期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
A hybrid ventilation scheme applied to bidirectional excavation tunnel construction with a long inclined shaft
1
作者 YANG Wei-chao WANG Jian +3 位作者 DENG E LIU Yi-kang LUO Lu-sen YANG Jia 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第9期3187-3205,共19页
The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the h... The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the hybrid ventilation system applied in bidirectional excavation tunnels with a long inclined shaft,this study has established a full-scale computational fluid dynamics model based on field tests,the Poly-Hexcore method,and the sliding mesh technique.The distribution of wind speed,temperature field,and CO in the tunnel are taken as indices to compare the ventilation efficiency of three ventilation systems(duct,duct-ventilation shaft,duct–ventilated shaft-axial fan).The results show that the hybrid ventilation scheme based on duct-ventilation shaft–axial fan performs the best among the three ventilation systems.Compared to the duct,the wind speed and cooling rate in the tunnel are enhanced by 7.5%–30.6%and 14.1%–17.7%,respectively,for the duct-vent shaft-axial fan condition,and the volume fractions of CO are reduced by 26.9%–73.9%.This contributes to the effective design of combined ventilation for bidirectional excavation tunnels with an inclined shaft,ultimately improving the air quality within the tunnel. 展开更多
关键词 bidirectional excavation tunnel inclined shaft hybrid ventilation scheme computational fluid dynamics ventilation efficiency
下载PDF
Application of ventilation management programs for improved mine safety 被引量:6
2
作者 De Souza Euler 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2017年第4期647-650,共4页
The purpose of ventilation management systems is to ensure the health and safety of underground workers by creating and incorporating structured plans, procedures and processes on the day-to-day operations of the mine... The purpose of ventilation management systems is to ensure the health and safety of underground workers by creating and incorporating structured plans, procedures and processes on the day-to-day operations of the mine ventilation system. The application of ventilation management programs consists of audit, verification, and corrective action procedures to:(1) ensure adherence to regulatory standards,or to(2) return to compliance and safety standards when an upset condition arises. This paper describes how a ventilation management program can be developed and implemented to ensure regulation compliance, to increase safety, to improve operational efficiency and to reduce the operating costs of an operating mine. Two case applications are presented in this paper. The first case is presented to demonstrate use of a ventilation management program in response to a site inspection and audit, with follow-up application of corrective actions. The second case application describes how air quality conditions has been substantially improved with the development and implementation of a ventilation management program for an operating underground hard rock mine. 展开更多
关键词 Mine ventilation ventilation management Air quality ventilation efficiency
下载PDF
Adaptive Wall-Based Attachment Ventilation:A Comparative Study on Its Effectiveness in Airborne Infection Isolation Rooms with Negative Pressure 被引量:3
3
作者 Ying Zhang Ou Han +4 位作者 Angui Li Li’an Hou Thomas Olofsson Linhua Zhang Wenjun Lei 《Engineering》 SCIE EI 2022年第1期130-137,共8页
The transmission of coronavirus disease 2019(COVID-19)has presented challenges for the control of the indoor environment of isolation wards.Scientific air distribution design and operation management are crucial to en... The transmission of coronavirus disease 2019(COVID-19)has presented challenges for the control of the indoor environment of isolation wards.Scientific air distribution design and operation management are crucial to ensure the environmental safety of medical staff.This paper proposes the application of adaptive wall-based attachment ventilation and evaluates this air supply mode based on contaminants dispersion,removal efficiency,thermal comfort,and operating expense.Adaptive wall-based attachment ventilation provides a direct supply of fresh air to the occupied zone.In comparison with a ceiling air supply or upper sidewall air supply,adaptive wall-based attachment ventilation results in a 15%–47%lower average concentration of contaminants,for a continual release of contaminants at the same air changes per hour(ACH;10 h^(-1)).The contaminant removal efficiency of complete mixing ventilation cannot exceed 1.For adaptive wall-based attachment ventilation,the contaminant removal efficiency is an exponential function of the ACH.Compared with the ceiling air supply mode or upper sidewall air supply mode,adaptive wall-based attachment ventilation achieves a similar thermal comfort level(predicted mean vote(PMV)of0.1–0.4;draught rate of 2.5%–6.7%)and a similar performance in removing contaminants,but has a lower ACH and uses less energy. 展开更多
关键词 ventilation efficiency Air change rate COVID-19 Attachment ventilation Air distribution Isolation ward
下载PDF
Air Flow Prediction and Evaluation of Ventilation Effectiveness with Different Zonal Configurations
4
作者 Nasreddine Guerfala Hachimi Fellouah +1 位作者 Ahmed Daoud Nicolas Galanis 《Journal of Energy and Power Engineering》 2013年第2期277-282,共6页
This paper proposes a numerical method for the study of ventilation efficiency in buildings. The developed model is validated with the experimental results of Nielsen who tested the isothermal flow in a scaled model o... This paper proposes a numerical method for the study of ventilation efficiency in buildings. The developed model is validated with the experimental results of Nielsen who tested the isothermal flow in a scaled model of a ventilated room. A zonal method is used to predict airflow patterns in the same ventilated room. The different equations governing the flow in the room were coded in Matlab for different operating conditions, different zonal configurations of the room and different number of cells (control volumes). The efficiency of the ventilation was determined by calculating the number of ACH (air changes per hour) for each cell. The present results show the importance of the inlet air flow rate, the space resolution and the jet inlet dimensions on the determination of air quality. 展开更多
关键词 Air flow zonal method numerical simulation ventilated room ventilation efficiency.
下载PDF
Ambient formaldehyde concentrations in summer in 30 Chinese cities and impacts on air cleaning of built environment
5
作者 Shuolin Qiu Zirui He +11 位作者 Guangdong Liu Zhen Ding Zhongming Bu Jianping Cao Wenjing Ji Wei Liu Chunxiao Su Xinke Wang Fan Liu Ting Li Hua Qian Cong Liu 《Energy and Built Environment》 EI 2024年第4期493-499,共7页
Formaldehyde is an important carcinogen commonly found indoors.Its indoor sources have been intensively in-vestigated.But study on outdoor formaldehyde concentration,which is potentially an important source to indoors... Formaldehyde is an important carcinogen commonly found indoors.Its indoor sources have been intensively in-vestigated.But study on outdoor formaldehyde concentration,which is potentially an important source to indoors,remains scarce.This study attempts to characterize temporal and spatial distribution of the atmospheric formalde-hyde concentration in Chinese cities.Diurnal variation of ambient formaldehyde was examined in 6 cities and peak hours were identified between 12:00 pm and 3:00 pm.Consequently,outdoor formaldehyde concentrations were measured in the peak hours in 30 cities during the summer months of Jul.-Aug.,2022.The formaldehyde concentrations in the peak hours fell into a range of 0.005-0.087 mg/m^(3)(median value is 0.027 mg/m^(3)),87.7%of which have exceeded the chronic reference exposure criteria of 0.009 mg/m^(3) set by Office of Environmental Health Hazard Assessment.Health risk analysis suggests that exposure to ambient formaldehyde could cause a median carcinogenic risk of 1.9×10^(−5)(3.17×10^(−6)-6.13×10^(−5)),higher than threshold limit of 10−6.Pearson correlation analysis of the 30 cities shows that ambient summertime atmospheric formaldehyde concentrations of the city are positively correlated with its Gross Domestic Product(r=0.48).We also found that the outdoor formaldehyde concentrations in urban areas(median:0.017 mg/m^(3))is slightly higher than those in suburban areas(median:0.013 mg/m^(3)).Results here prove that outdoor formaldehyde is ubiquitous in Chinese cities and reduces effectiveness of ventilation in dilution indoor concentrations.Neglecting it would underestimate air cleaner capacity needed by a factor of about two.It should be accounted for in health analysis and air quality engineering control design of built environment in the future. 展开更多
关键词 Atmospheric formaldehyde Temporal distribution Health risk ventilation efficiency
原文传递
Effect of source location on particle dispersion in displacement ventilation rooms 被引量:7
6
作者 Ke Zhong Yanming Kang Youjun Wang 《Particuology》 SCIE EI CAS CSCD 2008年第5期362-368,共7页
A proposed computer model for predicting aerosol particle dispersion in indoor spaces was validated with experimental data found in the literature, and is then used to study the effect of the area and point source loc... A proposed computer model for predicting aerosol particle dispersion in indoor spaces was validated with experimental data found in the literature, and is then used to study the effect of the area and point source locations on particle dispersion in displacement ventilation (DV) rooms. The results show that aerosol source location has a strong impact on the spatial distribution and removal rate of indoor particles. Particle removal performance depends strongly on ventilation efficiency and particle deposition rate on indoor surfaces. Important consideration for both relative ventilation efficiency and deposition rate consists of the position of the aerosol source relative to the main airflow pattern and the occupied zone. 展开更多
关键词 Particle dispersion Displacement ventilation Source location ventilation efficiency Deposition efficiency
原文传递
On the effects of urban-like intersections on ventilation and pollutant dispersion
7
作者 Xin Guo Riccardo Buccolieri +4 位作者 Zhi Gao Mingjie Zhang Tong Lyu Liyan Rui Jialei Shen 《Building Simulation》 SCIE EI CSCD 2022年第3期419-433,共15页
Focusing on the effect of street morphology on the ventilation efficiency,this paper presents 3D computational fluid dynamics(CFD)simulations of airflow and pollutant dispersion within urban-like three-way intersectio... Focusing on the effect of street morphology on the ventilation efficiency,this paper presents 3D computational fluid dynamics(CFD)simulations of airflow and pollutant dispersion within urban-like three-way intersections,four-way intersections and roundabouts.The steady-state Reynolds-averaged Navier-Stokes(RANS)k-εturbulence model is adopted and eight directions of the approaching wind are considered.The ventilation efficiency is evaluated using the ventilation indices purging flow rate(PFR)and the net escape velocity(NEV).Results show the sensitivity of the ventilation efficiency to the type of intersection,to the wind direction and to the number of branches.Specifically,the ventilation efficiency of the investigated three-way intersections is found to be better than that of the other intersections,especially when the angle between the streets is large,while that of roundabouts is also considerable,even with a similar average wind velocity,among the cases evaluated in this paper.Further,the influence of the wind direction for the three-way and four-way intersections is greater than that on roundabouts.Studies on the ventilation efficiency at urban intersections are not common in the literature and this work may help urban planners to better design such hub nodes of urban traffic,where traffic-related pollutants are not easily dispersed,thus avoiding harm to the health of pedestrians and surrounding residents. 展开更多
关键词 urban-like intersections ventilation efficiency CFD simulations traffic-related pollutants
原文传递
Efficacy of coupling heat recovery ventilation and fan coil systems in improving the indoor air quality and thermal comfort condition
8
作者 Aminhossein Jahanbin 《Energy and Built Environment》 2022年第4期478-495,共18页
Mechanical Ventilation with Heat Recovery(MVHR)systems are gaining increasing interest in buildings with low energy demand,for improvement of the Indoor Air Quality(IAQ)and reduction of the ventilation energy loss.In ... Mechanical Ventilation with Heat Recovery(MVHR)systems are gaining increasing interest in buildings with low energy demand,for improvement of the Indoor Air Quality(IAQ)and reduction of the ventilation energy loss.In retrofitted buildings,MVHRs are often integrated with an additional air heater to cover space heating demand.Hence,evaluation of the interactions between MVHR and heat emitter,and their effects on indoor airflow characteristics is of significant importance.The present study aims to investigate effects of a combined MVHR-fan-coil system in heating mode on IAQ and thermal comfort parameters inside a retrofitted room,by means of a computational fluid dynamic(CFD)code.The proposed CFD model is validated by comparing the numerical results with experimental data.The results yielded by numerical simulations allow evaluating the indoor environmental quality characteristics as well as addressing the MVHR and fan coil interactions.The results indicate that the airflow discharged from the fan coil could have a significant impact on the age of the air;while it provides a desirable thermal comfort condition within the room,it may hinder to some extent delivery of the fresh air to the occupied zone due to creation of counterflow fields.Furthermore,it is shown that although increasing the fan speed(ON mode)would slightly enhance the air change efficiency,the OFF mode yields not only a better distribution of the fresh air but also a higher ventilation efficiency than when fan coil operates. 展开更多
关键词 Heat recovery ventilation Indoor air quality Thermal comfort ventilation efficiency Gaseous contaminants
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部