This study examined the dynamic characteristics of upper airway collapse at soft palate level in patients with obstructive sleep apnea/hypopnea syndrome(OSAHS) by using dynamic 3-Dimensional(3-D) CT imaging.A tota...This study examined the dynamic characteristics of upper airway collapse at soft palate level in patients with obstructive sleep apnea/hypopnea syndrome(OSAHS) by using dynamic 3-Dimensional(3-D) CT imaging.A total of 41 male patients who presented with 2 of the following symptoms,i.e.,daytime sleepiness and fatigue,frequent snoring,and apnea with witness,were diagnosed as having OSAHS.They underwent full-night polysomnography and then dynamic 3-D CT imaging of the upper airway during quiet breathing and in Muller's maneuver.The soft palate length(SPL),the minimal cross-sectional area of the retropalatal region(mXSA-RP),and the vertical distance from the hard palate to the upper posterior part of the hyoid(hhL) were compared between the two breathing states.These parameters,together with hard palate length(HPL),were also compared between mild/moderate and severe OSAHS groups.Association of these parameters with the severity of OSAHS [as reflected by apnea hypopnea index(AHI) and the lowest saturation of blood oxygen(LSaO2)] was examined.The results showed that 31 patients had severe OSAHS,and 10 mild/moderate OSAHS.All the patients had airway obstruction at soft palate level.mXSA-RP was significantly decreased and SPL remarkably increased during Muller's maneuver as compared with the quiet breathing state.There were no significant differences in these airway parameters(except the position of the hyoid bone) between severe and mild/moderate OSAHS groups.And no significant correlation between these airway parameters and the severity of OSAHS was found.The position of hyoid was lower in the severe OSAHS group than in the mild/moderate OSAHS group.The patients in group with body mass index(BMI)≥26 had higher collapse ratio of mXSA-RP,greater neck circumference and smaller mXSA-RP in the Muller's maneuver than those in group with BMI26(P0.05 for all).It was concluded that dynamic 3-D CT imaging could dynamically show the upper airway changes at soft palate level in OSAHS patients.All the OSAHS patients had airway obstruction of various degrees at soft palate level.But no correlation was observed between the airway change at soft palate level and the severity of OSAHS.The patients in group with BMI≥26 were more likely to develop airway obstruction at soft palate level than those with BMI26.展开更多
The focusing tomography is presented to reconstruct 3 dimensional irradiance distribution. A 3 dimensional luminous body could be considered as the combination of many 2 dimensional parallel luminous sections. Focu...The focusing tomography is presented to reconstruct 3 dimensional irradiance distribution. A 3 dimensional luminous body could be considered as the combination of many 2 dimensional parallel luminous sections. Focus on these discrete sections respectively by a single camera, a group of images would be captured to form governing equations of irradiance. After inversion procedure, the irradiance distribution of different sections could be decoded. In this experimentation two lightbulbs are used to simulate two luminous sections. Reasonable results demonstrate that this technique could be a useful method in irradiance reconstruction after further development.展开更多
Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process ...Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process is time-consuming.For 3D reconstruction data,this paper proposed a lightweight 3D noise reduction method for desktop-level Nano-CT called AAD-ResNet(Axial Attention DeNoise ResNet).The network is framed by theU-net structure.The encoder and decoder are incorporated with the proposed 3D axial attention mechanism and residual dense block.Each layer of the residual dense block can directly access the features of the previous layer,which reduces the redundancy of parameters and improves the efficiency of network training.The 3D axial attention mechanism enhances the correlation between 3D information in the training process and captures the long-distance dependence.It can improve the noise reduction effect and avoid the loss of image structure details.Experimental results show that the network can effectively improve the image quality of a 0.1-s exposure scan to a level close to a 3-s exposure,significantly shortening the sample scanning time.展开更多
The development of diagnostic imaging technology, such as multidetector computed tomography(MDCT) and magnetic resonance cholangiopancreatography(MRCP), has made it possible to obtain detailed images of the bile duct....The development of diagnostic imaging technology, such as multidetector computed tomography(MDCT) and magnetic resonance cholangiopancreatography(MRCP), has made it possible to obtain detailed images of the bile duct. Recent reports have indicated that a 3-dimensional(3D) reconstructed imaging system would be useful for understanding the liver anatomy before surgery. We have investigated a novel method that fuses MDCT and MRCP images. This novel system easily made it possible to detect the anatomical relationship between the vessels and bile duct in the portal hepatis. In this report, we describe a very rare case of extrahepatic cholangiocarcinoma associated with an accessory bile duct from the caudate lobe connecting with the intrapancreatic bile duct. We were unable to preoperatively detect this accessory bile duct using MDCT and MRCP. However, prior to the second operation, we were able to clearly visualise the injured accessory bile duct using our novel 3D imaging modality. In thisreport, we suggest that this imaging technique can be considered a novel and useful modality for understanding the anatomy of the portal hepatis, including the hilar bile duct.展开更多
An infant male presented with the rare anatomy consisting of situs solitus,concordant atrioventricular connections to L-looped ventricles,double outlet right ventricle(DORV),and hypoplastic aortic arch.6 months after ...An infant male presented with the rare anatomy consisting of situs solitus,concordant atrioventricular connections to L-looped ventricles,double outlet right ventricle(DORV),and hypoplastic aortic arch.6 months after neonatal aortic arch repair,the morphologic right ventricle function deteriorated,and surgical evaluation was undertaken to determine if either biventricular repair with a systemic morphologic left ventricle or right ventricular exclusion was possible.After initial echocardiography,magnetic resonance imaging(MRI)was used to create detailed axial and 4-dimensional(4D)images and 3-dimensional(3D)printed models.The detailed anatomy of this rare,complex case and its use in pre-surgical planning is presented.展开更多
Single-pixel imaging(SPI)can transform 2D or 3D image data into 1D light signals,which offers promising prospects for image compression and transmission.However,during data communication these light signals in public ...Single-pixel imaging(SPI)can transform 2D or 3D image data into 1D light signals,which offers promising prospects for image compression and transmission.However,during data communication these light signals in public channels will easily draw the attention of eavesdroppers.Here,we introduce an efficient encryption method for SPI data transmission that uses the 3D Arnold transformation to directly disrupt 1D single-pixel light signals and utilizes the elliptic curve encryption algorithm for key transmission.This encryption scheme immediately employs Hadamard patterns to illuminate the scene and then utilizes the 3D Arnold transformation to permutate the 1D light signal of single-pixel detection.Then the transformation parameters serve as the secret key,while the security of key exchange is guaranteed by an elliptic curve-based key exchange mechanism.Compared with existing encryption schemes,both computer simulations and optical experiments have been conducted to demonstrate that the proposed technique not only enhances the security of encryption but also eliminates the need for complicated pattern scrambling rules.Additionally,this approach solves the problem of secure key transmission,thus ensuring the security of information and the quality of the decrypted images.展开更多
To further research on high-parameter plasma,we plan to develop a two-dimensional hard X-ray(HXR)imaging system at the HL-3 tokamak to measure HXRs with energies ranging from 20 to 300 keV.The application of an array-...To further research on high-parameter plasma,we plan to develop a two-dimensional hard X-ray(HXR)imaging system at the HL-3 tokamak to measure HXRs with energies ranging from 20 to 300 keV.The application of an array-structured detector ensures that this system can measure HXR-radiation spectra from the entire plasma cross section.Therefore,it is suitable for the study of fast-electron physics,such as radio-frequency wave current drives,fast electrons driving instabilities,and plasma disruptions in fusion research.In this study,we develop a simulation for calculating fast-electron bremsstrahlung in the HL-3 tokamak based on the Monte Carlo simulation code Geant4,in which the plasma geometry and forward scattering of fast-electron bremsstrahlung are considered.The preliminary calculation results indicate that the HXR energy deposi-tion on the detector is symmetrically distributed,even though the plasma distribution is asymmetric owing to the toroidal effect.These simulation results are helpful in constructing the relationship between the energy deposition on the detector and parameter distribution on the plasma cross section during HL-3 experiments.This is beneficial for the reconstruction of the fast-electron-distribution function and for optimizing the design of the HXR-imaging system.展开更多
Lie group analysis method is applied to the extended(3+1)-dimensional Kadomtsev–Petviashvili–Boussinesq equation and the corresponding similarity reduction equations are obtained with various infinitesimal generator...Lie group analysis method is applied to the extended(3+1)-dimensional Kadomtsev–Petviashvili–Boussinesq equation and the corresponding similarity reduction equations are obtained with various infinitesimal generators.By selecting suitable arbitrary functions in the similarity reduction solutions,we obtain abundant invariant solutions,including the trigonometric solution,the kink-lump interaction solution,the interaction solution between lump wave and triangular periodic wave,the two-kink solution,the lump solution,the interaction between a lump and two-kink and the periodic lump solution in different planes.These exact solutions are also given graphically to show the detailed structures of this high dimensional integrable system.展开更多
Three-dimensional(3D)cell cultures have contributed to a variety of biological research fields by filling the gap between monolayers and animal models.The modern optical sectioning microscopic methods make it possible...Three-dimensional(3D)cell cultures have contributed to a variety of biological research fields by filling the gap between monolayers and animal models.The modern optical sectioning microscopic methods make it possible to probe the complexity of 3D cell cultures but are limited by the inherent opaqueness.While tissue optical clearing methods have emerged as powerful tools for investigating whole-mount tissues in 3D,they often have limitations,such as being too harsh for fragile 3D cell cultures,requiring complex handling protocols,or inducing tissue deformation with shrinkage or expansion.To address this issue,we proposed a modified optical clearing method for 3D cell cultures,called MACS-W,which is simple,highly efficient,and morphology-preserving.In our evaluation of MACS-W,we found that it exhibits excellent clearing capability in just 10 min,with minimal deformation,and helps drug evaluation on tumor spheroids.In summary,MACS-W is a fast,minimally-deformative and fluorescence compatible clearing method that has the potential to be widely used in the studies of 3D cell cultures.展开更多
BACKGROUND Magnetic resonance imaging(MRI)combined with serum endothelin and galactagoglobin-3(Gal-3)can improve the clinical diagnosis of diabetes mellitus complicated with cerebral infarction.AIM To analyze the clin...BACKGROUND Magnetic resonance imaging(MRI)combined with serum endothelin and galactagoglobin-3(Gal-3)can improve the clinical diagnosis of diabetes mellitus complicated with cerebral infarction.AIM To analyze the clinical value of MRI combined with serum endolipin and Gal-3 for the diagnosis of cerebral infarction in the elderly with diabetes mellitus.METHODS One hundred and fifty patients with acute cerebral infarction hospitalized between January 2021 and December 2023 were divided into two groups according to comorbid diabetes mellitus,including 62 and 88 cases in the diabetic and nondiabetic cerebral infarction groups.Serum samples were collected to detect the expression of serum endolipoxins,and Gal-3,and cranial MRI was performed at admission.Differences between the two groups were compared to analyze the diagnostic value of these parameters.RESULTS Serum endolipin and Gal-3 expression were higher in the diabetic cerebral infarction group(P<0.05).The arterial wall area,vessel area,normalized wall index,and lumen stenosis rate were higher in the diabetic cerebral infarction group,while the rate of arterial lumen moderate and severe stenosis was 48.39% higher(36.36%,P<0.05).The percentage of large(29.03%)and multiple infarcts(33.87%)in the diabetic cerebral infarction group was higher(13.64% and 20.45%),and the incidence rate of lacunar infarcts was lower(37.10%vs 65.91%)(P<0.05).The total incidence of arterial plaque in patients in the diabetic cerebral infarction group was 96.77% higher(69.32%),while the incidence of necrotic lipid core plaque was 58.06%higher(26.14%)(P<0.05).Receiver operating characteristic curve analysis was performed to assess the diagnosis utility of these techniques.MRI in combination with serum endoglin and Gal-3 had the highest area under the curve,the Yoden index,sensitivity and specificity(P<0.05).CONCLUSION The expression of serum endolipin and Gal-3 in elderly patients with diabetes mellitus with cerebral infarction showed an elevated trend,and the degree of luminal stenosis was severe.MRI predominantly revealed large and multiple infarct foci.This combined index examination can improve the clinical diagnosis of diabetes mellitus combined with cerebral infarction.展开更多
BACKGROUND Non-invasive methods to diagnose non-alcoholic steatohepatitis(NASH),an inflammatory subtype of non-alcoholic fatty liver disease(NAFLD),are currently unavailable.AIM To develop an integrin αvβ3-targeted ...BACKGROUND Non-invasive methods to diagnose non-alcoholic steatohepatitis(NASH),an inflammatory subtype of non-alcoholic fatty liver disease(NAFLD),are currently unavailable.AIM To develop an integrin αvβ3-targeted molecular imaging modality to differentiate NASH.METHODS Integrinαvβ3 expression was assessed in Human LO2 hepatocytes Scultured with palmitic and oleic acids(FFA).Hepatic integrinαvβ3 expression was analyzed in rabbits fed a high-fat diet(HFD)and in rats fed a high-fat,high-carbohydrate diet(HFCD).After synthesis,cyclic arginine-glycine-aspartic acid peptide(cRGD)was labeled with gadolinium(Gd)and used as a contrast agent in magnetic resonance imaging(MRI)performed on mice fed with HFCD.RESULTS Integrin αvβ3 was markedly expressed on FFA-cultured hepatocytes,unlike the control hepatocytes.Hepatic integrin αvβ3 expression significantly increased in both HFD-fed rabbits and HFCD-fed rats as simple fatty liver(FL)progressed to steatohepatitis.The distribution of integrinαvβ3 in the liver of NASH cases largely overlapped with albumin-positive staining areas.In comparison to mice with simple FL,the relative liver MRI-T1 signal value at 60 minutes post-injection of Gd-labeled cRGD was significantly increased in mice with steatohepatitis(P<0.05),showing a positive correlation with the NAFLD activity score(r=0.945;P<0.01).Hepatic integrin αvβ3 expression was significantly upregulated during NASH development,with hepatocytes being the primary cells expressing integrin αvβ3.CONCLUSION After using Gd-labeled cRGD as a tracer,NASH was successfully distinguished by visualizing hepatic integrin αvβ3 expression with MRI.展开更多
Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast ...Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast nodules of BI-RADS 3 or above were selected as the research subjects.After pathological diagnosis,24 cases were malignant breast nodules of BI-RADS 3 or above,while 139 cases were benign breast nodules of BI-RADS 3 or above.The diagnosis rate of malignant and benign breast nodules of BI-RADS 3 or above,including 95%CI,was observed and analyzed.Results:The malignant and benign detection rates of conventional ultrasound were 88.63%and 75.00%,respectively,and the malignant and benign detection rates of ultrasound imaging were 93.18%and 87.50%,respectively,with 95%CIs greater than 0.7.Conclusion:Ultrasound imaging can help improve the diagnostic accuracy of benign and malignant breast nodules of BI-RADS 3 and above and reduce the misdiagnosis rate.展开更多
BACKGROUND Early thrombolytic therapy is crucial to treat acute cerebral infarction,especially since the onset of thrombolytic therapy takes 1-6 h.Therefore,early diagnosis and evaluation of cerebral infarction is imp...BACKGROUND Early thrombolytic therapy is crucial to treat acute cerebral infarction,especially since the onset of thrombolytic therapy takes 1-6 h.Therefore,early diagnosis and evaluation of cerebral infarction is important.AIM To investigate the diagnostic value of magnetic resonance multi-delay threedimensional arterial spin labeling(3DASL)and diffusion kurtosis imaging(DKI)in evaluating the perfusion and infarct area size in patients with acute cerebral ischemia.METHODS Eighty-four patients who experienced acute cerebral ischemia from March 2019 to February 2021 were included.All patients in the acute stage underwent magnetic resonance-based examination,and the data were processed by the system’s own software.The apparent diffusion coefficient(ADC),average diffusion coefficient(MD),axial diffusion(AD),radial diffusion(RD),average kurtosis(MK),radial kurtosis(fairly RK),axial kurtosis(AK),and perfusion parameters post-labeling delays(PLD)in the focal area and its corresponding area were compared.The correlation between the lesion area of cerebral infarction under MK and MD and T2-weighted imaging(T2WI)was analyzed.RESULTS The DKI parameters of focal and control areas in the study subjects were compared.The ADC,MD,AD,and RD values in the lesion area were significantly lower than those in the control area.The MK,RK,and AK values in the lesion area were significantly higher than those in the control area.The MK/MD value in the infarct lesions was used to determine the matching situation.MK/MD<5 mm was considered matching and MK/MD≥5 mm was considered mismatching.PLD1.5s and PLD2.5s perfusion parameters in the central,peripheral,and control areas of the infarct lesions in MK/MD-matched and-unmatched patients were not significantly different.PLD1.5s and PLD2.5s perfusion parameter values in the central area of the infarct lesions in MK/MD-matched and-unmatched patients were significantly lower than those in peripheral and control areas.The MK and MD maps showed a lesion area of 20.08±5.74 cm^(2) and 22.09±5.58 cm^(2),respectively.T2WI showed a lesion area of 19.76±5.02 cm^(2).There were no significant differences in the cerebral infarction lesion areas measured using the three methods.MK,MD,and T2WI showed a good correlation.CONCLUSION DKI parameters showed significant difference between the focal and control areas in patients with acute ischemic cerebral infarction.3DASL can effectively determine the changes in perfusion levels in the lesion area.There was a high correlation between the area of the infarct lesions diagnosed by DKI and T2WI.展开更多
The safety accidents caused by collapse column water diversion occur frequently, which has great hidden danger to the safety production of coal mine. Limited by the space of underground, the detection of collapse colu...The safety accidents caused by collapse column water diversion occur frequently, which has great hidden danger to the safety production of coal mine. Limited by the space of underground, the detection of collapse column on the outside of working face has been a difficult problem. Based on this, numerical simulation and imaging research were carried out in this paper. The results indicate that when a seismic source near the roadway is excited, a part of seismic wave propagates along the roadway direction, namely direct P-wave, direct S-wave and direct Love channel wave.<span style="font-family:;" "=""> </span><span style="font-family:Verdana;">When the body waves and Love channel wave propagating to the outside</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">of working face meet the interface of collapse column, the reflected Love channel wave and reflected body waves are generated.</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">Reflection </span><span style="font-family:Verdana;">body </span><span style="font-family:Verdana;">waves and direct waves are mixed in time domain, which is difficult to identify in seismic records, while reflected Love channel wave whose amplitude is relatively strong. The </span><span style="font-family:Verdana;">reflected </span><span style="font-family:Verdana;">Love channel wave which has a large interval from other wave trains in the time domain is easily recognizable in seismic record,</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">which</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">makes it suitable for advanced detection of collapse column. The signal-to-noise ratio of X component is higher than that of Y component and Z component. According to the seismic records, polarization filtering was carried out to enhance the effective wave, which removed the interference waves, and the signal was migrated to get the position parameters of collapse column interface, which was basically consistent with the model position.</span>展开更多
The airborne cross-track three apertures MilliMeter Wave (MMW) Synthetic Aperture Radar (SAR) side-looking three-Dimensional (3D) imaging is investigated in this paper. Three apertures are distributed along the cross-...The airborne cross-track three apertures MilliMeter Wave (MMW) Synthetic Aperture Radar (SAR) side-looking three-Dimensional (3D) imaging is investigated in this paper. Three apertures are distributed along the cross-track direction, and three virtual phase centers will be obtained through one-input and three-output. These three virtual phase centers form a sparse array which can be used to obtain the cross-track resolution. Because the cross-track array is short, the cross-track resolution is low. When the system works in side-looking mode, the cross-track resolution and height resolution will be coupling, and the low cross-track resolution will partly be transformed into the height uncertainty. The beam pattern of the real aperture is used as a weight to improve the Peak to SideLobe Ratio (PSLR) and Integrated SideLobe Ratio (ISLR) of the cross-track sparse array. In order to suppress the high cross-track sidelobes, a weighting preprocessing method is proposed. The 3D images of a point target and a simulation scene are achieved to verify the feasibility of the proposed method. And the imaging result of the real data obtained by the cross-track three-baseline MMW InSAR prototype is presented as a beneficial attempt.展开更多
An approach based on interferometry technique is proposed for three-dimensional (3D) bistatic inverse synthetic aperture radar (ISAR) imaging. It is converted to a monostatic problem by using the theory that a bis...An approach based on interferometry technique is proposed for three-dimensional (3D) bistatic inverse synthetic aperture radar (ISAR) imaging. It is converted to a monostatic problem by using the theory that a bistatic radar equals a monostatic radar located on the bisector of bistatic an- gle. Then, interferometric phases extracted from a pair of cross shaped antennas are used to esti- mate the height and associated rotational velocity. Finally, numerical simulations are provided to e- valuate this method.展开更多
The research work has been seldom done about cloverleaf junction expression in a 3-dimensional city model (3DCM). The main reason is that the cloverleaf junction is often in a complex and enormous construction. Its ma...The research work has been seldom done about cloverleaf junction expression in a 3-dimensional city model (3DCM). The main reason is that the cloverleaf junction is often in a complex and enormous construction. Its main body is bestraddle in air,and has aerial intersections between its parts. This complex feature made cloverleaf junction quite different from buildings and terrain, therefore, it is difficult to express this kind of spatial objects in the same way as for buildings and terrain. In this paper,authors analyze spatial characteristics of cloverleaf junction, propose an all-constraint points TIN algorithm to partition cloverleaf junction road surface, and develop a method to visualize cloverleaf junction road surface using TIN. In order to manage cloverleaf junction data efficiently, the authors also analyzed the mechanism of 3DCM data management, extended BLOB type in relational database, and combined R-tree index to manage 3D spatial data. Based on this extension, an appropriate data展开更多
Using elementary integral method, a complete classification of all possible exact traveling wave solutions to (3+1)-dimensional Nizhnok-Novikov-Veselov equation is given. Some solutions are new.
Wet chemistry methods,including hot-injection and precipitation methods,have emerged as major synthetic routes for high-quality perovskite nanocrystals in backlit display and scintillation applications.However,low che...Wet chemistry methods,including hot-injection and precipitation methods,have emerged as major synthetic routes for high-quality perovskite nanocrystals in backlit display and scintillation applications.However,low chemical yield hinders their upscale production for practical use.Meanwhile,the labile nature of halide-based perovskite poses a major challenge for long-term storage of perovskite nanocrystals.Herein,we report a green synthesis at room temperature for gram-scale production of CsPbBr3 nanosheets with minimum use of solvent,saving over 95% of the solvent for the unity mass nanocrystal production.The perovskite colloid exhibits record stability upon long-term storage for up to 8 months,preserving a photoluminescence quantum yield of 63% in solid state.Importantly,the colloidal nanosheets show self-assembly behavior upon slow solidification,generating a crack-free thin film in a large area.The uniform film was then demonstrated as an efficient scintillation screen for X-ray imaging.Our findings bring a scalable tool for synthesis of high-quality perovskite nanocrystals,which may inspire the industrial optoelectronic application of large-area perovskite film.展开更多
Using the modified find some new exact solutions to Lie point symmetry groups and also get conservation laws, of the CK's direct method, we build the relationship between new solutions and old ones and the (3+1)-d...Using the modified find some new exact solutions to Lie point symmetry groups and also get conservation laws, of the CK's direct method, we build the relationship between new solutions and old ones and the (3+1)-dimensional potentiaial-YTSF equation. Baaed on the invariant group theory, Lie symmetries of the (3+1)-dimensional potential-YTSF equation are obtained. We equation with the given Lie symmetry.展开更多
文摘This study examined the dynamic characteristics of upper airway collapse at soft palate level in patients with obstructive sleep apnea/hypopnea syndrome(OSAHS) by using dynamic 3-Dimensional(3-D) CT imaging.A total of 41 male patients who presented with 2 of the following symptoms,i.e.,daytime sleepiness and fatigue,frequent snoring,and apnea with witness,were diagnosed as having OSAHS.They underwent full-night polysomnography and then dynamic 3-D CT imaging of the upper airway during quiet breathing and in Muller's maneuver.The soft palate length(SPL),the minimal cross-sectional area of the retropalatal region(mXSA-RP),and the vertical distance from the hard palate to the upper posterior part of the hyoid(hhL) were compared between the two breathing states.These parameters,together with hard palate length(HPL),were also compared between mild/moderate and severe OSAHS groups.Association of these parameters with the severity of OSAHS [as reflected by apnea hypopnea index(AHI) and the lowest saturation of blood oxygen(LSaO2)] was examined.The results showed that 31 patients had severe OSAHS,and 10 mild/moderate OSAHS.All the patients had airway obstruction at soft palate level.mXSA-RP was significantly decreased and SPL remarkably increased during Muller's maneuver as compared with the quiet breathing state.There were no significant differences in these airway parameters(except the position of the hyoid bone) between severe and mild/moderate OSAHS groups.And no significant correlation between these airway parameters and the severity of OSAHS was found.The position of hyoid was lower in the severe OSAHS group than in the mild/moderate OSAHS group.The patients in group with body mass index(BMI)≥26 had higher collapse ratio of mXSA-RP,greater neck circumference and smaller mXSA-RP in the Muller's maneuver than those in group with BMI26(P0.05 for all).It was concluded that dynamic 3-D CT imaging could dynamically show the upper airway changes at soft palate level in OSAHS patients.All the OSAHS patients had airway obstruction of various degrees at soft palate level.But no correlation was observed between the airway change at soft palate level and the severity of OSAHS.The patients in group with BMI≥26 were more likely to develop airway obstruction at soft palate level than those with BMI26.
文摘The focusing tomography is presented to reconstruct 3 dimensional irradiance distribution. A 3 dimensional luminous body could be considered as the combination of many 2 dimensional parallel luminous sections. Focus on these discrete sections respectively by a single camera, a group of images would be captured to form governing equations of irradiance. After inversion procedure, the irradiance distribution of different sections could be decoded. In this experimentation two lightbulbs are used to simulate two luminous sections. Reasonable results demonstrate that this technique could be a useful method in irradiance reconstruction after further development.
基金supported by the National Natural Science Foundation of China(62201618).
文摘Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process is time-consuming.For 3D reconstruction data,this paper proposed a lightweight 3D noise reduction method for desktop-level Nano-CT called AAD-ResNet(Axial Attention DeNoise ResNet).The network is framed by theU-net structure.The encoder and decoder are incorporated with the proposed 3D axial attention mechanism and residual dense block.Each layer of the residual dense block can directly access the features of the previous layer,which reduces the redundancy of parameters and improves the efficiency of network training.The 3D axial attention mechanism enhances the correlation between 3D information in the training process and captures the long-distance dependence.It can improve the noise reduction effect and avoid the loss of image structure details.Experimental results show that the network can effectively improve the image quality of a 0.1-s exposure scan to a level close to a 3-s exposure,significantly shortening the sample scanning time.
文摘The development of diagnostic imaging technology, such as multidetector computed tomography(MDCT) and magnetic resonance cholangiopancreatography(MRCP), has made it possible to obtain detailed images of the bile duct. Recent reports have indicated that a 3-dimensional(3D) reconstructed imaging system would be useful for understanding the liver anatomy before surgery. We have investigated a novel method that fuses MDCT and MRCP images. This novel system easily made it possible to detect the anatomical relationship between the vessels and bile duct in the portal hepatis. In this report, we describe a very rare case of extrahepatic cholangiocarcinoma associated with an accessory bile duct from the caudate lobe connecting with the intrapancreatic bile duct. We were unable to preoperatively detect this accessory bile duct using MDCT and MRCP. However, prior to the second operation, we were able to clearly visualise the injured accessory bile duct using our novel 3D imaging modality. In thisreport, we suggest that this imaging technique can be considered a novel and useful modality for understanding the anatomy of the portal hepatis, including the hilar bile duct.
文摘An infant male presented with the rare anatomy consisting of situs solitus,concordant atrioventricular connections to L-looped ventricles,double outlet right ventricle(DORV),and hypoplastic aortic arch.6 months after neonatal aortic arch repair,the morphologic right ventricle function deteriorated,and surgical evaluation was undertaken to determine if either biventricular repair with a systemic morphologic left ventricle or right ventricular exclusion was possible.After initial echocardiography,magnetic resonance imaging(MRI)was used to create detailed axial and 4-dimensional(4D)images and 3-dimensional(3D)printed models.The detailed anatomy of this rare,complex case and its use in pre-surgical planning is presented.
基金Project supported by the National Natural Science Foundation of China(Grant No.62075241).
文摘Single-pixel imaging(SPI)can transform 2D or 3D image data into 1D light signals,which offers promising prospects for image compression and transmission.However,during data communication these light signals in public channels will easily draw the attention of eavesdroppers.Here,we introduce an efficient encryption method for SPI data transmission that uses the 3D Arnold transformation to directly disrupt 1D single-pixel light signals and utilizes the elliptic curve encryption algorithm for key transmission.This encryption scheme immediately employs Hadamard patterns to illuminate the scene and then utilizes the 3D Arnold transformation to permutate the 1D light signal of single-pixel detection.Then the transformation parameters serve as the secret key,while the security of key exchange is guaranteed by an elliptic curve-based key exchange mechanism.Compared with existing encryption schemes,both computer simulations and optical experiments have been conducted to demonstrate that the proposed technique not only enhances the security of encryption but also eliminates the need for complicated pattern scrambling rules.Additionally,this approach solves the problem of secure key transmission,thus ensuring the security of information and the quality of the decrypted images.
基金supported by the National Natural Science Foundation of China(No.12305239)Scientific Research Foundation of Chongqing University of Technology(No.2023ZDZ053)National Key R&D Program of China(No.2019YFE03010001).
文摘To further research on high-parameter plasma,we plan to develop a two-dimensional hard X-ray(HXR)imaging system at the HL-3 tokamak to measure HXRs with energies ranging from 20 to 300 keV.The application of an array-structured detector ensures that this system can measure HXR-radiation spectra from the entire plasma cross section.Therefore,it is suitable for the study of fast-electron physics,such as radio-frequency wave current drives,fast electrons driving instabilities,and plasma disruptions in fusion research.In this study,we develop a simulation for calculating fast-electron bremsstrahlung in the HL-3 tokamak based on the Monte Carlo simulation code Geant4,in which the plasma geometry and forward scattering of fast-electron bremsstrahlung are considered.The preliminary calculation results indicate that the HXR energy deposi-tion on the detector is symmetrically distributed,even though the plasma distribution is asymmetric owing to the toroidal effect.These simulation results are helpful in constructing the relationship between the energy deposition on the detector and parameter distribution on the plasma cross section during HL-3 experiments.This is beneficial for the reconstruction of the fast-electron-distribution function and for optimizing the design of the HXR-imaging system.
文摘Lie group analysis method is applied to the extended(3+1)-dimensional Kadomtsev–Petviashvili–Boussinesq equation and the corresponding similarity reduction equations are obtained with various infinitesimal generators.By selecting suitable arbitrary functions in the similarity reduction solutions,we obtain abundant invariant solutions,including the trigonometric solution,the kink-lump interaction solution,the interaction solution between lump wave and triangular periodic wave,the two-kink solution,the lump solution,the interaction between a lump and two-kink and the periodic lump solution in different planes.These exact solutions are also given graphically to show the detailed structures of this high dimensional integrable system.
基金support from the National Key Research and Development Program of China(Grant No.2017YFA0700501),and the Innovation Fund of WNLO.
文摘Three-dimensional(3D)cell cultures have contributed to a variety of biological research fields by filling the gap between monolayers and animal models.The modern optical sectioning microscopic methods make it possible to probe the complexity of 3D cell cultures but are limited by the inherent opaqueness.While tissue optical clearing methods have emerged as powerful tools for investigating whole-mount tissues in 3D,they often have limitations,such as being too harsh for fragile 3D cell cultures,requiring complex handling protocols,or inducing tissue deformation with shrinkage or expansion.To address this issue,we proposed a modified optical clearing method for 3D cell cultures,called MACS-W,which is simple,highly efficient,and morphology-preserving.In our evaluation of MACS-W,we found that it exhibits excellent clearing capability in just 10 min,with minimal deformation,and helps drug evaluation on tumor spheroids.In summary,MACS-W is a fast,minimally-deformative and fluorescence compatible clearing method that has the potential to be widely used in the studies of 3D cell cultures.
文摘BACKGROUND Magnetic resonance imaging(MRI)combined with serum endothelin and galactagoglobin-3(Gal-3)can improve the clinical diagnosis of diabetes mellitus complicated with cerebral infarction.AIM To analyze the clinical value of MRI combined with serum endolipin and Gal-3 for the diagnosis of cerebral infarction in the elderly with diabetes mellitus.METHODS One hundred and fifty patients with acute cerebral infarction hospitalized between January 2021 and December 2023 were divided into two groups according to comorbid diabetes mellitus,including 62 and 88 cases in the diabetic and nondiabetic cerebral infarction groups.Serum samples were collected to detect the expression of serum endolipoxins,and Gal-3,and cranial MRI was performed at admission.Differences between the two groups were compared to analyze the diagnostic value of these parameters.RESULTS Serum endolipin and Gal-3 expression were higher in the diabetic cerebral infarction group(P<0.05).The arterial wall area,vessel area,normalized wall index,and lumen stenosis rate were higher in the diabetic cerebral infarction group,while the rate of arterial lumen moderate and severe stenosis was 48.39% higher(36.36%,P<0.05).The percentage of large(29.03%)and multiple infarcts(33.87%)in the diabetic cerebral infarction group was higher(13.64% and 20.45%),and the incidence rate of lacunar infarcts was lower(37.10%vs 65.91%)(P<0.05).The total incidence of arterial plaque in patients in the diabetic cerebral infarction group was 96.77% higher(69.32%),while the incidence of necrotic lipid core plaque was 58.06%higher(26.14%)(P<0.05).Receiver operating characteristic curve analysis was performed to assess the diagnosis utility of these techniques.MRI in combination with serum endoglin and Gal-3 had the highest area under the curve,the Yoden index,sensitivity and specificity(P<0.05).CONCLUSION The expression of serum endolipin and Gal-3 in elderly patients with diabetes mellitus with cerebral infarction showed an elevated trend,and the degree of luminal stenosis was severe.MRI predominantly revealed large and multiple infarct foci.This combined index examination can improve the clinical diagnosis of diabetes mellitus combined with cerebral infarction.
基金Supported by the National Natural Science Foundation of China,No.81670513and Young Scientists Fund of the National Natural Science Foundation of China,No.81900511。
文摘BACKGROUND Non-invasive methods to diagnose non-alcoholic steatohepatitis(NASH),an inflammatory subtype of non-alcoholic fatty liver disease(NAFLD),are currently unavailable.AIM To develop an integrin αvβ3-targeted molecular imaging modality to differentiate NASH.METHODS Integrinαvβ3 expression was assessed in Human LO2 hepatocytes Scultured with palmitic and oleic acids(FFA).Hepatic integrinαvβ3 expression was analyzed in rabbits fed a high-fat diet(HFD)and in rats fed a high-fat,high-carbohydrate diet(HFCD).After synthesis,cyclic arginine-glycine-aspartic acid peptide(cRGD)was labeled with gadolinium(Gd)and used as a contrast agent in magnetic resonance imaging(MRI)performed on mice fed with HFCD.RESULTS Integrin αvβ3 was markedly expressed on FFA-cultured hepatocytes,unlike the control hepatocytes.Hepatic integrin αvβ3 expression significantly increased in both HFD-fed rabbits and HFCD-fed rats as simple fatty liver(FL)progressed to steatohepatitis.The distribution of integrinαvβ3 in the liver of NASH cases largely overlapped with albumin-positive staining areas.In comparison to mice with simple FL,the relative liver MRI-T1 signal value at 60 minutes post-injection of Gd-labeled cRGD was significantly increased in mice with steatohepatitis(P<0.05),showing a positive correlation with the NAFLD activity score(r=0.945;P<0.01).Hepatic integrin αvβ3 expression was significantly upregulated during NASH development,with hepatocytes being the primary cells expressing integrin αvβ3.CONCLUSION After using Gd-labeled cRGD as a tracer,NASH was successfully distinguished by visualizing hepatic integrin αvβ3 expression with MRI.
文摘Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast nodules of BI-RADS 3 or above were selected as the research subjects.After pathological diagnosis,24 cases were malignant breast nodules of BI-RADS 3 or above,while 139 cases were benign breast nodules of BI-RADS 3 or above.The diagnosis rate of malignant and benign breast nodules of BI-RADS 3 or above,including 95%CI,was observed and analyzed.Results:The malignant and benign detection rates of conventional ultrasound were 88.63%and 75.00%,respectively,and the malignant and benign detection rates of ultrasound imaging were 93.18%and 87.50%,respectively,with 95%CIs greater than 0.7.Conclusion:Ultrasound imaging can help improve the diagnostic accuracy of benign and malignant breast nodules of BI-RADS 3 and above and reduce the misdiagnosis rate.
文摘BACKGROUND Early thrombolytic therapy is crucial to treat acute cerebral infarction,especially since the onset of thrombolytic therapy takes 1-6 h.Therefore,early diagnosis and evaluation of cerebral infarction is important.AIM To investigate the diagnostic value of magnetic resonance multi-delay threedimensional arterial spin labeling(3DASL)and diffusion kurtosis imaging(DKI)in evaluating the perfusion and infarct area size in patients with acute cerebral ischemia.METHODS Eighty-four patients who experienced acute cerebral ischemia from March 2019 to February 2021 were included.All patients in the acute stage underwent magnetic resonance-based examination,and the data were processed by the system’s own software.The apparent diffusion coefficient(ADC),average diffusion coefficient(MD),axial diffusion(AD),radial diffusion(RD),average kurtosis(MK),radial kurtosis(fairly RK),axial kurtosis(AK),and perfusion parameters post-labeling delays(PLD)in the focal area and its corresponding area were compared.The correlation between the lesion area of cerebral infarction under MK and MD and T2-weighted imaging(T2WI)was analyzed.RESULTS The DKI parameters of focal and control areas in the study subjects were compared.The ADC,MD,AD,and RD values in the lesion area were significantly lower than those in the control area.The MK,RK,and AK values in the lesion area were significantly higher than those in the control area.The MK/MD value in the infarct lesions was used to determine the matching situation.MK/MD<5 mm was considered matching and MK/MD≥5 mm was considered mismatching.PLD1.5s and PLD2.5s perfusion parameters in the central,peripheral,and control areas of the infarct lesions in MK/MD-matched and-unmatched patients were not significantly different.PLD1.5s and PLD2.5s perfusion parameter values in the central area of the infarct lesions in MK/MD-matched and-unmatched patients were significantly lower than those in peripheral and control areas.The MK and MD maps showed a lesion area of 20.08±5.74 cm^(2) and 22.09±5.58 cm^(2),respectively.T2WI showed a lesion area of 19.76±5.02 cm^(2).There were no significant differences in the cerebral infarction lesion areas measured using the three methods.MK,MD,and T2WI showed a good correlation.CONCLUSION DKI parameters showed significant difference between the focal and control areas in patients with acute ischemic cerebral infarction.3DASL can effectively determine the changes in perfusion levels in the lesion area.There was a high correlation between the area of the infarct lesions diagnosed by DKI and T2WI.
文摘The safety accidents caused by collapse column water diversion occur frequently, which has great hidden danger to the safety production of coal mine. Limited by the space of underground, the detection of collapse column on the outside of working face has been a difficult problem. Based on this, numerical simulation and imaging research were carried out in this paper. The results indicate that when a seismic source near the roadway is excited, a part of seismic wave propagates along the roadway direction, namely direct P-wave, direct S-wave and direct Love channel wave.<span style="font-family:;" "=""> </span><span style="font-family:Verdana;">When the body waves and Love channel wave propagating to the outside</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">of working face meet the interface of collapse column, the reflected Love channel wave and reflected body waves are generated.</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">Reflection </span><span style="font-family:Verdana;">body </span><span style="font-family:Verdana;">waves and direct waves are mixed in time domain, which is difficult to identify in seismic records, while reflected Love channel wave whose amplitude is relatively strong. The </span><span style="font-family:Verdana;">reflected </span><span style="font-family:Verdana;">Love channel wave which has a large interval from other wave trains in the time domain is easily recognizable in seismic record,</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">which</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">makes it suitable for advanced detection of collapse column. The signal-to-noise ratio of X component is higher than that of Y component and Z component. According to the seismic records, polarization filtering was carried out to enhance the effective wave, which removed the interference waves, and the signal was migrated to get the position parameters of collapse column interface, which was basically consistent with the model position.</span>
基金Supported by the National Basic Research Program (973) of China (No. 2009CB72400)
文摘The airborne cross-track three apertures MilliMeter Wave (MMW) Synthetic Aperture Radar (SAR) side-looking three-Dimensional (3D) imaging is investigated in this paper. Three apertures are distributed along the cross-track direction, and three virtual phase centers will be obtained through one-input and three-output. These three virtual phase centers form a sparse array which can be used to obtain the cross-track resolution. Because the cross-track array is short, the cross-track resolution is low. When the system works in side-looking mode, the cross-track resolution and height resolution will be coupling, and the low cross-track resolution will partly be transformed into the height uncertainty. The beam pattern of the real aperture is used as a weight to improve the Peak to SideLobe Ratio (PSLR) and Integrated SideLobe Ratio (ISLR) of the cross-track sparse array. In order to suppress the high cross-track sidelobes, a weighting preprocessing method is proposed. The 3D images of a point target and a simulation scene are achieved to verify the feasibility of the proposed method. And the imaging result of the real data obtained by the cross-track three-baseline MMW InSAR prototype is presented as a beneficial attempt.
文摘An approach based on interferometry technique is proposed for three-dimensional (3D) bistatic inverse synthetic aperture radar (ISAR) imaging. It is converted to a monostatic problem by using the theory that a bistatic radar equals a monostatic radar located on the bisector of bistatic an- gle. Then, interferometric phases extracted from a pair of cross shaped antennas are used to esti- mate the height and associated rotational velocity. Finally, numerical simulations are provided to e- valuate this method.
文摘The research work has been seldom done about cloverleaf junction expression in a 3-dimensional city model (3DCM). The main reason is that the cloverleaf junction is often in a complex and enormous construction. Its main body is bestraddle in air,and has aerial intersections between its parts. This complex feature made cloverleaf junction quite different from buildings and terrain, therefore, it is difficult to express this kind of spatial objects in the same way as for buildings and terrain. In this paper,authors analyze spatial characteristics of cloverleaf junction, propose an all-constraint points TIN algorithm to partition cloverleaf junction road surface, and develop a method to visualize cloverleaf junction road surface using TIN. In order to manage cloverleaf junction data efficiently, the authors also analyzed the mechanism of 3DCM data management, extended BLOB type in relational database, and combined R-tree index to manage 3D spatial data. Based on this extension, an appropriate data
基金The project supported by Scientific Research Fund of Heilongjiang Province of China under Grant No. 11511008The author would like to thank referees for their valuable suggestions.
文摘Using elementary integral method, a complete classification of all possible exact traveling wave solutions to (3+1)-dimensional Nizhnok-Novikov-Veselov equation is given. Some solutions are new.
基金supported by National Natural Science Foundation of China (Nos. 21805111 and 11405073)Taishan Scholar Fund
文摘Wet chemistry methods,including hot-injection and precipitation methods,have emerged as major synthetic routes for high-quality perovskite nanocrystals in backlit display and scintillation applications.However,low chemical yield hinders their upscale production for practical use.Meanwhile,the labile nature of halide-based perovskite poses a major challenge for long-term storage of perovskite nanocrystals.Herein,we report a green synthesis at room temperature for gram-scale production of CsPbBr3 nanosheets with minimum use of solvent,saving over 95% of the solvent for the unity mass nanocrystal production.The perovskite colloid exhibits record stability upon long-term storage for up to 8 months,preserving a photoluminescence quantum yield of 63% in solid state.Importantly,the colloidal nanosheets show self-assembly behavior upon slow solidification,generating a crack-free thin film in a large area.The uniform film was then demonstrated as an efficient scintillation screen for X-ray imaging.Our findings bring a scalable tool for synthesis of high-quality perovskite nanocrystals,which may inspire the industrial optoelectronic application of large-area perovskite film.
基金The project supported by the Natural Science Foundation of Shandong Province of China under Grant No. 2004zx16 tCorresponding author, E-maih zzlh100@163.com
文摘Using the modified find some new exact solutions to Lie point symmetry groups and also get conservation laws, of the CK's direct method, we build the relationship between new solutions and old ones and the (3+1)-dimensional potentiaial-YTSF equation. Baaed on the invariant group theory, Lie symmetries of the (3+1)-dimensional potential-YTSF equation are obtained. We equation with the given Lie symmetry.