This paper presents an integrated relay and its associated protection scheme for power transmission lines.The concept of integrated protection is firstly introduced,in which a centralized protection system or relay pr...This paper presents an integrated relay and its associated protection scheme for power transmission lines.The concept of integrated protection is firstly introduced,in which a centralized protection system or relay provides the protection for multiple power plants or a substation.A novel integrated protection relay based on the combination of a number of protection principles is described.In the proposed scheme,the specially designed protection relays are installed at each substation of a network and are responsible for the protection of every line section connected to the substation busbar.The combined algorithms with multiple settings are implemented into the relay to cover all the protected line sections.Simulation studies show that the proposed protection scheme is able to produce desirable performance and may offer many advantages over the existing one and great potential for future applications.展开更多
Open phase in three phase induction motors is a common fault that can occur as a result of a fuse blowing or a pro- tective device failing on one phase of the motor. This paper introduces a new method,which is based o...Open phase in three phase induction motors is a common fault that can occur as a result of a fuse blowing or a pro- tective device failing on one phase of the motor. This paper introduces a new method,which is based on the transient mea- surement and can distinguish the fault of one phase connecting ground. The method has been proved to be in correspondence with the simulation results by Matlab and LabVIEW in practice, The method has merits of simplicity, accuracy and ease of USe.展开更多
For AC transmission lines connected to an LCC-HVDC inverter station,commutation failure can lead to the wrong operation of traditional protection.To solve the problem,this paper proposes a fast protection scheme using...For AC transmission lines connected to an LCC-HVDC inverter station,commutation failure can lead to the wrong operation of traditional protection.To solve the problem,this paper proposes a fast protection scheme using transient information from one end of the AC line.The boundary frequency characteristics of the AC line connected to LCC-HVDC inverter are analyzed first.This reveals the existence of significant attenuation on both high frequency signals and some specific frequency signals.Based on the boundary characteristics,a novel boundary protection principle utilizing a backward traveling wave is then proposed.A PSCAD/EMTDC simulation model of a±800 kV LCC-HVDC and 500 kV AC transmission system is established,and different fault cases are simulated.The simulation results prove that the novel protection principle is immune to commutation failure,fault resistance and fault type.展开更多
Model-based control shows promising potential for engine performance improve-ment and future aero-propulsion requirements.In this paper,an auto-updating thrust variation mitigation(AuTVM)control approach using on-boar...Model-based control shows promising potential for engine performance improve-ment and future aero-propulsion requirements.In this paper,an auto-updating thrust variation mitigation(AuTVM)control approach using on-board model strategies is proposed for gas tur-bine aero-engines under in-service degradation effects,which aims at active thrust regulation and acceleration protection in a simultaneous way.The AuTVM control is integrated with an on-line block,based on a reliable on-board engine model,and an off-line part for the periodical update of control parameters via post-flight engine monitoring data.The core feature of the AuTVM control is a set of auto-updating loops within the on-line part,including thrust regu-lation loop,surge margin loop,turbine entry temperature loop,and the steady loop,whose con-trol parameters are periodically adjusted with increasingflight cycles.Meanwhile,an industrial sensor-based baseline controller and two tailored model-based controllers,i.e.,a thrust variation mitigation(TVM)controller withfixed gains and a self-enhancing active transient protection(SeATP)controller with pro-active transient protection and passive thrust control,are also developed as comparison bases.Numerical simulations for idle to full-power acceleration tests are carried on a validated aero-thermal turbofan engine model using publicly available degra-dation data.Simulation results demonstrate that both new engines and severely degraded en-gines regulated by the AuTVM controller show significant thrust response enhancement,compared to the baseline controller.Moreover,thrust variation at the maximum steady state of degraded engines,which exists within the SeATP controller and the baseline controller,is suppressed by the proposed AuTVM controller.Robustness analysis against degradation uncer-tainties and sensor accuracy confirms that the AuTVM controller owns a closer maximum steady-state thrust distribution to the desired value than those of the SeATP and the baseline controller while utilizing transient margins of controlled engines more effectively.Hence,the control performance of the AuTVM controller for in-service engines is guaranteed.展开更多
基金National Natural Science Foundation of China(No.50077011 and 50377019)National Basic Research Project("973"Project No.2004CB217906).
文摘This paper presents an integrated relay and its associated protection scheme for power transmission lines.The concept of integrated protection is firstly introduced,in which a centralized protection system or relay provides the protection for multiple power plants or a substation.A novel integrated protection relay based on the combination of a number of protection principles is described.In the proposed scheme,the specially designed protection relays are installed at each substation of a network and are responsible for the protection of every line section connected to the substation busbar.The combined algorithms with multiple settings are implemented into the relay to cover all the protected line sections.Simulation studies show that the proposed protection scheme is able to produce desirable performance and may offer many advantages over the existing one and great potential for future applications.
文摘Open phase in three phase induction motors is a common fault that can occur as a result of a fuse blowing or a pro- tective device failing on one phase of the motor. This paper introduces a new method,which is based on the transient mea- surement and can distinguish the fault of one phase connecting ground. The method has been proved to be in correspondence with the simulation results by Matlab and LabVIEW in practice, The method has merits of simplicity, accuracy and ease of USe.
基金supported by the National Key R&D Program of China(2016YFB0900603)the Technology Projects of State Grid Corporation of China(52094017000 W).
文摘For AC transmission lines connected to an LCC-HVDC inverter station,commutation failure can lead to the wrong operation of traditional protection.To solve the problem,this paper proposes a fast protection scheme using transient information from one end of the AC line.The boundary frequency characteristics of the AC line connected to LCC-HVDC inverter are analyzed first.This reveals the existence of significant attenuation on both high frequency signals and some specific frequency signals.Based on the boundary characteristics,a novel boundary protection principle utilizing a backward traveling wave is then proposed.A PSCAD/EMTDC simulation model of a±800 kV LCC-HVDC and 500 kV AC transmission system is established,and different fault cases are simulated.The simulation results prove that the novel protection principle is immune to commutation failure,fault resistance and fault type.
基金supported by China National Postdoctoral Program for Innovative Talents (Grant No.:BX20220373)the Fundamental Research Funds for the Central Universities (Grant No.:YWF-23-Q-1067)Young Elite Scientists Sponsorship Program by BAST (Grant No.:BYESS2023081).
文摘Model-based control shows promising potential for engine performance improve-ment and future aero-propulsion requirements.In this paper,an auto-updating thrust variation mitigation(AuTVM)control approach using on-board model strategies is proposed for gas tur-bine aero-engines under in-service degradation effects,which aims at active thrust regulation and acceleration protection in a simultaneous way.The AuTVM control is integrated with an on-line block,based on a reliable on-board engine model,and an off-line part for the periodical update of control parameters via post-flight engine monitoring data.The core feature of the AuTVM control is a set of auto-updating loops within the on-line part,including thrust regu-lation loop,surge margin loop,turbine entry temperature loop,and the steady loop,whose con-trol parameters are periodically adjusted with increasingflight cycles.Meanwhile,an industrial sensor-based baseline controller and two tailored model-based controllers,i.e.,a thrust variation mitigation(TVM)controller withfixed gains and a self-enhancing active transient protection(SeATP)controller with pro-active transient protection and passive thrust control,are also developed as comparison bases.Numerical simulations for idle to full-power acceleration tests are carried on a validated aero-thermal turbofan engine model using publicly available degra-dation data.Simulation results demonstrate that both new engines and severely degraded en-gines regulated by the AuTVM controller show significant thrust response enhancement,compared to the baseline controller.Moreover,thrust variation at the maximum steady state of degraded engines,which exists within the SeATP controller and the baseline controller,is suppressed by the proposed AuTVM controller.Robustness analysis against degradation uncer-tainties and sensor accuracy confirms that the AuTVM controller owns a closer maximum steady-state thrust distribution to the desired value than those of the SeATP and the baseline controller while utilizing transient margins of controlled engines more effectively.Hence,the control performance of the AuTVM controller for in-service engines is guaranteed.