The energetic bremsstrahlung photons up to 100 MeV produced in heavy ion collisions can be used as a sensitive probe for short-range correlation in atomic nuclei. The energy of the γ-rays can be measured by collectin...The energetic bremsstrahlung photons up to 100 MeV produced in heavy ion collisions can be used as a sensitive probe for short-range correlation in atomic nuclei. The energy of the γ-rays can be measured by collecting the Čerenkov light in the medium induced by the fast electrons generated in the Compton scattering or electromagnetic shower of the incident γray. Two types of detectors based on pure water and lead glass as sensitive materials were designed for this purpose. The γresponse and optical photon propagation in the detectors were simulated based on electromagnetic and optical processes in Geant4. The inherent energy resolutions of 0.022(4) + 0.51(2)∕E^(1/2)_(γ) for water and 0.0026(3) + 0.446(3)∕E^(1/2)_(γ) for lead glass were obtained. The geometry sizes of the lead glass and water were optimized to 30 cm × 30 cm × 30 cm and 60 cm × 60 cm ×120 cm, respectively, to detect high-energy γ-rays at 160 MeV. The Hough transform method was applied to reconstruct the direction of the incident γ-rays, providing the ability to experimentally distinguish the high-energy γ-rays produced in the reactions on the target from random background cosmic-ray muons.展开更多
To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resul...To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resulting in an extremely low detection limit and improving the measurement accuracy.However,the complex and expensive hardware required does not facilitate the application or promotion of this method.Thus,a method is proposed in this study to discriminate the digital waveform of pulse signals output using an HPGe detector,whereby Compton scattering background is suppressed and a low minimum detectable activity(MDA)is achieved without using an expensive and complex anticoincidence detector and device.The electric-field-strength and energy-deposition distributions of the detector are simulated to determine the relationship between pulse shape and energy-deposition location,as well as the characteristics of energy-deposition distributions for fulland partial-energy deposition events.This relationship is used to develop a pulse-shape-discrimination algorithm based on an artificial neural network for pulse-feature identification.To accurately determine the relationship between the deposited energy of gamma(γ)rays in the detector and the deposition location,we extract four shape parameters from the pulse signals output by the detector.Machine learning is used to input the four shape parameters into the detector.Subsequently,the pulse signals are identified and classified to discriminate between partial-and full-energy deposition events.Some partial-energy deposition events are removed to suppress Compton scattering.The proposed method effectively decreases the MDA of an HPGeγ-energy dispersive spectrometer.Test results show that the Compton suppression factors for energy spectra obtained from measurements on ^(152)Eu,^(137)Cs,and ^(60)Co radioactive sources are 1.13(344 keV),1.11(662 keV),and 1.08(1332 keV),respectively,and that the corresponding MDAs are 1.4%,5.3%,and 21.6%lower,respectively.展开更多
Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate ...Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management.展开更多
Inγ-ray imaging,localization of theγ-ray interaction in the scintillator is critical.Convolutional neural network(CNN)techniques are highly promising for improvingγ-ray localization.Our study evaluated the generali...Inγ-ray imaging,localization of theγ-ray interaction in the scintillator is critical.Convolutional neural network(CNN)techniques are highly promising for improvingγ-ray localization.Our study evaluated the generalization capabilities of a CNN localization model with respect to theγ-ray energy and thickness of the crystal.The model maintained a high positional linearity(PL)and spatial resolution for ray energies between 59 and 1460 keV.The PL at the incident surface of the detector was 0.99,and the resolution of the central incident point source ranged between 0.52 and 1.19 mm.In modified uniform redundant array(MURA)imaging systems using a thick crystal,the CNNγ-ray localization model significantly improved the useful field-of-view(UFOV)from 60.32 to 93.44%compared to the classical centroid localization methods.Additionally,the signal-to-noise ratio of the reconstructed images increased from 0.95 to 5.63.展开更多
The unknown γ-ray excess in the northwest region of Arp 220 was revisited by analyzing~11.8 years of the Fermi Large Area Telescope(Fermi-LAT) data in this study.We found that its photon flux was approximately three ...The unknown γ-ray excess in the northwest region of Arp 220 was revisited by analyzing~11.8 years of the Fermi Large Area Telescope(Fermi-LAT) data in this study.We found that its photon flux was approximately three times higher than that of the previous study in the 0.2-100 GeV band,and the corresponding significance level ~8.15σ was approximately four times higher than before.The light curves of 15 and 45 time bins from the whole time all showed two active periods,and the variability of the second period was more significant than that of the first period.The spectral indices from the two active periods were not statistically different and were close to the range of γ-ray flat-spectrum radio quasars observed by Fermi-LAT.Because the position of CRATES J153246+234400 was consistent with the best-fit position of our analysis,we suggest that CRATES J153246+234400 is more likely a γ-ray counterpart for the variational region.For Arp 220,there was no significant variability in the γ-ray emission.展开更多
Theγ-rays are widely and abundantly present in strong nuclear radiation environments,and when they act on the camera equipment used to obtain environmental visual information on nuclear robots,radiation effects will ...Theγ-rays are widely and abundantly present in strong nuclear radiation environments,and when they act on the camera equipment used to obtain environmental visual information on nuclear robots,radiation effects will occur,which will degrade the performance of the camera system,reduce the imaging quality,and even cause catastrophic consequences.Color reducibility is an important index for evaluating the imaging quality of color camera,but its degradation mechanism in a nuclear radiation environment is still unclear.In this paper,theγ-ray irradiation experiments of CMOS cameras were carried out to analyse the degradation law of the camera’s color reducibility with cumulative irradiation and reveal the degradation mechanism of the color information of the CMOS camera underγ-ray irradiation.The results show that the spectral response of CMOS image sensor(CIS)and the spectral transmittance of lens after irradiation affect the values of a^(*)and b^(*)in the LAB color model.While the full well capacity(FWC)of CIS and transmittance of lens affect the value of L^(*)in the LAB color model,thus increase color difference and reduce brightness,the combined effect of color difference and brightness degradation will reduce the color reducibility of CMOS cameras.Therefore,the degradation of the color information of the CMOS camera afterγ-ray irradiation mainly comes from the changes in the FWC and spectral response of CIS,and the spectral transmittance of lens.展开更多
In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ...In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.展开更多
Taking a propfan engine as the research object,the CFD method was used for 3D modeling and unsteady slip flow for numerical calculation.The propfan rotation domain and the nacelle outside flow domain were meshed by us...Taking a propfan engine as the research object,the CFD method was used for 3D modeling and unsteady slip flow for numerical calculation.The propfan rotation domain and the nacelle outside flow domain were meshed by using the partition splicing grid technology.Used the Reynolds⁃averaged of N⁃S equation,the Reynolds stress term uses the RNG turbulence model;and based on the slip grid method,numerical calculation of the flow field with different Mach numbers,front and rear blade angles and engine state were carried out;and the change law of propeller fan characteristics and the influence of slip flow on the inlet flow field were analyzed.The blade angle was the key parameter of the propeller fan characteristic conditions.When the blade angle increases from 41°to 50°,the thrust coefficient increases by 31.2%,and the power coefficient increases by 33.4%;in the climbing state of the propeller fan,the maximum total pressure distortion at the inlet port of 6.8%;the cross section is less affected by the slip flow of the propfan;and the pressure distribution is relatively uniform,but the area of the flow channel is small.The research results can provide a solution for the matching of the counter⁃rotating propeller fan and the engine and the arrangement of the air inlet measuring rake.展开更多
基金This work was supported by the Ministry of Science and Technology(No.2020YFE0202001)by the National Natural Science Foundation of China(Nos.11961141004 and 12205160)Tsinghua University Initiative Scientific Research Program.
文摘The energetic bremsstrahlung photons up to 100 MeV produced in heavy ion collisions can be used as a sensitive probe for short-range correlation in atomic nuclei. The energy of the γ-rays can be measured by collecting the Čerenkov light in the medium induced by the fast electrons generated in the Compton scattering or electromagnetic shower of the incident γray. Two types of detectors based on pure water and lead glass as sensitive materials were designed for this purpose. The γresponse and optical photon propagation in the detectors were simulated based on electromagnetic and optical processes in Geant4. The inherent energy resolutions of 0.022(4) + 0.51(2)∕E^(1/2)_(γ) for water and 0.0026(3) + 0.446(3)∕E^(1/2)_(γ) for lead glass were obtained. The geometry sizes of the lead glass and water were optimized to 30 cm × 30 cm × 30 cm and 60 cm × 60 cm ×120 cm, respectively, to detect high-energy γ-rays at 160 MeV. The Hough transform method was applied to reconstruct the direction of the incident γ-rays, providing the ability to experimentally distinguish the high-energy γ-rays produced in the reactions on the target from random background cosmic-ray muons.
基金This work was supported by the National Key R&D Program of China(Nos.2022YFF0709503,2022YFB1902700,2017YFC0602101)the Key Research and Development Program of Sichuan province(No.2023YFG0347)the Key Research and Development Program of Sichuan province(No.2020ZDZX0007).
文摘To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resulting in an extremely low detection limit and improving the measurement accuracy.However,the complex and expensive hardware required does not facilitate the application or promotion of this method.Thus,a method is proposed in this study to discriminate the digital waveform of pulse signals output using an HPGe detector,whereby Compton scattering background is suppressed and a low minimum detectable activity(MDA)is achieved without using an expensive and complex anticoincidence detector and device.The electric-field-strength and energy-deposition distributions of the detector are simulated to determine the relationship between pulse shape and energy-deposition location,as well as the characteristics of energy-deposition distributions for fulland partial-energy deposition events.This relationship is used to develop a pulse-shape-discrimination algorithm based on an artificial neural network for pulse-feature identification.To accurately determine the relationship between the deposited energy of gamma(γ)rays in the detector and the deposition location,we extract four shape parameters from the pulse signals output by the detector.Machine learning is used to input the four shape parameters into the detector.Subsequently,the pulse signals are identified and classified to discriminate between partial-and full-energy deposition events.Some partial-energy deposition events are removed to suppress Compton scattering.The proposed method effectively decreases the MDA of an HPGeγ-energy dispersive spectrometer.Test results show that the Compton suppression factors for energy spectra obtained from measurements on ^(152)Eu,^(137)Cs,and ^(60)Co radioactive sources are 1.13(344 keV),1.11(662 keV),and 1.08(1332 keV),respectively,and that the corresponding MDAs are 1.4%,5.3%,and 21.6%lower,respectively.
文摘Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management.
基金supported by the National Natural Science Foundation of China(Nos.41874121 and U19A2086)。
文摘Inγ-ray imaging,localization of theγ-ray interaction in the scintillator is critical.Convolutional neural network(CNN)techniques are highly promising for improvingγ-ray localization.Our study evaluated the generalization capabilities of a CNN localization model with respect to theγ-ray energy and thickness of the crystal.The model maintained a high positional linearity(PL)and spatial resolution for ray energies between 59 and 1460 keV.The PL at the incident surface of the detector was 0.99,and the resolution of the central incident point source ranged between 0.52 and 1.19 mm.In modified uniform redundant array(MURA)imaging systems using a thick crystal,the CNNγ-ray localization model significantly improved the useful field-of-view(UFOV)from 60.32 to 93.44%compared to the classical centroid localization methods.Additionally,the signal-to-noise ratio of the reconstructed images increased from 0.95 to 5.63.
基金the support for this work from the National Key R&D Program of China under Grant No.2018YFA0404204the National Natural Science Foundation of China(NSFC U1931113 and U1738211)+1 种基金the Foundations of Yunnan Province(2018IC059 and 2018FY001(-003))the scientific research fund of Yunnan Education Department(2020Y0039)。
文摘The unknown γ-ray excess in the northwest region of Arp 220 was revisited by analyzing~11.8 years of the Fermi Large Area Telescope(Fermi-LAT) data in this study.We found that its photon flux was approximately three times higher than that of the previous study in the 0.2-100 GeV band,and the corresponding significance level ~8.15σ was approximately four times higher than before.The light curves of 15 and 45 time bins from the whole time all showed two active periods,and the variability of the second period was more significant than that of the first period.The spectral indices from the two active periods were not statistically different and were close to the range of γ-ray flat-spectrum radio quasars observed by Fermi-LAT.Because the position of CRATES J153246+234400 was consistent with the best-fit position of our analysis,we suggest that CRATES J153246+234400 is more likely a γ-ray counterpart for the variational region.For Arp 220,there was no significant variability in the γ-ray emission.
基金National Natural Science Foundation of China(11805269)West Light Talent Training Plan of the Chinese Academy of Sciences(2022-XBQNXZ-010)Science and Technology Innovation Leading Talent Project of Xinjiang Uygur Autonomous Region(2022TSYCLJ0042)。
文摘Theγ-rays are widely and abundantly present in strong nuclear radiation environments,and when they act on the camera equipment used to obtain environmental visual information on nuclear robots,radiation effects will occur,which will degrade the performance of the camera system,reduce the imaging quality,and even cause catastrophic consequences.Color reducibility is an important index for evaluating the imaging quality of color camera,but its degradation mechanism in a nuclear radiation environment is still unclear.In this paper,theγ-ray irradiation experiments of CMOS cameras were carried out to analyse the degradation law of the camera’s color reducibility with cumulative irradiation and reveal the degradation mechanism of the color information of the CMOS camera underγ-ray irradiation.The results show that the spectral response of CMOS image sensor(CIS)and the spectral transmittance of lens after irradiation affect the values of a^(*)and b^(*)in the LAB color model.While the full well capacity(FWC)of CIS and transmittance of lens affect the value of L^(*)in the LAB color model,thus increase color difference and reduce brightness,the combined effect of color difference and brightness degradation will reduce the color reducibility of CMOS cameras.Therefore,the degradation of the color information of the CMOS camera afterγ-ray irradiation mainly comes from the changes in the FWC and spectral response of CIS,and the spectral transmittance of lens.
文摘In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.
文摘Taking a propfan engine as the research object,the CFD method was used for 3D modeling and unsteady slip flow for numerical calculation.The propfan rotation domain and the nacelle outside flow domain were meshed by using the partition splicing grid technology.Used the Reynolds⁃averaged of N⁃S equation,the Reynolds stress term uses the RNG turbulence model;and based on the slip grid method,numerical calculation of the flow field with different Mach numbers,front and rear blade angles and engine state were carried out;and the change law of propeller fan characteristics and the influence of slip flow on the inlet flow field were analyzed.The blade angle was the key parameter of the propeller fan characteristic conditions.When the blade angle increases from 41°to 50°,the thrust coefficient increases by 31.2%,and the power coefficient increases by 33.4%;in the climbing state of the propeller fan,the maximum total pressure distortion at the inlet port of 6.8%;the cross section is less affected by the slip flow of the propfan;and the pressure distribution is relatively uniform,but the area of the flow channel is small.The research results can provide a solution for the matching of the counter⁃rotating propeller fan and the engine and the arrangement of the air inlet measuring rake.