As a complement to X-ray computed tomography(CT),neutron tomography has been extensively used in nuclear engineer-ing,materials science,cultural heritage,and industrial applications.Reconstruction of the attenuation m...As a complement to X-ray computed tomography(CT),neutron tomography has been extensively used in nuclear engineer-ing,materials science,cultural heritage,and industrial applications.Reconstruction of the attenuation matrix for neutron tomography with a traditional analytical algorithm requires hundreds of projection views in the range of 0°to 180°and typically takes several hours to complete.Such a low time-resolved resolution degrades the quality of neutron imaging.Decreasing the number of projection acquisitions is an important approach to improve the time resolution of images;however,this requires efficient reconstruction algorithms.Therefore,sparse-view reconstruction algorithms in neutron tomography need to be investigated.In this study,we investigated the three-dimensional reconstruction algorithm for sparse-view neu-tron CT scans.To enhance the reconstructed image quality of neutron CT,we propose an algorithm that uses OS-SART to reconstruct images and a split Bregman to solve for the total variation(SBTV).A comparative analysis of the performances of each reconstruction algorithm was performed using simulated and actual experimental data.According to the analyzed results,OS-SART-SBTV is superior to the other algorithms in terms of denoising,suppressing artifacts,and preserving detailed structural information of images.展开更多
Three-dimensional(3D) synthetic aperture radar(SAR)extends the conventional 2D images into 3D features by several acquisitions in different aspects. Compared with 3D techniques via multiple observations in elevation, ...Three-dimensional(3D) synthetic aperture radar(SAR)extends the conventional 2D images into 3D features by several acquisitions in different aspects. Compared with 3D techniques via multiple observations in elevation, e.g. SAR interferometry(InSAR) and SAR tomography(TomoSAR), holographic SAR can retrieve 3D structure by observations in azimuth. This paper focuses on designing a novel type of orbit to achieve SAR regional all-azimuth observation(AAO) for embedded targets detection and holographic 3D reconstruction. The ground tracks of the AAO orbit separate the earth surface into grids. Target in these grids can be accessed with an azimuth angle span of360°, which is similar to the flight path of airborne circular SAR(CSAR). Inspired from the successive coverage orbits of optical sensors, several optimizations are made in the proposed method to ensure favorable grazing angles, the performance of 3D reconstruction, and long-term supervision for SAR sensors. Simulation experiments show the regional AAO can be completed within five hours. In addition, a second AAO of the same area can be duplicated in two days. Finally, an airborne SAR data process result is presented to illustrate the significance of AAO in 3D reconstruction.展开更多
BACKGROUND Laparoscopic low anterior resection(LLAR)has become a mainstream surgical method for the treatment of colorectal cancer,which has shown many advantages in the aspects of surgical trauma and postoperative re...BACKGROUND Laparoscopic low anterior resection(LLAR)has become a mainstream surgical method for the treatment of colorectal cancer,which has shown many advantages in the aspects of surgical trauma and postoperative rehabilitation.However,the effect of surgery on patients'left coronary artery and its vascular reconstruction have not been deeply discussed.With the development of medical imaging technology,3D vascular reconstruction has become an effective means to evaluate the curative effect of surgery.AIM To investigate the clinical value of preoperative 3D vascular reconstruction in LLAR of rectal cancer with the left colic artery(LCA)preserved.METHODS A retrospective cohort study was performed to analyze the clinical data of 146 patients who underwent LLAR for rectal cancer with LCA preservation from January to December 2023 in our hospital.All patients underwent LLAR of rectal cancer with the LCA preserved,and the intraoperative and postoperative data were complete.The patients were divided into a reconstruction group(72 patients)and a nonreconstruction group(74 patients)according to whether 3D vascular reconstruction was performed before surgery.The clinical features,operation conditions,complications,pathological results and postoperative recovery of the two groups were collected and compared.RESULTS A total of 146 patients with rectal cancer were included in the study,including 72 patients in the reconstruction group and 74 patients in the nonreconstruction group.There were 47 males and 25 females in the reconstruction group,aged(59.75±6.2)years,with a body mass index(BMI)(24.1±2.2)kg/m^(2),and 51 males and 23 females in the nonreconstruction group,aged(58.77±6.1)years,with a BMI(23.6±2.7)kg/m^(2).There was no significant difference in the baseline data between the two groups(P>0.05).In the submesenteric artery reconstruction group,35 patients were type Ⅰ,25 patients were type Ⅱ,11 patients were type Ⅲ,and 1 patient was type Ⅳ.There were 37 type Ⅰ patients,24 type Ⅱ patients,12 type Ⅲ patients,and 1 type Ⅳ patient in the nonreconstruction group.There was no significant difference in arterial typing between the two groups(P>0.05).The operation time of the reconstruction group was 162.2±10.8 min,and that of the nonreconstruction group was 197.9±19.1 min.Compared with that of the reconstruction group,the operation time of the two groups was shorter,and the difference was statistically significant(t=13.840,P<0.05).The amount of intraoperative blood loss was 30.4±20.0 mL in the reconstruction group and 61.2±26.4 mL in the nonreconstruction group.The amount of blood loss in the reconstruction group was less than that in the control group,and the difference was statistically significant(t=-7.930,P<0.05).The rates of anastomotic leakage(1.4%vs 1.4%,P=0.984),anastomotic hemorrhage(2.8%vs 4.1%,P=0.672),and postoperative hospital stay(6.8±0.7 d vs 7.0±0.7 d,P=0.141)were not significantly different between the two groups.CONCLUSION Preoperative 3D vascular reconstruction technology can shorten the operation time and reduce the amount of intraoperative blood loss.Preoperative 3D vascular reconstruction is recommended to provide an intraoperative reference for laparoscopic low anterior resection with LCA preservation.展开更多
Three-dimensional reconstruction technology plays an important role in indoor scenes by converting objects and structures in indoor environments into accurate 3D models using multi-view RGB images.It offers a wide ran...Three-dimensional reconstruction technology plays an important role in indoor scenes by converting objects and structures in indoor environments into accurate 3D models using multi-view RGB images.It offers a wide range of applications in fields such as virtual reality,augmented reality,indoor navigation,and game development.Existing methods based on multi-view RGB images have made significant progress in 3D reconstruction.These image-based reconstruction methods not only possess good expressive power and generalization performance,but also handle complex geometric shapes and textures effectively.Despite facing challenges such as lighting variations,occlusion,and texture loss in indoor scenes,these challenges can be effectively addressed through deep neural networks,neural implicit surface representations,and other techniques.The technology of indoor 3D reconstruction based on multi-view RGB images has a promising future.It not only provides immersive and interactive virtual experiences but also brings convenience and innovation to indoor navigation,interior design,and virtual tours.As the technology evolves,these image-based reconstruction methods will be further improved to provide higher quality and more accurate solutions to indoor scene reconstruction.展开更多
BACKGROUND: Split liver transplantation increases the number of grafts available for transplantation. Pre-recovery assessment of liver graft volume is essential for selecting suitable recipients. The purpose of this ...BACKGROUND: Split liver transplantation increases the number of grafts available for transplantation. Pre-recovery assessment of liver graft volume is essential for selecting suitable recipients. The purpose of this study was to determine the ability and feasibility of constructing a 3-D model to aid in surgical planning and to predict graft weight prior to an in situ division of the donor liver. METHODS: Over 11 months, 3-D volumetric reconstruction of 4 deceased donors was performed using Pathfinder Scout liver volumetric software. Demographic, laboratory, operative, perioperative and survival data for these patients along with donor demographic data were collected prospectively and analyzed retrospectively. RESULTS: The average predicted weight of the grafts from the adult donors obtained from an in situ split procedure were 1130 g (930-1458 g) for the extended right lobe donors and 312 g (222-396 g) for left lateral segment grafts. Actual adult graft weight was 92% of the predicted weight for both the extended right grafts and the left lateral segment grafts. The predicted and actual graft weights for the pediatric donors were 176 g and 210 g for the left lateral segment grafts and 308 g and 280 g for the extended right lobe grafts,respectively. All grafts were transplanted except for the right lobe from the pediatric donors due to the small graft weight.CONCLUSIONS: On-site volumetric assessment of donors provides useful information for the planning of an in situ split and for selection of recipients. This information may expand the donor pool to recipients previously felt to be unsuitable due to donor and/or recipient weight.展开更多
Accurate 3-dimensional(3-D)reconstruction technology for nondestructive testing based on digital radiography(DR)is of great importance for alleviating the drawbacks of the existing computed tomography(CT)-based method...Accurate 3-dimensional(3-D)reconstruction technology for nondestructive testing based on digital radiography(DR)is of great importance for alleviating the drawbacks of the existing computed tomography(CT)-based method.The commonly used Monte Carlo simulation method ensures well-performing imaging results for DR.However,for 3-D reconstruction,it is limited by its high time consumption.To solve this problem,this study proposes a parallel computing method to accelerate Monte Carlo simulation for projection images with a parallel interface and a specific DR application.The images are utilized for 3-D reconstruction of the test model.We verify the accuracy of parallel computing for DR and evaluate the performance of two parallel computing modes-multithreaded applications(G4-MT)and message-passing interfaces(G4-MPI)-by assessing parallel speedup and efficiency.This study explores the scalability of the hybrid G4-MPI and G4-MT modes.The results show that the two parallel computing modes can significantly reduce the Monte Carlo simulation time because the parallel speedup increment of Monte Carlo simulations can be considered linear growth,and the parallel efficiency is maintained at a high level.The hybrid mode has strong scalability,as the overall run time of the 180 simulations using 320 threads is 15.35 h with 10 billion particles emitted,and the parallel speedup can be up to 151.36.The 3-D reconstruction of the model is achieved based on the filtered back projection(FBP)algorithm using 180 projection images obtained with the hybrid G4-MPI and G4-MT.The quality of the reconstructed sliced images is satisfactory because the images can reflect the internal structure of the test model.This method is applied to a complex model,and the quality of the reconstructed images is evaluated.展开更多
A 3-D digital core describes the pore space microstructure of rocks. An X-ray micro CT scan is the most accurate and direct but costly method to obtain a 3-D digital core. In this study, we propose a hybrid method whi...A 3-D digital core describes the pore space microstructure of rocks. An X-ray micro CT scan is the most accurate and direct but costly method to obtain a 3-D digital core. In this study, we propose a hybrid method which combines sedimentation simulation and simulated annealing (SA) method to generate 3-D digital cores based on 2-D images of rocks. The method starts with the sedimentation simulation to build a 3-D digital core, which is the initial configuration for the SA method. We update the initial digital core using the SA method to match the auto-correlation function of the 2-D rock image and eventually build the final 3-D digital core. Compared with the typical SA method, the hybrid method has significantly reduced the computation time. Local porosity theory is applied to quantitatively compare the reconstructed 3-D digital cores with the X-ray micro CT 3-D images. The results indicate that the 3-D digital cores reconstructed by the hybrid method have homogeneity and geometric connectivity similar to those of the X-ray micro CT image. The formation factors and permeabilities of the reconstructed 3-D digital cores are estimated using the finite element method (FEM) and lattice Boltzmann method (LBM), respectively. The simulated results are in good agreement with the experimental measurements. Comparison of the simulation results suggests that the digital cores reconstructed by the hybrid method more closely reflect the true transport properties than the typical SA method alone.展开更多
This paper presents a method to reconstruct 3-D models of trees from terrestrial laser scan(TLS)point clouds.This method uses the weighted locally optimal projection(WLOP)and the AdTree method to reconstruct detailed ...This paper presents a method to reconstruct 3-D models of trees from terrestrial laser scan(TLS)point clouds.This method uses the weighted locally optimal projection(WLOP)and the AdTree method to reconstruct detailed 3-D tree models.To improve its representation accuracy,the WLOP algorithm is introduced to consolidate the point cloud.Its reconstruction accuracy is tested using a dataset of ten trees,and the one-sided Hausdorff distances between the input point clouds and the resulting 3-D models are measured.The experimental results show that the optimal projection modeling method has an average one-sided Hausdorff distance(mean)lower by 30.74%and 6.43%compared with AdTree and AdQSM methods,respectively.Furthermore,it has an average one-sided Hausdorff distance(RMS)lower by 29.95%and 12.28%compared with AdTree and AdQSM methods.Results show that the 3-D model generated fits closely to the input point cloud data and ensures a high geometrical accuracy.展开更多
AIM:To present the outcome of modified grid laser photocoagulation(GLP)in diffuse diabetic macular edema(DDME)in eyes without extrafoveal and/or vitreofoveal traction.METHODS:Inclusion criteria for the retrospective s...AIM:To present the outcome of modified grid laser photocoagulation(GLP)in diffuse diabetic macular edema(DDME)in eyes without extrafoveal and/or vitreofoveal traction.METHODS:Inclusion criteria for the retrospective study were DDME eyes of patients with typeⅡdiabetes mellitus that had≥4 months of follow-up following GLP.Only one eye per patient was analyzed.Using 3-D spectral-domain optical coherence tomography(3-D SDOCT),eyes that had either extrafoveal or vitreofoveal traction,or had been previously treated by an intravitreal medication(s)were excluded.Treated DDME eyes were divided into 4 groups:A)"Classic"DDME that involved the central macula;B)edema did not involve the macular center;C)eyes associated with central epiretinal membrane(ERM);D)DDME that was associated with macular capillary dropout≥2 disc-diameter(DD).RESULTS:GLP outcome in 35 DDME eyes after 4-24(mean,13.1±6.9)months was as follows:Group A)18eyes with"classic"DDME.Following one or 2(mean,1.2)GLP treatments,best-corrected visual acuity(BCVA)improved by 1-2 Snellen lines in 44.4%(8/18)of eyes,and worsened by 1 line in 11.1%(2/18).Central macular thickness(CMT)improved by 7%-49%(mean,26.6%)in77.8%(14/18)of eyes.Causes of CMT worsening(n=4)were commonly explainable,predominantly(n=3)associated with emergence of extrafoveal traction,5-9months post-GLP.Group B)GLP(s)in DDME that did not involve the macular center(n=6)resulted in improved BCVA by 1-2 lines in 2 eyes.However,the central macula became involved in the edema process after the GLP in 3(50%)eyes,associated with an emergence of extrafoveal traction in one of these eyes 4months following the GLP.Group C)GLP failed in all 5eyes associated with central ERM.Group D)GLP was of partial benefit in 2 of 6 treated eyes with macular capillary dropout≥2DD.CONCLUSION:Eyes with DDME that involved the macular center were found to achieve favourable outcomes after GLP(s)during mid-term follow-up,unless complicated pre-GLP or post-GLP by vltreoretinal interface abnormalities,often extrafoveal traction or ERM,or by capillary dropout≥2DD.Prospective studies with larger cohorts are required.展开更多
The soft measurement technology of flame temperature field is an efficient method to learn the combustion status in furnace. Generally, it reconstructs the temperature field in furnace through the image of flame, whic...The soft measurement technology of flame temperature field is an efficient method to learn the combustion status in furnace. Generally, it reconstructs the temperature field in furnace through the image of flame, which is a process to solve radiative inverse problem. In this paper, the flame of pulverized coal is considered as 3-D, absorbing, emitting, and anisotropically scattering non-gray medium. Through the study on inverse problem of radiative heat transfer, the temperature field in this kind of medium has been reconstructed. The mechanism of 3-D radiative heat transfer in a rectangular media, which is 2 m×3 m× 5 m and full of CO2, N2 and carbon particles, is studied with Monte Carlo method. The 3-D temperature field in this rectangular space is reconstructed and the influence of particles density profile is discussed.展开更多
This paper combines the least-square method and iteration method to get the fundamental matrix and develops a new evaluation function based on the epipolar geometry. During the iteration, with the evaluation function ...This paper combines the least-square method and iteration method to get the fundamental matrix and develops a new evaluation function based on the epipolar geometry. During the iteration, with the evaluation function as a measurment, the points which bring larger noise are deleted, and the points with smaller noise are retained, thus the precision of our method is increased. The experiment results indicate the new method is precise in calculation, stable in performance and resistant to noise.展开更多
A new method for reconstructing a 3-dimensional object from serial cross-sectionsis presented in this paper.The method is based on the principle of sampling and considersevery point in cross-sections as a sampling poi...A new method for reconstructing a 3-dimensional object from serial cross-sectionsis presented in this paper.The method is based on the principle of sampling and considersevery point in cross-sections as a sampling point and performs the interpolating of nonlinearfunction with these sampling points.Compared with other methods,this method has manyadvantages such as higher precision and fewer requested known sampling points.The result ofreconstruction with this method is an“entity”which involves the exterior shape and interiorconstruction information of the object simultaneously.展开更多
Nickel-rich transition-metal oxides are widely regarded as promising cathode materials for high-energydensity lithium-ion batteries for emerging electric vehicles. However, achieving high energy density in Ni-rich cat...Nickel-rich transition-metal oxides are widely regarded as promising cathode materials for high-energydensity lithium-ion batteries for emerging electric vehicles. However, achieving high energy density in Ni-rich cathodes is accompanied by substantial safety and cycle-life obstacles. The major issues of Ni-rich cathodes at high working potentials are originated from the unstable cathode-electrolyte interface, while the underlying mechanism of parasitic reactions towards surface reconstructions of cathode materials is not well understood. In this work, we controlled the Li_(2)CO_(3) impurity content on LiNi_(0.83)Mn_(0.1)Co_(0.07)O_(2) cathodes using air, tank-air, and O_(2) synthesis environments. Home-built high-precision leakage current and on-line electrochemical mass spectroscopy experiments verify that Li_(2)CO_(3) impurity is a significant promoter of parasitic reactions on Ni-rich cathodes. The rate of parasitic reactions is strongly correlated to Li_(2)CO_(3) content and severe performance deterioration of Ni83 cathodes.The post-mortem characterizations via high-resolution transition electron microscope and X-ray photoelectron spectroscopy depth profiles reveal that parasitic reactions promote more Ni reduction and O deficiency and even rock-salt phase transformation at the surface of cathode materials. Our observation suggests that surface reconstructions have a strong affiliation to parasitic reactions that create chemically acidic environment to etch away the lattice oxygen and offer the electrical charge to reduce the valence state of transition metal. Thus, this study advances our understanding on surface reconstructions of Nirich cathodes and prepares us for searching for rational strategies.展开更多
目的探讨(1-3)-β-D葡聚糖联合降钙素原(procalcitonin,PCT)、CD4^(+)T淋巴细胞多指标在艾滋病患者马尔尼菲篮状菌感染早期诊断临床研究。方法回顾性选取我院2020年1月—2022年6月住院的120例艾滋病患者为研究对象。依据实验室结果,将...目的探讨(1-3)-β-D葡聚糖联合降钙素原(procalcitonin,PCT)、CD4^(+)T淋巴细胞多指标在艾滋病患者马尔尼菲篮状菌感染早期诊断临床研究。方法回顾性选取我院2020年1月—2022年6月住院的120例艾滋病患者为研究对象。依据实验室结果,将其分为马尔尼菲篮状菌感染确诊组(血或组织液培育养出马尔尼菲篮状菌),简称A组(62例),及马尔尼菲篮状菌感染临床诊断组[根据临床症状、体征、血常规及(1-3)-β-D葡聚糖、PCT、CD4^(+)T淋巴细胞多指标诊断],简称B组(58例)。检测患者(1-3)-β-D葡聚糖、PCT、CD4^(+)T淋巴细胞的表达水平,采用受试者工作特征(receiver-operating characteristic,ROC)曲线下面积(area under the curve,AUC)评估上述指标联合检测对艾滋病患者感染马尔尼菲篮状菌的诊断效能。结果A组的(1-3)-β-D葡聚糖和PCT水平均高于B组,CD4^(+)T淋巴细胞个数低于B组(P<0.05);(1-3)-β-D葡聚糖、PCT、CD4^(+)T淋巴细胞联合检测的AUC为0.933,(1-3)-β-D葡聚糖单独检测的AUC是0.812,PCT单独检测的AUC为0.883,CD4^(+)T淋巴细胞单独检测的AUC是0.810,(1-3)-β-D葡聚糖、PCT和CD4^(+)T淋巴细胞联合检测的AUC皆优于三项单独检测,表明(1-3)-β-D葡聚糖、PCT和CD4^(+)T淋巴细胞联合检测的诊断价值皆优于单一指标诊断,且联合检测的特异度、约登指数分别为92.43%和0.580,均高于三项单独检测。结论(1-3)-β-D葡聚糖联合PCT和CD4^(+)T淋巴细胞多指标对艾滋病马尔尼菲篮状菌感染具有非常高的临床诊断价值,能够帮助医生分析出高危风险患者,及时制定治疗方案,同时也承担预后效果的判断依据,对治疗艾滋病马尔尼菲篮状菌感染具有非常重要的研究价值。展开更多
In order to solve the dynamic reconstruction and local updating problem of three-dimensional geological solids, topology reasoning is used for three-dimensional geological modeling. This can advance the level of the c...In order to solve the dynamic reconstruction and local updating problem of three-dimensional geological solids, topology reasoning is used for three-dimensional geological modeling. This can advance the level of the corresponding section automation in implementing the 3D geological solid dynamical reconstruction by the construction of and reasoning on topology on the 3D curved surface. This method has been successfully used in the Nanjing city geological modeling and the Zijin gold mine modeling. The results prove that this method adapts to coplanar section and noncoplanar section data, and improves the efficiency of 3D geological modeling.展开更多
The bone regenerative scaffold with the tailored degradation rate matching with the growth rate of the new bone is essential for adolescent bone repair.To satisfy these requirement,we proposed bone tissue scaffolds wi...The bone regenerative scaffold with the tailored degradation rate matching with the growth rate of the new bone is essential for adolescent bone repair.To satisfy these requirement,we proposed bone tissue scaffolds with controlled degradation rate using osteoinductive materials(Ca-P bioceramics),which is expected to present a controllable biodegradation rate for patients who need bone regeneration.Physicochemical properties,porosity,compressive strength and degradation properties of the scaffolds were studied.3D printed Ca-P scaffold(3DS),gas foaming Ca-P scaffold(FS)and autogenous bone(AB)were used in vivo for personalized beagle skull defect repair.Histological results indicated that the 3DS was highly vascularized and well combined with surrounding tissues.FS showed obvious newly formed bone tissues.AB showed the best repair effect,but it was found that AB scaffolds were partially absorbed and degraded.This study indicated that the 3D printed Ca-P bioceramics with tailored biodegradation rate is a promising candidate for personalized skull bone tissue reconstruction.展开更多
The borescopy inspection problem of aeroengine interior important partdamages such as firebox's burn and corruption, vane' s crack, bump, abrade and concave pit, is aimedat. A new system is developed to carry ...The borescopy inspection problem of aeroengine interior important partdamages such as firebox's burn and corruption, vane' s crack, bump, abrade and concave pit, is aimedat. A new system is developed to carry out 3D measurement and stereo reconstruction of engineinterior damage, in which the borescope of Japanese OLYMPUS Corporation is used as hardware. In thesystem, functions are implemented, such as image collection, camera calibration, imagepreprocessing, stereo matching, 3D measurement and stereo reconstruction. It can provide moredetailed inspection and more accurate estimation of engine interior damages. Finally, an example isused to verify the effectivity of the new method.展开更多
A novel technique of three-dimensional (3D) reconstruction, segmentation, display and analysis of series slices of images including microscopic wide field optical sectioning by deconvolution method, cryo-electron micr...A novel technique of three-dimensional (3D) reconstruction, segmentation, display and analysis of series slices of images including microscopic wide field optical sectioning by deconvolution method, cryo-electron microscope slices by Fou-rier-Bessel synthesis and electron tomography (ET), and a series of computed tomography (CT) was developed to perform si-multaneous measurement on the structure and function of biomedical samples. The paper presents the 3D reconstruction seg-mentation display and analysis results of pollen spore, chaperonin, virus, head, cervical bone, tibia and carpus. At the same time, it also puts forward some potential applications of the new technique in the biomedical realm.展开更多
Complicated and large acetabular bone defects present the main challenges and difficulty in the revision of total hip arthroplasty(THA).This study aimed to explore the advantages of three-dimensional(3D)printing techn...Complicated and large acetabular bone defects present the main challenges and difficulty in the revision of total hip arthroplasty(THA).This study aimed to explore the advantages of three-dimensional(3D)printing technology in the reconstruction of such acetabular bone defects.We retrospectively analyzed the prognosis of four severe bone defects around the acetabulum in three patients who were treated using 3D printing technology.Reconstruction of bone defect by conventional methods was difficult in these patients.In this endeavor,we used radiographic methods,related computer software such as Materialise's interactive medical image control system and Siemens NX software,and actual surgical experience to estimate defect volume,prosthesis stability,and installation accuracy,respectively.Moreover,a Harris hip score was obtained to evaluate limb function.It was found that bone defects could be adequately reconstructed using a 3D printing prosthesis,and its stability was reliable.The Harris hip score indicated a very good functional recovery in all three patients.In conclusion,3D printing technology had a good therapeutic effect on both complex and large bone defects in the revision of THA.It was able to achieve good curative effects in patients with large bone defects.展开更多
基金supported by the National Key Research and Development Program of China(No.2022YFB1902700)the National Natural Science Foundation of China(No.11875129)+3 种基金the Fund of the State Key Laboratory of Intense Pulsed Radiation Simulation and Effect(No.SKLIPR1810)the Fund of Innovation Center of Radiation Application(No.KFZC2020020402)the Fund of the State Key Laboratory of Nuclear Physics and Technology,Peking University(No.NPT2020KFY08)the Joint Innovation Fund of China National Uranium Co.,Ltd.,State Key Laboratory of Nuclear Resources and Environment,East China University of Technology(No.2022NRE-LH-02).
文摘As a complement to X-ray computed tomography(CT),neutron tomography has been extensively used in nuclear engineer-ing,materials science,cultural heritage,and industrial applications.Reconstruction of the attenuation matrix for neutron tomography with a traditional analytical algorithm requires hundreds of projection views in the range of 0°to 180°and typically takes several hours to complete.Such a low time-resolved resolution degrades the quality of neutron imaging.Decreasing the number of projection acquisitions is an important approach to improve the time resolution of images;however,this requires efficient reconstruction algorithms.Therefore,sparse-view reconstruction algorithms in neutron tomography need to be investigated.In this study,we investigated the three-dimensional reconstruction algorithm for sparse-view neu-tron CT scans.To enhance the reconstructed image quality of neutron CT,we propose an algorithm that uses OS-SART to reconstruct images and a split Bregman to solve for the total variation(SBTV).A comparative analysis of the performances of each reconstruction algorithm was performed using simulated and actual experimental data.According to the analyzed results,OS-SART-SBTV is superior to the other algorithms in terms of denoising,suppressing artifacts,and preserving detailed structural information of images.
基金supported by the National Natural Science Foundation of China (62001436)the Natural Science Foundation of Jiangsu Province under (BK 20190143,JSGG20190823094603691)。
文摘Three-dimensional(3D) synthetic aperture radar(SAR)extends the conventional 2D images into 3D features by several acquisitions in different aspects. Compared with 3D techniques via multiple observations in elevation, e.g. SAR interferometry(InSAR) and SAR tomography(TomoSAR), holographic SAR can retrieve 3D structure by observations in azimuth. This paper focuses on designing a novel type of orbit to achieve SAR regional all-azimuth observation(AAO) for embedded targets detection and holographic 3D reconstruction. The ground tracks of the AAO orbit separate the earth surface into grids. Target in these grids can be accessed with an azimuth angle span of360°, which is similar to the flight path of airborne circular SAR(CSAR). Inspired from the successive coverage orbits of optical sensors, several optimizations are made in the proposed method to ensure favorable grazing angles, the performance of 3D reconstruction, and long-term supervision for SAR sensors. Simulation experiments show the regional AAO can be completed within five hours. In addition, a second AAO of the same area can be duplicated in two days. Finally, an airborne SAR data process result is presented to illustrate the significance of AAO in 3D reconstruction.
文摘BACKGROUND Laparoscopic low anterior resection(LLAR)has become a mainstream surgical method for the treatment of colorectal cancer,which has shown many advantages in the aspects of surgical trauma and postoperative rehabilitation.However,the effect of surgery on patients'left coronary artery and its vascular reconstruction have not been deeply discussed.With the development of medical imaging technology,3D vascular reconstruction has become an effective means to evaluate the curative effect of surgery.AIM To investigate the clinical value of preoperative 3D vascular reconstruction in LLAR of rectal cancer with the left colic artery(LCA)preserved.METHODS A retrospective cohort study was performed to analyze the clinical data of 146 patients who underwent LLAR for rectal cancer with LCA preservation from January to December 2023 in our hospital.All patients underwent LLAR of rectal cancer with the LCA preserved,and the intraoperative and postoperative data were complete.The patients were divided into a reconstruction group(72 patients)and a nonreconstruction group(74 patients)according to whether 3D vascular reconstruction was performed before surgery.The clinical features,operation conditions,complications,pathological results and postoperative recovery of the two groups were collected and compared.RESULTS A total of 146 patients with rectal cancer were included in the study,including 72 patients in the reconstruction group and 74 patients in the nonreconstruction group.There were 47 males and 25 females in the reconstruction group,aged(59.75±6.2)years,with a body mass index(BMI)(24.1±2.2)kg/m^(2),and 51 males and 23 females in the nonreconstruction group,aged(58.77±6.1)years,with a BMI(23.6±2.7)kg/m^(2).There was no significant difference in the baseline data between the two groups(P>0.05).In the submesenteric artery reconstruction group,35 patients were type Ⅰ,25 patients were type Ⅱ,11 patients were type Ⅲ,and 1 patient was type Ⅳ.There were 37 type Ⅰ patients,24 type Ⅱ patients,12 type Ⅲ patients,and 1 type Ⅳ patient in the nonreconstruction group.There was no significant difference in arterial typing between the two groups(P>0.05).The operation time of the reconstruction group was 162.2±10.8 min,and that of the nonreconstruction group was 197.9±19.1 min.Compared with that of the reconstruction group,the operation time of the two groups was shorter,and the difference was statistically significant(t=13.840,P<0.05).The amount of intraoperative blood loss was 30.4±20.0 mL in the reconstruction group and 61.2±26.4 mL in the nonreconstruction group.The amount of blood loss in the reconstruction group was less than that in the control group,and the difference was statistically significant(t=-7.930,P<0.05).The rates of anastomotic leakage(1.4%vs 1.4%,P=0.984),anastomotic hemorrhage(2.8%vs 4.1%,P=0.672),and postoperative hospital stay(6.8±0.7 d vs 7.0±0.7 d,P=0.141)were not significantly different between the two groups.CONCLUSION Preoperative 3D vascular reconstruction technology can shorten the operation time and reduce the amount of intraoperative blood loss.Preoperative 3D vascular reconstruction is recommended to provide an intraoperative reference for laparoscopic low anterior resection with LCA preservation.
基金supported by ZTE Industry University Institute Cooperation Funds under Grant No.HCCN20221102002.
文摘Three-dimensional reconstruction technology plays an important role in indoor scenes by converting objects and structures in indoor environments into accurate 3D models using multi-view RGB images.It offers a wide range of applications in fields such as virtual reality,augmented reality,indoor navigation,and game development.Existing methods based on multi-view RGB images have made significant progress in 3D reconstruction.These image-based reconstruction methods not only possess good expressive power and generalization performance,but also handle complex geometric shapes and textures effectively.Despite facing challenges such as lighting variations,occlusion,and texture loss in indoor scenes,these challenges can be effectively addressed through deep neural networks,neural implicit surface representations,and other techniques.The technology of indoor 3D reconstruction based on multi-view RGB images has a promising future.It not only provides immersive and interactive virtual experiences but also brings convenience and innovation to indoor navigation,interior design,and virtual tours.As the technology evolves,these image-based reconstruction methods will be further improved to provide higher quality and more accurate solutions to indoor scene reconstruction.
文摘BACKGROUND: Split liver transplantation increases the number of grafts available for transplantation. Pre-recovery assessment of liver graft volume is essential for selecting suitable recipients. The purpose of this study was to determine the ability and feasibility of constructing a 3-D model to aid in surgical planning and to predict graft weight prior to an in situ division of the donor liver. METHODS: Over 11 months, 3-D volumetric reconstruction of 4 deceased donors was performed using Pathfinder Scout liver volumetric software. Demographic, laboratory, operative, perioperative and survival data for these patients along with donor demographic data were collected prospectively and analyzed retrospectively. RESULTS: The average predicted weight of the grafts from the adult donors obtained from an in situ split procedure were 1130 g (930-1458 g) for the extended right lobe donors and 312 g (222-396 g) for left lateral segment grafts. Actual adult graft weight was 92% of the predicted weight for both the extended right grafts and the left lateral segment grafts. The predicted and actual graft weights for the pediatric donors were 176 g and 210 g for the left lateral segment grafts and 308 g and 280 g for the extended right lobe grafts,respectively. All grafts were transplanted except for the right lobe from the pediatric donors due to the small graft weight.CONCLUSIONS: On-site volumetric assessment of donors provides useful information for the planning of an in situ split and for selection of recipients. This information may expand the donor pool to recipients previously felt to be unsuitable due to donor and/or recipient weight.
基金the China Natural Science Fund(No.52171253)the Natural Science Foundation of Sichuan(No.2022NSFSCO949).
文摘Accurate 3-dimensional(3-D)reconstruction technology for nondestructive testing based on digital radiography(DR)is of great importance for alleviating the drawbacks of the existing computed tomography(CT)-based method.The commonly used Monte Carlo simulation method ensures well-performing imaging results for DR.However,for 3-D reconstruction,it is limited by its high time consumption.To solve this problem,this study proposes a parallel computing method to accelerate Monte Carlo simulation for projection images with a parallel interface and a specific DR application.The images are utilized for 3-D reconstruction of the test model.We verify the accuracy of parallel computing for DR and evaluate the performance of two parallel computing modes-multithreaded applications(G4-MT)and message-passing interfaces(G4-MPI)-by assessing parallel speedup and efficiency.This study explores the scalability of the hybrid G4-MPI and G4-MT modes.The results show that the two parallel computing modes can significantly reduce the Monte Carlo simulation time because the parallel speedup increment of Monte Carlo simulations can be considered linear growth,and the parallel efficiency is maintained at a high level.The hybrid mode has strong scalability,as the overall run time of the 180 simulations using 320 threads is 15.35 h with 10 billion particles emitted,and the parallel speedup can be up to 151.36.The 3-D reconstruction of the model is achieved based on the filtered back projection(FBP)algorithm using 180 projection images obtained with the hybrid G4-MPI and G4-MT.The quality of the reconstructed sliced images is satisfactory because the images can reflect the internal structure of the test model.This method is applied to a complex model,and the quality of the reconstructed images is evaluated.
基金sponsored by NSFC(Grant No.40574030)CNPC Research Project(Grant No.06A30102)
文摘A 3-D digital core describes the pore space microstructure of rocks. An X-ray micro CT scan is the most accurate and direct but costly method to obtain a 3-D digital core. In this study, we propose a hybrid method which combines sedimentation simulation and simulated annealing (SA) method to generate 3-D digital cores based on 2-D images of rocks. The method starts with the sedimentation simulation to build a 3-D digital core, which is the initial configuration for the SA method. We update the initial digital core using the SA method to match the auto-correlation function of the 2-D rock image and eventually build the final 3-D digital core. Compared with the typical SA method, the hybrid method has significantly reduced the computation time. Local porosity theory is applied to quantitatively compare the reconstructed 3-D digital cores with the X-ray micro CT 3-D images. The results indicate that the 3-D digital cores reconstructed by the hybrid method have homogeneity and geometric connectivity similar to those of the X-ray micro CT image. The formation factors and permeabilities of the reconstructed 3-D digital cores are estimated using the finite element method (FEM) and lattice Boltzmann method (LBM), respectively. The simulated results are in good agreement with the experimental measurements. Comparison of the simulation results suggests that the digital cores reconstructed by the hybrid method more closely reflect the true transport properties than the typical SA method alone.
基金supported in part by the National Natural Science Foundation of China(Nos.42271343,42177387)the Fund of State Key Laboratory of Remote Sensing Information and Image Analysis Technology of Beijing Research Institute of Uranium Geology under(No.6142A010403)
文摘This paper presents a method to reconstruct 3-D models of trees from terrestrial laser scan(TLS)point clouds.This method uses the weighted locally optimal projection(WLOP)and the AdTree method to reconstruct detailed 3-D tree models.To improve its representation accuracy,the WLOP algorithm is introduced to consolidate the point cloud.Its reconstruction accuracy is tested using a dataset of ten trees,and the one-sided Hausdorff distances between the input point clouds and the resulting 3-D models are measured.The experimental results show that the optimal projection modeling method has an average one-sided Hausdorff distance(mean)lower by 30.74%and 6.43%compared with AdTree and AdQSM methods,respectively.Furthermore,it has an average one-sided Hausdorff distance(RMS)lower by 29.95%and 12.28%compared with AdTree and AdQSM methods.Results show that the 3-D model generated fits closely to the input point cloud data and ensures a high geometrical accuracy.
文摘AIM:To present the outcome of modified grid laser photocoagulation(GLP)in diffuse diabetic macular edema(DDME)in eyes without extrafoveal and/or vitreofoveal traction.METHODS:Inclusion criteria for the retrospective study were DDME eyes of patients with typeⅡdiabetes mellitus that had≥4 months of follow-up following GLP.Only one eye per patient was analyzed.Using 3-D spectral-domain optical coherence tomography(3-D SDOCT),eyes that had either extrafoveal or vitreofoveal traction,or had been previously treated by an intravitreal medication(s)were excluded.Treated DDME eyes were divided into 4 groups:A)"Classic"DDME that involved the central macula;B)edema did not involve the macular center;C)eyes associated with central epiretinal membrane(ERM);D)DDME that was associated with macular capillary dropout≥2 disc-diameter(DD).RESULTS:GLP outcome in 35 DDME eyes after 4-24(mean,13.1±6.9)months was as follows:Group A)18eyes with"classic"DDME.Following one or 2(mean,1.2)GLP treatments,best-corrected visual acuity(BCVA)improved by 1-2 Snellen lines in 44.4%(8/18)of eyes,and worsened by 1 line in 11.1%(2/18).Central macular thickness(CMT)improved by 7%-49%(mean,26.6%)in77.8%(14/18)of eyes.Causes of CMT worsening(n=4)were commonly explainable,predominantly(n=3)associated with emergence of extrafoveal traction,5-9months post-GLP.Group B)GLP(s)in DDME that did not involve the macular center(n=6)resulted in improved BCVA by 1-2 lines in 2 eyes.However,the central macula became involved in the edema process after the GLP in 3(50%)eyes,associated with an emergence of extrafoveal traction in one of these eyes 4months following the GLP.Group C)GLP failed in all 5eyes associated with central ERM.Group D)GLP was of partial benefit in 2 of 6 treated eyes with macular capillary dropout≥2DD.CONCLUSION:Eyes with DDME that involved the macular center were found to achieve favourable outcomes after GLP(s)during mid-term follow-up,unless complicated pre-GLP or post-GLP by vltreoretinal interface abnormalities,often extrafoveal traction or ERM,or by capillary dropout≥2DD.Prospective studies with larger cohorts are required.
基金Project Supported by National Nature Science Foundation of China (50578034) Science and Technology Development Foundation ofDonghua University
文摘The soft measurement technology of flame temperature field is an efficient method to learn the combustion status in furnace. Generally, it reconstructs the temperature field in furnace through the image of flame, which is a process to solve radiative inverse problem. In this paper, the flame of pulverized coal is considered as 3-D, absorbing, emitting, and anisotropically scattering non-gray medium. Through the study on inverse problem of radiative heat transfer, the temperature field in this kind of medium has been reconstructed. The mechanism of 3-D radiative heat transfer in a rectangular media, which is 2 m×3 m× 5 m and full of CO2, N2 and carbon particles, is studied with Monte Carlo method. The 3-D temperature field in this rectangular space is reconstructed and the influence of particles density profile is discussed.
基金Supported by the National Science Foundation(69275004)the France-China Advanced Research Program
文摘This paper combines the least-square method and iteration method to get the fundamental matrix and develops a new evaluation function based on the epipolar geometry. During the iteration, with the evaluation function as a measurment, the points which bring larger noise are deleted, and the points with smaller noise are retained, thus the precision of our method is increased. The experiment results indicate the new method is precise in calculation, stable in performance and resistant to noise.
文摘A new method for reconstructing a 3-dimensional object from serial cross-sectionsis presented in this paper.The method is based on the principle of sampling and considersevery point in cross-sections as a sampling point and performs the interpolating of nonlinearfunction with these sampling points.Compared with other methods,this method has manyadvantages such as higher precision and fewer requested known sampling points.The result ofreconstruction with this method is an“entity”which involves the exterior shape and interiorconstruction information of the object simultaneously.
基金supported by the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Officesupported by the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Advanced Manufacturing Office, under Contract No. DE-SC0012704+1 种基金supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract DE-AC02-06CH11357supported by the Vehicle Technologies Office of the U.S. Department of Energy。
文摘Nickel-rich transition-metal oxides are widely regarded as promising cathode materials for high-energydensity lithium-ion batteries for emerging electric vehicles. However, achieving high energy density in Ni-rich cathodes is accompanied by substantial safety and cycle-life obstacles. The major issues of Ni-rich cathodes at high working potentials are originated from the unstable cathode-electrolyte interface, while the underlying mechanism of parasitic reactions towards surface reconstructions of cathode materials is not well understood. In this work, we controlled the Li_(2)CO_(3) impurity content on LiNi_(0.83)Mn_(0.1)Co_(0.07)O_(2) cathodes using air, tank-air, and O_(2) synthesis environments. Home-built high-precision leakage current and on-line electrochemical mass spectroscopy experiments verify that Li_(2)CO_(3) impurity is a significant promoter of parasitic reactions on Ni-rich cathodes. The rate of parasitic reactions is strongly correlated to Li_(2)CO_(3) content and severe performance deterioration of Ni83 cathodes.The post-mortem characterizations via high-resolution transition electron microscope and X-ray photoelectron spectroscopy depth profiles reveal that parasitic reactions promote more Ni reduction and O deficiency and even rock-salt phase transformation at the surface of cathode materials. Our observation suggests that surface reconstructions have a strong affiliation to parasitic reactions that create chemically acidic environment to etch away the lattice oxygen and offer the electrical charge to reduce the valence state of transition metal. Thus, this study advances our understanding on surface reconstructions of Nirich cathodes and prepares us for searching for rational strategies.
文摘目的探讨(1-3)-β-D葡聚糖联合降钙素原(procalcitonin,PCT)、CD4^(+)T淋巴细胞多指标在艾滋病患者马尔尼菲篮状菌感染早期诊断临床研究。方法回顾性选取我院2020年1月—2022年6月住院的120例艾滋病患者为研究对象。依据实验室结果,将其分为马尔尼菲篮状菌感染确诊组(血或组织液培育养出马尔尼菲篮状菌),简称A组(62例),及马尔尼菲篮状菌感染临床诊断组[根据临床症状、体征、血常规及(1-3)-β-D葡聚糖、PCT、CD4^(+)T淋巴细胞多指标诊断],简称B组(58例)。检测患者(1-3)-β-D葡聚糖、PCT、CD4^(+)T淋巴细胞的表达水平,采用受试者工作特征(receiver-operating characteristic,ROC)曲线下面积(area under the curve,AUC)评估上述指标联合检测对艾滋病患者感染马尔尼菲篮状菌的诊断效能。结果A组的(1-3)-β-D葡聚糖和PCT水平均高于B组,CD4^(+)T淋巴细胞个数低于B组(P<0.05);(1-3)-β-D葡聚糖、PCT、CD4^(+)T淋巴细胞联合检测的AUC为0.933,(1-3)-β-D葡聚糖单独检测的AUC是0.812,PCT单独检测的AUC为0.883,CD4^(+)T淋巴细胞单独检测的AUC是0.810,(1-3)-β-D葡聚糖、PCT和CD4^(+)T淋巴细胞联合检测的AUC皆优于三项单独检测,表明(1-3)-β-D葡聚糖、PCT和CD4^(+)T淋巴细胞联合检测的诊断价值皆优于单一指标诊断,且联合检测的特异度、约登指数分别为92.43%和0.580,均高于三项单独检测。结论(1-3)-β-D葡聚糖联合PCT和CD4^(+)T淋巴细胞多指标对艾滋病马尔尼菲篮状菌感染具有非常高的临床诊断价值,能够帮助医生分析出高危风险患者,及时制定治疗方案,同时也承担预后效果的判断依据,对治疗艾滋病马尔尼菲篮状菌感染具有非常重要的研究价值。
基金the Research Foundation for Outstanding Young Teachers, China University of Geosciences.
文摘In order to solve the dynamic reconstruction and local updating problem of three-dimensional geological solids, topology reasoning is used for three-dimensional geological modeling. This can advance the level of the corresponding section automation in implementing the 3D geological solid dynamical reconstruction by the construction of and reasoning on topology on the 3D curved surface. This method has been successfully used in the Nanjing city geological modeling and the Zijin gold mine modeling. The results prove that this method adapts to coplanar section and noncoplanar section data, and improves the efficiency of 3D geological modeling.
基金This work was supported by the National Key Research and Development Program of China(No.18YFB1105600,2018YFC1106800)National Natural Science Foundation of China(51875518)+1 种基金Sichuan Province Science&Technology Department Projects(2016CZYD0004,2017SZ0001,2018GZ0142,2019YFH0079)Research Foundation for Young Teachers of Sichuan University(2018SCUH0017)and The“111”Project(No.B16033).
文摘The bone regenerative scaffold with the tailored degradation rate matching with the growth rate of the new bone is essential for adolescent bone repair.To satisfy these requirement,we proposed bone tissue scaffolds with controlled degradation rate using osteoinductive materials(Ca-P bioceramics),which is expected to present a controllable biodegradation rate for patients who need bone regeneration.Physicochemical properties,porosity,compressive strength and degradation properties of the scaffolds were studied.3D printed Ca-P scaffold(3DS),gas foaming Ca-P scaffold(FS)and autogenous bone(AB)were used in vivo for personalized beagle skull defect repair.Histological results indicated that the 3DS was highly vascularized and well combined with surrounding tissues.FS showed obvious newly formed bone tissues.AB showed the best repair effect,but it was found that AB scaffolds were partially absorbed and degraded.This study indicated that the 3D printed Ca-P bioceramics with tailored biodegradation rate is a promising candidate for personalized skull bone tissue reconstruction.
文摘The borescopy inspection problem of aeroengine interior important partdamages such as firebox's burn and corruption, vane' s crack, bump, abrade and concave pit, is aimedat. A new system is developed to carry out 3D measurement and stereo reconstruction of engineinterior damage, in which the borescope of Japanese OLYMPUS Corporation is used as hardware. In thesystem, functions are implemented, such as image collection, camera calibration, imagepreprocessing, stereo matching, 3D measurement and stereo reconstruction. It can provide moredetailed inspection and more accurate estimation of engine interior damages. Finally, an example isused to verify the effectivity of the new method.
文摘A novel technique of three-dimensional (3D) reconstruction, segmentation, display and analysis of series slices of images including microscopic wide field optical sectioning by deconvolution method, cryo-electron microscope slices by Fou-rier-Bessel synthesis and electron tomography (ET), and a series of computed tomography (CT) was developed to perform si-multaneous measurement on the structure and function of biomedical samples. The paper presents the 3D reconstruction seg-mentation display and analysis results of pollen spore, chaperonin, virus, head, cervical bone, tibia and carpus. At the same time, it also puts forward some potential applications of the new technique in the biomedical realm.
基金This work is supported by National Key Research and Development Program of China(2016YFC1100600)the National Natural Science Foundation of China(81972058 and 81902194)the Multicenter Clinical Research Project of Shanghai Jiao Tong University School of Medicine(DLY201506).
文摘Complicated and large acetabular bone defects present the main challenges and difficulty in the revision of total hip arthroplasty(THA).This study aimed to explore the advantages of three-dimensional(3D)printing technology in the reconstruction of such acetabular bone defects.We retrospectively analyzed the prognosis of four severe bone defects around the acetabulum in three patients who were treated using 3D printing technology.Reconstruction of bone defect by conventional methods was difficult in these patients.In this endeavor,we used radiographic methods,related computer software such as Materialise's interactive medical image control system and Siemens NX software,and actual surgical experience to estimate defect volume,prosthesis stability,and installation accuracy,respectively.Moreover,a Harris hip score was obtained to evaluate limb function.It was found that bone defects could be adequately reconstructed using a 3D printing prosthesis,and its stability was reliable.The Harris hip score indicated a very good functional recovery in all three patients.In conclusion,3D printing technology had a good therapeutic effect on both complex and large bone defects in the revision of THA.It was able to achieve good curative effects in patients with large bone defects.