期刊文献+
共找到71篇文章
< 1 2 4 >
每页显示 20 50 100
An overview on observational instruments and measuring methods for dewfall 被引量:1
1
作者 Qiang Zhang XiaoCui Hao +2 位作者 XiaoMei Wen Sheng Wang Jian Zeng 《Research in Cold and Arid Regions》 2011年第1期78-85,共8页
This paper systematically summarizes previous measuring methods and observational instruments for the magnitude of dewfall on land surface, analyzes the characteristics of common observational instruments for land sur... This paper systematically summarizes previous measuring methods and observational instruments for the magnitude of dewfall on land surface, analyzes the characteristics of common observational instruments for land surface dewfall, and describes several basic dewfall measurement methods. Moreover, the basic principles of these methods and instruments are interpreted, and their advantages, disadvantages, and applicability are analyzed. Recommendations for the further improvement of these observational instruments and the development of dewfall measuring methods are presented, and new technologies and scientific proposals for exploiting dewfall are elucidated. 展开更多
关键词 dewfall measuring methods observational instrument exploitation and utilization technology
下载PDF
Measuring methods for three kinds of polyhydroxyalkanoates from activated sludge by gas chromatography
2
作者 陈玮 陈志强 +2 位作者 吕炳南 温沁雪 张运海 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期113-118,共6页
Gas chromatography determination of polyhydroxyalkanoates has been common;however,the pretreatment steps are often complex,and gas chromatography operation conditions are not given in detail.In this study,gas chromato... Gas chromatography determination of polyhydroxyalkanoates has been common;however,the pretreatment steps are often complex,and gas chromatography operation conditions are not given in detail.In this study,gas chromatography is used for analyzing PHB,PHV and PH2MV,three majors of PHAs in activated sludge.The sample was centrifuged at a speed of 4000 r/min for the separation of floc and supernatant,freezen,and dried for 12 h in vacuum freezing drier;and then transferred to the fridge for freezing to ice and drying for 12 h in vacuum freezing drier;then chloroform and a simple composition digestion solution including methanol,sulfuric acid and benzoic acid was added;digested at 105 ℃ for 6 h;cooled to room temperature,the lower solution of the result can be used for analyzing.Samples were analyzed by gas chromatography with FID detector and auto sampler;the standard curve of standard material shows an excellent linear relationship with correlation coefficients larger than 0.99;the relative standard deviation (RSD) of sludge samples is less than 1%.The recovery rates of each sample are between 95%-105%.The GC analysis time of each PHA sample is shorter than 10 minutes. 展开更多
关键词 POLYHYDROXYALKANOATES activated sludge gas chromatography measuring method
下载PDF
Drilling-based measuring method for the c-φ parameter of rock and its field application 被引量:2
3
作者 Bei Jiang Fenglin Ma +5 位作者 Qi Wang Hongke Gao Dahu Zhai Yusong Deng Chuanjie Xu Liangdi Yao 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第1期65-76,共12页
The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(R... The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters. 展开更多
关键词 Digital drilling Rock crushing zone c-u parameter Measurement method Field application
下载PDF
The effect of the different labeling and red cell removed methods on measuring the CD34^+cells of the cord blood
4
《中国输血杂志》 CAS CSCD 2001年第S1期415-,共1页
关键词 cells of the cord blood CD The effect of the different labeling and red cell removed methods on measuring the CD34
下载PDF
Magnetic field regression using artificial neural networks for cold atom experiments
5
作者 陈子霆 黃建陶 +6 位作者 Bojeong Seo 黄明琛 Mithilesh K.Parit 何逸飞 甄浩廷 Jensen Li Gyu-Boong Jo 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期46-51,共6页
Accurately measuring magnetic fields is essential for magnetic-field sensitive experiments in areas like atomic,molecular,and optical physics,condensed matter experiments,and other areas.However,since many experiments... Accurately measuring magnetic fields is essential for magnetic-field sensitive experiments in areas like atomic,molecular,and optical physics,condensed matter experiments,and other areas.However,since many experiments are often conducted in an isolated environment that is inaccessible to experimentalists,it can be challenging to accurately determine the magnetic field at the target location.Here,we propose an efficient method for detecting magnetic fields with the assistance of an artificial neural network(NN).Instead of measuring the magnetic field directly at the desired location,we detect fields at several surrounding positions,and a trained NN can accurately predict the magnetic field at the target location.After training,we achieve a below 0.3%relative prediction error of magnetic field magnitude at the center of the vacuum chamber,and successfully apply this method to our erbium quantum gas apparatus for accurate calibration of magnetic field and long-term monitoring of environmental stray magnetic field.The demonstrated approach significantly simplifies the process of determining magnetic fields in isolated environments and can be applied to various research fields across a wide range of magnetic field magnitudes. 展开更多
关键词 ultracold gases trapped gases measurement methods and instrumentation
下载PDF
Study on Measurement Methods of Multi-Directional Waves—Wave Gauge Array Method 被引量:5
6
作者 Yu Yuxiu Liu Shuxue Prof. Department of Civil Engineering, Dalian University of Technology, Dalian Assistant Researcher, Department of Civil Engineering, Dalian University of Technology, Dalian 《China Ocean Engineering》 SCIE EI 1992年第2期233-242,共10页
Measuring multi-directional waves with the wave gauge array is one of the fundamental and easily realised methods. In this paper, the wave gauge array is described and the effects of the gauge spacing, the array orien... Measuring multi-directional waves with the wave gauge array is one of the fundamental and easily realised methods. In this paper, the wave gauge array is described and the effects of the gauge spacing, the array orientations, etc. of the three array arrangements, i. e., linear array, T-type array and pentagon array, on the resolution of the directional spreading of waves, are investigated experimentally. This study can be used as a reference in the experimental study and the field measurement of directional waves. 展开更多
关键词 multi-directional waves measurement method directional spectrum wave gauge array
下载PDF
A review of welding residual stress test methods 被引量:7
7
作者 甘世明 刘华荥 +1 位作者 翟之平 韩永全 《China Welding》 CAS 2022年第2期45-55,共11页
Due to local uneven heating during the welding process,the residual stress of the structure after welding affects the reliability of it.In order to ensure the reliability,it is of great significance to test the residu... Due to local uneven heating during the welding process,the residual stress of the structure after welding affects the reliability of it.In order to ensure the reliability,it is of great significance to test the residual stress distribution of the welded joint.It has always been the focus to find a simple and feasible method for residual stress testing to quickly and accurately obtain the residual stress distribution of welded joints.The mechanical measurement method has high measurement accuracy,convenient and easy operation,but it will cause certain damage to the components.Physical measurement method can avoid damage to components,but its test cost is usually high,and its measurement accuracy can also be affected by the material microstructure characteristics of welded components.Based on the advantages and disadvantages of these two residual stress test methods,a modal test method is proposed.This method is a non-destructive measurement method.Based on the mathematical relationship between the residual stress of the welded structure and the natural frequency(mathematical model),the natural frequency is measured through the modal test to calculate the residual stress quickly.However,it is difficult to establish a mathematical model with this method,and it is not suitable for realization. 展开更多
关键词 welding residual stress mechanical measurement method physical measurement method modal test method
下载PDF
Self-heating Probe Instrument and Method for Measuring High Temperature Melting Volume Change Rate of Material 被引量:2
8
作者 WANG Junwei WANG Zhiping +1 位作者 LU Yang CHENG Bo 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第2期371-376,共6页
The castings defects are affected by the melting volume change rate of material. The change rate has an important effect on running safety of the high temperature thermal storage chamber, too. But the characteristics ... The castings defects are affected by the melting volume change rate of material. The change rate has an important effect on running safety of the high temperature thermal storage chamber, too. But the characteristics of existing measuring installations are complex structure, troublesome operation and low precision. In order to measure the melting volume change rate of material accurately and conveniently, a self-designed measuring instrument, self-heating probe instrument, and measuring method are described. Temperature in heating cavity is controlled by PID temperature controller; melting volume change rate υ and molten density are calculated based on the melt volume which is measured by the instrument. Positive and negative υ represent expansion and shrinkage of the sample volume after melting, respectively. Taking eutectic LiF+CaF2 for example, its melting volume change rate and melting density at 1 123 K are -20.6% and 2 651 kg/m–3 measured by this instrument, which is only 0.71% smaller than literature value. Density and melting volume change rate of industry pure aluminum at 973 K and analysis pure NaCl at 1 123 K are detected by the instrument too. The measure results are agreed with report values. Measuring error sources are analyzed and several improving measures are proposed. In theory, the measuring errors of the change rate and molten density which are measured by the self-designed instrument is nearly 1/20-1/50 of that measured by the refitted mandril thermal expansion instrument. The self-designed instrument and method have the advantages of simple structure, being easy to operate, extensive applicability for material, relatively high accuracy, and most importantly, temperature and sample vapor pressure have little effect on the measurement accuracy. The presented instrument and method solve the problems of complicated structure and procedures, and large measuring errors for the samples with high vapor pressure by existing installations. 展开更多
关键词 high temperature volume expansion rate molten density measuring instrument measuring method
下载PDF
Measurement methods and analysis tools for rail irregularities:a case study for urban tram track 被引量:3
9
作者 Laura Chiacchiari Giuseppe Loprencipe 《Journal of Modern Transportation》 2015年第2期137-147,共11页
Rail irregularities, in particular for urban rail- way infrastructures, are one of the main causes for the generation of noise and vibrations. In addition, repetitive loading may also lead to decay of the structural e... Rail irregularities, in particular for urban rail- way infrastructures, are one of the main causes for the generation of noise and vibrations. In addition, repetitive loading may also lead to decay of the structural elements of the rolling stock. This further causes an increase in main- tenance costs and reduction of service life. Monitoring these defects on a periodic basis enables the network rail managers to apply proactive measures to limit further damage. This paper discusses the measurement methods for rail corrugation with particular regard to the analysis tools for evaluating the thresholds of acceptability in re- lation to the tramway Italian transport system. Further- more, a method of analysis has been proposed: an application of the methodology used for treating road profiles has been also utilized for the data processing of rail profilometric data. 展开更多
关键词 Rail corrugation Noise disturbance Measurement methods Continuous measurement Dataprocessing algorithm Wavebands filtering
下载PDF
Analysis and Application of the Synthetic Relative Measuring Method in On-Line Monitoring for Capacitive Equipment in Power Systems
10
作者 Qing Guo Li-Jun Qin Hua-Wei Jin 《Journal of Electronic Science and Technology》 CAS 2011年第3期270-277,共8页
On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings... On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings of traditional absolute measuring methods but also greatly improve the accuracy of dielectric loss angle measurement. However, synthetic relative measuring methods based on two or three pieces of capacitive equipment do not have the characteristic of generality. In this paper, a principle of synthetic relative measuring method is presented. The example of application for synthetic relative methods based on three and four pieces of capacitive equipment running in the same phase is taken to present the failure judgment matrices for N pieces of equipment. According to these matrices, the fault condition of N pieces of capacitive equipment can be watched, which is more general. Then some problems needing to be concerned along with two diagnostic methods used in diagnostic system are introduced. Finally, two programmable flow charts for the two methods are given and corresponding examples demonstrate their feasibility in practice. 展开更多
关键词 Index Terms-Capacitive equipment dielectric loss angle on-line monitoring synthetic relative measuring method failure judgment matrix.
下载PDF
A New Method for Measuring the Wall Charge Waveforms of AC PDP
11
作者 梁志虎 刘祖军 刘纯亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第6期2567-2570,共4页
A new method is developed to measure the wall charge waveforms in coplanar alternating current plasma display panel (AC PDP). In the method, two groups of display electrodes are selected from a coplanar AC PDP and two... A new method is developed to measure the wall charge waveforms in coplanar alternating current plasma display panel (AC PDP). In the method, two groups of display electrodes are selected from a coplanar AC PDP and two capacitors are respectively connected with these two groups of display electrodes in series, and a measuring circuit and a reference circuit are thus constructed. With the help of special processing, discharge takes place in the cells included in the measuring circuit under a normal drive voltage but no discharge takes place in the cells included in the reference circuit under a normal drive voltage. The wall charge waveforms are obtained from the voltage difference between the two capacitors. Using the method, the wall charge waveforms are measured during resetting period, addressing period and sustaining period for the 304.8mm (12-inch) test PDP panel. The result shows that the wall voltage is about 96V during the sustaining period. 展开更多
关键词 plasma display panel wall charge measuring method
下载PDF
Thickness Method for Measuring Hair Density of Rex Rabbit
12
作者 Gao Haiqi Li Bingjing +1 位作者 Liu Han Zhang Zongcai 《Animal Husbandry and Feed Science》 CAS 2018年第2期81-83,108,共4页
[Objective] The paper was to characterize hair density by changes in hair thickness under certain pressure.[Method] Tile effects of weight of thickness tester and wafer urea at the hottom of presser foot on measuremen... [Objective] The paper was to characterize hair density by changes in hair thickness under certain pressure.[Method] Tile effects of weight of thickness tester and wafer urea at the hottom of presser foot on measurement results were studied, and the optimal measuring weight and wafer diameter was determined. The measurement results of hair thickness under the ahove condition were compared with the results of manual counting. Meanwhile, the effects of hair length and hair fineness on hair density were analyzed.[Result] The hair density obtained by manual count- ing had consistent change trend with the hair thickness measured under certain conditions. If the length and fineness of hairs were introduced for modification, the correlation between hair thickness and hair density would be better. There were little changes in hair length and finelless of rex rabbit, and their effects on hair thickness could be ignored under general condition. [Conclusion] It is completely feasible to characterize hair den- sity of rex rabbit by hair thickness under pressure. 展开更多
关键词 Rex rabbit Hair density Measurement method Thickness
下载PDF
Application of a Soil Nutrient Measuring Instrument in Vegetable Seedling Substrate
13
作者 Wang Pengcheng Zhang Jian +4 位作者 Tian Hongmei Jiang Haikun Wang Yan Wang Mingxia Fang Ling 《Meteorological and Environmental Research》 CAS 2015年第11期39-42,共4页
[Objective] The aim was to find an efficient method to measure available nitrogen, phosphorus and potassium content in vegetable seedling substrate. [ Method] The suitable dosage of leaching agent, ratio of the substr... [Objective] The aim was to find an efficient method to measure available nitrogen, phosphorus and potassium content in vegetable seedling substrate. [ Method] The suitable dosage of leaching agent, ratio of the substrate to water and leaching time for the detection of nutrient contents in the substrate by a soil nutrient measuring instrument were discussed firstly, and then the results of nutrient contents measured by the soil nutrient measuring instrument were compared with that by conventional approaches. [ Result] In compadson with the conventional methods, the av- erage content of available nitrogen measured by the soil nutrient measuring instrument was slightly higher, while the average content of available phosphorus measured by the instrument was lower; the average content of available potassium measured by the instrument was close to that by the conventional method. [ Conclusion] This study could provide us a new method to detect available nitrogen, phosphorus and potassium content in seedling substrate efficiently. 展开更多
关键词 Soil nutrient measuring instrument Seedling substrate Available nitrogen Available phosphorus Available potassium Measurement method
下载PDF
Express Methods for Measurement of Electroconductivity of Semiconductor Layered Crystal
14
作者 FILIPPOV V. V. VLASOV A. N. 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第11期114-117,共4页
We describe theoretically the grounded method of measuring the conductivity of anisotropic layered semiconductor materials. The suggested method implies the use of a four-probe testing device with a linear arrangement... We describe theoretically the grounded method of measuring the conductivity of anisotropic layered semiconductor materials. The suggested method implies the use of a four-probe testing device with a linear arrangement of probes. The final expressions for identifying the electrical conductivity are presented in the form of a series of analytic functions. The suggested method is experimentally verified, and practical recommendations of how to apply it are also provided. 展开更多
关键词 Express methods for Measurement of Electroconductivity of Semiconductor Layered Crystal
下载PDF
Recent progress in research and design concepts for the characterization,testing,and photocatalysts for nitrogen reduction reaction
15
作者 Benteng Sun Shucao Lu +2 位作者 Yeye Qian Xiaoli Zhang Jian Tian 《Carbon Energy》 SCIE CSCD 2023年第3期19-74,共56页
The reduction of molecular nitrogen(N_(2))to ammonia(NH_(3))under mild conditions is one of the most promising studies in the energy field due to the important role of NH_(3)in modern industry,production,and life.The ... The reduction of molecular nitrogen(N_(2))to ammonia(NH_(3))under mild conditions is one of the most promising studies in the energy field due to the important role of NH_(3)in modern industry,production,and life.The photocatalytic reduction of N_(2)is expected to achieve clean and sustainable NH_(3)production by using clean solar energy.To date,the new photocatalysts for photocatalytic reduction of N_(2)to NH_(3)at room temperature and atmospheric pressure have not been fully developed.The major challenge is to achieve high light-absorption efficiency,conversion efficiency,and stability of photocatalysts.Herein,the methods for measuring produced NH_(3)are compared,and the problems related to possible NH_(3)pollution in photocatalytic systems are mentioned to provide accurate ideas for measuring photocatalytic efficiency.The recent progress of nitrogen reduction reaction(NRR)photocatalysts at ambient temperature and pressure is summarized by introducing charge transfer,migration,and separation in photocatalytic NRR,which provides a guidance for the selection of future photocatalyst.More importantly,we introduce the latest research strategies of photocatalysts in detail,which can guide the preparation and design of photocatalysts with high NRR activity. 展开更多
关键词 nitrogen reduction reaction PHOTOCATALYSTS produced NH 3 measuring methods reaction mechanism research strategy
下载PDF
A review on stress determination and control in metal-based additive manufacturing 被引量:2
16
作者 Haoyang Luo Xing Sun +2 位作者 Le Xu Wei He Xiaoyu Liang 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2023年第1期14-25,共12页
Metal additive manufacturing(MAM)is an emerging and disruptive technology that builds three-dimensional(3D)components by adding layer-upon-layer of metallic materials.The complex cyclic thermal history and highly loca... Metal additive manufacturing(MAM)is an emerging and disruptive technology that builds three-dimensional(3D)components by adding layer-upon-layer of metallic materials.The complex cyclic thermal history and highly localized energy can produce large temperature gradients,which will,in turn,lead to compressive and tensile stress during the MAM process and eventually result in residual stress.Being an issue of great concern,residual stress,which can cause distortion,delamination,cracking,etc.,is considered a key mechanical quantity that affects the manufacturing quality and service performance of MAM parts.In this review paper,the ongoing work in the field of residual stress determination and control for MAM is described with a particular emphasis on the experimental measurement/control methods and numerical models.We also provide insight on what still requires to be achieved and the research opportunities and challenges. 展开更多
关键词 Metal additive manufacturing Residual stress Measurement and control methods Numerical models
下载PDF
Greenhouse gas emission analysis and measurement for urban rail transit: A review of research progress and prospects 被引量:1
17
作者 Zhenzhou Yuan Xiaojing Yuan +4 位作者 Yang Yang Jinjie Chen Yingjie Nie Meng Cao Long Chen 《Digital Transportation and Safety》 2023年第1期36-51,共16页
Rail transit plays a key role in mitigating transportation system carbon emissions.Accurate measurement of urban rail transit carbon emission can help quantify the contribution of urban rail transit towards urban tran... Rail transit plays a key role in mitigating transportation system carbon emissions.Accurate measurement of urban rail transit carbon emission can help quantify the contribution of urban rail transit towards urban transportation carbon emission reduction.Since the whole life cycle of urban rail transit carbon emission measurement involves a wide range of aspects,a systematic framework model is required for analysis.This research reviews the existing studies on carbon emission of urban rail transit.First,the characteristics of urban rail transit carbon emission were determined and the complexity of carbon emission measurement was analyzed.Then,the urban rail transit carbon emission measurement models were compared and analyzed in terms of the selection of research boundaries,the types of greenhouse gas(GHG)emissions calculation,and the accuracy of the measurement.Following that,an intelligent station was introduced to analyze the practical application of digital collaboration technology and energy-saving and carbon-reducing system platforms for rail transit.Finally,the urgent problems and future research directions at this stage were discussed.This research presents the necessity of establishing a dynamic carbon emission factor library and the important development trend of system integration of carbon emission measurement and digital system technology. 展开更多
关键词 Urban rail transit Life cycle assessment(LCA) Greenhouse gas emission Digital collaboration technology Carbon emission factors Climate change Measurement method
下载PDF
Method with reliable accuracy and fast speed for measuring operational current of HTS NI closed-loop coils in steady persistent-current-mode
18
作者 Li Lu Wei Wu +5 位作者 Xin Yu Zhuoyan Zhong Kai Li Chengyun Pan Mengzhu Li Zhijian Jin 《Superconductivity》 2024年第1期65-73,共9页
This study proposes a method for measuring the operational current of high temperature superconducting(HTS)non‐insulation(NI)closed‐loop coils,which operate in the steady persistent‐current‐mode(PCM).HTS NI closed... This study proposes a method for measuring the operational current of high temperature superconducting(HTS)non‐insulation(NI)closed‐loop coils,which operate in the steady persistent‐current‐mode(PCM).HTS NI closed‐loop coils are promising for many easily‐quenching direct‐current(DC)applications,where their performance is determined by magnetomotive forces,total number of turns,and dimensions.As the primary interface parameter in an application system,the operational current must be accurately and rapidly measured.Generally,this is achieved by dividing the measured magnetic field by the coil constant.However,even if the influence of the screening current induced field(SCIF)is not considered,existing methods for the coil constant may be disturbed by the performance and location of Hall sensors,or experience a long measuring period.Therefore,a relatively accurate and fast method is proposed in this study,which is based on adjusting the output current of the adjustable power supply and monitoring the coil voltage as an indicator.The proposed method was validated through experiments and simulations using an equivalent circuit model coupled with a finite element method(FEM)model,and its current accuracy can be equivalent to the resolution of the employed power supply.It was demonstrated that this method reduced the requirements for Hall sensor’s performance and location,and has a more reliable accuracy in contrast to the simulation method.Compared to the experimentally conventional method,the proposed method presents a significantly faster speed.The impact of the SCIF was considered and proven to be negligible for the tested pancake coils.Even for coils whose coil constant vibrates owing to the SCIF,this method can be adapted to directly measure various operational currents.Furthermore,it was demonstrated that the measurement error can be influenced by the current discrepancy among turns when the coil is not in the steady PCM,and a procedure for reducing this error was proposed. 展开更多
关键词 Operational current HTS NI closed‐loop coils Measurement method Adjustable power supply Coil voltage
原文传递
Simultaneous estimation of aerosol optical constants and size distribution from angular light-scattering measurement signals 被引量:3
19
作者 贺振宗 梁栋 +1 位作者 毛军逵 韩省思 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第5期564-572,共9页
The angular light-scattering measurement(ALSM) method combined with an improved artificial bee colony algorithm is introduced to determine aerosol optical constants and aerosol size distribution(ASD) simultaneousl... The angular light-scattering measurement(ALSM) method combined with an improved artificial bee colony algorithm is introduced to determine aerosol optical constants and aerosol size distribution(ASD) simultaneously. Meanwhile, an optimized selection principle of the ALSM signals based on the sensitivity analysis and principle component analysis(PCA)is proposed to improve the accuracy of the retrieval results. The sensitivity analysis of the ALSM signals to the optical constants or characteristic parameters in the ASD is studied first to find the optimized selection region of measurement angles. Then, the PCA is adopted to select the optimized measurement angles within the optimized selection region obtained by sensitivity analysis. The investigation reveals that, compared with random selection measurement angles, the optimized selection measurement angles can provide more useful measurement information to ensure the retrieval accuracy. Finally,the aerosol optical constants and the ASDs are reconstructed simultaneously. The results show that the retrieval accuracy of refractive indices is better than that of absorption indices, while the characteristic parameters in ASDs have similar retrieval accuracy. Moreover, the retrieval accuracy in studying L-N distribution is a little better than that in studying Gamma distribution for the difference of corresponding correlation coefficient matrixes of the ALSM signals. All the results confirm that the proposed technique is an effective and reliable technique in estimating the aerosol optical constants and ASD simultaneously. 展开更多
关键词 angular light-scattering measurement method aerosol optical constants aerosol size distribution inverse radiation problem
下载PDF
Measurement Uncertainty Evaluation of Conicity Error Inspected on CMM 被引量:11
20
作者 WANG Dongxia SONG Aiguo +2 位作者 WEN Xiulan XU Youxiong QIAO Guifang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2016年第1期212-218,共7页
The cone is widely used in mechanical design for rotation, centering and fixing. Whether the conicity error can be measured and evaluated accurately will directly influence its assembly accuracy and working performanc... The cone is widely used in mechanical design for rotation, centering and fixing. Whether the conicity error can be measured and evaluated accurately will directly influence its assembly accuracy and working performance. According to the new generation geometrical product specification(GPS), the error and its measurement uncertainty should be evaluated together. The mathematical model of the minimum zone conicity error is established and an improved immune evolutionary algorithm(IlEA) is proposed to search for the conicity error. In the IIEA, initial antibodies are firstly generated by using quasi-random sequences and two kinds of affinities are calculated. Then, each antibody clone is generated and they are self-adaptively mutated so as to maintain diversity. Similar antibody is suppressed and new random antibody is generated. Because the mathematical model of conicity error is strongly nonlinear and the input quantities are not independent, it is difficult to use Guide to the expression of uncertainty in the measurement(GUM) method to evaluate measurement uncertainty. Adaptive Monte Carlo method(AMCM) is proposed to estimate measurement uncertainty in which the number of Monte Carlo trials is selected adaptively and the quality of the numerical results is directly controlled. The cone parts was machined on lathe CK6140 and measured on Miracle NC 454 Coordinate Measuring Machine(CMM). The experiment results confirm that the proposed method not only can search for the approximate solution of the minimum zone conicity error(MZCE) rapidly and precisely, but also can evaluate measurement uncertainty and give control variables with an expected numerical tolerance. The conicity errors computed by the proposed method are 20%-40% less than those computed by NC454 CMM software and the evaluation accuracy improves significantly. 展开更多
关键词 minimum zone conicity error improved immune evolutionary algorithm measurement uncertainty adaptive Monte Carlo method
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部