In order to solve the problem that the testing cost of the three-dimensional integrated circuit(3D IC)is too high,an optimal stacking order scheme is proposed to reduce the mid-bond test cost.A new testing model is bu...In order to solve the problem that the testing cost of the three-dimensional integrated circuit(3D IC)is too high,an optimal stacking order scheme is proposed to reduce the mid-bond test cost.A new testing model is built with the general consideration of both the test time for automatic test equipment(ATE)and manufacturing failure factors.An algorithm for testing cost and testing order optimization is proposed,and the minimum testing cost and optimized stacking order can be carried out by taking testing bandwidth and testing power as constraints.To prove the influence of the optimal stacking order on testing costs,two baselines stacked in sequential either in pyramid type or in inverted pyramid type are compared.Based on the benchmarks from ITC 02,experimental results show that for a 5-layer 3D IC,under different constraints,the optimal stacking order can reduce the test costs on average by 13%and 62%,respectively,compared to the pyramid type and inverted pyramid type.Furthermore,with the increase of the stack size,the test costs of the optimized stack order can be decreased.展开更多
The miniaturized disk bend test(MDBT) can be used to measure the fracture toughness at “infinite" crack length, K ∞, of ordered intermetallic compounds. The specimens tested are disks 3 mm in diameter and typic...The miniaturized disk bend test(MDBT) can be used to measure the fracture toughness at “infinite" crack length, K ∞, of ordered intermetallic compounds. The specimens tested are disks 3 mm in diameter and typically range in thickness from 250 to 400 μm. A Vickers indentation is impressed within ±10 μm of the center of a metallographically polished disk under a known load, F . The specimen is then subjected to biaxial loading, with the indented side in tension, and tested to failure. In completely brittle intermetallics the fracture stress, σ f, is calculated using a standard formula and measured experimentally as a function of F . When plasticity intervenes prior to fracture it is necessary to calculate the stress using finite element modeling (FEM), the FEM program NIKE2D has been used. Whether or not the specimens deform plastically, the resulting data on σ f vs F are analyzed using established equations of fracture mechanics in conjunction with an empirical rising R curve equation that characterizes the increase in fracture resistance, K R( c ), with crack length, c . Results are presented on several ordered intermetallic compounds. These include Ni 3Ge and Ti 5Si 3, which exhibit no ductility prior to fracture, and NiAl and a complex TiAl alloy, which both exhibit limited ductility before fracturing. The values of K ∞ determined with the MDBT are in very good agreement with values of K IC measured using conventional methods.展开更多
Consider I pairs of independent binomial variates x0i and x1i with corresponding parameters P0i and p1i and sample sizes n0i and n1i for i=1, …,I. Let △i = P1i-P0i be the difference of the two binomial parameters, w...Consider I pairs of independent binomial variates x0i and x1i with corresponding parameters P0i and p1i and sample sizes n0i and n1i for i=1, …,I. Let △i = P1i-P0i be the difference of the two binomial parameters, where △i’s are to be of interest and P0i’s are nuisance parameters. The null hypothesis of homogeneity on the risk difference can be written as展开更多
The overuse of clinical laboratory services has been documented for many years. This overuse use does not contribute to the quality of medical care, does not shorten hospital stay, nor reduce mortality. The utilizatio...The overuse of clinical laboratory services has been documented for many years. This overuse use does not contribute to the quality of medical care, does not shorten hospital stay, nor reduce mortality. The utilization of diagnostic laboratories has increased over the last decade around the world. This increased laboratory use is appropriate if it allows accurate diagnoses to be made, ideal treatment to be identified and monitored, accurate prognoses to be established, and patients’ hospital stays to be shortened. Thus, improving the appropriateness of testing behavior and reducing the number of laboratory tests have been recognized as essential parts of quality improvement program. In this study, the effectiveness of a computer-based system in improving the laboratory test-ordering in a general hospital was investigated. The study was conducted through four stages, the preparation stage, the pre-intervention stage, the post-intervention 1) stage and post-intervention 2) stage. Guideline and computer system were developed during preparation stage. Medical records were reviewed against guideline recommendations before any intervention during the pre-intervention stage, after guideline dissemination through educational workshops during the post intervention 1) stage, and after implementation of the computer system with the new requesting form during the post intervention 2) stage. The study revealed that the computer-based system achieved a statistically significant increase in the percentage of appropriate use from 44.6% in the post-intervention 1) stage to 55.6%, and a statistically significant increase in the compliance with guideline by prescriber as well as increased in guideline conformity rate from 16.7% in the post-intervention 1) stage to 32.5% in the post-intervention 2) stage, and decreased in the percentage of prescribers whose level was unsatisfactory from 85.4% the post-intervention 1) stage to 66.7% in the post-intervention 2) stage.展开更多
Mixed models provide a wide range of applications including hierarchical modeling and longitudinal studies. The tests of variance component in mixed models have long been a methodological challenge because of its boun...Mixed models provide a wide range of applications including hierarchical modeling and longitudinal studies. The tests of variance component in mixed models have long been a methodological challenge because of its boundary conditions. It is well documented in literature that the traditional first-order methods: likelihood ratio statistic, Wald statistic and score statistic, provide an excessively conservative approximation to the null distribution. However, the magnitude of the conservativeness has not been thoroughly explored. In this paper, we propose a likelihood-based third-order method to the mixed models for testing the null hypothesis of zero and non-zero variance component. The proposed method dramatically improved the accuracy of the tests. Extensive simulations were carried out to demonstrate the accuracy of the proposed method in comparison with the standard first-order methods. The results show the conservativeness of the first order methods and the accuracy of the proposed method in approximating the p-values and confidence intervals even when the sample size is small.展开更多
A complex autonomous inventory coupled system is considered. It can take, for example, the form of a network of chemical or biochemical reactors, where the inventory interactions perform the recycling of by-products b...A complex autonomous inventory coupled system is considered. It can take, for example, the form of a network of chemical or biochemical reactors, where the inventory interactions perform the recycling of by-products between the subsystems. Because of the flexible subsystems interactions, each of them can be operated with their own periods utilizing advantageously their dynamic properties. A multifrequency second-order test generalizing the p-test for single systems is described. It can be used to decide which kind of the operation (the static one, the periodic one or the multiperiodic one) will intensify the productivity of a complex system. An illustrative example of the multiperiodic optimization of a complex chemical production system is presented.展开更多
Background: Bivariate count data are commonly encountered in medicine, biology, engineering, epidemiology and many other applications. The Poisson distribution has been the model of choice to analyze such data. In mos...Background: Bivariate count data are commonly encountered in medicine, biology, engineering, epidemiology and many other applications. The Poisson distribution has been the model of choice to analyze such data. In most cases mutual independence among the variables is assumed, however this fails to take into accounts the correlation between the outcomes of interests. A special bivariate form of the multivariate Lagrange family of distribution, names Generalized Bivariate Poisson Distribution, is considered in this paper. Objectives: We estimate the model parameters using the method of maximum likelihood and show that the model fits the count variables representing components of metabolic syndrome in spousal pairs. We use the likelihood local score to test the significance of the correlation between the counts. We also construct confidence interval on the ratio of the two correlated Poisson means. Methods: Based on a random sample of pairs of count data, we show that the score test of independence is locally most powerful. We also provide a formula for sample size estimation for given level of significance and given power. The confidence intervals on the ratio of correlated Poisson means are constructed using the delta method, the Fieller’s theorem, and the nonparametric bootstrap. We illustrate the methodologies on metabolic syndrome data collected from 4000 spousal pairs. Results: The bivariate Poisson model fitted the metabolic syndrome data quite satisfactorily. Moreover, the three methods of confidence interval estimation were almost identical, meaning that they have the same interval width.展开更多
基金The National Natural Science Foundation of China(No.61674048,61574052,61474036,61371025)the Project of Anhui Institute of Economics and Management(No.YJKT1417T01)
文摘In order to solve the problem that the testing cost of the three-dimensional integrated circuit(3D IC)is too high,an optimal stacking order scheme is proposed to reduce the mid-bond test cost.A new testing model is built with the general consideration of both the test time for automatic test equipment(ATE)and manufacturing failure factors.An algorithm for testing cost and testing order optimization is proposed,and the minimum testing cost and optimized stacking order can be carried out by taking testing bandwidth and testing power as constraints.To prove the influence of the optimal stacking order on testing costs,two baselines stacked in sequential either in pyramid type or in inverted pyramid type are compared.Based on the benchmarks from ITC 02,experimental results show that for a 5-layer 3D IC,under different constraints,the optimal stacking order can reduce the test costs on average by 13%and 62%,respectively,compared to the pyramid type and inverted pyramid type.Furthermore,with the increase of the stack size,the test costs of the optimized stack order can be decreased.
文摘The miniaturized disk bend test(MDBT) can be used to measure the fracture toughness at “infinite" crack length, K ∞, of ordered intermetallic compounds. The specimens tested are disks 3 mm in diameter and typically range in thickness from 250 to 400 μm. A Vickers indentation is impressed within ±10 μm of the center of a metallographically polished disk under a known load, F . The specimen is then subjected to biaxial loading, with the indented side in tension, and tested to failure. In completely brittle intermetallics the fracture stress, σ f, is calculated using a standard formula and measured experimentally as a function of F . When plasticity intervenes prior to fracture it is necessary to calculate the stress using finite element modeling (FEM), the FEM program NIKE2D has been used. Whether or not the specimens deform plastically, the resulting data on σ f vs F are analyzed using established equations of fracture mechanics in conjunction with an empirical rising R curve equation that characterizes the increase in fracture resistance, K R( c ), with crack length, c . Results are presented on several ordered intermetallic compounds. These include Ni 3Ge and Ti 5Si 3, which exhibit no ductility prior to fracture, and NiAl and a complex TiAl alloy, which both exhibit limited ductility before fracturing. The values of K ∞ determined with the MDBT are in very good agreement with values of K IC measured using conventional methods.
文摘Consider I pairs of independent binomial variates x0i and x1i with corresponding parameters P0i and p1i and sample sizes n0i and n1i for i=1, …,I. Let △i = P1i-P0i be the difference of the two binomial parameters, where △i’s are to be of interest and P0i’s are nuisance parameters. The null hypothesis of homogeneity on the risk difference can be written as
文摘The overuse of clinical laboratory services has been documented for many years. This overuse use does not contribute to the quality of medical care, does not shorten hospital stay, nor reduce mortality. The utilization of diagnostic laboratories has increased over the last decade around the world. This increased laboratory use is appropriate if it allows accurate diagnoses to be made, ideal treatment to be identified and monitored, accurate prognoses to be established, and patients’ hospital stays to be shortened. Thus, improving the appropriateness of testing behavior and reducing the number of laboratory tests have been recognized as essential parts of quality improvement program. In this study, the effectiveness of a computer-based system in improving the laboratory test-ordering in a general hospital was investigated. The study was conducted through four stages, the preparation stage, the pre-intervention stage, the post-intervention 1) stage and post-intervention 2) stage. Guideline and computer system were developed during preparation stage. Medical records were reviewed against guideline recommendations before any intervention during the pre-intervention stage, after guideline dissemination through educational workshops during the post intervention 1) stage, and after implementation of the computer system with the new requesting form during the post intervention 2) stage. The study revealed that the computer-based system achieved a statistically significant increase in the percentage of appropriate use from 44.6% in the post-intervention 1) stage to 55.6%, and a statistically significant increase in the compliance with guideline by prescriber as well as increased in guideline conformity rate from 16.7% in the post-intervention 1) stage to 32.5% in the post-intervention 2) stage, and decreased in the percentage of prescribers whose level was unsatisfactory from 85.4% the post-intervention 1) stage to 66.7% in the post-intervention 2) stage.
文摘Mixed models provide a wide range of applications including hierarchical modeling and longitudinal studies. The tests of variance component in mixed models have long been a methodological challenge because of its boundary conditions. It is well documented in literature that the traditional first-order methods: likelihood ratio statistic, Wald statistic and score statistic, provide an excessively conservative approximation to the null distribution. However, the magnitude of the conservativeness has not been thoroughly explored. In this paper, we propose a likelihood-based third-order method to the mixed models for testing the null hypothesis of zero and non-zero variance component. The proposed method dramatically improved the accuracy of the tests. Extensive simulations were carried out to demonstrate the accuracy of the proposed method in comparison with the standard first-order methods. The results show the conservativeness of the first order methods and the accuracy of the proposed method in approximating the p-values and confidence intervals even when the sample size is small.
文摘A complex autonomous inventory coupled system is considered. It can take, for example, the form of a network of chemical or biochemical reactors, where the inventory interactions perform the recycling of by-products between the subsystems. Because of the flexible subsystems interactions, each of them can be operated with their own periods utilizing advantageously their dynamic properties. A multifrequency second-order test generalizing the p-test for single systems is described. It can be used to decide which kind of the operation (the static one, the periodic one or the multiperiodic one) will intensify the productivity of a complex system. An illustrative example of the multiperiodic optimization of a complex chemical production system is presented.
文摘Background: Bivariate count data are commonly encountered in medicine, biology, engineering, epidemiology and many other applications. The Poisson distribution has been the model of choice to analyze such data. In most cases mutual independence among the variables is assumed, however this fails to take into accounts the correlation between the outcomes of interests. A special bivariate form of the multivariate Lagrange family of distribution, names Generalized Bivariate Poisson Distribution, is considered in this paper. Objectives: We estimate the model parameters using the method of maximum likelihood and show that the model fits the count variables representing components of metabolic syndrome in spousal pairs. We use the likelihood local score to test the significance of the correlation between the counts. We also construct confidence interval on the ratio of the two correlated Poisson means. Methods: Based on a random sample of pairs of count data, we show that the score test of independence is locally most powerful. We also provide a formula for sample size estimation for given level of significance and given power. The confidence intervals on the ratio of correlated Poisson means are constructed using the delta method, the Fieller’s theorem, and the nonparametric bootstrap. We illustrate the methodologies on metabolic syndrome data collected from 4000 spousal pairs. Results: The bivariate Poisson model fitted the metabolic syndrome data quite satisfactorily. Moreover, the three methods of confidence interval estimation were almost identical, meaning that they have the same interval width.