期刊文献+
共找到62篇文章
< 1 2 4 >
每页显示 20 50 100
Seismic performance evaluation of hybrid coupled shear wall system with shear and flexural fuse-type steel coupling beams
1
作者 Zahra Ramezandoust Abbas Tajaddini Panam Zarfam 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第3期691-712,共22页
Replaceable flexural and shear fuse-type coupling beams are used in hybrid coupled shear wall(HCSW)systems,enabling concrete buildings to be promptly recovered after severe earthquakes.This study aimed to analytically... Replaceable flexural and shear fuse-type coupling beams are used in hybrid coupled shear wall(HCSW)systems,enabling concrete buildings to be promptly recovered after severe earthquakes.This study aimed to analytically evaluate the seismic behavior of flexural and shear fuse beams situated in short-,medium-and high-rise RC buildings that have HCSWs.Three building groups hypothetically located in a high seismic hazard zone were studied.A series of 2D nonlinear time history analyses was accomplished in OpenSees,using the ground motion records scaled at the design basis earthquake level.It was found that the effectiveness of fuses in HCSWs depends on various factors such as size and scale of the building,allowable rotation value,inter-story drift ratio,residual drift quantity,energy dissipation value of the fuses,etc.The results show that shear fuses better meet the requirements of rotations and drifts.In contrast,flexural fuses dissipate more energy,but their sectional stiffness should increase to meet other requirements.It was concluded that adoption of proper fuses depends on the overall scale of the building and on how associated factors are considered. 展开更多
关键词 hybrid coupled shear wall steel fuse coupling beam shear and flexural fuse nonlinear dynamic analysis seismic performance
下载PDF
Experimental study on the seismic performance of masonry wall reinforced by cement mortar and polypropylene band
2
作者 Zhao Wenyang Zhou Qiang +3 位作者 Min Quanhuan Yang Lingyu Sun Baitao Song Guquan 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第2期469-479,共11页
Since masonry structures are prone to collapse in earthquakes,a novel joint reinforcement method with a polypropylene band(PP-band)and cement mortar(CM)has been put forward.Compared with the common reinforcement metho... Since masonry structures are prone to collapse in earthquakes,a novel joint reinforcement method with a polypropylene band(PP-band)and cement mortar(CM)has been put forward.Compared with the common reinforcement methods,this method not only facilitates construction but also ensures lower reinforcement cost.To systematically explore the influence of joint reinforcement on the seismic performance of masonry walls,quasi-static tests were carried out on six specimens with different reinforcement forms.The test results show that the joint action of PP-band and CM can significantly improve the specimen′s brittle failure characteristics and enhance the integrity of the specimen after cracking.Compared with the specimen without reinforcement,each of the seismic performance indexes of the joint reinforced specimen had obvious improvement.The maximum increased rate about peak load and ductility of the joint reinforced specimen is 100.6%and 233.4%,respectively. 展开更多
关键词 joint reinforcement masonry structure quasi-static test cement mortar seismic performance
下载PDF
A“Three-index”Seismic Performance Evaluation Method Based on Sino-US Seismic Code
3
作者 Hui Wang Shuqi Wan 《Structural Durability & Health Monitoring》 EI 2018年第3期149-167,共19页
The Code for Seismic Design of Buildings(GB50011-2010)in 2016 and the method of seismic performance-based design for high-rise buildings in the Guide for Performance-based Design of High-Rise Buildings(TBI2017)are com... The Code for Seismic Design of Buildings(GB50011-2010)in 2016 and the method of seismic performance-based design for high-rise buildings in the Guide for Performance-based Design of High-Rise Buildings(TBI2017)are compared.In view of the characteristics and limitations of the seismic performance index set by the Sino-US seismic code,a“three-index”performance index system and evaluation process considering the displacement angle of the structural interlayer,the plastic damage degree of components and the plastic strain of material is put forward;combining the example of time-history analysis of a out-of-code high-rise building under the rare earthquakes is verified.The results show that the method of seismic performance evaluation by using deformation control index in Sino-US seismic code is relatively simple;however,both are lacking in the setting of specific components and the whole structure level respectively.The"three-index"system can comprehensively and quantitatively evaluate the seismic performance of out-of-code high-rise buildings. 展开更多
关键词 seismic performance evaluation seismic performance index out-of-code high-rise buildings rare earthquakes time-history analysis
下载PDF
Study of the seismic performance of expansion double spherical seismic isolation bearings for continuous girder bridges 被引量:11
4
作者 Peng, Tianbo Yu, Xuntao +1 位作者 Wang, Zhennan Han, Lei 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第2期163-172,共10页
The development of an expansion double spherical seismic isolation (DSSI) bearing by modifying the fixed DSSI bearing is described in this paper. The expansion DSSI bearing is characterized by its good energy dissipat... The development of an expansion double spherical seismic isolation (DSSI) bearing by modifying the fixed DSSI bearing is described in this paper. The expansion DSSI bearing is characterized by its good energy dissipation and horizontal displacement capacity and has been successfully integrated into the seismic design of several important engineering projects in China. It is envisioned to be used as a substitute for ordinary expansion bearings in continuous girder bridges to distribute the longitudinal earthquake action among all the piers. Its development, configuration and working mechanism are introduced first. The test method and the seismic performance of an expansion DSSI bearing are then briefly described. A theoretical analysis followed by a numerical analysis for an actual four-span continuous girder bridge are provided as an example, and it is concluded that the expansion DSSI bearing can be integrated into the seismic design of continuous girder bridges. 展开更多
关键词 double spherical seismic isolation (DSSI) bearing seismic isolation seismic performance continuous girder bridge
下载PDF
Seismic performance of cable-sliding friction bearing system for isolated bridges 被引量:7
5
作者 Cheung Pakchiu 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第2期173-183,共11页
During past strong earthquakes, highway bridges have sustained severe damage or even collapse due to excessive displacements and/or very large lateral forces. For commonly used isolation bearings with a pure friction ... During past strong earthquakes, highway bridges have sustained severe damage or even collapse due to excessive displacements and/or very large lateral forces. For commonly used isolation bearings with a pure friction sliding surface, seismic forces may be reduced but displacements are often unconstrained. In this paper, an alternative seismic bearing system, called the cable-sliding friction bearing system, is developed by integrating seismic isolation devices with displacement restrainers consisting of cables attached to the upper and lower plates of the bearing. Restoring forces are provided to limit the displacements of the sliding component. Design parameters including the length and stiffness of the cables, friction coefficient, strength of the shear bolt in a fixed-type bearing, and movements under earthquake excitations are discussed. Laboratory testing of a prototype bearing subjected to vertical loads and quasi-static cyclic lateral loads, and corresponding numerical finite element simulation analysis, were carried out. It is shown that the numerical simulation shows good agreement with the experimental force-displacement hysteretic response, indicating the viability of the new bearing system. In addition, practical application of this bearing system to a multi-span bridge in China and its design advantages are discussed. 展开更多
关键词 isolated bridge cable-sliding friction bearing isolation device seismic performance restrained displacement earthquake damage
下载PDF
Seismic performance evaluation of an infilled rocking wall frame structure through quasi-static cyclic testing 被引量:6
6
作者 Pan Peng Wu Shoujun +1 位作者 Wang Haishen Nie Xin 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期371-383,共13页
Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous ... Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous components offer alternatives that may avoid such failures.A novel infilled rocking wall frame system is proposed that takes advantage of continuous component and rocking characteristics.Previous studies have investigated similar systems that combine a reinforced concrete frame and a wall with rocking behavior used.However,a large-scale experimental study of a reinforced concrete frame combined with a rocking wall has not been reported.In this study,a seismic performance evaluation of the newly proposed infilled rocking wall frame structure was conducted through quasi-static cyclic testing.Critical joints were designed and verified.Numerical models were established and calibrated to estimate frame shear forces.The results evaluation demonstrate that an infilled rocking wall frame can effectively avoid soft-story mechanisms.Capacity and initial stiffness are greatly improved and self-centering behavior is achieved with the help of the infilled rocking wall.Drift distribution becomes more uniform with height.Concrete cracks and damage occurs in desired areas.The infilled rocking wall frame offers a promising approach to achieving seismic resilience. 展开更多
关键词 infilled rocking wall frame seismic performance displacement distribution quasi-static cyclic test
下载PDF
Seismic performance of precast bridge columns connected with grouted corrugated-metal duct through biaxial quasi-static experiment and modeling 被引量:4
7
作者 Xia Zhanghua Lin Shangshun +2 位作者 He Yongbo Ge Jiping Sun Jinlei 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第3期747-770,共24页
In this paper,the seismic behaviors of precast bridge columns connected with grouted corrugated-metal duct(GCMD)were investigated through the biaxial quasi-static experiment and numerical simulation.With a geometric s... In this paper,the seismic behaviors of precast bridge columns connected with grouted corrugated-metal duct(GCMD)were investigated through the biaxial quasi-static experiment and numerical simulation.With a geometric scale ratio of 1:5,five specimens were fabricated,including four precast bridge columns connected with GCMD and one cast-in-place(CIP)bridge column.A finite element analysis model was also established by using OpenSees and was then calibrated by using the experimental results for parameter analysis.The results show the biaxial seismic performance of the precast bridge columns connected with GCMD was similar to the CIP bridge columns regarding ultimate bearing capacity and hysteresis energy,and further,that it could meet the design goal of equivalent performance.The seismic performance of the precast bridge columns connected with GCMD deteriorated more significantly under bi-directional load than under uni-directional load.A proper slenderness ratio(e.g.,7.0-10.0)and longitudinal reinforcement ratio could significantly improve the energy dissipation capacity and deformation capacity of the precast bridge columns,while the axial load ratio and concrete strength had little influence on the above properties.The research results could bring insights to the development of the seismic design of precast bridge columns connected with GCMD. 展开更多
关键词 precast bridge column cast-in-place column grouted corrugated-metal duct connection biaxial quasi-static test seismic performance hysteresis energy
下载PDF
Research on seismic performance of shear walls with concrete filled steel tube columns and concealed steel trusses 被引量:3
8
作者 Cao Wanlin Zhang Jianwei +1 位作者 Dong Hongying Wang Min 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第4期535-546,共12页
In order to further improve the seismic performance of RC shear walls, a new composite shear wall with concrete filled steel tube (CFT) columns and concealed steel trusses is proposed. This new shear wall is a doubl... In order to further improve the seismic performance of RC shear walls, a new composite shear wall with concrete filled steel tube (CFT) columns and concealed steel trusses is proposed. This new shear wall is a double composite shear wall; the first composite being the use of three different force systems, CFT, steel truss and shear wall, and the second the use of two different materials, steel and concrete. Three 1/5 scaled experimental specimens: a traditional RC shear wall, a shear wall with CFT columns, and a shear wall with CFT columns and concealed steel trusses, were tested under cyclic loading and the seismic performance indices of the shear walls were comparatively analyzed. Based on the data from these experiments, a thorough elastic-plastic finite element analysis and parametric analysis of the new shear walls were carried out using ABAQUS software. The finite element results of deformation, stress distribution, and the evolution of cracks in each phase were compared with the experimental results and showed good agreement. A mechanical model was also established for calculating the load-carrying capacity of the new composite shear walls. The results show that this new type of shear wall has improved seismic performance over the other two types of shear wails tested. 展开更多
关键词 shear wall concrete filled steel tube (CFT) concealed steel truss seismic performance experimental research
下载PDF
Study of the seismic performance of hybrid A-frame micropile/MSE (mechanically stabilized earth) wall 被引量:2
9
作者 Chen Yumin Zhang Zhichao Liu Hanlong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第2期275-295,共21页
The Hybrid A-Frame Micropile/MSE (mechanically stabilized earth) Wall suitable for mountain roadways is put forward in this study: a pair of vertical and inclined micropiles goes through the backfill region of a hi... The Hybrid A-Frame Micropile/MSE (mechanically stabilized earth) Wall suitable for mountain roadways is put forward in this study: a pair of vertical and inclined micropiles goes through the backfill region of a highway MSE Wall from the road surface and are then anchored into the foundation. The pile cap and grade beam are placed on the pile tops, and then a road barrier is connected to the grade beam by connecting pieces. The MSE wall's global stability, local stability and impact resistance of the road barrier can be enhanced simultaneously by this design. In order to validate the serviceability of the hybrid A-frame micropile/MSE wall and the reliability of the numerical method, scale model tests and a corresponding numerical simulation were conducted. Then, the seismic performance of the MSE walls before and after reinforcement with micropiles was studied comparatively through numerical methods. The results indicate that the hybrid A-frame micropile/ MSE wall can effectively control earthquake-induced deformation, differential settlement at the road surface, bearing pressure on the bottom and acceleration by means of a rigid-soft combination of micropiles and MSE. The accumulated displacement under earthquakes with amplitude of 0.1-0.5 g is reduced by 36.3%-46.5%, and the acceleration amplification factor on the top of the wall is reduced by 13.4%, 15.7% and 19.3% based on 0.1, 0.3 and 0.5 g input earthquake loading, respectively, In addition, the earthquake-induced failure mode of the MSE wall in steep terrain is the sliding of the MSE region along the backslope, while the micropiles effectively control the sliding trend. The maximum earthquake-induced pile bending moment is in the interface between MSE and slope foundation, so it is necessary to strengthen the reinforcement of the pile body in the interface. Hence, it is proven that the hybrid A-frame micropile/MSE wall system has good seismic performance. 展开更多
关键词 MSE wall steep slope MICROPILE reinforcement measure sliding trend seismic performance
下载PDF
Seismic performance analysis and design suggestion for frame buildings with cast-in-place staircases 被引量:2
10
作者 Feng Yuan Wu Xiaobin +2 位作者 Xiong Yaoqing Li Congchun Yang Wen 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第2期209-219,共11页
Many staircases in reinforced concrete (RC) frame structures suffered severe damage during the Wenchuan earthquake. Elastic analyses for 18 RC structure models with and without staircases are conducted and compared ... Many staircases in reinforced concrete (RC) frame structures suffered severe damage during the Wenchuan earthquake. Elastic analyses for 18 RC structure models with and without staircases are conducted and compared to study the influence of the staircase on the stiffness, displacements and internal forces of the structures. To capture the yielding development and damage mechanism of frame structures, elasto-plastic analysis is carried out for one of the 18 models. Based on the features observed in the analyses, a new type of staircase design i.e., isolating them from the master structure to eliminate the effect of K-type struts, is proposed and discussed. It is concluded that the proposed method of staircase isolation is effective and feasible for engineering design, and does not significantly increase the construction cost. 展开更多
关键词 cast-in-place staircases frame structure seismic performance design suggestions
下载PDF
Seismic performance and global ductility of RC frames rehabilitated with retrofi tted joints by CFRP laminates 被引量:1
11
作者 M.Fakharifar M.K. Sharbatdar +3 位作者 Z.Lin A.Dalvand A.Sivandi-Pour G.Chen 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第1期59-73,共15页
This paper presents a new FRP retrofi tting scheme to strengthen local beam-column joints in reinforced concrete(RC) frames.The new retrofi tting scheme was proposed following a preliminary study of four different exi... This paper presents a new FRP retrofi tting scheme to strengthen local beam-column joints in reinforced concrete(RC) frames.The new retrofi tting scheme was proposed following a preliminary study of four different existing retrofi tting schemes.A numerical simulation was conducted to evaluate the effectiveness of FRP-strengthened reinforced concrete frames by bridging behavior of local joints to the whole structure.Local confi nement effects due to varying retrofi tting schemes in the joints were simulated in the frame model.The seismic behavior factor was used to evaluate the seismic performance of the strengthened RC frames.The results demonstrated that the new proposed retrofi tting scheme was robust and promising,and fi nite element analysis appropriately captured the strength and global ductility of the frame due to upgrading of the local joints. 展开更多
关键词 beam-column joints behavior factor RETROFIT FRP dynamic analysis seismic performance
下载PDF
A new bracing system for improvement of seismic performance of steel jacket type offshore platforms with float-over-deck 被引量:1
12
作者 Behrouz Asgarian Hamed Rahman Shokrgozar 《Petroleum Science》 SCIE CAS CSCD 2013年第3期373-384,共12页
In this paper, the seismic response of a newly designed steel jacket offshore platform with a float over deck (FOD) system in the Persian Gulf was investigated through incremental dynamic analysis. Comparison of inc... In this paper, the seismic response of a newly designed steel jacket offshore platform with a float over deck (FOD) system in the Persian Gulf was investigated through incremental dynamic analysis. Comparison of incremental dynamic analysis results for both directions of the platform shows that the lateral strength of the platform in the float over direction is less than its lateral strength in other direction. Dynamic characteristics measurement of a scale model of platform was also performed using forced vibration tests. From experimental measurement of the scaled model, it was observed that dynamic characteristic of the platform is different in the float over direction compared to the other direction. Therefore, a new offshore installed bracing system for the float over direction was proposed for improvement of seismic performance of this type of platform. Finally, the structure with the modified system was assessed using the probabilistic seismic assessment method as well as experimental measurement of its dynamic characteristics. It was observed that the proposed offshore installed bracing system improves the performance of platforms subjected to strong ground motion. 展开更多
关键词 Steel jacket type offshore platform float-over deck mean annual frequency force vibration test seismic performance dynamic characteristics
下载PDF
Study on seismic performance enhancement in bridges based on factorial analysis 被引量:1
13
作者 Abey ET Somasundaran TP Sajith AS 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期181-198,共18页
The seismic performance of bridges depends on the ductile behavior of its column, as the deck and other substructural components except pile foundations are normally designed to be elastic to facilitate bridge retrofi... The seismic performance of bridges depends on the ductile behavior of its column, as the deck and other substructural components except pile foundations are normally designed to be elastic to facilitate bridge retrofitting. Codes such as AASHTO, Caltrans, IRC: 112 etc. give guidelines for the seismic performance enhancement of columns through ductile detailing. In the present study, a methodology for the seismic performance enhancement of bridges is discussed by using a "Parameter-Based Influence Factor" (PIF) developed from factorial analysis. The parameters considered in the factorial analysis are: percentage of longitudinal reinforcement (Pt), compressive strength of concrete (f'c), yield strength of steel (fy), spacing of lateral ties (5) and column height (/4). The influence of each parameter and their combination on the limit states considered is estimated. Pushover analysis is used to evaluate the capacity of columns, considering shear failure criteria. A total of 243 (35 combinations) analysis results are compiled to develop 'PIF' used in the performance enhancement process. The study also encompasses other sub-objectives such as evaluating the discrepancies in using the Importance Factor (/) in designing bridges of varied functional importance; and estimating the aspect ratio and slenderness ratio values of bridge columns for its initial sizing. 展开更多
关键词 bridge retrofitting column capacity factorial analysis performance enhancement seismic performance
下载PDF
Seismic performance of eccentrically-compressed steel pier under multi-directional earthquake loads 被引量:1
14
作者 Luo Wenwei Li Haifeng Cao Bao′an 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第3期771-789,共19页
In this article,the seismic performance of box-shaped steel piers embedded with energy-dissipating shells under a multi-directional seismic load is investigated.A finite element(FE)model was accurately established and... In this article,the seismic performance of box-shaped steel piers embedded with energy-dissipating shells under a multi-directional seismic load is investigated.A finite element(FE)model was accurately established and verified by the quasi-static test results.A parametric analysis of the hysteretic behaviour of a novel box-shaped steel pier under eccentric pressure was carried out on this basis.We discussed the influence of the eccentricity,axial compression ratio,thickness of embedded shell,ratio of slenderness,spacing of transverse stiffening ribs on the embedded shell,and width-to-thickness ratio of wallboard on the anti-seismic performance of a novel box-shaped steel bridge pier.The results revealed that the load carrying capacity and ductility coefficient of the specimen are substantially influenced by the eccentricity,variation in the axial compression ratio,and slenderness ratio.The specimen′s plastic energy dissipation capacity can be effectively improved by increasing the thickness of the embedded shell.The spacing of the transverse stiffening ribs only marginally affects seismic performance.In addition,the width-to-thickness ratio of the wallboard exerts a more considerable influence on the deformability of the square-section specimen.Finally,a formula for calculating the bearing capacity of the novel box-shaped steel piers under cyclic loading is proposed. 展开更多
关键词 multi-directional seismic action eccentric compression box-shaped steel pier seismic performance finite element analysis
下载PDF
Case study of seismic performance assessment of irregular RC buildings: hospital structure of Avezzano(L'Aquila, Italy) 被引量:1
15
作者 Massimiliano Ferraioli 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期141-156,共16页
Most published studies on inelastic earthquake response of non-symmetric buildings are based on simplified inelastic, highly idealized models, while general conclusions regarding the inelastic torsional response of mu... Most published studies on inelastic earthquake response of non-symmetric buildings are based on simplified inelastic, highly idealized models, while general conclusions regarding the inelastic torsional response of multistory building are still lacking. This paper aims to provide a useful contribution in the study of the torsional response of real irregular buildings. To this aim, the manuscript reports the comprehensive study on the seismic vulnerability of an irregular RC building: the hospital building ofAvezzano (L'Aquila Italy). For this multi-story building, which is irregular in both plan and elevation, the application of nonlinear static evaluation procedures is by no means straightforward. The study proposes a nonlinear static procedure based on pushover analysis under the multimodal distribution of lateral loads and a capacity spectrum method. This pushover procedure accounts for mass distribution, higher modes contribution and mode-shapes correlation. Furthermore, due to its non-iterative feature, it avoids problems of non-convergence and multiple solutions of the conventional capacity spectrum method. Applied to a real case study, the procedure is used to investigate, in a 3D plan irregular building, the sensitivity of torsional inelastic response to lateral force distribution, higher modes contribution, accidental eccentricity and controlled point for monitoring the target displacement. 展开更多
关键词 irregular buildings TORSION pushover analysis seismic performance assessment
下载PDF
An Approach for Quantifying the Influence of Seepage Dissolution on Seismic Performance of Concrete Dams 被引量:1
16
作者 Shaowei Wang Cong Xu +3 位作者 Hao Gu Pinghua Zhu Hui Liu Bo Xu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第4期97-117,共21页
Many concrete dams seriously suffer from long-term seepage dissolution,and the induced mechanical property deterioration of concrete may significantly affect the structural performance,especially the seismic safety.An... Many concrete dams seriously suffer from long-term seepage dissolution,and the induced mechanical property deterioration of concrete may significantly affect the structural performance,especially the seismic safety.An approach is presented in this paper to quantify the influence of seepage dissolution on seismic performance of concrete dams.To connect laboratory test with numerical simulation,dissolution tests are conducted for concrete specimens and using the cumulative relative leached calcium as an aging index,a deterioration model is established to predict the mechanical property of leached concrete in the first step.A coupled seepage-calcium dissolutionmigrationmodel containing two calculation modes is proposed to simulate the spatially non-uniformdeterioration of concrete dams.Based on the simulated state of a roller compacted concrete dam subjected to 100 years of seepage dissolution,seismic responses of the damare subsequently analyzed.During which the nonlinear cracking of concrete,the radiation damping of the far-field foundation is considered.Research results show that seepage dissolution will seriously weaken the seismic safety of concrete dams because of the dissolution-induced decrease of effective thickness of the dam body.The upstream surface,dam toe and gallery wall suffer from a large degree of dissolution,whereas it is minimal and basically the same inside the dam body,at a degree of 0.19%within 100 years.The horizontal displacements of dam crest under the design static load and fortification against earthquake increase by 6.9%and 21.9%,respectively,and the dissolution-induced seismic cracking leads to the failure of dam anti-seepage system.This study can provide engineers with a reference basis for reinforcement decision of old concrete dams. 展开更多
关键词 Concrete dams seepage dissolution deterioration prediction model seismic performance failure mode
下载PDF
Comparison between the Seismic Performance of Buried Pipes and Pipes in a Utility Tunnel 被引量:1
17
作者 Wei Liu Qianxiang Wu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第5期661-690,共30页
A utility tunnel system consists of pipes and ancillary facilities.In this paper,a finite element model of a concrete utility tunnel with pipes inside is established.Several tunnel segments were built to simulate a re... A utility tunnel system consists of pipes and ancillary facilities.In this paper,a finite element model of a concrete utility tunnel with pipes inside is established.Several tunnel segments were built to simulate a real utility tunnel,while the pipe was fixed by springs on the brackets in the utility tunnel.Using the discrete soil spring element to simulate the soil-structure interaction,actual earthquake records were adopted as excitation to analyze the seismic responses of pipes in a utility tunnel.Moreover,the influences of different parameters,including soil type,earthquake records,and field apparent wave velocity on the seismic responses of the utility tunnel and the pipes inside were studied.Finally,the seismic responses of buried pipes were analyzed and compared with those of pipes in a utility tunnel to evaluate the seismic performance of pipes for two working conditions. 展开更多
关键词 Pipe in utility tunnel buried pipe seismic performance
下载PDF
Seismic Performance of Assembled Shear Wall with Defective Sleeve Connection
18
作者 Hua Yan Bo Song +1 位作者 Dongsheng Xu Guodong Zhang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第4期199-217,共19页
In this paper,three kinds of shear walls with full sleeve grouting,fully defective sleeve and partially defective are designed for finite element analysis to analyze the influence of defects on the seismic performance... In this paper,three kinds of shear walls with full sleeve grouting,fully defective sleeve and partially defective are designed for finite element analysis to analyze the influence of defects on the seismic performance of shear walls.The research shows that at the beginning of loading(5 s),the three models begin to appear compressive damage at the bottom of the wall in all three models.The damage of the defect-free model develops rapidly,and the damage of the fully defective model is basically the same as that of the partially defective model.With the gradual increase of displacement control(15 s),the compressive damages at the foot of the wall in the defect-free and partially defective grouting model are obvious,with plastic hinge formed in the foot of the wall,and the phenomenon of development along the pier body showing up.When the structure is damaged,the overall compressive damages of the wall in the defect-free and partially defective models are obvious,and the damage on the defective side of the partially defective model is slightly deficient.While the maximum stress of pre-stressed reinforcement in the defect-freemodel is concentrated at the top of the sleeve,themaximumstress of the pre-stressed steel bar in the fully defective model appears at the end of the steel bar in the sleeve.The hysteresis curve shape of the non-defectmodel and partially defective model are basically the same,showing a“shuttle”shape with a sound energy dissipation effect.The hysteresis curve shape of the fully defective model appears an obvious“pinch”phenomenon.The yield displacement levels of the defect-free and partially defective models are smaller than that of the fully defective model structure.The stiffness degradation curves of the three models basically overlap with one another.Before the limit displacement,the stiffness results of the non-defect model and the partially defective model are greater than that of the fully defective model.When the displacement is loaded to 20 mm,the stiffness degradation of the three models is equivalent. 展开更多
关键词 Grouting sleeve DEFECTS shear wall finite element analysis seismic performance
下载PDF
Experimental study on the seismic performance of new sandwich masonry walls
19
作者 Xiao Jianzhuang Pu Jie Hu Yongzhong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第1期77-86,共10页
Sandwich masonry walls are widely used as energy-saving panels since the interlayer between the outer leaves can act as an insulation layer.New types of sandwich walls are continually being introduced in research and ... Sandwich masonry walls are widely used as energy-saving panels since the interlayer between the outer leaves can act as an insulation layer.New types of sandwich walls are continually being introduced in research and applications,and due to their unique bond patterns,experimental studies have been performed to investigate their mechanical properties,especially with regard to their seismic performance.In this study,three new types of sandwich masonry wall have been designed,and cyclic lateral loading tests were carried out on five specimens.The results showed that the specimens failed mainly due to slippage along the bottom cracks or the development of diagonal cracks,and the failure patterns were considerably influenced by the aspect ratio.Analysis was undertaken on the seismic response of the new walls,which included ductility,stiffness degradation and energy dissipation capacity,and no obvious difference was observed between the seismic performance of the new walls and traditional walls.Comparisons were made between the experimental results and the calculated results of the shear capacity.It is concluded that the formulas in the two Chinese codes(GB 50011 and GB 50003) are suitable for the calculation of the shear capacity for the new types of walls,and the formula in GB 50011 tends to be more conservative. 展开更多
关键词 sandwich wall seismic performance shear behavior cyclic loading test
下载PDF
Seismic performance evaluation of VCFPB isolated storage tank using real-time hybrid simulation
20
作者 Hong Yue Tang Zhenyun +1 位作者 Li Zhenbao Du Xiuli 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第2期501-515,共15页
Variable curvature friction pendulum bearings(VCFPB)effectively reduce the dynamic response of storage tanks induced by earthquakes.Shaking table testing is used to assess the seismic performance of VCFPB isolated sto... Variable curvature friction pendulum bearings(VCFPB)effectively reduce the dynamic response of storage tanks induced by earthquakes.Shaking table testing is used to assess the seismic performance of VCFPB isolated storage tanks.However,the vertical pressure and friction coefficient of the scaled VCFPB in the shaking table tests cannot match the equivalent values of these parameters in the prototype.To avoid this drawback,a real-time hybrid simulation(RTHS)test was developed.Using RTHS testing,a 1/8 scaled tank isolated by VCFPB was tested.The experimental results showed that the displacement dynamic magnification factor of VCFPB,peak reduction factors of the acceleration,shear force,and overturning moment at bottom of the tank,were negative exponential functions of the ratio of peak ground acceleration(PGA)and friction coefficient.The peak reduction factors of displacement,acceleration,force and overturning moment,which were obtained from the experimental results,are compared with those calculated by the Housner model.It can be concluded that the Housner model is applicable in estimation of the acceleration,shear force,and overturning moment of liquid storage tank,but not for the sliding displacement of VCFPBs. 展开更多
关键词 liquid storage tank base isolation variable curvature friction pendulum bearing seismic performance real-time hybrid simulation test
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部