We investigate the dynamic characteristics of oil-gas-water three-phase flow in terms of chaotic attractor comparison. In particular, we extract a statistic to characterize the dynamical difference in attractor probab...We investigate the dynamic characteristics of oil-gas-water three-phase flow in terms of chaotic attractor comparison. In particular, we extract a statistic to characterize the dynamical difference in attractor probability distribution. We first take time series from Logistic chaotic system with different parameters as examples to demonstrate the effectiveness of the method. Then we use this method to investigate the experimental signals from oil-gas-water three-phase flow. The results indicate that the extracted statistic is very sensitive to the change of flow parameters and can gain a quantitatively insight into the dynamic characteristics of different flow patterns.展开更多
A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of ...A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of the two compared signals. It utilizes the regular phase shift characteristics between the signals. The resolution of the measurement approach can reach 10^-13/s at 5 MHz, and the self-calibration resolution can achieve 10^-14/s in the comparison between 10 MHz and 100 MHz, or even can reach 10^-15/s in the comparison between 10 MHz and 190 MHz. This method implies significant progress in the development of the high precision frequency standard comparison technology.展开更多
大规模风电、光伏新能源经交流送出系统中,送出线路发生故障后,新能源电源控制的故障响应严重影响交流线路距离保护的动作性能。该文分析了新能源电源典型控制策略对故障后电源等值阻抗及系统功角的影响,故障后电源等值阻抗和系统功角...大规模风电、光伏新能源经交流送出系统中,送出线路发生故障后,新能源电源控制的故障响应严重影响交流线路距离保护的动作性能。该文分析了新能源电源典型控制策略对故障后电源等值阻抗及系统功角的影响,故障后电源等值阻抗和系统功角显著增大。进一步研究了不同类型距离保护的动作性能。针对测距式距离保护,揭示了线路正向区外或反向区外发生经过渡电阻故障时保护误动、线路正向区内故障时保护拒动机理。针对比相式距离保护,揭示了正序极化电压相位受控偏移导致线路区内相间短路故障时保护拒动、区外反向故障时保护误动机理。利用实时数字仿真平台(real time digital simulation system,RTDS)建立了仿真模型,利用仿真结果和现场实际误动数据验证了理论分析的正确性,为大规模新能源送出线路故障分析和后备保护配置提供了理论依据。展开更多
We analyze the phenomena of phase group synchronization between the different nominal frequency signals and propose a new theory of the equivalent comparison between them. The exact expression of the equivalent compar...We analyze the phenomena of phase group synchronization between the different nominal frequency signals and propose a new theory of the equivalent comparison between them. The exact expression of the equivalent comparison is deduced. High resolution frequency measurement and phase comparison can be realized using this theory with the divider. For avoiding the frequency mixing, multiplication and synthesis, the system phase noise is improved and the higher resolution comparison and measurement are achieved between the different nominal frequencies by theory.展开更多
新能源电源经柔性直流输电线路接入交流系统已经成为电力系统中的典型场景。以基于模块化多电平换流器的柔性直流(modular multilevel converter-high voltage direct current,MMC-HVDC)受端交流线路配置的正序电压为极化电压的比相式...新能源电源经柔性直流输电线路接入交流系统已经成为电力系统中的典型场景。以基于模块化多电平换流器的柔性直流(modular multilevel converter-high voltage direct current,MMC-HVDC)受端交流线路配置的正序电压为极化电压的比相式距离保护为研究对象,结合受端换流器的控制策略,分析了新能源经柔性高压直送出系统中柔直受端交流线路发生短路故障场景下该保护的适应性:在发生相间金属性短路故障情况下,距离保护存在区内短路拒动以及反向区外短路误动的风险。为探究保护不正确动作机制,首先在电压平面上分析了参量变化对距离保护动作行为的影响,揭示了距离保护内在的系统功角与短路容量约束,推导了距离保护正确动作的功角边界。通过将柔直侧系统进行合理等值,受端交流线路发生相间金属性短路故障后,受端换流器控制策略使得系统等值功角增大,距离保护特性位于动作边界,存在拒动/误动风险。利用RTDS建立了风电经柔直送出系统的仿真模型,分析了受端交流线路故障后系统的等值功角特征,验证了距离保护的不正确动作特性。展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.41174109 and 61104148)the National Science and Technology Major Project of the Ministry of Science and Technology of China(Grant No.2011ZX05020-006)the Tianjin City High School Science and Technology Fund Planning Project,China(Grant No.20130718)
文摘We investigate the dynamic characteristics of oil-gas-water three-phase flow in terms of chaotic attractor comparison. In particular, we extract a statistic to characterize the dynamical difference in attractor probability distribution. We first take time series from Logistic chaotic system with different parameters as examples to demonstrate the effectiveness of the method. Then we use this method to investigate the experimental signals from oil-gas-water three-phase flow. The results indicate that the extracted statistic is very sensitive to the change of flow parameters and can gain a quantitatively insight into the dynamic characteristics of different flow patterns.
基金supported by the National Natural Science Foundation of China (Grant Nos.60772135 and 10978017)the Open Fund of Key Laboratory of Precision Navigation and Technology,National Time Service Center,Chinese Academy of Sciences (Grant No.2009PNTT10)the Fundamental Research Funds for the Central Universities,China (Grant No.JY10000905015)
文摘A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of the two compared signals. It utilizes the regular phase shift characteristics between the signals. The resolution of the measurement approach can reach 10^-13/s at 5 MHz, and the self-calibration resolution can achieve 10^-14/s in the comparison between 10 MHz and 100 MHz, or even can reach 10^-15/s in the comparison between 10 MHz and 190 MHz. This method implies significant progress in the development of the high precision frequency standard comparison technology.
文摘大规模风电、光伏新能源经交流送出系统中,送出线路发生故障后,新能源电源控制的故障响应严重影响交流线路距离保护的动作性能。该文分析了新能源电源典型控制策略对故障后电源等值阻抗及系统功角的影响,故障后电源等值阻抗和系统功角显著增大。进一步研究了不同类型距离保护的动作性能。针对测距式距离保护,揭示了线路正向区外或反向区外发生经过渡电阻故障时保护误动、线路正向区内故障时保护拒动机理。针对比相式距离保护,揭示了正序极化电压相位受控偏移导致线路区内相间短路故障时保护拒动、区外反向故障时保护误动机理。利用实时数字仿真平台(real time digital simulation system,RTDS)建立了仿真模型,利用仿真结果和现场实际误动数据验证了理论分析的正确性,为大规模新能源送出线路故障分析和后备保护配置提供了理论依据。
基金supported by the National Natural Science Foundation of China(Grant Nos.10978017 and 61201288)the Fundamental Research Funds for the Central Universities,China(Grant No.JB140413)
文摘We analyze the phenomena of phase group synchronization between the different nominal frequency signals and propose a new theory of the equivalent comparison between them. The exact expression of the equivalent comparison is deduced. High resolution frequency measurement and phase comparison can be realized using this theory with the divider. For avoiding the frequency mixing, multiplication and synthesis, the system phase noise is improved and the higher resolution comparison and measurement are achieved between the different nominal frequencies by theory.
文摘新能源电源经柔性直流输电线路接入交流系统已经成为电力系统中的典型场景。以基于模块化多电平换流器的柔性直流(modular multilevel converter-high voltage direct current,MMC-HVDC)受端交流线路配置的正序电压为极化电压的比相式距离保护为研究对象,结合受端换流器的控制策略,分析了新能源经柔性高压直送出系统中柔直受端交流线路发生短路故障场景下该保护的适应性:在发生相间金属性短路故障情况下,距离保护存在区内短路拒动以及反向区外短路误动的风险。为探究保护不正确动作机制,首先在电压平面上分析了参量变化对距离保护动作行为的影响,揭示了距离保护内在的系统功角与短路容量约束,推导了距离保护正确动作的功角边界。通过将柔直侧系统进行合理等值,受端交流线路发生相间金属性短路故障后,受端换流器控制策略使得系统等值功角增大,距离保护特性位于动作边界,存在拒动/误动风险。利用RTDS建立了风电经柔直送出系统的仿真模型,分析了受端交流线路故障后系统的等值功角特征,验证了距离保护的不正确动作特性。