This study evaluated the efficacy and safety of "J"-shaped uterine incision for caesarean section for patients diagnosed with placenta previa. A total of 55 consecutive cases of placenta previa treated in Union Hosp...This study evaluated the efficacy and safety of "J"-shaped uterine incision for caesarean section for patients diagnosed with placenta previa. A total of 55 consecutive cases of placenta previa treated in Union Hospital were retrospectively analyzed over a period of two years and 10 months. The subjects were divided into two groups with respect to the uterine incision. Twenty-four pregnant women with placenta previa who were indicated for caesarean section underwent the procedure using a new "J"-shaped uterine incision and 31 pregnant women with placenta previa received caesarean section that used the traditional transverse incision. The two groups were compared in terms of operation time, estimated blood loss, infant expulsion time, exhaust time and postoperative recovery. Meanwhile, comparison was also made in neonatal clinical data between the two groups. Compared with the "J"-shaped incision group, the traditional incision group had a lower Apgar scores (P〈0.05). However, there existed no statistically significant differences in the overall time of operation and postoperative period of breaking wind (P〉0.05). It is concluded that, with caesarean section for placenta previa patients, the "J"-shaped uterine incision significantly decreases intraoperative blood loss and facilitates the fetal delivery.展开更多
A new 4 H–SiC light triggered thyristor(LTT) with 7-shaped thin n-base doping profile is proposed and simulated using a two-dimensional numerical method. In this new structure, the bottom region of the thin n-base ...A new 4 H–SiC light triggered thyristor(LTT) with 7-shaped thin n-base doping profile is proposed and simulated using a two-dimensional numerical method. In this new structure, the bottom region of the thin n-base has a graded doping profile to induce an accelerating electric field and compensate for the shortcoming of the double-layer thin n-base structure in transmitting injected holes. In addition, the accelerating electric field can also speed up the transmission of photongenerated carriers during light triggering. As a result, the current gain of the top pnp transistor of the SiC LTT is further increased. According to the TCAD simulations, the turn-on delay time of the SiC LTT decreases by about 91.5% compared with that of previous double-layer thin n-base SiC LTT. The minimum turn-on delay time of the SiC LTT is only 828 ns,when triggered by 100 mW/cm^2 ultraviolet light. Meanwhile, there is only a slight degradation in the forward blocking characteristic.展开更多
BACKGROUND Robotic pancreaticoduodenectomy(RPD)can achieve similar surgical results to open and PD;however,RPD has a long learning curve and operation time(OT).To address this issue,we have summarized a surgical path ...BACKGROUND Robotic pancreaticoduodenectomy(RPD)can achieve similar surgical results to open and PD;however,RPD has a long learning curve and operation time(OT).To address this issue,we have summarized a surgical path to shorten the surgical learning curve and OT.AIM To investigate the effective learning curve of a“G”-shaped surgical approach in RPD for patients.METHODS A total of 60 patients,who received“G”-shaped RPD(GRPD)by a single surgeon in the First Hospital of Shanxi Medical University from May 2017 to April 2020,were included in this study.The OT,demographic data,intraoperative blood loss,complications,hospitalization time,and pathological results were recorded,and the cumulative sum(CUSUM)analysis was performed to evaluate the learning curve for GRPD.RESULTS According to the CUSUM analysis,the learning curve for GRPD was grouped into two phases:The early and late phases.The OT was 480±81.65 min vs 331±76.54 min,hospitalization time was 22±4.53 d vs 17±6.08 d,and blood loss was 308±54.78 mL vs 169.2±35.33 mL in the respective groups.Complications,including pancreatic fistula,bile leakage,reoperation rate,postoperative death,and delayed gastric emptying,were significantly decreased after this surgical technique.CONCLUSION GRPD can improve the learning curve and operative time,providing a new method for shortening the RPD learning curve.展开更多
To evaluate the retention properties of the novel ‘C'-shaped molar bands at a laboratory level. Resin-modified glass ionomer cement(RMGIC) was used as a luting agent for the novel C-shaped molar band. The mechanic...To evaluate the retention properties of the novel ‘C'-shaped molar bands at a laboratory level. Resin-modified glass ionomer cement(RMGIC) was used as a luting agent for the novel C-shaped molar band. The mechanical properties of the band were examined and the retention performance was characterized in the mesial, distal and vertical directions. A clinical trial was conducted using a spilt-mouth design on 50 patients. The novel C-shaped molar bands fit most molars without a repeated try-in process.The use of both nanoHA coating and RMGIC enhanced the tensile(8.00 ± 1.8 MPa) and shear strengths(27.17 ± 8.6 MPa) of the molar bands, leading to high retention in vertical, mesial and distal directions( p 〈 0.001). In clinical trials, the C-shaped molar bands had a failure rate(15%) comparable to that of traditional bands, and 93% of the failed bands demonstrated an adhesive remnant index score of 0, corroborating the observation that no luting agent residue remained on the tooth surface in most cases. The novel C-shaped molar bands appear to be a promising appliance that requires further clinical investigations, and may be used effectively in orthodontics.展开更多
In this letter,high power density AlGaN/GaN high electron-mobility transistors(HEMTs)on a freestanding GaN substrate are reported.An asymmetricΓ-shaped 500-nm gate with a field plate of 650 nm is introduced to improv...In this letter,high power density AlGaN/GaN high electron-mobility transistors(HEMTs)on a freestanding GaN substrate are reported.An asymmetricΓ-shaped 500-nm gate with a field plate of 650 nm is introduced to improve microwave power performance.The breakdown voltage(BV)is increased to more than 200 V for the fabricated device with gate-to-source and gate-to-drain distances of 1.08 and 2.92μm.A record continuous-wave power density of 11.2 W/mm@10 GHz is realized with a drain bias of 70 V.The maximum oscillation frequency(f_(max))and unity current gain cut-off frequency(f_(t))of the AlGaN/GaN HEMTs exceed 30 and 20 GHz,respectively.The results demonstrate the potential of AlGaN/GaN HEMTs on freestanding GaN substrates for microwave power applications.展开更多
Lumped element lowpass filter(LPF)for ultra-high frequency(UHF)radio frequency(RF)front-end system is presented based on multilayer liquid crystal polymer(LCP).The lumped element LPF can achieve miniaturization and on...Lumped element lowpass filter(LPF)for ultra-high frequency(UHF)radio frequency(RF)front-end system is presented based on multilayer liquid crystal polymer(LCP).The lumped element LPF can achieve miniaturization and one transmission zero on the stopband by the 8-shaped inductor.The lumped element LPF is fabricated on a 4-layer LCP substrate with a compact size of 9 mm×14 mm×0.193 mm.The measured cut off frequency of the lumped element LPF is 0.5 GHz with insertion loss(IL)less than 0.37 dB.Both measured and simulated results suggest that it is a possible candidate for the application of UHF RF front-end system.展开更多
基金supported by a grant from the National Natural Sciences Foundation of China (No. 30872776)
文摘This study evaluated the efficacy and safety of "J"-shaped uterine incision for caesarean section for patients diagnosed with placenta previa. A total of 55 consecutive cases of placenta previa treated in Union Hospital were retrospectively analyzed over a period of two years and 10 months. The subjects were divided into two groups with respect to the uterine incision. Twenty-four pregnant women with placenta previa who were indicated for caesarean section underwent the procedure using a new "J"-shaped uterine incision and 31 pregnant women with placenta previa received caesarean section that used the traditional transverse incision. The two groups were compared in terms of operation time, estimated blood loss, infant expulsion time, exhaust time and postoperative recovery. Meanwhile, comparison was also made in neonatal clinical data between the two groups. Compared with the "J"-shaped incision group, the traditional incision group had a lower Apgar scores (P〈0.05). However, there existed no statistically significant differences in the overall time of operation and postoperative period of breaking wind (P〉0.05). It is concluded that, with caesarean section for placenta previa patients, the "J"-shaped uterine incision significantly decreases intraoperative blood loss and facilitates the fetal delivery.
基金Project supported by the National Natural Science Foundation of China(Grant No.51677149)
文摘A new 4 H–SiC light triggered thyristor(LTT) with 7-shaped thin n-base doping profile is proposed and simulated using a two-dimensional numerical method. In this new structure, the bottom region of the thin n-base has a graded doping profile to induce an accelerating electric field and compensate for the shortcoming of the double-layer thin n-base structure in transmitting injected holes. In addition, the accelerating electric field can also speed up the transmission of photongenerated carriers during light triggering. As a result, the current gain of the top pnp transistor of the SiC LTT is further increased. According to the TCAD simulations, the turn-on delay time of the SiC LTT decreases by about 91.5% compared with that of previous double-layer thin n-base SiC LTT. The minimum turn-on delay time of the SiC LTT is only 828 ns,when triggered by 100 mW/cm^2 ultraviolet light. Meanwhile, there is only a slight degradation in the forward blocking characteristic.
基金Supported by Shanxi Provincial Science and Technology Department Social Development Fund,No.201903D321144.
文摘BACKGROUND Robotic pancreaticoduodenectomy(RPD)can achieve similar surgical results to open and PD;however,RPD has a long learning curve and operation time(OT).To address this issue,we have summarized a surgical path to shorten the surgical learning curve and OT.AIM To investigate the effective learning curve of a“G”-shaped surgical approach in RPD for patients.METHODS A total of 60 patients,who received“G”-shaped RPD(GRPD)by a single surgeon in the First Hospital of Shanxi Medical University from May 2017 to April 2020,were included in this study.The OT,demographic data,intraoperative blood loss,complications,hospitalization time,and pathological results were recorded,and the cumulative sum(CUSUM)analysis was performed to evaluate the learning curve for GRPD.RESULTS According to the CUSUM analysis,the learning curve for GRPD was grouped into two phases:The early and late phases.The OT was 480±81.65 min vs 331±76.54 min,hospitalization time was 22±4.53 d vs 17±6.08 d,and blood loss was 308±54.78 mL vs 169.2±35.33 mL in the respective groups.Complications,including pancreatic fistula,bile leakage,reoperation rate,postoperative death,and delayed gastric emptying,were significantly decreased after this surgical technique.CONCLUSION GRPD can improve the learning curve and operative time,providing a new method for shortening the RPD learning curve.
基金Funded by Department of Education,National Natural Science Foundation of China(No.81170960)Heilongjiang Province(No.11531204)+1 种基金Department of Health,Heilongjiang Province(No.2006-123)Youth Foundation of the Second Affiliated Hospital of Harbin Medical University(No.QN2006-13)
文摘To evaluate the retention properties of the novel ‘C'-shaped molar bands at a laboratory level. Resin-modified glass ionomer cement(RMGIC) was used as a luting agent for the novel C-shaped molar band. The mechanical properties of the band were examined and the retention performance was characterized in the mesial, distal and vertical directions. A clinical trial was conducted using a spilt-mouth design on 50 patients. The novel C-shaped molar bands fit most molars without a repeated try-in process.The use of both nanoHA coating and RMGIC enhanced the tensile(8.00 ± 1.8 MPa) and shear strengths(27.17 ± 8.6 MPa) of the molar bands, leading to high retention in vertical, mesial and distal directions( p 〈 0.001). In clinical trials, the C-shaped molar bands had a failure rate(15%) comparable to that of traditional bands, and 93% of the failed bands demonstrated an adhesive remnant index score of 0, corroborating the observation that no luting agent residue remained on the tooth surface in most cases. The novel C-shaped molar bands appear to be a promising appliance that requires further clinical investigations, and may be used effectively in orthodontics.
文摘In this letter,high power density AlGaN/GaN high electron-mobility transistors(HEMTs)on a freestanding GaN substrate are reported.An asymmetricΓ-shaped 500-nm gate with a field plate of 650 nm is introduced to improve microwave power performance.The breakdown voltage(BV)is increased to more than 200 V for the fabricated device with gate-to-source and gate-to-drain distances of 1.08 and 2.92μm.A record continuous-wave power density of 11.2 W/mm@10 GHz is realized with a drain bias of 70 V.The maximum oscillation frequency(f_(max))and unity current gain cut-off frequency(f_(t))of the AlGaN/GaN HEMTs exceed 30 and 20 GHz,respectively.The results demonstrate the potential of AlGaN/GaN HEMTs on freestanding GaN substrates for microwave power applications.
基金Supported by the Shaanxi Provincial Innovation Team Project(2020TD-019)the Xi'an Sciences Plan Project(21XJZZ0075)。
文摘Lumped element lowpass filter(LPF)for ultra-high frequency(UHF)radio frequency(RF)front-end system is presented based on multilayer liquid crystal polymer(LCP).The lumped element LPF can achieve miniaturization and one transmission zero on the stopband by the 8-shaped inductor.The lumped element LPF is fabricated on a 4-layer LCP substrate with a compact size of 9 mm×14 mm×0.193 mm.The measured cut off frequency of the lumped element LPF is 0.5 GHz with insertion loss(IL)less than 0.37 dB.Both measured and simulated results suggest that it is a possible candidate for the application of UHF RF front-end system.