The relationship between indoor air quality(IAQ)and perceived air quality(PAQ)-a review and case analysis of Chinese residential environment 被引量:2
1
作者 Jingjing Pei Meinan Qu +2 位作者 Luyao Sun Xueyong Wang Yihui Yin 《Energy and Built Environment》 2024年第2期230-243,共14页
Due to the majority of time people spent indoors,indoor air quality is not only critical to people’s health,comfort,but can also significantly influence occupants perception on indoor environment.Air quality is close... Due to the majority of time people spent indoors,indoor air quality is not only critical to people’s health,comfort,but can also significantly influence occupants perception on indoor environment.Air quality is closely related to many factors including thermal parameters,pollutant concentrations,and ventilation performance.However,the current building indoor air quality evaluation method is based the objective measurement of indoor parameters,without considering occupants’subjective perception.This paper is aimed at summarizing a profound review on the PAQ evaluation method.Comparisons among various PAQ evaluating methods with advantages,similarities and differences were conducted.Analysis of literatures about indoor air quality in Chinese residential buildings field is also summarized,and discussion on the subjective influence of temperature and relative humidity,venti-lation performance,volatile organic compounds(VOCs)concentration,and particulate matters on perceived air quality is carried out. 展开更多
关键词 Perceived air quality temperature and relative humidity Volatile organic compound Ventilation Particulate matter
原文传递
Intercomparison of GPS radiosonde soundings during the eastern tropical Indian Ocean experiment 被引量:4
2
作者 XIE Qiang HUANG Ke +5 位作者 WANG Dongxiao YANG Lei CHEN Ju WU Zewen LI Daning LIANG Zhiyan 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2014年第1期127-134,共8页
Temperature and relative humidity profiles derived from two China-made global positioning system(GPS) radiosondes(GPS-TK and CF-06-A) during the east tropical Indian Ocean(ETIO) experiment were compared with Vai... Temperature and relative humidity profiles derived from two China-made global positioning system(GPS) radiosondes(GPS-TK and CF-06-A) during the east tropical Indian Ocean(ETIO) experiment were compared with Vaisala RS92-SGP to assess the performances of China-made radiosondes over the tropical ocean.The results show that there have relative large biases in temperature observations between the GPSTK and the RS92-SGP in the low troposphere,with a warm bias of greater than 2 K in the day and a cooling bias of 0.6 K at night.The temperature differences of the CF-06-A were small in the troposphere both in daytime and nighttime,and became large peak-to-peak fluctuations in the stratosphere.The intercomparison of the relative humidity showed that the CF-06-A had large random errors due to the limitation of sensors and the lack of correction scheme,and the GPS-TK had large systematic biases in the low troposphere which might be related to the temperature impact.GPS height measurements are clearly suitable for China-made radiosonde systems operation.At night,the CF-06-A and the GPS-TK could provide virtual potential temperature and atmospheric boundary layer height measurements of suitable quality for both weather and climate research.As a result of the intercomparison experiment,major errors in the Chinamade radiosonde systems were well indentified and subsequently rectified to ensure improving accuracy for historical and future radiosondes. 展开更多
关键词 global positioning system radiosonde temperature and relative humidity profile systematic bias random error tropical ocean
下载PDF
Indoor thermal environment of wooden-plank wall dwellings in summer in Chongqing
3
作者 徐亚男 杨真静 PENG Ming-xi 《Journal of Chongqing University》 CAS 2016年第3期119-126,共8页
There are a large number of wooden-plank wall dwellings, a kind of traditional house with regional characteristics, existing in Chongqing area. We chose a typical house in Chongqing as the subject and measured it duri... There are a large number of wooden-plank wall dwellings, a kind of traditional house with regional characteristics, existing in Chongqing area. We chose a typical house in Chongqing as the subject and measured it during summer to research the situation of the indoor thermal comfort of wooden-plank wall dwellings. Based on the particularity of local residents' living habit and the characteristics of the local buildings, we analyzed the data of the field measurement and evaluated the thermal environment with APMV. The results show that the indoor thermal comfort of wooden-plank wall dwellings in summer is improved mainly by natural ventilation. 展开更多
关键词 indoor thermal environment field measurement temperature and relative humidity wind speed thermal comfort