期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Electron Microscopic Studies on the Silver-stained Nucleolar Cycle of Physarum polycephalum 被引量:1
1
作者 曾宪录 焦明大 +2 位作者 王晓光 宋朝霞 郝水 《Acta Botanica Sinica》 CSCD 2001年第7期680-685,共6页
The dynamic changes of nucleolar ultrastructure in the cell cycle of Physarum polycephalum Schw. were studied by an en bloc silver-staining method. The results showed that the nucleolus was large in size and situated ... The dynamic changes of nucleolar ultrastructure in the cell cycle of Physarum polycephalum Schw. were studied by an en bloc silver-staining method. The results showed that the nucleolus was large in size and situated in the center of the nucleus in late G(2)-phase, and the fibrillar centers, dense fibrillar components and granular components could be observed in the nucleolus. During prophase, the nucleolus moved towards the periphery of the nucleus and in late prophase disintegrated near the nuclear envelope. in metaphase, the disintegrated nucleolar components were dispersed in masses and located at the periphery of the chromosomal region of the nucleus. No specifically silver-stained area and argentophilic protein sheath were observed on the chromosomes, but there were some big dispersed silver particles within the chromosomes. During telophase the nucleolar components moved towards the two poles along with the chromosomes and co-existed with the decondensing chromatin in daughter nuclei. The nucleolar components then gradually converged with one another and separated from the chromatin. A big nucleolus was formed in the nucleus about 120 min after the completion of mitosis. 展开更多
关键词 Physarum polycephalum silver-stained nucleolus ultrastructural changes
下载PDF
Ultrasensitive electrochemical immunosensor of carcinoembryonic antigen based on gold-label silver-stain signal amplification
2
作者 Gaojian Yang Yuxuan Lai +2 位作者 Ziqi Xiao Congli Tang Yan Deng 《Chinese Chemical Letters》 SCIE CAS CSCD 2018年第12期1857-1860,共4页
A novel gold-label silver-stain electrochemical immunosensor was developed based on polythioninegold nanoparticles(PTh-Au) modified glassy carbon electrode(GCE) as a platform and secondary antibody labeled Au NPs... A novel gold-label silver-stain electrochemical immunosensor was developed based on polythioninegold nanoparticles(PTh-Au) modified glassy carbon electrode(GCE) as a platform and secondary antibody labeled Au NPs(Ab;-Au) as immumoprobe for carcinoembryonic antigen(CEA) detection. The sandwich-type biosensor adopted anodic stripping voltammetry to detect silver stripping signal when the Ab;-Au of the formed immunocomplexes were stained with silver. The optimized detection conditions were investigated. The effect of different electrochemical responses at various concentrations of CEA was checked by anodic stripping voltammetry. This immunosensor showed a low detection limit of 0.055 ng/mL and a wide linear calibration of 0.1-120 ng/mL(R;=0.99856). Moreover, this immunoassay also existed the advantages of good reproducibility, stability and selectivity. Thus, this immunosensing protocol may provide a potential application for effective clinical detection of CEA. 展开更多
关键词 Gold-label silver-stain Carcinoembryonic antigen Sandwich-type immunoassay Electrochemical immunosensor Anodic stripping voltammetry
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部