A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas...A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.展开更多
A new pre-column derivation HPLC method with solid-phase extraction to determine captopril in human plasma was established. Derivation products were extracted by a solid-phase extraction method after the reagent, p-a-...A new pre-column derivation HPLC method with solid-phase extraction to determine captopril in human plasma was established. Derivation products were extracted by a solid-phase extraction method after the reagent, p-a-dibromoacetophenone(p-BPB), was added in the plasma samples. The samples were analyzed in a VP-ODS column with UV-detector. The calibration curve of captopril was linear within the range of 5~1000 ngmL-1 with r=0.9987, the recovery of this method was 98.652.04%, within day and between day RSD were no more than 3.4% and 8.4% respectively. To study the pharmacokinetics and the relative bioavailability of captopril tablets, two formulations of captopril tablets were given to 18 healthy male volunteers according to a randomized 2-way cross-over design with a 1-week washout period. The respective AUC0~6 , Cmax and Tmax values of the two formulations were 424.5125.7 and 439.4113.3 mghL-1; 505.9244.6 and 504.8172.2 mgL-1; 0.6620.181 and 0.5280.176 h. Results from statistics analysis showed that there were no significant difference between the AUC0~6 , Cmax and Tmax values of the two formulations, The relative bioavailability of tablets I with respect to II was 96.114.6% from AUC0~6 measurement. Bioequivalance was observed between the two tablets.展开更多
A rapid and simple preconcentration step applying packed-fiber solid-phase extraction columns has been investigated to vitamin B12. The extraction performance of the new method was investigated preliminarily on vitami...A rapid and simple preconcentration step applying packed-fiber solid-phase extraction columns has been investigated to vitamin B12. The extraction performance of the new method was investigated preliminarily on vitamin functional drink. The analysis used a reversed-phase C18 column, with a photo-diode array detector at 220 nm. The samples were preconcentrated with packed-fiber solid-phase extraction columns. Good linearity was observed in vitamin functional drink. The repeatability of extraction performance, expressed as relative standard deviations, was from 3.5% to 4.3%. The limit of detection (LOD) is 5 ng mL^-1 (S/N = 3). Finally, the method had been applied for the determination of vitamin B12 in vitamin functional drink.展开更多
A fast analytical method for the simultaneous determination of 9 mycotoxins, including alfatoxins (B1, B2, G1, and G2), fumonisins (B1, B2 and B3), zearalenone, and deoxynivalenol in corn using dispersive solid-ph...A fast analytical method for the simultaneous determination of 9 mycotoxins, including alfatoxins (B1, B2, G1, and G2), fumonisins (B1, B2 and B3), zearalenone, and deoxynivalenol in corn using dispersive solid-phase extraction method and ultra-performance liquid chromatography coupled to tandem quadrupole time-of-lfight mass spectrometry (UPLC-Q-TOF-MS) was developed and validated. Samples were extracted with acetonitrile-water (84:16, v:v, containing 1% acetic acid) using ultrasonic extraction. The extracts were puriifed with a dispersive SPE method using C18 as a cleaning agent. The ifnal clear extracts were dried by nitrogen blowing and subsequently redissolved in methanol-water (5:5, v:v). The samples were then analyzed by UPLC-Q-TOF-MS with 0.1% formic acid in ammonium acetate-methanol as mobile phase. The mean recoveries were ranged from 68.0 to 120.0%, and the relative standard deviation (RSD) ranged from 0.18 to 6.29%. Limits of detections ranged from 0.05 to 50 μg kg?1, and limits of quantiifcation ranged from 0.1 to 200 μg kg?1, which were below the legal limits set by the European Union for the legislated mycotoxins. The developed method was applied to 130 corn samples. Among the mycotoxins studied, alfatoxins B1 and fumonisins B1, B2 and B3 were the most predominant mycotoxins, and their concentrations were 0–593.12, 0–2.01×104, 0–6.94×103 and 0–3.05×103 μg kg–1, respectively.展开更多
A method for the simultaneous separation and determination of organic acids and inorganic anions in Bayer liquors was developed by gradient ion chromatography with suppressed conductivity detection. Formate, acetate, ...A method for the simultaneous separation and determination of organic acids and inorganic anions in Bayer liquors was developed by gradient ion chromatography with suppressed conductivity detection. Formate, acetate, propionate, oxalate, succinate, glutarate, fluoride, chloride and sulfate were separated and determined in 33 min. The samples were pretreated with solid-phase extraction, which has high selectivity for removing a large number of metallic ions in the Bayer liquors, and filtered with a 0.45 μm filter membrane before being injected into the ion chromatographic system. The separation of six organic acids and three inorganic anions was achieved on an IonPac AS11-HC column with KOH as the eluent, and the detection was performed by a conductivity detection mode. No interference is found in the presence of fluorate, chlorate and sulphate when organic acids are determined. The calibration graphs of peak area for all the analytes are linear over a wide range. The relative standard derivation of the peak area of analytes is less than 2.14%. Under optimum conditions the detection ranges from 0.2 to 100.0 mg/L. The average recoveries of the added standards are between 94.3% and 102.8%.展开更多
The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ...The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in microemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(Ⅲ) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10^-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(Ⅲ) ions. The method has been applied to the determination of trace gold with satisfactory results.展开更多
Enrichment of trace bioactive constituents and metabolites from complex biological samples is challenging.This study presented a one-pot synthesis of magnetic polydopamine nanoparticles(Fe3O4@-SiO2@PDA NPs)with multip...Enrichment of trace bioactive constituents and metabolites from complex biological samples is challenging.This study presented a one-pot synthesis of magnetic polydopamine nanoparticles(Fe3O4@-SiO2@PDA NPs)with multiple recognition sites for the magnetic dispersive solid-phase extraction(MDSPE)of ginsenosides from rat plasma treated with white ginseng.The extracted ginsenosides were characterized by combining an ultra-high-performance liquid chromatography coupled to a highresolution mass spectrometry with supplemental UNIFI libraries.Response surface methodology was statistically used to optimize the extraction procedure of the ginsenosides.The reusability of Fe3O4@-SiO2@PDA NPs was also examined and the results showed that the recovery rate exceeded 80%after recycling 6 times.Furthermore,the proposed method showed greater enrichment efficiency and could rapidly determine and characterize 23 ginsenoside prototypes and metabolites from plasma.In comparison,conventional methanol method can only detect 8 ginsenosides from the same plasma samples.The proposed approach can provide methodological reference for the trace determination and characterization of different bioactive ingredients and metabolites of traditional Chinese medicines and food.展开更多
A new analytical procedure based on solid-phase extraction method coupled to GC-FID has been developed and validated for the determination of five phthalate esters (PAEs) (dimethyl-(DMP), diethyl-(DEP), di-n-bu...A new analytical procedure based on solid-phase extraction method coupled to GC-FID has been developed and validated for the determination of five phthalate esters (PAEs) (dimethyl-(DMP), diethyl-(DEP), di-n-butyl-(DBP), di-2-ethylhexyl- (DEHP), di-n-octyl-(DOP)) in fish samples. There was a good linear relationship in the range of 0.05-10μg with the detection limits of 0.09-0.16ng .The recoveries obtained for PAEs ranged from 88.6% to 96.4%with RSD of 4.2%-10.2%.The applicability of the developed method was demonstrated for real fish samples.展开更多
[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From...[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From the aspects of solid-phase extraction column,elution solvent,elution volume,elution speed and so forth,the test conditions of SPE-HPLC method were optimized,and trace amount of PAHs in urban sewage was determined.[Result] The optimized solid-phase extraction conditions were SUPELCLEAN LC-18 solid-phase extraction column,methylene dichloride as elution solvent,15 ml elution volume,2 ml/min elution speed,5 ml/min loading speed,1 000 ml water with 200 ml methanol loading volume.Under the optimized extraction conditions,the recovery was high,namely 76.3%-105.2%;relative standard deviation was 3.8%-6.0%,showing good precision;detection limit was low,only 0.000 8-0.048 0 μg/L.[Conclusion] This method is user-friendly,with high sensitivity and good precision,and suitable for continuous determination of a large volume of water samples.展开更多
Aim An HPLC method for analyzing eleutheroside B (ELU B) and eleutheroside E(ELU E) , two of the main active substances of Acanthopanax preparations were studied. Methods Thesamples were analyzed on a kromasil ODS col...Aim An HPLC method for analyzing eleutheroside B (ELU B) and eleutheroside E(ELU E) , two of the main active substances of Acanthopanax preparations were studied. Methods Thesamples were analyzed on a kromasil ODS column with water-acetonitrile as a gradient mobile phase.The flow rate was 0.8 mL·min^(-1) and detecting wavelengths were 206 nm for ELU B, 220 nm for ELUE, solid phase extraction (SPE) and internal standard-salicin were selected. Results The recoveriesof Acanthopanax tablets and injection were 90.4% - 96.8% and 96.4% - 99.8% for ELU B, 87.7% -93.3%and 95.7% - 98.5% for ELU E, respectively. The linear ranges were 4.45 - 22.25 μg· mL^(-1) (r =0.999 8) and 5.11 - 25.55 μg·mL^(-1) ( r = 0.999 7) respectively. Conclusion This method can savethe time for cleaning the chromatographic system and improve sensitivity for Acanthopanaxpreparations , thus providing a way to evaluate the quality of Acanthopanax preparations.展开更多
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog...An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.展开更多
Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tr...Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tra- ditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as mor- phine-positive samples by a strip test, 'were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories.展开更多
In this paper, a method was established to determine the boiling point distribution of hydrocarbon types in diesel. The diesel sample was separated into the saturate and aromatic fractions by means of solid-phase extr...In this paper, a method was established to determine the boiling point distribution of hydrocarbon types in diesel. The diesel sample was separated into the saturate and aromatic fractions by means of solid-phase extraction (SPE), and each fraction was analyzed by GC/FID-EIMS. According to the relationship between boiling point and retention time of n-paraffins in the chromatogram, the percentages of saturates and aromatics at each temperature interval were calculated. According to the average mass spectra of the saturate and aromatic fractions at each temperature interval, the hydrocarbon types of the sample were identified through summation of characteristic mass fragments. Using this method, the changes in composition of diesel during hydrotreating process were studied. The results showed that hydrogenation of aromatics is the main reaction during the hydrotreating process. The more rings the aromatics have, the easier the hydrogenation reactions would take place. The aromatics were converted into cycloparaffins via the hydrogenation and saturation process, leading to an increase in low boiling point fractions in the hydrotreated oil.展开更多
[ Objective] The research aimed to develop a new molecular imprinting solid-phase extraction column for the separation and enrichment of melamine in feed. [ Method] The molecular imprinting polymer of melamine was pre...[ Objective] The research aimed to develop a new molecular imprinting solid-phase extraction column for the separation and enrichment of melamine in feed. [ Method] The molecular imprinting polymer of melamine was prepared by mass polymerization method. This polymer was used as filler to prepare molecular imprinting polymer solid-phase extraction(MIP-SPE) column of melamine. The solid-phase extraction conditions were optimized and melamine content in concentrated solution was determined by using HPLC. [ Result] Melamine eould be separated selectively from feed and enriehed by self-made MIP-SPE column. It could wipe off complex matrix from feed and the addition recovery rate was 95%. The contrast experiment between MIP-SPE column and NMIP-SPE ( non-imprinted polymer- solid phase extraction) column showed that the extraction efficiency of the former was obviously higher than the latter. [ Conclusion] The home-made MIP- SPE column could be used to separate and enrich melamine in feed efficiently, with a broad application prospect.展开更多
A rapid, cost effective and reliable analytical method was developed and validated for the simultaneous determination of four estrogens (17 β-estradiol, 17 α-ethinylestradiol, estrone, and estriol) in compost sample...A rapid, cost effective and reliable analytical method was developed and validated for the simultaneous determination of four estrogens (17 β-estradiol, 17 α-ethinylestradiol, estrone, and estriol) in compost samples from the biodegradation of biological infectious hazardous wastes. Ultrasonic solvent extraction, using methanol as extraction solvent, coupled with SPE clean-up, using cartridges HLB 60 mg - 6 ml Supelco®<sup></sup> and acetonitrile for reconstitution of eluents, was used for the simultaneous extraction of the four estrogens. Mean recoveries in the range of 98% - 107% were obtained. All compounds were separated in a single gradient run by UHPLC Kinetex<sup>TM</sup> 2.6 μm XB-C18 100 ÅLC (50 × 4.6 mm) column. Analytes were detected via multiple reaction monitoring (MRM) using an AB SCIEX API-5000TM triple quadrupole (Applied Biosystems/MDS SCIEX) with electrospray ionization in negative mode. Isocratic mobile phase of Water:ACN (50:50) resulted to be the optimum. Limits of detection and quantification were on the order of 0.66 ng·g<sup>-1</sup> and 2 ng·g<sup>-1</sup> for all the estrogens. These limits were lower than most of the values reported in the literature for similar matrices. Suitable level of linearity, good repeatability and reproducibility with coefficients of variation is lower than 11.7%, 6.8% and 8.3%, respectively.展开更多
It is important to understand the adsorption mechanism of chemicals and active pharmaceu-tical ingredients (API) on sewage sludge since wastewater treatment plants are the last barrier before the release of these co...It is important to understand the adsorption mechanism of chemicals and active pharmaceu-tical ingredients (API) on sewage sludge since wastewater treatment plants are the last barrier before the release of these compounds to the environment. Adsorption models were developed considering mostly hydrophobic API-sludge interaction. They have poor predictive ability, especially with ionisable compounds. This work proposes a solid-phase extraction (SPE) approach to estimate rapidly the API-sludge interaction. Sludge-filled SPE cartridges could not be percolated with API spiked mobile phases so different powders were tested as SPE sludge supports. Polytetrafluoroethylene (PTFE) was selected and tested at different PTFE/sludge ratios under eight different adsorption conditions with three API ionisable compounds. The PTFE/sludge mixtures with 50% or less sludge could be used in SPE mode for API sorption studies with methanol/water liquid phases. The results gave insights into API-sludge interactions. It was found that π-π, hydrogen-bonding and charge-charge interactions were as important as hydrophobicity in the adsorption mechanism of charged APIs on sludge.展开更多
A molecularly imprinted polymer (MIP), prepared around a cotinine template, has been synthesized. The feasibility of using the polymer for solid-phase extraction (SPE) of cotinine from biological samples has been ...A molecularly imprinted polymer (MIP), prepared around a cotinine template, has been synthesized. The feasibility of using the polymer for solid-phase extraction (SPE) of cotinine from biological samples has been investigated. The results show that cotinine can be quantitatively retained and eluted from the polymer. Experiments with human urine samples indicate that clean target analyte is obtained for HPLC with UV detection using the protocol.展开更多
Capillary electrochromatography (CEC) is a hybrid technique that couples the good selectivity of high-performance liquid chromatography (HPLC) and the high separation efficiency of capillary electrophoresis (CE)...Capillary electrochromatography (CEC) is a hybrid technique that couples the good selectivity of high-performance liquid chromatography (HPLC) and the high separation efficiency of capillary electrophoresis (CE). Both charged and uncharged compounds can be separated effectively using CEC. In some cases, however, the bubbles that generated in the capillary column in pure CEC performed on commercial CE instruments will cause unstable current and even disrupt the separation when the concentration of buffer is very high. By applying pressure on the electrochromatographic separation via a micro-HPLC pump, pressurized capillary electrochromatography ( pCEC ) combines two driving factors of the electroosmotic flow (EOF) and the pressure flow, thereby increasing the speed and the selectivity of separation and suppressing the bubble formation. Moreover,展开更多
For purpose of purification and enrichment, environmental samples usually need to be pretreated before analysis because of low concentration of residual organic matters. Solid-phase extraction (SPE) is one of the fr...For purpose of purification and enrichment, environmental samples usually need to be pretreated before analysis because of low concentration of residual organic matters. Solid-phase extraction (SPE) is one of the frequently used methods of pretreatment. This article introduces the methodological principle and flow channel of SPE as well as the categories of frequently used small extraction column, analyzes the application of online SPE technology in environmental analysis, generalizes the advantages of online SPE and sets forth its developmental trend.展开更多
A new multi-residue method based on solid-phase extraction (SPE) with centrifugation was developed for determination and quantitation of 67 pesticides in water samples. Two SPE cartridges were tested: Chromabond C18 a...A new multi-residue method based on solid-phase extraction (SPE) with centrifugation was developed for determination and quantitation of 67 pesticides in water samples. Two SPE cartridges were tested: Chromabond C18 and Oasis HLB. Parameters that influence the extraction efficiency such as the eluent volume, the sample loading volume, the addition of organic solvent to water sample, sorbent drying and elute concentration were optimized. The innovation of this work was the examination of the use of a centrifugation technique in both the drying and elution steps. When combined with centrifugation, the volume of the elution solvent was reduced to 2 mL and the time for sorbent drying decreased also to 10 min under vacuum. Under the optimized conditions, this method showed good recoveries higher than 65% - 68% for the 67 analyzed pesticides using the C18 and HLB cartridges with relative standard deviations lower than 9.7% - 12.3%. Limits of quantification were between 2 and 20 ng.L–1. The simplicity of the described method, use of less of organic solvent, short procedure time, and good recoveries demonstrate the advantages of this environmentally friendly approach for routine analysis of numerous samples.展开更多
基金The National Basic Research Program of China(973Program)(No.2012CB933302)the National Instrumental Research Program(No.2014YQ06077303)+1 种基金the National Natural Science Foundation of China(No.81172720,21307086)Suzhou Science and Technology Department Foundation(No.ZXG201441)
文摘A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.
文摘A new pre-column derivation HPLC method with solid-phase extraction to determine captopril in human plasma was established. Derivation products were extracted by a solid-phase extraction method after the reagent, p-a-dibromoacetophenone(p-BPB), was added in the plasma samples. The samples were analyzed in a VP-ODS column with UV-detector. The calibration curve of captopril was linear within the range of 5~1000 ngmL-1 with r=0.9987, the recovery of this method was 98.652.04%, within day and between day RSD were no more than 3.4% and 8.4% respectively. To study the pharmacokinetics and the relative bioavailability of captopril tablets, two formulations of captopril tablets were given to 18 healthy male volunteers according to a randomized 2-way cross-over design with a 1-week washout period. The respective AUC0~6 , Cmax and Tmax values of the two formulations were 424.5125.7 and 439.4113.3 mghL-1; 505.9244.6 and 504.8172.2 mgL-1; 0.6620.181 and 0.5280.176 h. Results from statistics analysis showed that there were no significant difference between the AUC0~6 , Cmax and Tmax values of the two formulations, The relative bioavailability of tablets I with respect to II was 96.114.6% from AUC0~6 measurement. Bioequivalance was observed between the two tablets.
基金supported by Jiangsu Science and Technology Department(No.BG2007044)Jiangsu Preventive Medicine Foundation(No.Y2006025).
文摘A rapid and simple preconcentration step applying packed-fiber solid-phase extraction columns has been investigated to vitamin B12. The extraction performance of the new method was investigated preliminarily on vitamin functional drink. The analysis used a reversed-phase C18 column, with a photo-diode array detector at 220 nm. The samples were preconcentrated with packed-fiber solid-phase extraction columns. Good linearity was observed in vitamin functional drink. The repeatability of extraction performance, expressed as relative standard deviations, was from 3.5% to 4.3%. The limit of detection (LOD) is 5 ng mL^-1 (S/N = 3). Finally, the method had been applied for the determination of vitamin B12 in vitamin functional drink.
基金supported by the Key Project of Science and Technology Development Program of Shandong Province,China(2013KF03)
文摘A fast analytical method for the simultaneous determination of 9 mycotoxins, including alfatoxins (B1, B2, G1, and G2), fumonisins (B1, B2 and B3), zearalenone, and deoxynivalenol in corn using dispersive solid-phase extraction method and ultra-performance liquid chromatography coupled to tandem quadrupole time-of-lfight mass spectrometry (UPLC-Q-TOF-MS) was developed and validated. Samples were extracted with acetonitrile-water (84:16, v:v, containing 1% acetic acid) using ultrasonic extraction. The extracts were puriifed with a dispersive SPE method using C18 as a cleaning agent. The ifnal clear extracts were dried by nitrogen blowing and subsequently redissolved in methanol-water (5:5, v:v). The samples were then analyzed by UPLC-Q-TOF-MS with 0.1% formic acid in ammonium acetate-methanol as mobile phase. The mean recoveries were ranged from 68.0 to 120.0%, and the relative standard deviation (RSD) ranged from 0.18 to 6.29%. Limits of detections ranged from 0.05 to 50 μg kg?1, and limits of quantiifcation ranged from 0.1 to 200 μg kg?1, which were below the legal limits set by the European Union for the legislated mycotoxins. The developed method was applied to 130 corn samples. Among the mycotoxins studied, alfatoxins B1 and fumonisins B1, B2 and B3 were the most predominant mycotoxins, and their concentrations were 0–593.12, 0–2.01×104, 0–6.94×103 and 0–3.05×103 μg kg–1, respectively.
基金Project(2005CB623702) supported by the National Key Basic Research Program of China
文摘A method for the simultaneous separation and determination of organic acids and inorganic anions in Bayer liquors was developed by gradient ion chromatography with suppressed conductivity detection. Formate, acetate, propionate, oxalate, succinate, glutarate, fluoride, chloride and sulfate were separated and determined in 33 min. The samples were pretreated with solid-phase extraction, which has high selectivity for removing a large number of metallic ions in the Bayer liquors, and filtered with a 0.45 μm filter membrane before being injected into the ion chromatographic system. The separation of six organic acids and three inorganic anions was achieved on an IonPac AS11-HC column with KOH as the eluent, and the detection was performed by a conductivity detection mode. No interference is found in the presence of fluorate, chlorate and sulphate when organic acids are determined. The calibration graphs of peak area for all the analytes are linear over a wide range. The relative standard derivation of the peak area of analytes is less than 2.14%. Under optimum conditions the detection ranges from 0.2 to 100.0 mg/L. The average recoveries of the added standards are between 94.3% and 102.8%.
文摘The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in microemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(Ⅲ) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10^-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(Ⅲ) ions. The method has been applied to the determination of trace gold with satisfactory results.
基金This work was supported by grants from the National Natural Science Foundation of China Key Program(NO.81530094)General Program(NO.81573574,81873193)the Science and Technology Development Project of Jilin Province(20190201283JC).
文摘Enrichment of trace bioactive constituents and metabolites from complex biological samples is challenging.This study presented a one-pot synthesis of magnetic polydopamine nanoparticles(Fe3O4@-SiO2@PDA NPs)with multiple recognition sites for the magnetic dispersive solid-phase extraction(MDSPE)of ginsenosides from rat plasma treated with white ginseng.The extracted ginsenosides were characterized by combining an ultra-high-performance liquid chromatography coupled to a highresolution mass spectrometry with supplemental UNIFI libraries.Response surface methodology was statistically used to optimize the extraction procedure of the ginsenosides.The reusability of Fe3O4@-SiO2@PDA NPs was also examined and the results showed that the recovery rate exceeded 80%after recycling 6 times.Furthermore,the proposed method showed greater enrichment efficiency and could rapidly determine and characterize 23 ginsenoside prototypes and metabolites from plasma.In comparison,conventional methanol method can only detect 8 ginsenosides from the same plasma samples.The proposed approach can provide methodological reference for the trace determination and characterization of different bioactive ingredients and metabolites of traditional Chinese medicines and food.
文摘A new analytical procedure based on solid-phase extraction method coupled to GC-FID has been developed and validated for the determination of five phthalate esters (PAEs) (dimethyl-(DMP), diethyl-(DEP), di-n-butyl-(DBP), di-2-ethylhexyl- (DEHP), di-n-octyl-(DOP)) in fish samples. There was a good linear relationship in the range of 0.05-10μg with the detection limits of 0.09-0.16ng .The recoveries obtained for PAEs ranged from 88.6% to 96.4%with RSD of 4.2%-10.2%.The applicability of the developed method was demonstrated for real fish samples.
基金Supported by National Science and Technology Key Project of Water Pollution Control and Management (2012ZX07209-003)
文摘[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From the aspects of solid-phase extraction column,elution solvent,elution volume,elution speed and so forth,the test conditions of SPE-HPLC method were optimized,and trace amount of PAHs in urban sewage was determined.[Result] The optimized solid-phase extraction conditions were SUPELCLEAN LC-18 solid-phase extraction column,methylene dichloride as elution solvent,15 ml elution volume,2 ml/min elution speed,5 ml/min loading speed,1 000 ml water with 200 ml methanol loading volume.Under the optimized extraction conditions,the recovery was high,namely 76.3%-105.2%;relative standard deviation was 3.8%-6.0%,showing good precision;detection limit was low,only 0.000 8-0.048 0 μg/L.[Conclusion] This method is user-friendly,with high sensitivity and good precision,and suitable for continuous determination of a large volume of water samples.
文摘Aim An HPLC method for analyzing eleutheroside B (ELU B) and eleutheroside E(ELU E) , two of the main active substances of Acanthopanax preparations were studied. Methods Thesamples were analyzed on a kromasil ODS column with water-acetonitrile as a gradient mobile phase.The flow rate was 0.8 mL·min^(-1) and detecting wavelengths were 206 nm for ELU B, 220 nm for ELUE, solid phase extraction (SPE) and internal standard-salicin were selected. Results The recoveriesof Acanthopanax tablets and injection were 90.4% - 96.8% and 96.4% - 99.8% for ELU B, 87.7% -93.3%and 95.7% - 98.5% for ELU E, respectively. The linear ranges were 4.45 - 22.25 μg· mL^(-1) (r =0.999 8) and 5.11 - 25.55 μg·mL^(-1) ( r = 0.999 7) respectively. Conclusion This method can savethe time for cleaning the chromatographic system and improve sensitivity for Acanthopanaxpreparations , thus providing a way to evaluate the quality of Acanthopanax preparations.
基金Supported by the Science and Technology Plan of Liaoning Province, China(No.2006226002)the Project of the Doctor Fund of Hebei University of Science and Technology, China(No.005121)
文摘An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.
文摘Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tra- ditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as mor- phine-positive samples by a strip test, 'were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories.
基金the National Key Basic Research Science Foundation(Grant No.2006CB202501)
文摘In this paper, a method was established to determine the boiling point distribution of hydrocarbon types in diesel. The diesel sample was separated into the saturate and aromatic fractions by means of solid-phase extraction (SPE), and each fraction was analyzed by GC/FID-EIMS. According to the relationship between boiling point and retention time of n-paraffins in the chromatogram, the percentages of saturates and aromatics at each temperature interval were calculated. According to the average mass spectra of the saturate and aromatic fractions at each temperature interval, the hydrocarbon types of the sample were identified through summation of characteristic mass fragments. Using this method, the changes in composition of diesel during hydrotreating process were studied. The results showed that hydrogenation of aromatics is the main reaction during the hydrotreating process. The more rings the aromatics have, the easier the hydrogenation reactions would take place. The aromatics were converted into cycloparaffins via the hydrogenation and saturation process, leading to an increase in low boiling point fractions in the hydrotreated oil.
基金Supported by Xiamen Science and Technology Plan Project(3502Z20123046)A-class Plan Project of Education Department of Fujian Province(JA12465)
文摘[ Objective] The research aimed to develop a new molecular imprinting solid-phase extraction column for the separation and enrichment of melamine in feed. [ Method] The molecular imprinting polymer of melamine was prepared by mass polymerization method. This polymer was used as filler to prepare molecular imprinting polymer solid-phase extraction(MIP-SPE) column of melamine. The solid-phase extraction conditions were optimized and melamine content in concentrated solution was determined by using HPLC. [ Result] Melamine eould be separated selectively from feed and enriehed by self-made MIP-SPE column. It could wipe off complex matrix from feed and the addition recovery rate was 95%. The contrast experiment between MIP-SPE column and NMIP-SPE ( non-imprinted polymer- solid phase extraction) column showed that the extraction efficiency of the former was obviously higher than the latter. [ Conclusion] The home-made MIP- SPE column could be used to separate and enrich melamine in feed efficiently, with a broad application prospect.
文摘A rapid, cost effective and reliable analytical method was developed and validated for the simultaneous determination of four estrogens (17 β-estradiol, 17 α-ethinylestradiol, estrone, and estriol) in compost samples from the biodegradation of biological infectious hazardous wastes. Ultrasonic solvent extraction, using methanol as extraction solvent, coupled with SPE clean-up, using cartridges HLB 60 mg - 6 ml Supelco®<sup></sup> and acetonitrile for reconstitution of eluents, was used for the simultaneous extraction of the four estrogens. Mean recoveries in the range of 98% - 107% were obtained. All compounds were separated in a single gradient run by UHPLC Kinetex<sup>TM</sup> 2.6 μm XB-C18 100 ÅLC (50 × 4.6 mm) column. Analytes were detected via multiple reaction monitoring (MRM) using an AB SCIEX API-5000TM triple quadrupole (Applied Biosystems/MDS SCIEX) with electrospray ionization in negative mode. Isocratic mobile phase of Water:ACN (50:50) resulted to be the optimum. Limits of detection and quantification were on the order of 0.66 ng·g<sup>-1</sup> and 2 ng·g<sup>-1</sup> for all the estrogens. These limits were lower than most of the values reported in the literature for similar matrices. Suitable level of linearity, good repeatability and reproducibility with coefficients of variation is lower than 11.7%, 6.8% and 8.3%, respectively.
基金funded by the Biothechnology and Biological Sciences Research Council (BBSRC),as part of an industrial Collaboration Award in Science and Engineering between University of Portsmouth and AstraZeneca's Brixham Environmental Laboratory,Devon,UK
文摘It is important to understand the adsorption mechanism of chemicals and active pharmaceu-tical ingredients (API) on sewage sludge since wastewater treatment plants are the last barrier before the release of these compounds to the environment. Adsorption models were developed considering mostly hydrophobic API-sludge interaction. They have poor predictive ability, especially with ionisable compounds. This work proposes a solid-phase extraction (SPE) approach to estimate rapidly the API-sludge interaction. Sludge-filled SPE cartridges could not be percolated with API spiked mobile phases so different powders were tested as SPE sludge supports. Polytetrafluoroethylene (PTFE) was selected and tested at different PTFE/sludge ratios under eight different adsorption conditions with three API ionisable compounds. The PTFE/sludge mixtures with 50% or less sludge could be used in SPE mode for API sorption studies with methanol/water liquid phases. The results gave insights into API-sludge interactions. It was found that π-π, hydrogen-bonding and charge-charge interactions were as important as hydrophobicity in the adsorption mechanism of charged APIs on sludge.
基金supported by the National Natural Science Foundation of China(No.20405013)the Scientific Foundation of State Tobacco Monopoly Administration of China(No.110200201017).
文摘A molecularly imprinted polymer (MIP), prepared around a cotinine template, has been synthesized. The feasibility of using the polymer for solid-phase extraction (SPE) of cotinine from biological samples has been investigated. The results show that cotinine can be quantitatively retained and eluted from the polymer. Experiments with human urine samples indicate that clean target analyte is obtained for HPLC with UV detection using the protocol.
基金Supported by the National Natural Science Foundation of China(Nos 20305004 and 20575012), Program for NewCentury Ex-cellent Talents in University of China(No NCET-04-0612), Specialized Research Fund for the Doctoral Program of Higher Education(No 20050386008), and the Science Foundation of Fujian Province(Nos 2005Y015 and D0510006)
文摘Capillary electrochromatography (CEC) is a hybrid technique that couples the good selectivity of high-performance liquid chromatography (HPLC) and the high separation efficiency of capillary electrophoresis (CE). Both charged and uncharged compounds can be separated effectively using CEC. In some cases, however, the bubbles that generated in the capillary column in pure CEC performed on commercial CE instruments will cause unstable current and even disrupt the separation when the concentration of buffer is very high. By applying pressure on the electrochromatographic separation via a micro-HPLC pump, pressurized capillary electrochromatography ( pCEC ) combines two driving factors of the electroosmotic flow (EOF) and the pressure flow, thereby increasing the speed and the selectivity of separation and suppressing the bubble formation. Moreover,
文摘For purpose of purification and enrichment, environmental samples usually need to be pretreated before analysis because of low concentration of residual organic matters. Solid-phase extraction (SPE) is one of the frequently used methods of pretreatment. This article introduces the methodological principle and flow channel of SPE as well as the categories of frequently used small extraction column, analyzes the application of online SPE technology in environmental analysis, generalizes the advantages of online SPE and sets forth its developmental trend.
文摘A new multi-residue method based on solid-phase extraction (SPE) with centrifugation was developed for determination and quantitation of 67 pesticides in water samples. Two SPE cartridges were tested: Chromabond C18 and Oasis HLB. Parameters that influence the extraction efficiency such as the eluent volume, the sample loading volume, the addition of organic solvent to water sample, sorbent drying and elute concentration were optimized. The innovation of this work was the examination of the use of a centrifugation technique in both the drying and elution steps. When combined with centrifugation, the volume of the elution solvent was reduced to 2 mL and the time for sorbent drying decreased also to 10 min under vacuum. Under the optimized conditions, this method showed good recoveries higher than 65% - 68% for the 67 analyzed pesticides using the C18 and HLB cartridges with relative standard deviations lower than 9.7% - 12.3%. Limits of quantification were between 2 and 20 ng.L–1. The simplicity of the described method, use of less of organic solvent, short procedure time, and good recoveries demonstrate the advantages of this environmentally friendly approach for routine analysis of numerous samples.