期刊文献+
共找到43篇文章
< 1 2 3 >
每页显示 20 50 100
Axial load-share ratio testing to assess the healing of open tibial fractures treated with the Taylor Spatial Frame
1
作者 Zhao Liu Jin-Wei Liu +7 位作者 Qi-Jun Zhao Hong-Zhou Li Ning-Ning Zhang Hong-Liang Zhang Yu Gou Xun Sun Tao Zhang Wei-Guo Xu 《Biomedical Engineering Communications》 2024年第3期23-30,共8页
Background:The Taylor Spatial Frame(TSF)has gained popularity among orthopedic surgeons for treating open fractures.However,a key challenge is the timely and safe removal of the frame.This study assessed the efficacy ... Background:The Taylor Spatial Frame(TSF)has gained popularity among orthopedic surgeons for treating open fractures.However,a key challenge is the timely and safe removal of the frame.This study assessed the efficacy and safety of axial load-share ratio(ALSR)testing to evaluate callus healing strength after TSF treatment of open tibial fractures.Methods:A retrospective case-control study was conducted,analyzing 180 adult patients with open tibial fractures treated at Tianjin Hospital’s Orthopedic Limb Correction Unit between August 2019 and August 2022.All patients underwent TSF external fixation surgery,and were divided into two groups based on ALSR testing.Group I(92 patients)underwent ALSR testing,with frame removal if the test value fell below 5%.Traditional methods were used for fixator removal guidance in Group II(88 patients).Clinical outcomes,including fixation duration,complications after fixator removal,and Johner-Wruhs functional scores,were compared between the two groups.Results:The groups showed no statistically significant differences(P>0.05)in sex,age,injury side,body mass index,surgery timing,or fracture type.Group I had a significantly shorter fixation duration(25.85±5.57 weeks)compared to Group II(31.82±6.98 weeks)(P<0.05).Following fixator removal,Group I demonstrated superior Johner-Wruhs scores compared to Group II,indicating better outcomes(P<0.05).Complication rates did not differ significantly between the groups at the last follow-up(P>0.05).Conclusion:Regular postoperative ALSR testing could safely and effectively guide TSF removal following open tibial fracture treatment.This method significantly reduced fixation duration compared to traditional guidance methods while maintaining efficacy and safety. 展开更多
关键词 tibial fractures external fixators fracture healing axial load
下载PDF
Early complications of preoperative external traction fixation in the staged treatment of tibial fractures:A series of 402 cases 被引量:1
2
作者 Jia-Zhao Yang Wan-Bo Zhu +1 位作者 Liu-Bing Li Qi-Rong Dong 《World Journal of Clinical Cases》 SCIE 2020年第20期4743-4752,共10页
BACKGROUND Different external skeletal fixators have been widely used in preoperative traction of high-energy tibial fractures prior to a definitive surgical treatment.However,the early complications associated with t... BACKGROUND Different external skeletal fixators have been widely used in preoperative traction of high-energy tibial fractures prior to a definitive surgical treatment.However,the early complications associated with this staged treatment for traction and soft tissue injury recovery have rarely been discussed.AIM To analyze the early complications associated with preoperative external traction fixation in the staged treatment of tibial fractures.METHODS A total of 402 patients with high-energy tibial fractures treated using preoperative external traction fixation at a Level 1 trauma center from 2014 to 2018 were enrolled in this retrospective study.Data regarding the demographic information,Tscherne soft tissue injury,fracture site,entry point placement,and duration of traction were recorded.Procedure-related complications such as movement and sensation disorder,vessel injury,discharge,infection,loosening,and iatrogenic fractures were analyzed.RESULTS The mean patient age was 42.5(18-71)years,and the mean duration of traction was 7.5(0-26)d.In total,19(4.7%)patients presented with procedure-related complications,including technique-associated complications in 6 patients and nursing-associated complications in 13.Differences in the incidence of complications with respect to sex,affected side,soft tissue injury classification,and fracture sites were not observed.However,the number of complications due to hammer insertion was significantly reduced than those due to drill insertions(2.9%vs 7.4%).CONCLUSION We found a low incidence of early complications related to the fixation.Furthermore,the complications were not significantly associated with the severity of the soft tissue injury and fracture site.Although relatively rough and more likely to cause pain,the number of complications associated with hammer insertion was significantly smaller than that of complications associated with drill insertion. 展开更多
关键词 tibial fracture External fixation Bone traction COMPLICATIONS Vessels injury Nerve injury
下载PDF
Three predictive scores compared in a retrospective multicenter study of nonunion tibial shaft fracture
3
作者 Davide Quarta Marco Grassi +3 位作者 Giuliano Lattanzi Antonio Pompilio Gigante Alessio D'Anca Domenico Potena 《World Journal of Orthopedics》 2024年第6期560-569,共10页
BACKGROUND Delayed union,malunion,and nonunion are serious complications in the healing of fractures.Predicting the risk of nonunion before or after surgery is challenging.AIM To compare the most prevalent predictive ... BACKGROUND Delayed union,malunion,and nonunion are serious complications in the healing of fractures.Predicting the risk of nonunion before or after surgery is challenging.AIM To compare the most prevalent predictive scores of nonunion used in clinical practice to determine the most accurate score for predicting nonunion.METHODS We collected data from patients with tibial shaft fractures undergoing surgery from January 2016 to December 2020 in three different trauma hospitals.In this retrospective multicenter study,we considered only fractures treated with intramedullary nailing.We calculated the tibia FRACTure prediction healING days(FRACTING)score,Nonunion Risk Determination score,and Leeds-Genoa Nonunion Index(LEG-NUI)score at the time of definitive fixation.RESULTS Of the 130 patients enrolled,89(68.4%)healed within 9 months and were classified as union.The remaining patients(n=41,31.5%)healed after more than 9 months or underwent other surgical procedures and were classified as nonunion.After calculation of the three scores,LEG-NUI and FRACTING were the most accurate at predicting healing.CONCLUSION LEG-NUI and FRACTING showed the best performances by accurately predicting union and nonunion. 展开更多
关键词 TRAUMA BONE tibial fracture NONUNION SCORES Prediction model
下载PDF
Exclusive Fibula Osteosynthesis for Treating Open Fractures Gustillo I-III B of the Distal Half of the Leg Bones in a Resources-Limited Setting
4
作者 Georges Kuyigwa Toha Paul Munguakonkwa Budema +2 位作者 Ona Longombe Ahuka Akinja Bitum Uwonda Jean Marie Vianney Kabangu Tshimbila 《Open Journal of Orthopedics》 2023年第3期108-121,共22页
Introduction: Management of open leg bones fractures is a challenging health issue for the surgeon, particularly true in resource-limited settings. In this study, we evaluate exclusive fibular osteosynthesis in the tr... Introduction: Management of open leg bones fractures is a challenging health issue for the surgeon, particularly true in resource-limited settings. In this study, we evaluate exclusive fibular osteosynthesis in the treatment of open fractures of the distal half of the leg bones as a therapeutic option in our context. Methods: This is a prospective, experimental, multicenter study of 30 open fractures of the distal half of the leg bones treated with exclusive fibula osteosynthesis, conducted in 3 hospitals in the DRC from January 1, 2013 to September 30, 2016. Results: The age range of 20 to 40 years grouped 22 (73.4%) patients, the sex ratio was 1:1 and the unemployed were the most involved with 16 (53.3%) cases. The Gustilo II, I, III B and III A types represented 40%, 33.3%, 20% and 6.7%, respectively. The fractures were located in the distal third in 12 (40%) cases, in the middle third in 11 (36.7%) cases, and in both malleoli in 7 cases (23.3%). Osteosynthesis of the fibula by screw plate was applied in 22 (73.3%) patients and pinning in 8 (26.7%). Satisfactory reduction of the tibial fracture site was achieved in 29 (96.7%) cases and 100% bone healing was achieved within an average of 10 weeks. Four (13.3%) loss of alignment, 1 (3.3%) infection, 1 (3.3%) skin necrosis and 2 (6.7%) ankle stiffness complicated our fractures. Conclusion: Exclusive osteosynthesis of the fibula as a common technique for fractures of the distal half of the leg bones allowed us to reduce, immobilize and consolidate the tibial fracture in the required time and to preserve the mobility of the ankle. 展开更多
关键词 Fibular Exclusive Osteosynthesis Open tibial fractures Resources Limited Settings tibial fracture Consolidation
下载PDF
Comparative prospective study between medial and lateral distal tibial locking compression plates for distal third tibial fractures 被引量:8
5
作者 Sandeep Garg Vikram Khanna +3 位作者 Mahaveer Prashad Goyal Narendra Joshi Amrut Borade Ishan Ghuse 《Chinese Journal of Traumatology》 CAS CSCD 2017年第3期151-154,共4页
Purpose: Tibial fracture is the most common long bone fracture. Distal third tibial fractures are chal- lenging though open reduction and plating can result in anatomical reduction and rigid fixation. This paper aime... Purpose: Tibial fracture is the most common long bone fracture. Distal third tibial fractures are chal- lenging though open reduction and plating can result in anatomical reduction and rigid fixation. This paper aimed to evaluate and compare the results of medial and lateral locking compression plates for distal third tibial fractures. Methods: This prospective clinical study involved 36 patients with distal tibial fractures admitted in Department of Orthopaedics, Sawai Mansingh Medical College & Affiliated Hospital, Jaipur, India, from June 2011 to May 2012, including 29 closed fractures and 7 open fractures at the mean age of 38.9 years. Thirty-six patients were divided equally into two groups based on treatment method, including medial plating group (18 patients) and lateral plating group (18 patients). They were followed up for at least 5 months after discharge. The functional outcomes were evaluated using Tenny and Wiss clinical assess- ment criteria. Results: Malunion was found in 3 cases of medial plating group and in 1 case of lateral plating group. In the medial plating group, there were 5 cases of superficial infections, 1 deep infection, 1 nonunion and 3 wound dehiscence. In the lateral plating group, there was 1 case of superficial infections, 1 deep infection and 1 nonunion, in the lateral plating group, 4 patients reported feeling the plates and screws but none of them asked to remove the hardware. In the medial plating group, 9 patients reported symptomatic hardware problems and 7 asked to remove the hardware. The number of cases graded as excellent/good/ fair was 1/8/7 in the medial plating group and 3/7/7 in the lateral plating group respectively. In the medial plating group, the final range of motion was 17.2° in ankle dorsiflexion and 30.7° in ankle plantar flexion. In the lateral plating group, the final range of motion was 19° in ankle dorsiflexion and 34.2° in ankle plantar flexion. Conclusion: Lateral plating of distal tibia is safe and feasible, which can provide biological fixation and prevent the soft tissue complications associated with medial plating. 展开更多
关键词 tibial fractures Bone plates Open fracture reduction
原文传递
Classification to guide internal fixation for tibial fracture 被引量:5
6
作者 张文玺 郑志良 +1 位作者 吉跃平 乔志军 《Chinese Journal of Traumatology》 CAS 2008年第6期375-379,共5页
Objective: To explore a classification method which can provide the clinical guidance for internal fixation of tibial fracture. Methods: The different fractures were fixed according to their mechanical classificatio... Objective: To explore a classification method which can provide the clinical guidance for internal fixation of tibial fracture. Methods: The different fractures were fixed according to their mechanical classification. Totally, 71 cases of tibial plateau fracture, tibial proximal fracture, tibial distal fracture and Pilon fracture were analyzed to test this selective principle. Results: All 71 patients were followed up for 6-32 months. The displacement was seldomly observed in cases treated acccording to the classification principle, while some cases against the principle had postoperative displacement.The difference was statistically significant (P〈0.05). It was proved that there was remarkable correlation between tibial fracture classification, internal fixator and fixation methods. Conclusion: Types Ⅲa3, Ⅲb 1 and Ⅲb2 fractures without eccentric moment should be fixed with double plates or angle-stable materials combined with locking structure, otherwise displacement may occur. 展开更多
关键词 tibial fractures fracture fixation internal CLASSIFICATION
原文传递
Comparative study on treatment of midshaft tibial fracture with expandable and interlocking intramedullary nails 被引量:5
7
作者 毕擎 朱丹杰 +3 位作者 邱斌松 洪剑飞 章水均 夏冰 《Chinese Journal of Traumatology》 CAS 2007年第4期228-232,共5页
Objective : To evaluate the clinical results of treatment of midshaft tibial fracture with expandable intramedullary nails compared with interlocking intramednilary nails. Methods: From June 2003 to August 2005, 46... Objective : To evaluate the clinical results of treatment of midshaft tibial fracture with expandable intramedullary nails compared with interlocking intramednilary nails. Methods: From June 2003 to August 2005, 46 patients (27 males and 19 females, aged 20-74 years, mean =38.4 years ) with midshaft tibial fracture were treated surgically in our department. The causes of fractures were traffic injury in 21 patients, fall injury in 6, tumbling injury in 11 and crushing injury in 8. According to AO/ ASIF classification, Type A fracture was found in 16 patients, Type B in 11, Type C1 in 5, and Type C2 in 2. Open fractures were found in 12 patients, according to Gustilo classification, Type Ⅰ in 9 patients and Type Ⅱin 3 patients. Based on the patients'consent, 24 patients were treated with expandable intramedullary nails (Group A ) and 22 with interlocking intramedullary nails (Group B ). The operation time, blood loss during operation, X-ray fluoroscopic times, hospitalization time, weight bearing time after operation, healing time of fracture and complications of all the patients were recorded. The clinical effects of all the cases were evaluated according to the criteria of Johner-Wruhs. Results: All the patients were followed up for 12,34 months ( mean = 16.2 months). The time of operation, the blood loss, X-ray fluoroscopic times, hospitalization time and healing time of fracture of Group A significantly decreased (P 〈 0.05 ) compared with those of Group B, but the time for weight bearing after operation, the Johner- Wruhs degree of clinical effects and complications had no significant difference between Group A and Group B (P〉0.05). Conclusions: Expandable intramedullary nail can shorten operation time, decrease blood loss and reduce invasion, which is a safe and effective treatment method for tibial midshaft fracture. 展开更多
关键词 fracture fixation intramedullary tibial fractures Clinical medicine
原文传递
Hoffa fracture associated with femoral shaft and proxi-mal tibial fractures: report of two cases 被引量:5
8
作者 Anuj Jain Prakash Agrawal +1 位作者 Manish Chadha Amite Pankaj 《Chinese Journal of Traumatology》 CAS 2012年第6期367-369,共3页
Solitary coronal shear fractures of femo- ral condyle, such as Hoffa's fracture, are usually associated with supracondylar or intercondylar fractures of the femur. These fractures are rare and seen in the context of ... Solitary coronal shear fractures of femo- ral condyle, such as Hoffa's fracture, are usually associated with supracondylar or intercondylar fractures of the femur. These fractures are rare and seen in the context of high energy mechanism leading to multiple injuries; therefore a thorough workup of the patient is required to rule out other significant injuries. Hoffa's fracture associated with femo- ral shaft and proximal tibial fractures is extremely rare and no such injury has been reported previously. We report two such cases which were managed with standard operativefixation techniques and demonstrated good to excellent func- tional outcome after a follow-up of one year. This report emphasizes that high index of suspicion is required for di- agnosis of these injuries and a thorough workup is manda- tory to rule out other associated injuries. We also propose a possible mechanism of injury. 展开更多
关键词 Femoral fractures tibial fractures fracture fixation
原文传递
Biomechanical Comparison of Gourd-shaped LCP versus LCP for Fixation of Comminuted Tibial Shaft Fracture 被引量:1
9
作者 徐国辉 刘勃 +5 位作者 张奇 王娟 陈伟 刘月驹 彭阿钦 张英泽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第2期250-257,共8页
The purpose of this study was to compare monotonic biomechanical properties of gourd-shaped LCP fixation with LCP fixation of human tibial shaft in gap fracture mode. Twenty paired fresh cadaveric human tibias were ra... The purpose of this study was to compare monotonic biomechanical properties of gourd-shaped LCP fixation with LCP fixation of human tibial shaft in gap fracture mode. Twenty paired fresh cadaveric human tibias were randomly divided into 4 groups (5 pairs each): (1) axial loading sin- gle cycle to failure testing, (2) torsion single cycle to failure testing, (3) 4-point bending single cycle to failure testing, and (4) dynamic 4-point bending testing. A 7-hole 4.5 mm gourd-shaped LCP was se- cured on the anteromedial surface of 1 randomly selected bone from each pair, respectively, using 6 locking screws in the 1st, 2nd, 3rd, 5th, 6th and 7th hole with the middle hole unfilled and just located at the mid-diaphysis of the tibia. A 7-hole 4.5 mm LCP was secured on the other bone with the same method. Standard AO/ASIF techniques were used. After fixation finished, a 10 mm gap in the mid-diaphysis of tibia was created, centrally located at the unfilled hole. The axial, torsional, and bending stiffness and failure strengths were calculated from the collected data in static testings and statisti- cally compared using paired Student's t-test. The 4-point bending fatigue lives of the two constructs were calculated from the dynamic testing data and also statistically compared using paired Student's t-test. Failure modes were recorded and visually analyzed. P〈0.05 was considered significant. Results showed that the axial, torsional and bending stiffness of gourd-shaped LCP construct was greater (4%, 19%, 12%, respectively, P〈0.05) than that of the LCP construct, and the axial, torsional and bending failure strengths of gourd-shaped LCP construct were stronger (10%, 46%, 29%, respectively, P〈0.05) than those of the LCP construct. Both constructs failed as a result of plate plastic torsional deformation. After axial loading and 4-point bending testings, LCP failed in term of an obvious deformation of bent apex just at the unfilled plate hole, while the gourd-shaped LCP failed in term of a deformation of bent arc between the 3rd and 5th holes, which indicated a more consistent stress distribution on gourd-shaped LCP. Fatigue life of gourd-shaped LCP construct was significantly greater than LCP construct (153 836±2 228 vs. 132 471±6 460 cycles, P〈0.01). All constructs failed as a result of fracture of the plate through the compression hole of the unfilled combination screw hole. The biomechanical testing showed that gourd-shaped LCP can provide greater stiffness and strength, and longer fatigue life than LCP. The gourd-shaped LCP may be more advantageous mechanically and may reduce the plate breakage rate clinically. 展开更多
关键词 tibial fracture BIOMECHANICS locking compression plate fatigue
下载PDF
Comparison of closed reduction and expert tibial nailing with open reduction and plate and screw fixation in the treatment of two segmental tibial fractures 被引量:3
10
作者 Ding-Chuan Zhu Lei Liu +2 位作者 Feng Gao Qin Li Bin Zhang 《Chinese Journal of Traumatology》 CAS CSCD 2015年第4期219-222,共4页
Purpose: To compare the outcomes of closed reduction and expert tibial nailing (ETN) versus open reduction and plate and screw fixation in treating two segmental tibial fractures. Methods: This study included 53 c... Purpose: To compare the outcomes of closed reduction and expert tibial nailing (ETN) versus open reduction and plate and screw fixation in treating two segmental tibial fractures. Methods: This study included 53 cases of two segmental fractures of the tihial shaft. They were admitted to our department between March 2010 and June 2013 and treated respectively by closed reduction and ETN (ETN group, n = 31 ) or open reduction fixation with plate and screws (PS group, n = 22). The general data of two groups including gender, age, injury cause, fracture type, etc showed no significant difference (p 〉 0.05). To compare the therapeutic effects between two groups, the intraoperative condition, post- operative function and related complications were investigated. Results: All the patients were successfully followed up. The period was 19.2 months for ETN group and 20.5 months for PS group. All the fractures in ETN group had union without complications such as malunion, infection, or osteofascial compartment syndrome; whereas there were 3 cases of superficial infection cured by repeated dressing change and 2 cases of delayed union in PS group. The total incidence of complication in PS group was 22.7% (5/22), much higher than that in ETN group (p 〈 0.05). Moreover, ETN group showed a better result in terms of intraoperative blood loss, operation time, postoperative weight bearing time and fracture union time. In ETN group, at one-year follow-up, Johner-Wruhs' criteria was adopted to assess the postoperative function, which was reported as excellent in 18 cases, good in 10 cases and fair in 3 cases in ETN group (100% excellent-good rate). While in PS group, the result was excellent in 10 cases, good in 7 cases, fair in 3 cases and poor in 2 cases (77.3% excellent-good rate). The comparison was insignificant (p 〉 0.05). Conclusion: Compared with plate and screw fixation, ETN fixation has the advantages of fewer complications, shorter operation time, being less invasive, earlier postoperative rehabilitation and weight bearing, quicker fracture union and better functional recovery, thus being an effective way to treat two segmental tibial fractures. 展开更多
关键词 Expert tibial nail Segmental tibial fractures fracture fixation Internal
原文传递
Outcome of application of primary versus secondary Illizarov's fixator in open tibial shaft fractures 被引量:1
11
作者 Anil Joshi Saurabh Singh +3 位作者 Sudeep Jain Narender Rohilla Vivek Trikha Chandra Yadav 《World Journal of Emergency Medicine》 CAS 2016年第3期221-226,共6页
BACKGROUND: The present study aimed to compare outcome of primary and secondary Illizarov's fi xator application as a treatment method for type III open tibial fractures in terms of nonunion and wound infection.ME... BACKGROUND: The present study aimed to compare outcome of primary and secondary Illizarov's fi xator application as a treatment method for type III open tibial fractures in terms of nonunion and wound infection.METHODS: This prospective study was done in a tertiary care center. Forty-eight type III tibial fractures were treated with Illizarov's apparatus between 2008 and 2011. The patients were divided into two groups depending on the treatment protocol, timing of wound closure and Illizarov's application, primary(n=28) and secondary(n=20).RESULTS: In the primary group, healing was achieved in all 28 patients. The median time to recovery was 24 weeks, and the median number of operations was 3. There were 6 patients with a bone defect. In the secondary group, complete recovery was achieved in 18 out of 20 patients. The median time to recovery was 30 weeks, and the median number of operations 5. There were 9 patients with a bone defect. The median time to recovery and the number of operations were signifi cantly smaller in patients undergoing primary operation. Union was 100% in the primary group and more than 95% in the secondary group. Chronic osteomyelitis persisted in one patient and below amputation was done in one patient in the secondary group.CONCLUSION: Primary wound closure and Illizarov's fixation required a smaller number of operations and shorter time to recovery than secondary wound closure and Illizarov's fi xation, mostly due to a signifi cantly less number of patients with a bone defect in the primary group. 展开更多
关键词 Open fractures Limb salvage DEBRIDEMENT Illizarov’s fi xator tibial fractures
下载PDF
Posterior coronal plating for tibial fractures: technique and advantages
12
作者 Montu Jain Roop Singh Arun Madharia 《Chinese Journal of Traumatology》 CAS CSCD 2014年第2期84-87,共4页
Objective: Tibial shaft fractures are straightforward to treat but when associated with soft tissue injury particularly at the nail entry/plate insertion site or there is significant comminution proximally or a large... Objective: Tibial shaft fractures are straightforward to treat but when associated with soft tissue injury particularly at the nail entry/plate insertion site or there is significant comminution proximally or a large butterfly fragment/a second split component in the posterior coronal plane, it is a challenge to the treating surgeon. The aim of the present report is to describe the technique of posterior coronal plating in such a scenario and its ad- vantages. Methods: Between July 2008 and June 2011, 12 patients were prospectively treated by this approach using 4.5 mm broad dynamic compression plates. Results: The time of bony consolidation and full weight bearing averaged 21.7 weeks (range, 16-26 weeks). Patients were followed up for at least 24 months (range, 24-48 months). At 1 year postoperatively, no loss in reduction or alignment was observed. Mean Hospital for Lower Extremity Measurement Functional Score was 72.8 (range, 64-78). All patients were satisfied with their treatment outcomes. Conclusion: Direct posterior approach and fixation using prone position helps to visualise the fracture fragments and provide rigid fixation. The approach is simple and extensile easily, apart from advantages of less soft tissue and hardware problems compared to standard medial or lateral plating. 展开更多
关键词 tibial fractures Bone plates Orthopedic procedures
原文传递
Reamed or unreamed intramedullary nailing for tibial fractures: a meta-analysis
13
作者 Yu Guangshu Lin Yanbin +1 位作者 Wang Yu Xu Zhiqing 《Chinese Journal of Traumatology》 CAS CSCD 2014年第4期229-234,共6页
Objective:To compare the treating effects of different intramedullary nailing methods on tibial fractures in adults.Methods:Literature reports in both Chinese and English languages were retrieved (from the earliest... Objective:To compare the treating effects of different intramedullary nailing methods on tibial fractures in adults.Methods:Literature reports in both Chinese and English languages were retrieved (from the earliest available records to October 1,2013) from the PubMed,FMJS,CNKI,Wanfang Data using randomized controlled trials (RCTs) to compare reamed and unreamed intramedullary nailing for treatment of tibial fractures.Methodological quality of the trials was critically assessed,and relevant data were extracted.Statistical software Revman 5.0 was used for data-analysis.Results:A total of 12 randomized controlled trials,comprising 985 patients (475 in the unreamed group and 510 in the reamed group),were eligible for inclusion in this meta-analysis.The results of metaanalysis showed that there were no statistically significant differences between the two methods in the reported outcomes of infection (RR=0.64; 95%CI,0.39 to 1.07;P=0.09),compartment syndrome (RR=1.44; 95%CI,0.8to 2.41; P=0.16),thrombosis (RR=1.29; 95%CI,0.43to 3.87; P=0.64),time to union (WMD=5.01; 95%CI,-1.78 to 11.80; P=0.15),delayed union (nonunion)(RR=1.56; 95%CI,0.97 to 2.49; P=0.06),malunion (RR=1.75; 95%CI,1.00 to 3.08; P=0.05) and knee pain (RR=0.94; 95%CI,0.73 to 1.22; P=0.66).But there was a significantly higher fixation failure rate in the unreamed group than in the reamed group (RR=4.29; 95%CI,2.58to 7.14; P<0.00001).Conclusion:There is no significant difference in the reamed and unreamed intramedullary nailing for the treatment of tibial fractures,but our result recommends reamed nails for the treatment of closed tibial fractures for their lower fixation failure rate. 展开更多
关键词 fracture fixation intramedullary tibial fractures META-ANALYSIS
原文传递
Locking compression plate+T-type steel plate for postoperative weight bearing and functional recovery in complex tibial plateau fractures 被引量:6
14
作者 Hai-Feng Li Tao Yu +2 位作者 Xing-Fei Zhu Hua Wang Ying-Qi Zhang 《World Journal of Clinical Cases》 SCIE 2022年第2期502-510,共9页
Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in dif... Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in different types of tibial plateau fractures.Violent trauma can lead to displaced fracture,serious soft tissue injury,and potentially,dislocation of the knee joint.Therefore,tibial plateau fractures are extremely unstable.AIM To assess the use of locking compression plate(LCP)+T-type steel plate for postoperative weight bearing and functional recovery of complex tibial plateau fractures.METHODS Ninety-seven patients with complex tibial plateau fractures who underwent surgery at our hospital were selected for retrospective study.Forty-nine patients had been treated with LCP+T-type steel plate limited internal fixation(study group),and 48 patients with bilateral ordinary steel plate support(control group).The operation process index,postoperative rehabilitation related index,Rasmussen score of the knee joint,tibial plateau varus angle(TPA),tibial plateau retroversion angle(PA),and surgical complications of the two groups were compared.RESULTS The operation time and intraoperative bone graft volume in the study group were lower than those in the control group(P<0.05).There were no significant differences in surgical bleeding,anterior external incision length,postoperative drainage,hospital stay duration,and fracture healing time between the groups(P>0.05).There was no significant difference in the TPA and PA angle between the groups immediately and 18 mo after surgery(P>0.05).At 12 mo after surgery,the Rasmussen scale score was higher in the study group than in the control group(P<0.05).There was no significant difference in the Rasmussen scale score at 18 mo after surgery,and the radiology score at 12 and 18 mo after surgery,between the two groups(P>0.05).The postoperative complication rate in the study group(3.77%)was lower than that in the control group(15.09%;P<0.05).CONCLUSION LCP+T-type steel plate internal fixation has advantages in terms of minimizing trauma and enabling early postoperative functional exercise,promoting functional recovery and lower limb weight-bearing,and reducing postoperative complications. 展开更多
关键词 Locking compression plate T-type steel plate COMPLEXITY tibial plateau fracture Functional recovery COMPLICATIONS
下载PDF
Therapeutic effect of two methods on avulsion fracture of tibial insertion of anterior cruciate ligament 被引量:6
15
作者 Hai-Ming Niu Qing-Chun Wang Rui-Zhao Sun 《World Journal of Clinical Cases》 SCIE 2022年第27期9641-9649,共9页
BACKGROUND The tibial stop of anterior cruciate ligament(ACL) is fan-shaped and attached to the medial groove in front of the intercondylar spine,which is located between the anterior horn of the medial and lateral me... BACKGROUND The tibial stop of anterior cruciate ligament(ACL) is fan-shaped and attached to the medial groove in front of the intercondylar spine,which is located between the anterior horn of the medial and lateral meniscus.The incidence of this fracture is low previously reported,which is common in children and adolescents.With the increase of sports injury and traffic injury and the deepening of understanding,it is found that the incidence of the disease is high at present.AIM To explore the difference between open reduction and internal fixation with small incision and high-intensity non-absorbable suture under arthroscopy in the treatment of tibial avulsion fracture of ACL.METHODS Seventy-six patients with tibial avulsion fracture of anterior cruciate ligament diagnosed and treated in Guanyun County People’s Hospital from April 2018 to June 2020 were retrospectively analyzed.According to the surgical methods,they were divided into group A(40 cases) and group B(36 cases).Patients in group A were treated with arthroscopic high-strength non-absorbable suture,and patients in group B were treated with small incision open reduction and internal fixation.The operation time,fracture healing time,knee joint activity and functional score before and after operation,and surgical complications of the two groups were compared.RESULTS The operation time of group A was higher than that of group B,and the difference was statistically significant(P < 0.05);the fracture healing time of group A was compared with that of group B,and the difference was not statistically significant(P > 0.05);The knee joint function activity was compared between two groups before operation,3 mo and 6 mo after operation,and the difference was not statistically significant(P > 0.05);the knee joint function activity of group A and group B at 3 mo and 6 mo after operation was significantly higher than that before operation(P < 0.05);the limp,support,lock,instability,swelling,upstairs,squatting,pain and Lysholm score were compared between the two groups before and 6 mo after operation,and the difference was not statistically significant(P > 0.05);the scores of limp,support,lock,instability,swelling,upstairs,squatting,pain and Lysholm in group A and group B at 6 mo after operation were significantly higher than those before operation(P > 0.05);the surgical complication rate of group A was 2.63%,which was lower than 18.42% of group B,and the difference was statistically significant(P > 0.05).CONCLUSION Both small incision open reduction and internal fixation and arthroscopic high-strength nonabsorbable sutures can achieve good results in the treatment of anterior cruciate ligament tibial avulsion fractures.The operation time of arthroscopic high-strength non-absorbable sutures is slightly longer,but the complication rate is lower. 展开更多
关键词 Small incision Anterior cruciate ligament Open reduction and internal fixation ARTHROSCOPY Non-absorbable sutures Anterior cruciate ligament tibial avulsion fracture
下载PDF
Comparison between computed tomography and magnetic resonance imaging in clinical diagnosis and treatment of tibial platform fractures 被引量:2
16
作者 Xin-Ding Liu Hai-Bo Wang +2 位作者 Tie-Cheng Zhang Yong Wan Chu-Zhen Zhang 《World Journal of Clinical Cases》 SCIE 2020年第18期4067-4074,共8页
BACKGROUND Tibial plateau fracture is one of the common fracture types.It occurs mainly in teenagers and is usually caused by a fall.After the occurrence of fracture,knee swelling,pain,limited activity,etc.greatly aff... BACKGROUND Tibial plateau fracture is one of the common fracture types.It occurs mainly in teenagers and is usually caused by a fall.After the occurrence of fracture,knee swelling,pain,limited activity,etc.greatly affect the patient’s exercise habits and lifestyle.X-ray,computed tomography(CT)and magnetic resonance imaging(MRI)were used in this examination.X-rays are relatively new and easy to operate.However,there are some errors in the observation of fracture collapse and fracture displacement.In recent years,CT and MRI have been actively used to diagnose various types of clinical fractures.They have more diagnostic power than X-ray film.However,some scholars believe that CT is also prone to errors in clinical application.The volume effect leads to missed diagnosis and misdiagnosis in some cases,while the multidirection scanning of MRI technology can effectively overcome the shortcomings of CT.To facilitate the selection of clinical examination regimens,this study further observed the diagnostic ability of these two regimens in the diagnosis of tibial plateau fractures.AIM To explore the value of nuclear MRI and CT in the clinical diagnosis of tibial plateau fractures.METHODS A total of 120 patients with tibial plateau fractures admitted from September 2017 to August 2019 were included.All patients were examined by nuclear MRI and CT scanning.The results were sent to senior physicians in our hospital to complete the diagnosis.RESULTS Nuclear magnetic resonance showed the same effects as CT in four aspects:fracture displacement,bone defect,fracture site and fracture comminution.There was no significant difference in the score data(P>0.05).Nuclear magnetic resonance and CT tended to be consistent in the B3,C2 and C3 fracture diagnosis coincidence rate,combined injury detection rate and fracture detection rate.The diagnostic coincidence rate of type B1,B2 and C1 fractures and the accuracy rate of overall fracture classification indicated that the MRI technique was significantly better than that of CT(P>0.05).CONCLUSION MRI and CT have good diagnostic typing in the diagnosis of tibial plateau fractures,but MRI is more accurate and may be preferred. 展开更多
关键词 Nuclear magnetic resonance technology tibial plateau fracture Diagnostic compliance Comparative study fracture classification Diagnostic compliance
下载PDF
Correlative Factors Research of Tibial Shaft Fracture with Ipsilateral Posterior Malleolar Crack Fractures
17
作者 Binbin Tang Quan Liu +2 位作者 Zhen Li Gaobo Shen Lianguo Wu 《Journal of Integrative Medicine(双语)》 2020年第2期12-16,共5页
Background:Missed diagnosis rate of spiral tibia shaft fracture with posterior malleolus crack fracture(PMCF)is high in the clinical.However,the mechanism and related factors of fracture are still unclear.Moreover,PMC... Background:Missed diagnosis rate of spiral tibia shaft fracture with posterior malleolus crack fracture(PMCF)is high in the clinical.However,the mechanism and related factors of fracture are still unclear.Moreover,PMCF has been observed in other types of tibial shaft fractures.Objective:To explore the correlative factors of tibial shaft fracture with ipsilateral PMCF,decrease the rate of clinical missed diagnosis,strengthen the effective fixation of PMCF,and reduce the incidence of traumatic arthritis.Methods:From September 2014 to May 2019,we collected 137 tibiofibular fracture.Only 68 cases involved in ankle joint CT examination and were retrospectively analyzed.The patients were divided into posterior malleolus group(30 cases)and non-posterior malleolus group(38 cases)according to whether come up PMCF or not.The posterior malleolus group contained 24 males and 6 females,27-77(47.57±11.79)years old,the non-posterior malleolus group contained 23 males and 15 females,18-85(48.71±13.84)years old.The gender,age,location,fibula fracture and tibial shaft fracture classification were observed for univariate and multivariate analysis.Results:The probability of PMCF was higher with right tibial shaft fracture(OR=3.6995%CI:1.13-12.08 P<0.05);the probability of PMCF following distal fibular fracture was higher than that without fibular fracture(OR=11.3695%CI:1.72-75.05 P<0.05);the probability of PMCF with type A tibial shaft fracture was higher than type C(OR=4.8295%CI:1.19-19.58 P<0.05).Conclusion:Right type A tibial shaft fracture accompanied by distal fibular fracture are very important factors related to PMCF,which needs highly attention to avoid clinical missed diagnosis. 展开更多
关键词 tibial shaft fracture Posterior malleolus crack fracture Classification Fibula fracture
下载PDF
Analysis of therapeutic effect of traditional medicine combined with western medicine on avulsion fracture of tibial spine
18
作者 高广升 廉永云 《中国组织工程研究与临床康复》 CAS CSCD 2001年第18期148-149,共1页
关键词 Analysis of therapeutic effect of traditional medicine combined with western medicine on avulsion fracture of tibial spine
下载PDF
MIPPO technique and LCP internal fixation for open tibial shaft fractures
19
作者 邹海兵 《外科研究与新技术》 2011年第2期107-107,共1页
Objective To explore the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) technique and locking compression plate (LCP) for open tibial shaft fractures.Methods From March 2005 to May 2009,16 ca... Objective To explore the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) technique and locking compression plate (LCP) for open tibial shaft fractures.Methods From March 2005 to May 2009,16 cases with open tibial 展开更多
关键词 MIPPO technique and LCP internal fixation for open tibial shaft fractures LCP
下载PDF
PERCUTANEOUS REDUCTION AND STABILIZATION OF COMPLEX TIBIAL PLATEAU FRACTURES
20
作者 刘国平 杜靖远 《Chinese Medical Sciences Journal》 CAS CSCD 1997年第3期184-188,共5页
Mechanical traction and percutaneous reduction by leverage and fixation by a bilateral groove externalfixator were performed on 23 patients with complex tibial plateau fractures involving a depressed and splitfragment... Mechanical traction and percutaneous reduction by leverage and fixation by a bilateral groove externalfixator were performed on 23 patients with complex tibial plateau fractures involving a depressed and splitfragments. The fixator is composed of two long groove frames, three to five nuts, hooked bolts and Stein-manns pins.All fractures united in good position in three months with no incision (only pinpricks), llttle operativetrauma and no significant complications but pintract infection, and the flexion-extension range of kneemovement was excllent in all patients, so that this technique is particularly advisable for complex tibialplateau fractures. 展开更多
关键词 tibial plateau fracture external fixation
全文增补中
上一页 1 2 3 下一页 到第
使用帮助 返回顶部