期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Implementation of Embedded Ethernet Based on Hardware Protocol Stack in Substation Automation System 被引量:1
1
作者 马强 赵建国 刘炳旭 《Transactions of Tianjin University》 EI CAS 2008年第2期153-156,共4页
Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system(SAS).This paper introduces the current applying situation about embedded Ethernet in SAS... Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system(SAS).This paper introduces the current applying situation about embedded Ethernet in SAS First.After analyzing the protocol levels used in SAS based on embedded Ethernet and the differences between the TCP and UDP,UDP/IP is selected as the communication protocol between the station-level and bay-level devices for its real-time characteristic.Then a new kind of implementation of the embedded Ethernet is presented based on hardware protocol stack.The designed scheme can be implemented easily,reduce cost significantly and shorten developing cycle. 展开更多
关键词 embedded Ethernet substation automation system hardware protocol stack UDP W3100A
下载PDF
A Simulation Environment for Intrusion Detection System in IEC 61850 Based Substation Automation System
2
作者 YooJin Kwon Seongho Ju Yonghun Lim 《Computer Technology and Application》 2013年第7期335-340,共6页
Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for int... Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for intrusion detection system in IEC 61850 standard-based substation automation system is provided to test simulated attacks on IEDs (intelligent electronic devices). Intrusion detection is the process of detecting malicious attacker, so it is an effective and mature security mechanism to protect electrical facility. However, it is not harnessed when securing IEC 61850 automated substation. To prove the detection capability of the system testing environment was developed to analyze and test attacks simulated with different test cases. It shows that the simulation environment works accordingly to various network traffic scenarios and eventually proves the functionality of intrusion detection system to be later deployed in the real IEC 61850 based substation automation system site. 展开更多
关键词 IEC 61850 substation automation system simulation environment.
下载PDF
Method to Quantifying the Logical Node Importance for IEC 61850 Based Substation Automation Systems
3
作者 Jie Yang Yihao Guo +2 位作者 Chuangxin Guo Zhe Chen Shenghan Wang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第1期272-283,共12页
The problem of logical node(LN)importance quantification in an IEC 61850 based substation automation system(SAS)is investigated in this paper.First,a weighted and directed static complex network model is established b... The problem of logical node(LN)importance quantification in an IEC 61850 based substation automation system(SAS)is investigated in this paper.First,a weighted and directed static complex network model is established by analyzing the characteristics of SAS,according to IEC 61850.Then,we propose a method,which combines topology value and information adjunction value by introducing a first-order linear feedback controller to quantify the value of LNs.On this basis,some definitions for equivalent network conversion are proposed to greatly reduce the complexity of the original network topology.Also,the absolute value and relative value are introduced to quantify LN importance from the perspective of the node’s necessity and influence,respectively.Finally,simulation results of the case study demonstrate that the proposed method is effective and provides a broader and clearer perspective for viewing the logical node importance for IEC61850 based SAS. 展开更多
关键词 Absolute value complex network dynamics equivalent network IEC 61850 logical node importance quantification relative value substation automation system
原文传递
Teaching Protective Relaying Design and Application Using New Modeling and Simulation Tools
4
作者 Jinfeng Ren Mladen Kezunovic 《Journal of Energy and Power Engineering》 2012年第5期762-770,共9页
As the smart grid concepts are emphasized lately, the need to modernize the power engineering education is also well recognized. This paper presents a set of newly developed modeling, simulation and testing tools aime... As the smart grid concepts are emphasized lately, the need to modernize the power engineering education is also well recognized. This paper presents a set of newly developed modeling, simulation and testing tools aimed at better understanding of the design concept and related applications for protective relaying and substation automation solutions for the smart grid. Since the smart grid applications require integration of data from multiple IEDs (intelligent electronic devices), understanding properties of each IED type in detail, as well as their responses to the power system events is needed. In addition, understanding the communication requirements to perform data integration is also important. To illustrate how the mentioned smart grid issues may be taught, the following advanced teaching approaches are presented: (1) Use of modeling and simulation means to better understand interaction between the relays and power system; (2) Use of IED test facilities to better understand performance of physical devices used for protection, monitoring and control; (3) Utilization of communication network modeling tools to simulate the communication network within SAS (substation automation system). Examples showing the use of proposed techniques for teaching the fundamentals and applications are presented. The examples demonstrate the adequacy and efficiency of the proposed techniques. 展开更多
关键词 Smart grid power engineering education MODELING protective relaying SIMULATION lED (intelligent electronic device) SAS substation automation system).
下载PDF
A Study on the Testing Procedures of IEC 61850 Based Transformer Protective lED
5
作者 N.H. Lee B.T. Jang Y.H. Kim Y.H. An J.Y. Han E.B. Shim 《Journal of Energy and Power Engineering》 2010年第11期58-62,共5页
Korea Electric Power Corporation in charge of the power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology", is performing the verification of perf... Korea Electric Power Corporation in charge of the power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology", is performing the verification of performance of the substation automation system based on IEC 61850. In order to verify a transformer protective lED that might be operating in substation automation system, the new standardized document and procedures are required in the aspect of the utility like KEPCO. But there is nothing to describe systematically how to verify IEC 6 1850 based lED in the system environment except an individual IED testing way. This paper will present the substation automation system based ways and procedures to verify the protective function of the IED using UML (Unified Modeling Language). 展开更多
关键词 IED conformance testing IEC61850 substation automation testing procedure.
下载PDF
Implementation and design of a communication system of an agent-based automated substation
6
作者 LIN Yong-jun LIU Yu-tao ZHANG Dan-hui 《Frontiers of Electrical and Electronic Engineering in China》 CSCD 2006年第4期396-399,共4页
A substation system requires that communica-tion be transmitted reliably,accurately and in real-time.Aimed at solving problems,e.g.,flow confliction and sensi-tive data transmission,a model of the communication sys-te... A substation system requires that communica-tion be transmitted reliably,accurately and in real-time.Aimed at solving problems,e.g.,flow confliction and sensi-tive data transmission,a model of the communication sys-tem of an agent-based automated substation is introduced.The running principle is discussed in detail and each type of agent is discussed further.At the end,the realization of the agent system applied to the substation is presented.The outcome shows that the communication system of an agent-based automated substation improves the accuracy and reliability of the data transfer and presents it in real-time. 展开更多
关键词 data transfer substation automation agent system communication system
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部