The dosage of environmental radon progeny is typically estimated according to the environmental radon exposure and the recommended radon-progeny equilibrium factor, F. To investigate the relationship between PM2.5 and...The dosage of environmental radon progeny is typically estimated according to the environmental radon exposure and the recommended radon-progeny equilibrium factor, F. To investigate the relationship between PM2.5 and the radon-progeny equilibrium factor, cigarettes are used to simulate the haze–fog in a multi-functional radon chamber to achieve a stable radon concentration environment. A radon detector and a portable laser aerosol spectrometer are used to obtain the values for C_(mean) PM2.5,C_(Rn), and C_p. The results show that the mean values of F conform with the typical value recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation and are within the reasonable range of0.1–0.9. In this study, a positive correlation is observed between the F values and PM2.5 concentrations.展开更多
Radon(Rn)is a naturally occurring radioactive inert gas in nature,and^(222)Rn has been routinely used as a powerful tracer in various aquatic environmental research on timescales of hours to days,such as submarine gro...Radon(Rn)is a naturally occurring radioactive inert gas in nature,and^(222)Rn has been routinely used as a powerful tracer in various aquatic environmental research on timescales of hours to days,such as submarine groundwater discharge.Here we developed a new approach to measure^(222)Rn in discrete water samples with a wide range of^(222)Rn concentrations using a Pulsed Ionization Chamber(PIC)Radon Detector.The sensitivity of the new PIC system is evaluated at 6.06 counts per minute for 1 Bq/L when a 500 mL water sample volume is used.A robust logarithmic correlation between sample volumes,ranging from 250 mL to 5000 mL,and system sensitivity obtained in this study strongly suggests that this approach is suitable for measuring radon concentration levels in various natural waters.Compared to the currently available methods for measuring radon in grab samples,the PIC system is cheaper,easier to operate and does not require extra accessories(e.g.,drying tubes etc.)to maintain stable measurements throughout the counting procedure.展开更多
基金supported by the National Natural Science Foundation of China(No.11565002)the Jiang Xi Young Science Foundation Project(No.GJJ150558)Open Funds of Engineering Research Center of Nuclear Technology Application of Ministry of Education(No.HJSJYB2017-2)
文摘The dosage of environmental radon progeny is typically estimated according to the environmental radon exposure and the recommended radon-progeny equilibrium factor, F. To investigate the relationship between PM2.5 and the radon-progeny equilibrium factor, cigarettes are used to simulate the haze–fog in a multi-functional radon chamber to achieve a stable radon concentration environment. A radon detector and a portable laser aerosol spectrometer are used to obtain the values for C_(mean) PM2.5,C_(Rn), and C_p. The results show that the mean values of F conform with the typical value recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation and are within the reasonable range of0.1–0.9. In this study, a positive correlation is observed between the F values and PM2.5 concentrations.
基金The National Natural Science Foundation of China under contract Nos 42130410,41876075 and U1906210the Fundamental Research Funds for the Central Universities under contract No.201962003.
文摘Radon(Rn)is a naturally occurring radioactive inert gas in nature,and^(222)Rn has been routinely used as a powerful tracer in various aquatic environmental research on timescales of hours to days,such as submarine groundwater discharge.Here we developed a new approach to measure^(222)Rn in discrete water samples with a wide range of^(222)Rn concentrations using a Pulsed Ionization Chamber(PIC)Radon Detector.The sensitivity of the new PIC system is evaluated at 6.06 counts per minute for 1 Bq/L when a 500 mL water sample volume is used.A robust logarithmic correlation between sample volumes,ranging from 250 mL to 5000 mL,and system sensitivity obtained in this study strongly suggests that this approach is suitable for measuring radon concentration levels in various natural waters.Compared to the currently available methods for measuring radon in grab samples,the PIC system is cheaper,easier to operate and does not require extra accessories(e.g.,drying tubes etc.)to maintain stable measurements throughout the counting procedure.