The effect of Co complexes with a Schiff base ligand on the electrochemical corrosion behavior of 316 L SS in 0.1 M H<sub>2</sub>SO<sub>4</sub> at 25℃ has been investigated at various inhibito...The effect of Co complexes with a Schiff base ligand on the electrochemical corrosion behavior of 316 L SS in 0.1 M H<sub>2</sub>SO<sub>4</sub> at 25℃ has been investigated at various inhibitor concentration using electrochemical techniques (impedance spectroscopy (EIS), polarization curves). Corrosion measurements indicate that Co complex act as moderately inhibitors. Results revealed that increasing the concentration of Co complex increases the corresponding IE% values till 100 ppm. Co complex acts as mixed type inhibitors with predominant effect on the anodic dissolution of iron. Adsorption studies showed that the process follows Langmuir adsorption isotherm.展开更多
Hot-formed components are constantly exposed to hostile environments with corrosive substances. Microstructural changes caused by thermomechanical processing can be predicted to increase the corrosion resistance of au...Hot-formed components are constantly exposed to hostile environments with corrosive substances. Microstructural changes caused by thermomechanical processing can be predicted to increase the corrosion resistance of austenitic stainless steels. The objective of this study is to understand the relationship between the dynamic softening mechanisms and corrosion resistance, thus optimizing the hot-forming process. In the current work, the dynamic recrystallization (DRX) behavior of AISI 316 L austenitic stainless steel was studied in the temperature range of 1273 - 1423 K and strain-rate range of 0.1 - 5.0 s-1 using physical simulation. Subsequently, potentiodynamic polarization tests and scanning electron microscopy were performed on the hot-deformed samples to investigate the influence of temperature and strain-rate on the corrosion resistance and mechanical properties. The results indicated that the DRX fractions increased under low-temperature and high strain-rate conditions, resulting in grain refinement. The potentiodynamic polarization tests indicated that the dynamically recovered samples demonstrated high resistance to corrosion compared with the DRX samples. The best route found for the investigated alloy was for the strain to be applied at a temperature of 1423 K and a strain rate of 0.1 s-1.展开更多
Selective Laser Melting (SLM) shows a big potential among metal additive manufacturing (AM) technologies. However, the large thermal gradients and the local melting and solidification processes of SLM result in the pr...Selective Laser Melting (SLM) shows a big potential among metal additive manufacturing (AM) technologies. However, the large thermal gradients and the local melting and solidification processes of SLM result in the presence of a significant amount of residual stresses in the as built parts. These internal stresses will not only affect mechanical properties, but also increase the risk of Stress Corrosion Cracking (SCC). A twister used in an air extraction pump of a condenser to create a swirl in the water, was chosen as a candidate component to be produced by SLM in 316 L stainless steel. Since the main expected damage mechanism of this component in service is corrosion, corrosion tests were carried out on an as-built twister as well as on heat treated components. It was shown that a low temperature heat treatment at 450℃ had only a limited effect on the residual stress reduction and concomitant corrosion properties, while the internal stresses were significantly reduced when a high temperature heat treatment at 950℃ was applied. Furthermore, a specific stress corrosion sensitivity test proved to be a useful tool to evaluate the internal stress distribution in a specific component.展开更多
文摘The effect of Co complexes with a Schiff base ligand on the electrochemical corrosion behavior of 316 L SS in 0.1 M H<sub>2</sub>SO<sub>4</sub> at 25℃ has been investigated at various inhibitor concentration using electrochemical techniques (impedance spectroscopy (EIS), polarization curves). Corrosion measurements indicate that Co complex act as moderately inhibitors. Results revealed that increasing the concentration of Co complex increases the corresponding IE% values till 100 ppm. Co complex acts as mixed type inhibitors with predominant effect on the anodic dissolution of iron. Adsorption studies showed that the process follows Langmuir adsorption isotherm.
文摘Hot-formed components are constantly exposed to hostile environments with corrosive substances. Microstructural changes caused by thermomechanical processing can be predicted to increase the corrosion resistance of austenitic stainless steels. The objective of this study is to understand the relationship between the dynamic softening mechanisms and corrosion resistance, thus optimizing the hot-forming process. In the current work, the dynamic recrystallization (DRX) behavior of AISI 316 L austenitic stainless steel was studied in the temperature range of 1273 - 1423 K and strain-rate range of 0.1 - 5.0 s-1 using physical simulation. Subsequently, potentiodynamic polarization tests and scanning electron microscopy were performed on the hot-deformed samples to investigate the influence of temperature and strain-rate on the corrosion resistance and mechanical properties. The results indicated that the DRX fractions increased under low-temperature and high strain-rate conditions, resulting in grain refinement. The potentiodynamic polarization tests indicated that the dynamically recovered samples demonstrated high resistance to corrosion compared with the DRX samples. The best route found for the investigated alloy was for the strain to be applied at a temperature of 1423 K and a strain rate of 0.1 s-1.
文摘Selective Laser Melting (SLM) shows a big potential among metal additive manufacturing (AM) technologies. However, the large thermal gradients and the local melting and solidification processes of SLM result in the presence of a significant amount of residual stresses in the as built parts. These internal stresses will not only affect mechanical properties, but also increase the risk of Stress Corrosion Cracking (SCC). A twister used in an air extraction pump of a condenser to create a swirl in the water, was chosen as a candidate component to be produced by SLM in 316 L stainless steel. Since the main expected damage mechanism of this component in service is corrosion, corrosion tests were carried out on an as-built twister as well as on heat treated components. It was shown that a low temperature heat treatment at 450℃ had only a limited effect on the residual stress reduction and concomitant corrosion properties, while the internal stresses were significantly reduced when a high temperature heat treatment at 950℃ was applied. Furthermore, a specific stress corrosion sensitivity test proved to be a useful tool to evaluate the internal stress distribution in a specific component.