB711105-4)。
文摘With the rapid development of high-speed-railway,environment around high voltage device on train roof becomes very complicated. Most train accidents happened due to occurrence of flashover on roof insulator,but the insulation condition estimation of insulator in such environment is much difficult. To ensure the insulation property of electric equipment,and guarantee the operation safety of high-speed-train,here established an instrument with high reliability which can on-line monitor insulation condition of roof insulator and give out advanced alarm before the incipient insulator flashover. The instrument consists of three parts,Data Acquisition & Sensor,Data Processing and Back Processing. Anti-interference and protection methods are processed to Rogowski coil sensor for better leakage current signal. To avoid the fluctuation from railway power supply,four modules are set to filter the power supply waveform. Through laboratory measurement,it is shown that the leakage current and the impedance angle can be detected by the instrument accurately. From the comparison of leakage current and impedance angle results under different moisture condition and the alarm operation when leakage current value reached threshold,this instrument can give out enough information for staff to understand the insulation condition of insulator.