期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Repeatability and agreement of CCT measurement in myopia using entacam and ultrasound pachymetry 被引量:3
1
作者 Yong-Heng Luo, Xuan-Chu Duan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第3期329-333,共5页
AIM: To evaluate the repeatability of central corneal thickness (CCT) measurement by entacam, and agreement of CCT measured by Pentacam and ultrasound pachymetry (USP) in Chinese myopia. Thereby investigate the possib... AIM: To evaluate the repeatability of central corneal thickness (CCT) measurement by entacam, and agreement of CCT measured by Pentacam and ultrasound pachymetry (USP) in Chinese myopia. Thereby investigate the possibility of Pentacam as a substitute for USP in CCT measurement before refractive surgery. The effects of corneal curvature measured by Pentacam on CCT were also evaluated. METHODS: One hundred and forty-eight right eyes of 148 individual with myopia were included in this study. Three successive Pentacam CCT measurements followed by 10 successive ultrasound pachymetry were carried out in the 148 eyes. Mean of CCT taken by each device was calculated for comparison. According to the CCT measured by USP, all the 148 eyes were divided into 3 groups: <520 mu m, 520-560 mu m, >560 mu m. For all eyes and each group the CCT obtained by Pentacam and USP were compared. Anterior corneal curvature of the 148 eyes was also adopted for correlation analysis with CCT obtained by ultrasound pachymetry. In addition, CCT measurement using 60 random selected Scheimpflug images was performed by 3 skilled investigators at different time, and this was repeated for 3 times by a forth investigator to assess repeatability of Pentacam CCT measurement using Scheimpflug images. RESULTS: Intraclass correlation coefficient (ICC) analysis revealed high intraobserver repeatability (ICC=0.994, F=158.60, P<0.001) for CCT measurement by Pentacam. The interobserver (ICC=0.998, F =494.73, P <0.001) and intraobserver (ICC=0.997, F=383.98, P<0.001) repeatability for Pentacam CCT measurements using Scheimpflug images were also excellent. There was high positive correlation between the CCT values measured by Pentacam and ultrasound pachymetry (r=0.963, P<0.001). Bland-altman plots showed that the Pentacam underestimate the CCT by 8.02 mu m compared with ultrasouond pachymetry.The differences between Pentacam and USP increased as the CCT readings by USP increased (Pentacam vs USP: slope=-0.04, P< 0.05). The 95% upper and lower limits of agreement between CCT values obtained from the two devices were +9. 33 mu m and -25.37 mu m. No significant association could be found between CCT and anterior corneal curvature. CONCLUSION: Inter- and intraobserver variability for CCT measurements by Pentacam was considerably below clinically significant levels. CCT of myopia obtained by Scheimpflug camera, Pentacam, were highly correlated to that by ultrasound pachymetry. However, the values obtained are not directly interchangeable between Pentacam and ultrasound pachymetry as the 95% limits of agreement are relatively wide. Pentacam can be a useful instrument for measuring CCT in candidates to refractive surgery in clinic. 展开更多
关键词 PENTACAM central corneal thickness ultrasound pachymetry REPEATABILITY AGREEMENT
下载PDF
Sirius Scheimpflug-Placido versus. ultrasound pachymetry for central corneal thickness: meta-analysis
2
作者 Yili Jin Colm McAlinden +8 位作者 Yong Sun Daizong Wen Yiran Wang Jinjin Yu Ke Feng Benhao Song Qinmei Wang Shihao Chen Jinhai Huang 《Eye and Vision》 SCIE CSCD 2023年第4期1-11,共11页
Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound ... Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was-11.26μm with a 95%confidence interval(CI)(-16.92μm,-5.60μm).The heterogeneity Was IP=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference. 展开更多
关键词 META-ANALYSIS Central corneal thickness Scheimpflug-Placido topographer ultrasound pachymetry
原文传递
Sirius Scheimpflug–Placido versus ultrasound pachymetry for central corneal thickness:meta-analysis 被引量:2
3
作者 Yili Jin Colm McAlinden +8 位作者 Yong Sun Daizong Wen Yiran Wang Jinjin Yu Ke Feng Benhao Song Qinmei Wang Shihao Chen Jinhai Huang 《Eye and Vision》 SCIE CSCD 2021年第1期36-46,共11页
Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound ... Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was−11.26μm with a 95%confidence interval(CI)(−16.92μm,−5.60μm).The heterogeneity was I^(2)=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference. 展开更多
关键词 META-ANALYSIS Central corneal thickness Scheimpflug-Placido topographer ultrasound pachymetry
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部