Radiation protection programs aims to reduce the radiation dose to the lowest possible level under the Dose Limit (DL) limit by the national or international laws, while the dose monitoring programs working as scale u...Radiation protection programs aims to reduce the radiation dose to the lowest possible level under the Dose Limit (DL) limit by the national or international laws, while the dose monitoring programs working as scale used to evaluating the efficiency of these programs and tools. In this study, the average of the annual Eff dose for the intensive care units at Hamad General Hospital (HGH) is less than the 50% of DL. It was aiming also to evaluate the efficiency of the radiation safety requirements (especially the shielding Adequacy) for the non radiation workers at oncology centers, hence several monitors were installed in chosen locations outside the radiation treatment machine from 2007 to 2011.展开更多
AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected"real world"patients.METHODS In this single-c...AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected"real world"patients.METHODS In this single-centre study,consecutive patients in sinus rhythm underwent CCTA for suspected coronary artery disease(CAD)using a 320-row detector CT scanner.All patients underwent the standard CT acquisition protocol at our institute(Morriston Hospital)a combination of dose saving advances including prospective electrocardiogram-gating,automated tube current modulation,tube voltage reduction,heart rate reduction,and the most recent novel adaptive iterative dose reconstruction 3D(AIDR3D)algorithm.The cohort comprised real-world patients for routine CCTA who were not selected on age,body mass index,or heart rate.Subjective image quality was graded on a 4-point scale(4=excellent,1=non-diagnostic).RESULTS A total of 543 patients were included in the study with a mean body weight of 81±18 kg and a pre-scan mean heart rate of 70±11 beats per minute(bpm).When indicated,patients received rate-limiting medication with an oral beta-blocker followed by additional intravenous beta-blocker to achieve a heart rate below 65 bpm.The median effective radiation dose was 0.88 mSv(IQR,0.6-1.4 mSv)derived from a Dose Length Product of61.45 mGy.cm(IQR,42.86-100.00 mGy.cm).This also includes what we believe to be the lowest ever-reported radiation dose for a routine clinical CCTA(0.18 mSv).The mean image quality(SD)was 3.65±0.61,with a subjective image quality score of 3("good")or above for 93%of patient CCTAs.CONCLUSION Combining a low-dose scan protocol and AIDR3D with a 320-detector row CT scanner can provide high quality images at exceptionally low radiation dose in unselected patients being investigated for CAD.展开更多
BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resi...BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resistance such as ours,Maastricht VI guidelines suggest high dose amoxicillin dual therapy(HDADT)can be considered,subject to evidence for local efficacy.In this study we assess efficacy of HDADT therapy for H.pylori eradication in an Irish cohort.AIM To assess the efficacy of HDADT therapy for H.pylori eradication in an Irish cohort as both first line,and subsequent therapy for patients diagnosed with H.pylori.METHODS All patients testing positive for H.pylori in a tertiary centre were treated prospectively with HDADT(amoxicillin 1 g tid and esomeprazole 40 mg bid×14 d)over a period of 8 months.Eradication was confirmed with Urea Breath Test at least 4 wk after cessation of therapy.A delta-over-baseline>4%was considered positive.Patient demographics and treatment outcomes were recorded,analysed and controlled for basic demographics and prior H.pylori treatment.RESULTS One hundred and ninety-eight patients were identified with H.pylori infection,10 patients were excluded due to penicillin allergy and 38 patients refused follow up testing.In all 139 were included in the analysis,55%(n=76)were female,mean age was 46.6 years.Overall,93(67%)of patients were treatment-naïve and 46(33%)had received at least one previous course of treatment.The groups were statistically similar.Self-reported compliance with HDADT was 97%,mild side-effects occurred in 7%.There were no serious adverse drug reactions.Overall the eradication rate for our cohort was 56%(78/139).Eradication rates were worse for those with previous treatment[43%(20/46)vs 62%(58/93),P=0.0458,odds ratio=2.15].Age and Gender had no effect on eradication status.CONCLUSION Overall eradication rates with HDADT were disappointing.Despite being a simple and possibly better tolerated regime,these results do not support its routine use in a high dual resistance country.Further investigation of other regimens to achieve the>90%eradication target is needed.展开更多
Objective To identlfy the member of the caspase famlly proteases involved in Y-radiation-inducedapoptosis in HL-60 cells and to study the expression or the caspase gene in normal, apoptotic cells and in immortal tumor...Objective To identlfy the member of the caspase famlly proteases involved in Y-radiation-inducedapoptosis in HL-60 cells and to study the expression or the caspase gene in normal, apoptotic cells and in immortal tumor cells. Methods By using degenerate oligonucleotide primers encoding the highly conserved peptides that were present in all known caspases, we performed RT-PCR on poly(A)RNA from γ-radiation-induced apoptotic HL-6o cells.Caspase-3 mRNA in apoptotic HL-6o cells and in human tumor cell lines was analyzed by Northern blot. Results The amplified DNA fragment was identiried with caspase-3 cDNA by cloning and sequencing. The Northern blot analysis of caspase-3 mRNA of different human tumor cell lines showed that the caspase-3 gene transcript was more highly expressed in leukemia cell lines and the SH-SY5Y cell line than in HeLa and MCF-7 cells. It was more highly expressed in the radiation-induced apoptotic HL-6o cells than in control HL-6o cells. Conclusion These results indicated that caspase-3 was involved in γ-radiation-induced apoptosis in HL-6o cells. The high level of expression or caspase-3 may aid efforts to understand the insensitivity of some tumor cells to radlation, their inherent ability to survive, and apoptosis展开更多
Coronaviruses are a diverse group of viruses that infect both animals and humans.Even though the existence of coronavirus and its infection to humans is not new,the 2019-novel coronavirus(nCoV)caused a major burden to...Coronaviruses are a diverse group of viruses that infect both animals and humans.Even though the existence of coronavirus and its infection to humans is not new,the 2019-novel coronavirus(nCoV)caused a major burden to individuals and society i.e.,anxiety,fear of infection,extreme competition for hospitalization,and more importantly financial liability.The nCoV infection/disease diagnosis was based on non-specific signs and symptoms,biochemical parameters,detection of the virus using reverse-transcription polymerase chain reaction(RTPCR),and X-ray-based imaging.This review focuses on the consolidation of potentials of X-ray-based imaging modality[chest-X radiography(CXR)and chest computed tomography(CT)]and low-dose radiation therapy(LDRT)for screening,severity,and management of COVID-19 disease.Reported studies suggest that CXR contributed significantly toward initial rapid screening/diagnosis and CT-imaging to monitor the disease severity.The chest CT has high sensitivity up to 98%and low specificity for diagnosis and severity of COVID-19 disease compared to RT-PCR.Similarly,LDRT compliments drug therapy in the early recovery/Less hospital stays by maintaining the physiological parameters better than the drug therapy alone.All the results undoubtedly demonstrated the evidence that X-ray-based technology continues to evolve and play a significant role in human health care even during the pandemic.展开更多
Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quanti...Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quantitative and systematic analysis of data is necessary.Particularly,the FLASH effect response model to the dose or dose rate is still unclear.This study investigated the relationships between the FLASH effect and experimental parameters,such as dose,dose rate,and other factors by analyzing published in vivo experimental data from animal models.The data were modeled based on logistic regression analysis using the sigmoid function.The model was evaluated using prediction accuracy,receiver operating characteristic(ROC)curve,and area under the ROC curve.Results showed that the FLASH effect was closely related to the dose,mean dose rate,tissue type,and corresponding biological endpoints.The dose rate corresponding to a 50% probability of triggering cognitive protection in the brain was 45 Gy s^(-1).The dose rate corresponding to a 50% probability of triggering intestinal crypt survival and regeneration was 140 Gy s^(-1).For the skin toxicity effect,the dose corresponding to a 50% probability of triggering the FLASH effect was 24 Gy.This study helps to characterize the conditions underlying the FLASH effect and provides important information for optimizing experiments.展开更多
Background: World Health Organization recommends the implementation of contact tracing and Leprosy Post Exposure prophylaxis (LPEP) to interrupt the chain of transmission. To accelerate the uptake of this recommendati...Background: World Health Organization recommends the implementation of contact tracing and Leprosy Post Exposure prophylaxis (LPEP) to interrupt the chain of transmission. To accelerate the uptake of this recommendation, a cross-sectional study among contacts of leprosy patients was conducted to investigate the feasibility of integrating leprosy systematic contact tracing and post-exposure prophylaxis (PEP) into the routine leprosy control program. Methods: This was a mixed methods cross-sectional study. The study was implemented in Kumi, Ngora, Serere, Soroti, Budaka and Kibuku Districts. Results: The 45 enrolled index patients (97.8% of the registered) identified a total of 135 contacts, of which 134 (99·2%) consented and were screened. Among them, one new leprosy patient was identified and started on treatment with multidrug therapy (MDT). All the eligible contacts, received the prophylactic treatment with Single Dose Rifampicin (SDR). Overall, SDR was administered to 133(98.5% of the listed contacts) with no adverse event reported. Factors associated with successful contact investigation and management included: Involvement of index patients, health care workers during the contact screening and SDR A administration, counselling of the index patients and contacts by the health care works, LPEP being administered as Directly observed Therapy (DOT) among others. Results Interpretation: The integration of leprosy post-exposure prophylaxis with administration of SDR and contact tracing is feasible, generally accepted by the patient, their contacts and health workers and can be integrated into the National Leprosy control programmes with minimal additional efforts once contact tracing has been established. Therefore, we recommend integration of administration of SDR in to the routine leprosy control program.展开更多
Helicobacter pylori(H.pylori)infections may cause chronic gastritis,peptic ulcer disease,gastric cancers,and other conditions outside of the gastrointestinal tract.Hence,it is important to diagnose and treat it early....Helicobacter pylori(H.pylori)infections may cause chronic gastritis,peptic ulcer disease,gastric cancers,and other conditions outside of the gastrointestinal tract.Hence,it is important to diagnose and treat it early.H.pylori is resistant to certain drugs in traditional eradication therapy,so alternative therapy protocols are needed,such as high-dose amoxicillin dual therapy(HDADT).This article aims to comment on a recent paper by Costigan et al in the World Journal of Clinical Cases.In this study,the authors recruited 139 patients diagnosed with H.pylori,all treated with HDADT.Of these,93 were treatment-naïve and 46 had received at least one alternative treatment in the past.Four weeks after the end of the treatment,the urea breath test was administered to estimate the eradication rate.The total eradication rate was 56%(78/139),62%for the treatment-naïve arm and 43%for the previous treatment arm,thus indicating a lower success rate for the arm that had previously received a different treatment regimen.In conclusion,a therapeutic approach with first-line HDADT may potentially be a better treat-ment,but the results are not sufficient to recommend the use of this regimen in a country with high levels of dual resistance.展开更多
Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxid...Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine.展开更多
Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irra...Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.展开更多
Background: This study evaluated the bioequivalence of empagliflozin 12.5 mg/metformin 1000 mg tablets compared to Synjardy® (Empagliflozin 12.5 mg/metformin 1000 mg) tablets in healthy male subjects under fastin...Background: This study evaluated the bioequivalence of empagliflozin 12.5 mg/metformin 1000 mg tablets compared to Synjardy® (Empagliflozin 12.5 mg/metformin 1000 mg) tablets in healthy male subjects under fasting conditions. Methods: This was a phase I, randomized, single-dose, two-period, two-sequence, crossover study to evaluate the bioequivalence (BE) profiles of two fixed-dose combinations (FDCs) of empagliflozin/metformin. Cmax, AUC0-t and AUC0-∞ from test and reference formulations were evaluated to access BE. The plasma concentrations were measured using a validated liquid chromatography-mass spectrometry (LC-MS/MS) method. Of the 24 subjects enrolled, 23 completed both periods of the study. The two formulations test and reference were considered bioequivalent if 90% confidence interval (CI) fell within 80.00% - 125.00% for Cmax, AUC0-t and AUC0-∞. Tolerability and safety were assessed throughout the study. Results: The pharmacokinetic (PK) parameters were similar between the test product (T) and reference product (R) Synjardy®. The 90% CI of the test/reference ratios of log-transformed PK parameters point estimates was Cmax: 89.87% (85.68% - 94.27%), AUC0-t: 87.91% (83.65% - 92.39%) and AUC0-∞: 87.16% (82.80% - 91.75%) to empagliflozin and Cmax: 92.19% (87.95% - 96.65%), AUC0-t: 91.38% (84.42% - 98.91%) and AUC0-∞: 93.78% (83.82% - 104.93%) to metformin respectively (90% CI for all PK parameters fell within 80.00% - 125.00%). Conclusion: Our results demonstrated BE between the test and reference formulations of oral tablets of empagliflozin 12.5 mg/metformin 1000 mg (FDC) in healthy male subjects under fasting conditions.展开更多
The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calcu...The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calculating these doses. MC simulation model based on the Particle Simulation Tool (TOPAS) has been developed to simulate the off-field dose of an Elekta Synergy linear accelerator (Linac) emitting 6 MV photons. Measurements were taken in a water phantom using an ionization chamber to validate this model. The Percentage Depth Dose (PDD) at the depth of 0.0, 5.0, 10.0 and 15.0 cm from the beam axis for a 10 × 10 cm2 field size was measured and simulated. Off-field dose profiles at the depth of 1.5 (dmax), 5.0 and 10.0 cm for field sizes of 5 × 5, 10 × 10, 15 × 15, and 20 × 20 cm2 respectively were measured and simulated. Comparison of measured and simulated off-field dose values showed a good agreement. The average gamma passing rate of the PDDs and profiles curves for off-field doses were 87.5% and 98.11% respectively. The local dose difference based on the PDD curve between the measured and simulated was less than 6.0 % for all locations. For all field size considered in this study, the average difference between profile curves for off-field dose measured and simulated was 9.1%. PDDs and Profiles curves for off-field dose simulation uncertainties were less than 2.0% and 1.0% respectively. TOPAS-MC simulation model developed is a good representation of our 6 MV Linac Elekta Synergy for assessing off-field dose, which would be the primary cause of some secondary cancers.展开更多
This study aims to estimate the lifetime attributable cancer risk (LAR) for pediatric chest computed tomography (CT) examinations in five age groups using recently published age and region-specific conversion coeffici...This study aims to estimate the lifetime attributable cancer risk (LAR) for pediatric chest computed tomography (CT) examinations in five age groups using recently published age and region-specific conversion coefficients multiplying the widely available scanner registered dose length products (DLP) displayed on the CT console and hence calculating the Effective Dose (ED). The ED is then multiplied by the International Commission on Radiological Protection (ICRP) published risk factor for LAR. The obtained LAR values are compared with the international literature. Factors that may affect the LAR value are reported and discussed. The study included one hundred twenty five chest CT examinations for both males and females aged from less than one year to fifteen years. The patients reported data are from one single medical institution and using two CT scanners from June 2022 to December 2023. The results of this study may serve as benchmark for institutional radiation dose reference levels and risk estimation.展开更多
BACKGROUND The quality of a radiotherapy plan often depends on the knowledge and expertise of the plan designers.AIM To predict the uninvolved liver dose in stereotactic body radiotherapy(SBRT)for liver cancer using a...BACKGROUND The quality of a radiotherapy plan often depends on the knowledge and expertise of the plan designers.AIM To predict the uninvolved liver dose in stereotactic body radiotherapy(SBRT)for liver cancer using a neural network-based method.METHODS A total of 114 SBRT plans for liver cancer were used to test the neural network method.Sub-organs of the uninvolved liver were automatically generated.Correlations between the volume of each sub-organ,uninvolved liver dose,and neural network prediction model were established using MATLAB.Of the cases,70%were selected as the training set,15%as the validation set,and 15%as the test set.The regression R-value and mean square error(MSE)were used to evaluate the model.RESULTS The volume of the uninvolved liver was related to the volume of the corresponding sub-organs.For all sets of Rvalues of the prediction model,except for D_(n0)which was 0.7513,all R-values of D_(n10)-D_(n100)and D_(nmean)were>0.8.The MSE of the prediction model was also low.CONCLUSION We developed a neural network-based method to predict the uninvolved liver dose in SBRT for liver cancer.It is simple and easy to use and warrants further promotion and application.展开更多
Background: Among medical technologies that use ionizing radiation, CT is currently the radio diagnostic technic that can deliver the highest radiation to the Patient compared with other conventional procedures. In de...Background: Among medical technologies that use ionizing radiation, CT is currently the radio diagnostic technic that can deliver the highest radiation to the Patient compared with other conventional procedures. In developing countries, the uses and risks of CT have not been well characterized. Objective: To estimate the lifetime attributable risk (LAR) incidence and mortality for cancer for each procedure for adult’s patients who had Computed Tomography examinations in 10 imaging centers in the city of Douala-Cameroon so as to provide a reference data. Materials and Methods: We conducted a cross-sectional study describing radiation dose associated with the 8 most common types of diagnostic CT studies performed on 1287 consecutive adult patients at 10 Douala radiology department. We estimated lifetime attributable risks of cancer by study type from these measured doses. Estimation of LAR for cancer incidence and mortality was based on the effective dose, patient’s sex and age at exposure using the BIER VII preferred models. Results: Mean effective dose from CT scans examinations varied from: 0.30 and 8.81 mSv. The highest doses were observed for lumbar spine CT (8.81 mSv), followed by abdomen-pelvis procedure (6.46 mSv), chest-abdomen-pelvic CT (6.61 mSv), chest CT (3.90 mSv), cervical Spine CT (3.05 mSv), head CT (1.7 mSv) and lower for sinus CT (0.30 mSv). The LAR values of all cancer from patients’ CT scans obtained vary from 67.13 excess per 100,000 (about 1 in 1489) and 0.45 excess per 100,000 (about 1 in 222,222). All cancer risk was high for lumbar spine CT in women 20 years old (67.13 excess deaths in 100,000 scans) followed by chest-abdomen-pelvic CT (50.36 excess deaths in 100,000 scans) and abdomen-pelvic CT (49.22 excess deaths in 100,000 scans) for the same age group. The LAR of incidence and mortality values were higher from female’s patients than males and higher for younger than older patients. Conclusion: This study was set out to estimate the LAR values associated with adult common CT scans procedures. The data indicates, LAR risks related to induced cancer from CT exposures were estimated to be low. This risk can be relatively significant for younger age group compared to older age group. The LAR values obtained will help to better evaluate radiation exposure risk, before ordering a CT scans examinations.展开更多
Simulating the total ionizing dose(TID)of an electrical system using transistor-level models can be difficult and expensive,particularly for digital-integrated circuits(ICs).In this study,a method for modeling TID eff...Simulating the total ionizing dose(TID)of an electrical system using transistor-level models can be difficult and expensive,particularly for digital-integrated circuits(ICs).In this study,a method for modeling TID effects in complementary metaloxide semiconductor(CMOS)digital ICs based on the input/output buffer information specification(IBIS)was proposed.The digital IC was first divided into three parts based on its internal structure:the input buffer,output buffer,and functional area.Each of these three parts was separately modeled.Using the IBIS model,the transistor V-I characteristic curves of the buffers were processed,and the physical parameters were extracted and modeled using VHDL-AMS.In the functional area,logic functions were modeled in VHDL according to the data sheet.A golden digital IC model was developed by combining the input buffer,output buffer,and functional area models.Furthermore,the golden ratio was reconstructed based on TID experimental data,enabling the assessment of TID effects on the threshold voltage,carrier mobility,and time series of the digital IC.TID experiments were conducted using a CMOS non-inverting multiplexer,NC7SZ157,and the results were compared with the simulation results,which showed that the relative errors were less than 2%at each dose point.This confirms the practicality and accuracy of the proposed modeling method.The TID effect model for digital ICs developed using this modeling technique includes both the logical function of the IC and changes in electrical properties and functional degradation impacted by TID,which has potential applications in the design of radiation-hardening tolerance in digital ICs.展开更多
X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.Howev...X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.However,high X-ray irradiation dose caused organ lesions and side effects became the major barrier to X-PDT application.To address this issue,this work employed a classic-al co-precipitation reaction to synthesize NaLuF_(4):15%Tb^(3+)(NLF)with an average particle size of(23.48±0.91)nm,which was then coupled with the photosensitizer merocyanine 540(MC540)to form the X-PDT system NLF-MC540 with high production of singlet oxygen.The system could induce antitumor efficacy to about 24%in relative low dose X-ray irradiation range(0.1-0.3 Gy).In vivo,when NLF-MC540 irradiated by 0.1 Gy X-ray,the tumor inhibition percentage reached 89.5%±5.7%.The therapeutic mechanism of low dose X-PDT was found.A significant increase of neutrophils in serum was found on the third day after X-PDT.By immunohistochemical staining of tumor sections,the Ly6G^(+),CD8^(+),and CD11c^(+)cells infiltrated in the tumor microenvironment were studied.Utilizing the bilat-eral tumor model,the NLF-MC540 with 0.1 Gy X-ray irradiation could inhibit both the primary tumor and the distant tumor growth.De-tected by enzyme linked immunosorbent assay(ELISA),two cytokines IFN-γand TNF-αin serum were upregulated 7 and 6 times than negative control,respectively.Detected by enzyme linked immune spot assay(ELISPOT),the number of immune cells attributable to the IFN-γand TNF-αlevels in the group of low dose X-PDT were 14 and 6 times greater than that in the negative control group,respectively.Thus,it conclude that low dose X-PDT system could successfully upregulate the levels of immune cells,stimulate the secretion of cy-tokines(especially IFN-γand TNF-α),activate antitumor immunity,and finally inhibit colon tumor growth.展开更多
The rise in breast cancer diagnoses among Chinese women has necessitated the use of X-ray breast screening,which carries a radiation risk.This study aimed to provide a dosimetry protocol for the Chinese female populat...The rise in breast cancer diagnoses among Chinese women has necessitated the use of X-ray breast screening,which carries a radiation risk.This study aimed to provide a dosimetry protocol for the Chinese female population to replace the traditional standard that utilizes simplified breast models,for the accurate estimation of the mean glandular dose of a patient undergoing digital breast tomosynthesis(DBT).The first set of detailed Chinese female breast models and representative breast parameters was constructed.Considering backscatter radiation and computational efficiency,we improved the combination of these models and the Chinese reference adult female whole-body voxel phantom.Image acquisition for four commercial DBT systems that are widely employed in China was simulated using the Monte Carlo method to obtain the normalized glandular dose coefficients of DBT(D_(gN)^(DBT))and the glandular depth dose(D_(g)^(dep)(z))for different breast characteristics and X-ray spectra.We calculated a series of D_(gN)^(DBT) values for breasts with different percentage mass glandularities(5%,25%,50%,75%,and 100%)and compressed breast thicknesses(2,3,4,5,6,and 7 cm)at various tube potentials(25,28,30,32,35,and 49 kV)and target/filter combinations(W/Rh,W/Al,Mo/Mo,Rh/Rh,and Rh/Ag).The parameter dependence of the breast characteristics and beam conditions on D_(gN)^(DBT) in detailed breast models was investigated.The D_(gN)^(DBT) results were 14.6-51.0%lower than those of the traditional dosimetry standard in China.The difference in D_(gN)^(DBT) was mainly due to a decrease in the depth of the main energy deposition area caused by the glandular distribution along the depth direction.The results obtained in this study may be used to improve breast dosimetry in China and provide more detailed information on risk assessment during DBT.展开更多
Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement...Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement using ionization chamber is a prerequisite for absorbed dose determination for external beam radiotherapy. Calibration coefficient is expressed in terms of air kerma and absorbed dose to water traceable to Secondary Standards Dosimetry Laboratory. The objective of this work was to evaluate the level of accuracy of ionization chamber used for clinical radiotherapy beam determination. Measurement and accuracy determination were carried out according to IAEA TRS 398 protocol. Clinical farmers type ionization chamber measurement and National Reference standard from Secondary Standards Dosimetry Laboratory were both exposed to cobalt-60 beam and measurement results compared under the same environmental conditions. The accuracy level between National Reference Standard and clinical radiotherapy standard was found to be −1.92% and −2.02% for air kerma and absorbed dose to water respectively. To minimize the effect of error and maximize therapeutic dose during treatment in order to achieve required clinical outcome, calibration factor was determined for air kerma (Nk) as 49.7 mGy/nC and absorbed dose to water ND, as 52.9 mGy/nC. The study established that radiotherapy beam measurement chain is prone to errors. Hence there is a need to independently verify the accuracy of radiation dose to ensure precision of dose delivery. The errors must be accounted for during clinical planning by factoring in calibration factor to minimize the systematic errors during treatment, and thereby providing enough room to achieve ±5% dose delivery to tumor target as recommended by ICRU.展开更多
文摘Radiation protection programs aims to reduce the radiation dose to the lowest possible level under the Dose Limit (DL) limit by the national or international laws, while the dose monitoring programs working as scale used to evaluating the efficiency of these programs and tools. In this study, the average of the annual Eff dose for the intensive care units at Hamad General Hospital (HGH) is less than the 50% of DL. It was aiming also to evaluate the efficiency of the radiation safety requirements (especially the shielding Adequacy) for the non radiation workers at oncology centers, hence several monitors were installed in chosen locations outside the radiation treatment machine from 2007 to 2011.
文摘AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected"real world"patients.METHODS In this single-centre study,consecutive patients in sinus rhythm underwent CCTA for suspected coronary artery disease(CAD)using a 320-row detector CT scanner.All patients underwent the standard CT acquisition protocol at our institute(Morriston Hospital)a combination of dose saving advances including prospective electrocardiogram-gating,automated tube current modulation,tube voltage reduction,heart rate reduction,and the most recent novel adaptive iterative dose reconstruction 3D(AIDR3D)algorithm.The cohort comprised real-world patients for routine CCTA who were not selected on age,body mass index,or heart rate.Subjective image quality was graded on a 4-point scale(4=excellent,1=non-diagnostic).RESULTS A total of 543 patients were included in the study with a mean body weight of 81±18 kg and a pre-scan mean heart rate of 70±11 beats per minute(bpm).When indicated,patients received rate-limiting medication with an oral beta-blocker followed by additional intravenous beta-blocker to achieve a heart rate below 65 bpm.The median effective radiation dose was 0.88 mSv(IQR,0.6-1.4 mSv)derived from a Dose Length Product of61.45 mGy.cm(IQR,42.86-100.00 mGy.cm).This also includes what we believe to be the lowest ever-reported radiation dose for a routine clinical CCTA(0.18 mSv).The mean image quality(SD)was 3.65±0.61,with a subjective image quality score of 3("good")or above for 93%of patient CCTAs.CONCLUSION Combining a low-dose scan protocol and AIDR3D with a 320-detector row CT scanner can provide high quality images at exceptionally low radiation dose in unselected patients being investigated for CAD.
文摘BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resistance such as ours,Maastricht VI guidelines suggest high dose amoxicillin dual therapy(HDADT)can be considered,subject to evidence for local efficacy.In this study we assess efficacy of HDADT therapy for H.pylori eradication in an Irish cohort.AIM To assess the efficacy of HDADT therapy for H.pylori eradication in an Irish cohort as both first line,and subsequent therapy for patients diagnosed with H.pylori.METHODS All patients testing positive for H.pylori in a tertiary centre were treated prospectively with HDADT(amoxicillin 1 g tid and esomeprazole 40 mg bid×14 d)over a period of 8 months.Eradication was confirmed with Urea Breath Test at least 4 wk after cessation of therapy.A delta-over-baseline>4%was considered positive.Patient demographics and treatment outcomes were recorded,analysed and controlled for basic demographics and prior H.pylori treatment.RESULTS One hundred and ninety-eight patients were identified with H.pylori infection,10 patients were excluded due to penicillin allergy and 38 patients refused follow up testing.In all 139 were included in the analysis,55%(n=76)were female,mean age was 46.6 years.Overall,93(67%)of patients were treatment-naïve and 46(33%)had received at least one previous course of treatment.The groups were statistically similar.Self-reported compliance with HDADT was 97%,mild side-effects occurred in 7%.There were no serious adverse drug reactions.Overall the eradication rate for our cohort was 56%(78/139).Eradication rates were worse for those with previous treatment[43%(20/46)vs 62%(58/93),P=0.0458,odds ratio=2.15].Age and Gender had no effect on eradication status.CONCLUSION Overall eradication rates with HDADT were disappointing.Despite being a simple and possibly better tolerated regime,these results do not support its routine use in a high dual resistance country.Further investigation of other regimens to achieve the>90%eradication target is needed.
基金The National Natural Science Foundation Committee(No. 39770823)
文摘Objective To identlfy the member of the caspase famlly proteases involved in Y-radiation-inducedapoptosis in HL-60 cells and to study the expression or the caspase gene in normal, apoptotic cells and in immortal tumor cells. Methods By using degenerate oligonucleotide primers encoding the highly conserved peptides that were present in all known caspases, we performed RT-PCR on poly(A)RNA from γ-radiation-induced apoptotic HL-6o cells.Caspase-3 mRNA in apoptotic HL-6o cells and in human tumor cell lines was analyzed by Northern blot. Results The amplified DNA fragment was identiried with caspase-3 cDNA by cloning and sequencing. The Northern blot analysis of caspase-3 mRNA of different human tumor cell lines showed that the caspase-3 gene transcript was more highly expressed in leukemia cell lines and the SH-SY5Y cell line than in HeLa and MCF-7 cells. It was more highly expressed in the radiation-induced apoptotic HL-6o cells than in control HL-6o cells. Conclusion These results indicated that caspase-3 was involved in γ-radiation-induced apoptosis in HL-6o cells. The high level of expression or caspase-3 may aid efforts to understand the insensitivity of some tumor cells to radlation, their inherent ability to survive, and apoptosis
文摘Coronaviruses are a diverse group of viruses that infect both animals and humans.Even though the existence of coronavirus and its infection to humans is not new,the 2019-novel coronavirus(nCoV)caused a major burden to individuals and society i.e.,anxiety,fear of infection,extreme competition for hospitalization,and more importantly financial liability.The nCoV infection/disease diagnosis was based on non-specific signs and symptoms,biochemical parameters,detection of the virus using reverse-transcription polymerase chain reaction(RTPCR),and X-ray-based imaging.This review focuses on the consolidation of potentials of X-ray-based imaging modality[chest-X radiography(CXR)and chest computed tomography(CT)]and low-dose radiation therapy(LDRT)for screening,severity,and management of COVID-19 disease.Reported studies suggest that CXR contributed significantly toward initial rapid screening/diagnosis and CT-imaging to monitor the disease severity.The chest CT has high sensitivity up to 98%and low specificity for diagnosis and severity of COVID-19 disease compared to RT-PCR.Similarly,LDRT compliments drug therapy in the early recovery/Less hospital stays by maintaining the physiological parameters better than the drug therapy alone.All the results undoubtedly demonstrated the evidence that X-ray-based technology continues to evolve and play a significant role in human health care even during the pandemic.
基金supported by the National Key R&D Program of China(No.2022YFC2402300)National Natural Science Foundation of China(No.12075330)。
文摘Ultrahigh-dose-rate radiotherapy(FLASH-RT)is a revolutionary radiotherapy technology that can spare normal tissues without compromising tumor control.Although qualitative experimental results have been reported,quantitative and systematic analysis of data is necessary.Particularly,the FLASH effect response model to the dose or dose rate is still unclear.This study investigated the relationships between the FLASH effect and experimental parameters,such as dose,dose rate,and other factors by analyzing published in vivo experimental data from animal models.The data were modeled based on logistic regression analysis using the sigmoid function.The model was evaluated using prediction accuracy,receiver operating characteristic(ROC)curve,and area under the ROC curve.Results showed that the FLASH effect was closely related to the dose,mean dose rate,tissue type,and corresponding biological endpoints.The dose rate corresponding to a 50% probability of triggering cognitive protection in the brain was 45 Gy s^(-1).The dose rate corresponding to a 50% probability of triggering intestinal crypt survival and regeneration was 140 Gy s^(-1).For the skin toxicity effect,the dose corresponding to a 50% probability of triggering the FLASH effect was 24 Gy.This study helps to characterize the conditions underlying the FLASH effect and provides important information for optimizing experiments.
文摘Background: World Health Organization recommends the implementation of contact tracing and Leprosy Post Exposure prophylaxis (LPEP) to interrupt the chain of transmission. To accelerate the uptake of this recommendation, a cross-sectional study among contacts of leprosy patients was conducted to investigate the feasibility of integrating leprosy systematic contact tracing and post-exposure prophylaxis (PEP) into the routine leprosy control program. Methods: This was a mixed methods cross-sectional study. The study was implemented in Kumi, Ngora, Serere, Soroti, Budaka and Kibuku Districts. Results: The 45 enrolled index patients (97.8% of the registered) identified a total of 135 contacts, of which 134 (99·2%) consented and were screened. Among them, one new leprosy patient was identified and started on treatment with multidrug therapy (MDT). All the eligible contacts, received the prophylactic treatment with Single Dose Rifampicin (SDR). Overall, SDR was administered to 133(98.5% of the listed contacts) with no adverse event reported. Factors associated with successful contact investigation and management included: Involvement of index patients, health care workers during the contact screening and SDR A administration, counselling of the index patients and contacts by the health care works, LPEP being administered as Directly observed Therapy (DOT) among others. Results Interpretation: The integration of leprosy post-exposure prophylaxis with administration of SDR and contact tracing is feasible, generally accepted by the patient, their contacts and health workers and can be integrated into the National Leprosy control programmes with minimal additional efforts once contact tracing has been established. Therefore, we recommend integration of administration of SDR in to the routine leprosy control program.
文摘Helicobacter pylori(H.pylori)infections may cause chronic gastritis,peptic ulcer disease,gastric cancers,and other conditions outside of the gastrointestinal tract.Hence,it is important to diagnose and treat it early.H.pylori is resistant to certain drugs in traditional eradication therapy,so alternative therapy protocols are needed,such as high-dose amoxicillin dual therapy(HDADT).This article aims to comment on a recent paper by Costigan et al in the World Journal of Clinical Cases.In this study,the authors recruited 139 patients diagnosed with H.pylori,all treated with HDADT.Of these,93 were treatment-naïve and 46 had received at least one alternative treatment in the past.Four weeks after the end of the treatment,the urea breath test was administered to estimate the eradication rate.The total eradication rate was 56%(78/139),62%for the treatment-naïve arm and 43%for the previous treatment arm,thus indicating a lower success rate for the arm that had previously received a different treatment regimen.In conclusion,a therapeutic approach with first-line HDADT may potentially be a better treat-ment,but the results are not sufficient to recommend the use of this regimen in a country with high levels of dual resistance.
基金supported by Guangzhou Science and Technology Planning Project(2023A04J0131)Special fund for scientific innovation strategyconstruction of high level Academy of Agriculture Science(R2020PY-JG009,R2022PY-QY007,202106TD)+2 种基金China Agriculture Research System-CARS-35the Project of Swine Innovation Team in Guangdong Modern Agricultural Research System(2022KJ126)Special Fund for Rural Revitalization Strategy of Guangdong(2023TS-3),China。
文摘Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine.
文摘Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.
文摘Background: This study evaluated the bioequivalence of empagliflozin 12.5 mg/metformin 1000 mg tablets compared to Synjardy® (Empagliflozin 12.5 mg/metformin 1000 mg) tablets in healthy male subjects under fasting conditions. Methods: This was a phase I, randomized, single-dose, two-period, two-sequence, crossover study to evaluate the bioequivalence (BE) profiles of two fixed-dose combinations (FDCs) of empagliflozin/metformin. Cmax, AUC0-t and AUC0-∞ from test and reference formulations were evaluated to access BE. The plasma concentrations were measured using a validated liquid chromatography-mass spectrometry (LC-MS/MS) method. Of the 24 subjects enrolled, 23 completed both periods of the study. The two formulations test and reference were considered bioequivalent if 90% confidence interval (CI) fell within 80.00% - 125.00% for Cmax, AUC0-t and AUC0-∞. Tolerability and safety were assessed throughout the study. Results: The pharmacokinetic (PK) parameters were similar between the test product (T) and reference product (R) Synjardy®. The 90% CI of the test/reference ratios of log-transformed PK parameters point estimates was Cmax: 89.87% (85.68% - 94.27%), AUC0-t: 87.91% (83.65% - 92.39%) and AUC0-∞: 87.16% (82.80% - 91.75%) to empagliflozin and Cmax: 92.19% (87.95% - 96.65%), AUC0-t: 91.38% (84.42% - 98.91%) and AUC0-∞: 93.78% (83.82% - 104.93%) to metformin respectively (90% CI for all PK parameters fell within 80.00% - 125.00%). Conclusion: Our results demonstrated BE between the test and reference formulations of oral tablets of empagliflozin 12.5 mg/metformin 1000 mg (FDC) in healthy male subjects under fasting conditions.
文摘The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calculating these doses. MC simulation model based on the Particle Simulation Tool (TOPAS) has been developed to simulate the off-field dose of an Elekta Synergy linear accelerator (Linac) emitting 6 MV photons. Measurements were taken in a water phantom using an ionization chamber to validate this model. The Percentage Depth Dose (PDD) at the depth of 0.0, 5.0, 10.0 and 15.0 cm from the beam axis for a 10 × 10 cm2 field size was measured and simulated. Off-field dose profiles at the depth of 1.5 (dmax), 5.0 and 10.0 cm for field sizes of 5 × 5, 10 × 10, 15 × 15, and 20 × 20 cm2 respectively were measured and simulated. Comparison of measured and simulated off-field dose values showed a good agreement. The average gamma passing rate of the PDDs and profiles curves for off-field doses were 87.5% and 98.11% respectively. The local dose difference based on the PDD curve between the measured and simulated was less than 6.0 % for all locations. For all field size considered in this study, the average difference between profile curves for off-field dose measured and simulated was 9.1%. PDDs and Profiles curves for off-field dose simulation uncertainties were less than 2.0% and 1.0% respectively. TOPAS-MC simulation model developed is a good representation of our 6 MV Linac Elekta Synergy for assessing off-field dose, which would be the primary cause of some secondary cancers.
文摘This study aims to estimate the lifetime attributable cancer risk (LAR) for pediatric chest computed tomography (CT) examinations in five age groups using recently published age and region-specific conversion coefficients multiplying the widely available scanner registered dose length products (DLP) displayed on the CT console and hence calculating the Effective Dose (ED). The ED is then multiplied by the International Commission on Radiological Protection (ICRP) published risk factor for LAR. The obtained LAR values are compared with the international literature. Factors that may affect the LAR value are reported and discussed. The study included one hundred twenty five chest CT examinations for both males and females aged from less than one year to fifteen years. The patients reported data are from one single medical institution and using two CT scanners from June 2022 to December 2023. The results of this study may serve as benchmark for institutional radiation dose reference levels and risk estimation.
基金Supported by the Open Fund for Scientific Research of Jiangxi Cancer Hospital,No.2021J15the Gulin People's Hospital-The Affiliated Hospital of Southwest Medical University Science and Technology Strategic Cooperation Project,No.2022GLXNYDFY05the Sichuan Provincial Medical Research Project Plan,No.S21004.
文摘BACKGROUND The quality of a radiotherapy plan often depends on the knowledge and expertise of the plan designers.AIM To predict the uninvolved liver dose in stereotactic body radiotherapy(SBRT)for liver cancer using a neural network-based method.METHODS A total of 114 SBRT plans for liver cancer were used to test the neural network method.Sub-organs of the uninvolved liver were automatically generated.Correlations between the volume of each sub-organ,uninvolved liver dose,and neural network prediction model were established using MATLAB.Of the cases,70%were selected as the training set,15%as the validation set,and 15%as the test set.The regression R-value and mean square error(MSE)were used to evaluate the model.RESULTS The volume of the uninvolved liver was related to the volume of the corresponding sub-organs.For all sets of Rvalues of the prediction model,except for D_(n0)which was 0.7513,all R-values of D_(n10)-D_(n100)and D_(nmean)were>0.8.The MSE of the prediction model was also low.CONCLUSION We developed a neural network-based method to predict the uninvolved liver dose in SBRT for liver cancer.It is simple and easy to use and warrants further promotion and application.
文摘Background: Among medical technologies that use ionizing radiation, CT is currently the radio diagnostic technic that can deliver the highest radiation to the Patient compared with other conventional procedures. In developing countries, the uses and risks of CT have not been well characterized. Objective: To estimate the lifetime attributable risk (LAR) incidence and mortality for cancer for each procedure for adult’s patients who had Computed Tomography examinations in 10 imaging centers in the city of Douala-Cameroon so as to provide a reference data. Materials and Methods: We conducted a cross-sectional study describing radiation dose associated with the 8 most common types of diagnostic CT studies performed on 1287 consecutive adult patients at 10 Douala radiology department. We estimated lifetime attributable risks of cancer by study type from these measured doses. Estimation of LAR for cancer incidence and mortality was based on the effective dose, patient’s sex and age at exposure using the BIER VII preferred models. Results: Mean effective dose from CT scans examinations varied from: 0.30 and 8.81 mSv. The highest doses were observed for lumbar spine CT (8.81 mSv), followed by abdomen-pelvis procedure (6.46 mSv), chest-abdomen-pelvic CT (6.61 mSv), chest CT (3.90 mSv), cervical Spine CT (3.05 mSv), head CT (1.7 mSv) and lower for sinus CT (0.30 mSv). The LAR values of all cancer from patients’ CT scans obtained vary from 67.13 excess per 100,000 (about 1 in 1489) and 0.45 excess per 100,000 (about 1 in 222,222). All cancer risk was high for lumbar spine CT in women 20 years old (67.13 excess deaths in 100,000 scans) followed by chest-abdomen-pelvic CT (50.36 excess deaths in 100,000 scans) and abdomen-pelvic CT (49.22 excess deaths in 100,000 scans) for the same age group. The LAR of incidence and mortality values were higher from female’s patients than males and higher for younger than older patients. Conclusion: This study was set out to estimate the LAR values associated with adult common CT scans procedures. The data indicates, LAR risks related to induced cancer from CT exposures were estimated to be low. This risk can be relatively significant for younger age group compared to older age group. The LAR values obtained will help to better evaluate radiation exposure risk, before ordering a CT scans examinations.
基金This work was supported by the special fund of the State Key Laboratory of Intense Pulsed Radiation Simulation and Effect(No.SKLIPR2011).
文摘Simulating the total ionizing dose(TID)of an electrical system using transistor-level models can be difficult and expensive,particularly for digital-integrated circuits(ICs).In this study,a method for modeling TID effects in complementary metaloxide semiconductor(CMOS)digital ICs based on the input/output buffer information specification(IBIS)was proposed.The digital IC was first divided into three parts based on its internal structure:the input buffer,output buffer,and functional area.Each of these three parts was separately modeled.Using the IBIS model,the transistor V-I characteristic curves of the buffers were processed,and the physical parameters were extracted and modeled using VHDL-AMS.In the functional area,logic functions were modeled in VHDL according to the data sheet.A golden digital IC model was developed by combining the input buffer,output buffer,and functional area models.Furthermore,the golden ratio was reconstructed based on TID experimental data,enabling the assessment of TID effects on the threshold voltage,carrier mobility,and time series of the digital IC.TID experiments were conducted using a CMOS non-inverting multiplexer,NC7SZ157,and the results were compared with the simulation results,which showed that the relative errors were less than 2%at each dose point.This confirms the practicality and accuracy of the proposed modeling method.The TID effect model for digital ICs developed using this modeling technique includes both the logical function of the IC and changes in electrical properties and functional degradation impacted by TID,which has potential applications in the design of radiation-hardening tolerance in digital ICs.
基金funded by the National Natural Science Foundation of China (Nos.81771972,52171243,and 52371256)the National Key Research and Development Program of China (No.2017YFC0107405).
文摘X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.However,high X-ray irradiation dose caused organ lesions and side effects became the major barrier to X-PDT application.To address this issue,this work employed a classic-al co-precipitation reaction to synthesize NaLuF_(4):15%Tb^(3+)(NLF)with an average particle size of(23.48±0.91)nm,which was then coupled with the photosensitizer merocyanine 540(MC540)to form the X-PDT system NLF-MC540 with high production of singlet oxygen.The system could induce antitumor efficacy to about 24%in relative low dose X-ray irradiation range(0.1-0.3 Gy).In vivo,when NLF-MC540 irradiated by 0.1 Gy X-ray,the tumor inhibition percentage reached 89.5%±5.7%.The therapeutic mechanism of low dose X-PDT was found.A significant increase of neutrophils in serum was found on the third day after X-PDT.By immunohistochemical staining of tumor sections,the Ly6G^(+),CD8^(+),and CD11c^(+)cells infiltrated in the tumor microenvironment were studied.Utilizing the bilat-eral tumor model,the NLF-MC540 with 0.1 Gy X-ray irradiation could inhibit both the primary tumor and the distant tumor growth.De-tected by enzyme linked immunosorbent assay(ELISA),two cytokines IFN-γand TNF-αin serum were upregulated 7 and 6 times than negative control,respectively.Detected by enzyme linked immune spot assay(ELISPOT),the number of immune cells attributable to the IFN-γand TNF-αlevels in the group of low dose X-PDT were 14 and 6 times greater than that in the negative control group,respectively.Thus,it conclude that low dose X-PDT system could successfully upregulate the levels of immune cells,stimulate the secretion of cy-tokines(especially IFN-γand TNF-α),activate antitumor immunity,and finally inhibit colon tumor growth.
基金supported by the National Natural Science Foundation of China(Nos.U2167209 and 12175114)the National Key R&D Program of China(No.2021YFF0603600).
文摘The rise in breast cancer diagnoses among Chinese women has necessitated the use of X-ray breast screening,which carries a radiation risk.This study aimed to provide a dosimetry protocol for the Chinese female population to replace the traditional standard that utilizes simplified breast models,for the accurate estimation of the mean glandular dose of a patient undergoing digital breast tomosynthesis(DBT).The first set of detailed Chinese female breast models and representative breast parameters was constructed.Considering backscatter radiation and computational efficiency,we improved the combination of these models and the Chinese reference adult female whole-body voxel phantom.Image acquisition for four commercial DBT systems that are widely employed in China was simulated using the Monte Carlo method to obtain the normalized glandular dose coefficients of DBT(D_(gN)^(DBT))and the glandular depth dose(D_(g)^(dep)(z))for different breast characteristics and X-ray spectra.We calculated a series of D_(gN)^(DBT) values for breasts with different percentage mass glandularities(5%,25%,50%,75%,and 100%)and compressed breast thicknesses(2,3,4,5,6,and 7 cm)at various tube potentials(25,28,30,32,35,and 49 kV)and target/filter combinations(W/Rh,W/Al,Mo/Mo,Rh/Rh,and Rh/Ag).The parameter dependence of the breast characteristics and beam conditions on D_(gN)^(DBT) in detailed breast models was investigated.The D_(gN)^(DBT) results were 14.6-51.0%lower than those of the traditional dosimetry standard in China.The difference in D_(gN)^(DBT) was mainly due to a decrease in the depth of the main energy deposition area caused by the glandular distribution along the depth direction.The results obtained in this study may be used to improve breast dosimetry in China and provide more detailed information on risk assessment during DBT.
文摘Radiotherapy is the most widely applied oncologic treatment modality utilizing ionizing radiation. A high degree of accuracy, reliability and reproducibility is required for a successful treatment outcome. Measurement using ionization chamber is a prerequisite for absorbed dose determination for external beam radiotherapy. Calibration coefficient is expressed in terms of air kerma and absorbed dose to water traceable to Secondary Standards Dosimetry Laboratory. The objective of this work was to evaluate the level of accuracy of ionization chamber used for clinical radiotherapy beam determination. Measurement and accuracy determination were carried out according to IAEA TRS 398 protocol. Clinical farmers type ionization chamber measurement and National Reference standard from Secondary Standards Dosimetry Laboratory were both exposed to cobalt-60 beam and measurement results compared under the same environmental conditions. The accuracy level between National Reference Standard and clinical radiotherapy standard was found to be −1.92% and −2.02% for air kerma and absorbed dose to water respectively. To minimize the effect of error and maximize therapeutic dose during treatment in order to achieve required clinical outcome, calibration factor was determined for air kerma (Nk) as 49.7 mGy/nC and absorbed dose to water ND, as 52.9 mGy/nC. The study established that radiotherapy beam measurement chain is prone to errors. Hence there is a need to independently verify the accuracy of radiation dose to ensure precision of dose delivery. The errors must be accounted for during clinical planning by factoring in calibration factor to minimize the systematic errors during treatment, and thereby providing enough room to achieve ±5% dose delivery to tumor target as recommended by ICRU.