期刊文献+
共找到1,036篇文章
< 1 2 52 >
每页显示 20 50 100
SAR regional all-azimuth observation orbit design for target 3D reconstruction
1
作者 WANG Yanan ZHOU Chaowei +1 位作者 LIU Aifang MAO Qin 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期609-618,共10页
Three-dimensional(3D) synthetic aperture radar(SAR)extends the conventional 2D images into 3D features by several acquisitions in different aspects. Compared with 3D techniques via multiple observations in elevation, ... Three-dimensional(3D) synthetic aperture radar(SAR)extends the conventional 2D images into 3D features by several acquisitions in different aspects. Compared with 3D techniques via multiple observations in elevation, e.g. SAR interferometry(InSAR) and SAR tomography(TomoSAR), holographic SAR can retrieve 3D structure by observations in azimuth. This paper focuses on designing a novel type of orbit to achieve SAR regional all-azimuth observation(AAO) for embedded targets detection and holographic 3D reconstruction. The ground tracks of the AAO orbit separate the earth surface into grids. Target in these grids can be accessed with an azimuth angle span of360°, which is similar to the flight path of airborne circular SAR(CSAR). Inspired from the successive coverage orbits of optical sensors, several optimizations are made in the proposed method to ensure favorable grazing angles, the performance of 3D reconstruction, and long-term supervision for SAR sensors. Simulation experiments show the regional AAO can be completed within five hours. In addition, a second AAO of the same area can be duplicated in two days. Finally, an airborne SAR data process result is presented to illustrate the significance of AAO in 3D reconstruction. 展开更多
关键词 synthetic aperture radar(SAR) orbit design all-azimuth observation(AAO) three-dimensional(3D)reconstruction successive coverage
下载PDF
3D-CT指导单孔分体脊柱内镜精准切除钩状突减压颈神经的安全性研究
2
作者 刘昌震 王红艳 +4 位作者 孙兆忠 孙宁 冯志萌 李洒 李岳飞 《中国疼痛医学杂志》 CAS CSCD 北大核心 2024年第7期515-521,共7页
目的:观测钩状突尖端(uncinate process tip,UPT)、椎弓根峡部和颈神经之间的位置关系,为单孔分体脊柱内镜辅助颈椎前路椎间盘切除减压融合术中钩状突精准切除实现颈神经彻底减压提供临床数据参考。方法:选取2016年8月至2021年1月滨州... 目的:观测钩状突尖端(uncinate process tip,UPT)、椎弓根峡部和颈神经之间的位置关系,为单孔分体脊柱内镜辅助颈椎前路椎间盘切除减压融合术中钩状突精准切除实现颈神经彻底减压提供临床数据参考。方法:选取2016年8月至2021年1月滨州医学院附属医院的26例神经根型颈椎病病人资料,并在Mimics21.0上观测C3~4至C7~T1相关参数:UPT分别至UPT所在矢状面的颈神经前缘前后距离(a)、UPT所在矢状面的颈神经下缘垂直距离(b)、颈神经起点上缘左右距离(c)、颈神经起点上缘垂直距离(d)、颈神经起点下缘垂直距离(e)、椎弓根峡部外侧缘前后距离(f)、椎弓根峡部外侧缘左右距离(g)、颈神经外展角(∠A)、前倾角(∠B)。结果:C_(3~4)至C_(7)~T_(1),同节段不同性别、不同侧别之间差异无统计学意义;同节段b、e之间差异无统计学意义,表明减压UPT所在矢状面的颈神经下缘即可实现颈神经起点下缘减压;随着C_(3~4)至C_(7)~T_(1)节段降低,a逐渐减小;b、d、e、g、∠A、∠B逐渐增加;c、f先增加后减小(P<0.05)。结论:以UPT作为重要骨性标志点,明确颈神经减压范围并精准切除钩状突。UPT向前(0.9±0.5)mm至(2.3±1.3)mm至椎弓根峡部外侧缘,向外磨透钩状突,可完成UPT至椎弓根区出口处颈神经腹侧减压;向上(5.5±2.1)mm至(8.0±3.0)mm、向内(1.1±0.5)mm至(1.9±0.9)mm分别磨除部分上位椎体和钩状突后外侧壁增生骨赘,可显露硬脊膜外侧缘和颈神经起点上缘,完成UPT至颈神经起点减压,为手术精准切除钩状突安全减压颈神经提供理论依据。 展开更多
关键词 3d-ct 单孔分体脊柱内镜 颈椎前路椎间盘切除减压融合术 钩状突尖端
下载PDF
前列腺动脉CTA与C臂3D-CT血管成像技术在前列腺动脉栓塞术中的应用价值比较
3
作者 林宇佳 曾国斌 +5 位作者 廖政贤 廖立安 张国栋 张文 吴兴华 韩淑辉 《医药前沿》 2024年第5期14-18,共5页
目的:比较前列腺动脉(PA)的计算机体层血管成像(CTA)检查与C臂三维重建计算机断层扫描(3DCT)血管成像技术在前列腺动脉栓塞术(PAE)中的应用价值。方法:收集2020年1月—2022年6月在梅州市人民医院介入手术室行超选择性PAE的39例患者(前... 目的:比较前列腺动脉(PA)的计算机体层血管成像(CTA)检查与C臂三维重建计算机断层扫描(3DCT)血管成像技术在前列腺动脉栓塞术(PAE)中的应用价值。方法:收集2020年1月—2022年6月在梅州市人民医院介入手术室行超选择性PAE的39例患者(前列腺增生17例,前列腺癌22例)的术前PA的CTA检查及术中C臂3D-CT血管成像的影像资料,分为CTA组及3D-CT组。分别对CTA、3D-CT检查出的PA起源、数目及走行判定的准确性进行分析,以超选至PA的DSA造影为标准,评估两种前列腺动脉成像技术对PAE的指导价值。结果:在39例患者的78侧髂内动脉中共超选95支PA并经DSA造影证实,其中CTA共诊断出75支PA,诊出率为78.9%,3D-CT共诊断出92支PA,诊出率为96.8%,两组比较,差异有统计学意义(χ^(2)=21.56,P<0.05)。其中3侧髂内动脉共3支CTA诊断为PA,而3D-CT排除为PA。5侧髂内动脉共5支PA CTA未能显示,而3D-CT可显示;9侧髂内动脉共11支PA:CTA仅能诊断出其起源于髂内动脉,而3D-CT可明确其具体起源位置。CTA对大于0.625 mm的PA可以清楚显示其走行与周围血管的关系,而3D-CT可以显示小于0.625 mm的PA的走行情况并显示前列腺组织的染色及有无周围组织器官的染色情况。结论:C臂3D-CT相比于前列腺动脉CTA在PAE术中能更清楚地显示PA的起源、数目及其走行关系,能更好地指导PAE,而术前CTA作为无创检查亦能为术者提供PA及其周围血管的解剖,为术前PAE评估提供了影像依据。 展开更多
关键词 前列腺动脉栓塞术 前列腺癌 前列腺增生 CTA C臂3d-ct
下载PDF
Parallel computing approach for efficient 3-D X-ray-simulated image reconstruction 被引量:1
4
作者 Ou-Yi Li Yang Wang +1 位作者 Qiong Zhang Yong-Hui Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第7期122-136,共15页
Accurate 3-dimensional(3-D)reconstruction technology for nondestructive testing based on digital radiography(DR)is of great importance for alleviating the drawbacks of the existing computed tomography(CT)-based method... Accurate 3-dimensional(3-D)reconstruction technology for nondestructive testing based on digital radiography(DR)is of great importance for alleviating the drawbacks of the existing computed tomography(CT)-based method.The commonly used Monte Carlo simulation method ensures well-performing imaging results for DR.However,for 3-D reconstruction,it is limited by its high time consumption.To solve this problem,this study proposes a parallel computing method to accelerate Monte Carlo simulation for projection images with a parallel interface and a specific DR application.The images are utilized for 3-D reconstruction of the test model.We verify the accuracy of parallel computing for DR and evaluate the performance of two parallel computing modes-multithreaded applications(G4-MT)and message-passing interfaces(G4-MPI)-by assessing parallel speedup and efficiency.This study explores the scalability of the hybrid G4-MPI and G4-MT modes.The results show that the two parallel computing modes can significantly reduce the Monte Carlo simulation time because the parallel speedup increment of Monte Carlo simulations can be considered linear growth,and the parallel efficiency is maintained at a high level.The hybrid mode has strong scalability,as the overall run time of the 180 simulations using 320 threads is 15.35 h with 10 billion particles emitted,and the parallel speedup can be up to 151.36.The 3-D reconstruction of the model is achieved based on the filtered back projection(FBP)algorithm using 180 projection images obtained with the hybrid G4-MPI and G4-MT.The quality of the reconstructed sliced images is satisfactory because the images can reflect the internal structure of the test model.This method is applied to a complex model,and the quality of the reconstructed images is evaluated. 展开更多
关键词 Parallel computing Monte Carlo Digital radiography 3-D reconstruction
下载PDF
Rapid printing of 3D porous scaffolds for breast reconstruction 被引量:1
5
作者 Pengcheng Zhao Biling Wang +5 位作者 Lu Wang Zexin Fu Jun Hu Yande Liu Ji Wang Yong He 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2023年第6期691-703,共13页
Prosthesis implantation and fat transplantation are common breast reconstructionmethods.In general,prosthesis implantation alone does not achieve a realistic enough appearance,and fat transplantation alone is difficul... Prosthesis implantation and fat transplantation are common breast reconstructionmethods.In general,prosthesis implantation alone does not achieve a realistic enough appearance,and fat transplantation alone is difficult to achieve in the correct capacity.To date,no reports have focused on methods of combining fat with implanted prostheses for breast reconstruction.Using a newly designed bionic ink(i.e.,polyether F127 diacrylate(F127DA)&poly(ethylene glycol)diacrylate(PEGDA))and projection-based three-dimensional bioprinting(PBP),we report the development of a new method for printing porous prostheses.PEGDA was used to improve the printing precision of the prosthesis by increasing the gel point of F127DA and reducing the impact of external temperature.The compression modulus of the printed prosthesis was very close to that of prostheses currently used in clinical practice and to that of natural breasts.Finally,stromal vascular fraction gel(SVF-gel),a human fat extract,was injected into the pores of the synthesized prostheses to prepare a prosthesis mixed with adipose tissue.These were implanted subcutaneously in nude mice to observe their biological performance.After 14 and 28 days of observation,the prosthesis showed good biocompatibility,and adipose tissues grew well in and around the prosthesis.This result shows that a porous prosthesis containing pre-placed adipose tissues is a promising breast reconstruction material. 展开更多
关键词 Projection-based 3D bioprinting(PBP) F127DA Breast reconstruction Fat transplantation
下载PDF
Improvement of Binocular Reconstruction Algorithm for Measuring 3D Pavement Texture Using a Single Laser Line Scanning Constraint 被引量:1
6
作者 Yuanyuan Wang RuiWang +1 位作者 Xiaofeng Ren Junan Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1951-1972,共22页
The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was... The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was improved threefold.First,a single moving laser line was introduced to carry out global scanning constraints on the target,which would well overcome the difficulty of installing and recognizing excessive laser lines.Second,four kinds of improved algorithms,namely,disparity replacement,superposition synthesis,subregion segmentation,and subregion segmentation centroid enhancement,were established based on different constraint mechanism.Last,the improved binocular reconstruction test device was developed to realize the dual functions of 3D texture measurement and precision self-evaluation.Results show that compared with traditional algorithms,the introduction of a single laser line scanning constraint is helpful in improving the measurement’s accuracy.Among various improved algorithms,the improvement effect of the subregion segmentation centroid enhancement method is the best.It has a good effect on both overall measurement and single pointmeasurement,which can be considered to be used in pavement function evaluation. 展开更多
关键词 3D pavement texture binocular reconstruction algorithm single laser line scanning constraint improved stereo matching
下载PDF
Preoperative 3D reconstruction and fluorescent indocyanine green for laparoscopic duodenum preserving pancreatic head resection:A case report 被引量:1
7
作者 Xiao-Li Li Lian-Sheng Gong 《World Journal of Clinical Cases》 SCIE 2023年第4期903-908,共6页
BACKGROUND Duodenum-preserving pancreatic head resection(DPPHR)is the choice of surgery for benign or low-grade malignant tumors of the pancreatic head.Laparoscopic DPPHR(LDPPHR)procedure can be improved by preoperati... BACKGROUND Duodenum-preserving pancreatic head resection(DPPHR)is the choice of surgery for benign or low-grade malignant tumors of the pancreatic head.Laparoscopic DPPHR(LDPPHR)procedure can be improved by preoperative 3D model reconstruction and the use of intravenous indocyanine green fluorescent before surgery for real-time navigation with fluorescent display to guide the surgical dissection and prevention of from injury to vessels and biliary tract.CASE SUMMARY Here we report the successful short-and long-term outcomes after one year following LDPPHR for a 60-year lady who had an uneventful recovery and was discharged home one week after the surgery.CONCLUSION There was no bile leakage or pancreatic leakage or delayed gastric emptying.The histopathology report showed multiple cysts in the pancreatic head and localized pancreatic intraepithelial tumor lesions.The resected margin was free of tumor. 展开更多
关键词 Duodenum-preserving pancreatic head resection Fluorescent navigation Laparoscopic 3D model reconstruction Case report
下载PDF
Accurate resection of hilar cholangiocarcinoma using eOrganmap 3D reconstruction and full quantization technique 被引量:1
8
作者 Da-Peng Cui Shuang Fan +3 位作者 Ying-Xue Guo Qian-Wei Zhao Yue-Xin Qiao Jian-Dong Fei 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第8期1693-1702,共10页
BACKGROUND For treatment of hilar cholangiocarcinoma(HCCA),the rate of radical resection is low and prognosis is poor,and preoperative evaluation is not sufficiently accurate.3D visualization has the advantage of givi... BACKGROUND For treatment of hilar cholangiocarcinoma(HCCA),the rate of radical resection is low and prognosis is poor,and preoperative evaluation is not sufficiently accurate.3D visualization has the advantage of giving a stereoscopic view,which makes accurate resection of HCCA possible.AIM To establish precise resection of HCCA based on eOrganmap 3D reconstruction and full quantification technology.METHODS We retrospectively analyzed the clinical data of 73 patients who underwent HCCA surgery.All patients were assigned to two groups.The traditional group received traditional 2D imaging planning before surgery(n=35).The eOrganmap group underwent 3D reconstruction and full quantitative technical planning before surgery(n=38).The preoperative evaluation,anatomical classification of hilar hepatic vessels,indicators associated with surgery,postoperative complications,liver function,and stress response indexes were compared between the groups.RESULTS Compared with the traditional group,the amount of intraoperative blood loss in the eOrganmap group was lower,the operating time and postoperative intestinal ventilation time were shorter,and R0 resection rate and lymph node dissection number were higher(P<0.05).The total complication rate in the eOrganmap group was 21.05%compared with 25.71%in the traditional group(P>0.05).The levels of total bilirubin,Albumin(ALB),aspartate transaminase,and alanine transaminase in the eOrganmap group were significantly different from those in the traditional group(intergroup effect:F=450.400,79.120,95.730,and 13.240,respectively;all P<0.001).Total bilirubin,aspartate transaminase,and alanine transaminase in both groups showed a decreasing trend with time(time effect:F=30.270,17.340,and 13.380,respectively;all P<0.001).There was an interaction between patient group and time(interaction effect:F=3.072,2.965,and 2.703,respectively;P=0.0282,0.032,and 0.046,respectively);ALB levels in both groups tended to increase with time(time effect:F=22.490,P<0.001),and there was an interaction effect between groups and time(interaction effect:F=4.607,P=0.004).In the eOrganmap group,there was a high correlation between the actual volume of intraoperative liver specimen resection and the volume of preoperative virtual liver resection(t=0.916,P<0.001).CONCLUSION The establishment of accurate laparoscopic resection of hilar cholangiocarcinoma based on preoperative eOrganmap 3D reconstruction and full quantization technology can make laparoscopic resection of hilar cholangiocarcinoma more accurate and safe. 展开更多
关键词 eOrganmap 3D reconstruction Full quantification technology Laparoscopic surgery Hilar cholangiocarcinoma Precise resection
下载PDF
3D Face Reconstruction from a Single Image Using a Combined PCA-LPP Method
9
作者 Jee-Sic Hur Hyeong-Geun Lee +2 位作者 Shinjin Kang Yeo Chan Yoon Soo Kyun Kim 《Computers, Materials & Continua》 SCIE EI 2023年第3期6213-6227,共15页
In this paper, we proposed a combined PCA-LPP algorithm toimprove 3D face reconstruction performance. Principal component analysis(PCA) is commonly used to compress images and extract features. Onedisadvantage of PCA ... In this paper, we proposed a combined PCA-LPP algorithm toimprove 3D face reconstruction performance. Principal component analysis(PCA) is commonly used to compress images and extract features. Onedisadvantage of PCA is local feature loss. To address this, various studies haveproposed combining a PCA-LPP-based algorithm with a locality preservingprojection (LPP). However, the existing PCA-LPP method is unsuitable for3D face reconstruction because it focuses on data classification and clustering.In the existing PCA-LPP, the adjacency graph, which primarily shows the connectionrelationships between data, is composed of the e-or k-nearest neighbortechniques. By contrast, in this study, complex and detailed parts, such aswrinkles around the eyes and mouth, can be reconstructed by composing thetopology of the 3D face model as an adjacency graph and extracting localfeatures from the connection relationship between the 3D model vertices.Experiments verified the effectiveness of the proposed method. When theproposed method was applied to the 3D face reconstruction evaluation set,a performance improvement of 10% to 20% was observed compared with theexisting PCA-based method. 展开更多
关键词 Principal component analysis locality preserving project 3DMM face reconstruction face modeling
下载PDF
Fast Estimation of Loader’s Shovel Load Volume by 3D Reconstruction of Material Piles
10
作者 Binyun Wu Shaojie Wang +2 位作者 Haojing Lin Shijiang Li Liang Hou 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第5期187-205,共19页
Fast and accurate measurement of the volume of earthmoving materials is of great signifcance for the real-time evaluation of loader operation efciency and the realization of autonomous operation. Existing methods for ... Fast and accurate measurement of the volume of earthmoving materials is of great signifcance for the real-time evaluation of loader operation efciency and the realization of autonomous operation. Existing methods for volume measurement, such as total station-based methods, cannot measure the volume in real time, while the bucket-based method also has the disadvantage of poor universality. In this study, a fast estimation method for a loader’s shovel load volume by 3D reconstruction of material piles is proposed. First, a dense stereo matching method (QORB–MAPM) was proposed by integrating the improved quadtree ORB algorithm (QORB) and the maximum a posteriori probability model (MAPM), which achieves fast matching of feature points and dense 3D reconstruction of material piles. Second, the 3D point cloud model of the material piles before and after shoveling was registered and segmented to obtain the 3D point cloud model of the shoveling area, and the Alpha-shape algorithm of Delaunay triangulation was used to estimate the volume of the 3D point cloud model. Finally, a shovel loading volume measurement experiment was conducted under loose-soil working conditions. The results show that the shovel loading volume estimation method (QORB–MAPM VE) proposed in this study has higher estimation accuracy and less calculation time in volume estimation and bucket fll factor estimation, and it has signifcant theoretical research and engineering application value. 展开更多
关键词 LOADER Volume estimation Binocular stereo vision 3D terrain reconstruction Point cloud registration and segmentation
下载PDF
Unveiling the parasitic-reaction-driven surface reconstruction in Ni-rich cathode and the electrochemical role of Li_(2)CO_(3)
11
作者 Jiyu Cai Zhenzhen Yang +18 位作者 Xinwei Zhou Bingning Wang Ana Suzana Jianming Bai Chen Liao Yuzi Liu Yanbin Chen Shunlin Song Xuequan Zhang Li Wang Xiangming He Xiangbo Meng Niloofar Karami Baasit Ali Shaik Sulaiman Natasha A.Chernova Shailesh Upreti Brad Prevel Feng Wang Zonghai Chen 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第10期126-136,I0006,共12页
Nickel-rich transition-metal oxides are widely regarded as promising cathode materials for high-energydensity lithium-ion batteries for emerging electric vehicles. However, achieving high energy density in Ni-rich cat... Nickel-rich transition-metal oxides are widely regarded as promising cathode materials for high-energydensity lithium-ion batteries for emerging electric vehicles. However, achieving high energy density in Ni-rich cathodes is accompanied by substantial safety and cycle-life obstacles. The major issues of Ni-rich cathodes at high working potentials are originated from the unstable cathode-electrolyte interface, while the underlying mechanism of parasitic reactions towards surface reconstructions of cathode materials is not well understood. In this work, we controlled the Li_(2)CO_(3) impurity content on LiNi_(0.83)Mn_(0.1)Co_(0.07)O_(2) cathodes using air, tank-air, and O_(2) synthesis environments. Home-built high-precision leakage current and on-line electrochemical mass spectroscopy experiments verify that Li_(2)CO_(3) impurity is a significant promoter of parasitic reactions on Ni-rich cathodes. The rate of parasitic reactions is strongly correlated to Li_(2)CO_(3) content and severe performance deterioration of Ni83 cathodes.The post-mortem characterizations via high-resolution transition electron microscope and X-ray photoelectron spectroscopy depth profiles reveal that parasitic reactions promote more Ni reduction and O deficiency and even rock-salt phase transformation at the surface of cathode materials. Our observation suggests that surface reconstructions have a strong affiliation to parasitic reactions that create chemically acidic environment to etch away the lattice oxygen and offer the electrical charge to reduce the valence state of transition metal. Thus, this study advances our understanding on surface reconstructions of Nirich cathodes and prepares us for searching for rational strategies. 展开更多
关键词 Ni-rich cathodes Surface reconstructions Phase transformation Parasitic reactions Li_(2)CO_(3)
下载PDF
3D printing of personalized polylactic acid scaffold laden with GelMA/autologous auricle cartilage to promote ear reconstruction
12
作者 Xingyu Gui Zhiyu Peng +13 位作者 Ping Song Li Chen Xiujuan Xu Hairui Li Pei Tang Yixi Wang Zixuan Su Qingquan Kong Zhenyu Zhang Zhengyong Li Ying Cen Changchun Zhou Yujiang Fan Xingdong Zhang 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2023年第4期451-463,共13页
At present,the clinical reconstruction of the auricle usually adopts the strategy of taking autologous costal cartilage.This method has great trauma to patients,poor plasticity and inaccurate shaping.Three-dimensional... At present,the clinical reconstruction of the auricle usually adopts the strategy of taking autologous costal cartilage.This method has great trauma to patients,poor plasticity and inaccurate shaping.Three-dimensional(3D)printing technology has made a great breakthrough in the clinical application of orthopedic implants.This study explored the combination of 3D printing and tissue engineering to precisely reconstruct the auricle.First,a polylactic acid(PLA)polymer scaffold with a precisely customized patient appearance was fabricated,and then auricle cartilage fragments were loaded into the 3D-printed porous PLA scaffold to promote auricle reconstruction.In vitro,gelatin methacrylamide(GelMA)hydrogels loaded with different sizes of rabbit ear cartilage fragments were studied to assess the regenerative activity of various autologous cartilage fragments.In vivo,rat ear cartilage fragments were placed in an accurately designed porous PLA polymer ear scaffold to promote auricle reconstruction.The results indicated that the chondrocytes in the cartilage fragments could maintain the morphological phenotype in vitro.After three months of implantation observation,it was conducive to promoting the subsequent regeneration of cartilage in vivo.The autologous cartilage fragments combined with 3D printing technology show promising potential in auricle reconstruction. 展开更多
关键词 MICROTIA 3D printing Polylactic acid(PLA)polymer scaffolds Gelatin methacrylamide Cartilage reconstruction
下载PDF
3D Echocardiogram Reconstruction Employing a Flip Directional Texture Pyramid
13
作者 C.Preethi M.Mohamed Sathik S.Shajun Nisha 《Computer Systems Science & Engineering》 SCIE EI 2023年第6期2971-2988,共18页
Three dimensional(3D)echocardiogram enables cardiologists to visua-lize suspicious cardiac structures in detail.In recent years,this three-dimensional echocardiogram carries important clinical value in virtual surgica... Three dimensional(3D)echocardiogram enables cardiologists to visua-lize suspicious cardiac structures in detail.In recent years,this three-dimensional echocardiogram carries important clinical value in virtual surgical simulation.However,this 3D echocardiogram involves a trade-off difficulty between accu-racy and efficient computation in clinical diagnosis.This paper presents a novel Flip Directional 3D Volume Reconstruction(FD-3DVR)method for the recon-struction of echocardiogram images.The proposed method consists of two main steps:multiplanar volumetric imaging and 3D volume reconstruction.In the crea-tion of multiplanar volumetric imaging,two-dimensional(2D)image pixels are mapped into voxels of the volumetric grid.As the obtained slices are discontin-uous,there are some missing voxels in the volume data.To restore the structural and textural information of 3D ultrasound volume,the proposed method creates a volume pyramid in parallel with theflip directional texture pyramid.Initially,the nearest neighbors of missing voxels in the multiplanar volumetric imaging are identified by 3D ANN(Approximate Nearest Neighbor)patch matching method.Furthermore,aflip directional texture pyramid is proposed and aggregated with distance in patch matching tofind out the most similar neighbors.In the recon-struction step,structural and textural information obtained from differentflip angle directions can reconstruct 3D volume well with the desired accuracy.Com-pared with existing 3D reconstruction methods,the proposed Flip Directional 3D Volume Reconstruction(FD-3DVR)method provides superior performance for the mean peak signal-to-noise ratio(40.538 for the proposed method I and 39.626 for the proposed method II).Experimental results performed on the cardi-ac datasets demonstrate the efficiency of the proposed method for the reconstruc-tion of echocardiogram images. 展开更多
关键词 Three-dimensional echocardiogram 3D ANN patch matching volume pyramid flip directional texture pyramid 3D volume reconstruction
下载PDF
胃近端切除伴双通道重建手术ICD-9-CM-3编码探讨
14
作者 郭旭升 杨智彬 张璇 《中国医院统计》 2024年第2期153-155,160,共4页
双通道重建理论上是近端胃切除术较为理想的消化道重建方式,由于ICD-9-CM-3词典库更新停滞以及医院端现用手术词典库扩码不足等原因,对于胃近端切除伴双通道重建手术的ICD编码存在一定争议。本文从相关手术的内涵和历史演进等角度,对该... 双通道重建理论上是近端胃切除术较为理想的消化道重建方式,由于ICD-9-CM-3词典库更新停滞以及医院端现用手术词典库扩码不足等原因,对于胃近端切除伴双通道重建手术的ICD编码存在一定争议。本文从相关手术的内涵和历史演进等角度,对该手术的ICD-9-CM-3编码进行了分析探讨。 展开更多
关键词 胃近端切除手术 双通道重建手术 ICD-9-CM-3 手术操作编码
下载PDF
Fast Mesh Reconstruction from Single View Based on GCN and Topology Modification 被引量:1
15
作者 Xiaorui Zhang Feng Xu +2 位作者 Wei Sun Yan Jiang Yi Cao 《Computer Systems Science & Engineering》 SCIE EI 2023年第5期1695-1709,共15页
3D reconstruction based on single view aims to reconstruct the entire 3D shape of an object from one perspective.When existing methods reconstruct the mesh surface of complex objects,the surface details are difficult ... 3D reconstruction based on single view aims to reconstruct the entire 3D shape of an object from one perspective.When existing methods reconstruct the mesh surface of complex objects,the surface details are difficult to predict and the reconstruction visual effect is poor because the mesh representation is not easily integrated into the deep learning framework;the 3D topology is easily limited by predefined templates and inflexible,and unnecessary mesh self-intersections and connections will be generated when reconstructing complex topology,thus destroying the surface details;the training of the reconstruction network is limited by the large amount of information attached to the mesh vertices,and the training time of the reconstructed network is too long.In this paper,we propose a method for fast mesh reconstruction from single view based on Graph Convolutional Network(GCN)and topology modification.We use GCN to ensure the generation of high-quality mesh surfaces and use topology modification to improve the flexibility of the topology.Meanwhile,a feature fusion method is proposed to make full use of the features of each stage of the image hierarchically.We use 3D open dataset ShapeNet to train our network and add a new weight parameter to speed up the training process.Extensive experiments demonstrate that our method can not only reconstruct object meshes on complex topological surfaces,but also has better qualitative and quantitative results. 展开更多
关键词 3D surface reconstruction deep learning GCN topology modification end-to-end framework
下载PDF
Reconstruction and recovery of anatase TiO_(2) from spent selective catalytic reduction catalyst by Na OH hydrothermal method 被引量:1
16
作者 Jinlong Liu Chenye Wang +4 位作者 Xingrui Wang Chen Zhao Huiquan Li Ganyu Zhu Jianbo Zhang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第8期53-60,共8页
The improper disposal of spent selective catalytic reduction (SCR) catalysts causes environmental pollution and metal resource waste.A novel process to recover anatase titanium dioxide (TiO_(2)) from spent SCR catalys... The improper disposal of spent selective catalytic reduction (SCR) catalysts causes environmental pollution and metal resource waste.A novel process to recover anatase titanium dioxide (TiO_(2)) from spent SCR catalysts was proposed.The process included alkali (NaOH) hydrothermal treatment,sulfuric acid washing,and calcination.Anatase TiO_(2) in spent SCR catalyst was reconstructed by forming Na_(2)Ti_(2)O_(4)(OH)_(2) nanosheet during NaOH hydrothermal treatment and H_(2)Ti_(2)O_(4)(OH)_(2) during sulfuric acid washing.Anatase TiO_(2) was recovered by decomposing H_(2)Ti_(2)O_(4)(OH)_(2) during calcination.The surface pore properties of the recovered anatase TiO_(2) were adequately improved,and its specific surface area (SSA) and pore volume (PV) were 85 m^(2)·g^(-1)and 0.40 cm^(3)·g^(-1),respectively.The elements affecting catalytic abilities(arsenic and sodium) were also removed.The SCR catalyst was resynthesized using the recovered TiO_(2) as raw material,and its catalytic performance in NO selective reduction was comparable with that of commercial SCR catalyst.This study realized the sustainable recycling of anatase TiO_(2) from spent SCR catalyst. 展开更多
关键词 TiO_(2)reconstruction Anatase TiO_(2)recovery Pore properties Spent V_(2)O_(5)-WO_(3)/TiO_(2)catalyst
下载PDF
3D reconstruction method and connectivity rules of fracture networks generated under different mining layouts 被引量:18
17
作者 Zhang Ru Ai Ting +2 位作者 Li Hegui Zhang Zetian Liu Jianfeng 《International Journal of Mining Science and Technology》 SCIE EI 2013年第6期863-871,共9页
In current research,a series of triaxial tests,which were employed to simulate three typical mining layouts(i.e.,top-coal caving,non-pillar mining and protected coal seam mining),were conducted on coal by using MTS815... In current research,a series of triaxial tests,which were employed to simulate three typical mining layouts(i.e.,top-coal caving,non-pillar mining and protected coal seam mining),were conducted on coal by using MTS815 Flex Test GT rock mechanics test system,and the fracture networks in the broken coal samples were qualitatively and quantitatively investigated by employing CT scanning and 3D reconstruction techniques.This work aimed at providing a detail description on the micro-structure and fractureconnectivity characteristics of rupture coal samples under different mining layouts.The results show that:(i)for protected coal seam mining layout,the coal specimens failure is in a compression-shear manner and oppositely,(ii)the tension-shear failure phenomenon is observed for top-coal caving and non-pillar mining layouts.By investigating the connectivity features of the generated fractures in the direction ofσ_1,under different mining layouts,it is found that the connectivity level of the fractures of the samples corresponding to non-pillar mining layout was the highest. 展开更多
关键词 Mining layout 3D reconstruction of CT images Fracture network Connectivity level
下载PDF
Using on-site liver 3-D reconstruction and volumetric calculations in split liver transplantation 被引量:3
18
作者 Trevor W Reichman Brittany Fiorello +5 位作者 Ian Carmody Humberto Bohorquez Ari Cohen John Seal David Bruce George E Loss 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2016年第6期587-592,共6页
BACKGROUND: Split liver transplantation increases the number of grafts available for transplantation. Pre-recovery assessment of liver graft volume is essential for selecting suitable recipients. The purpose of this ... BACKGROUND: Split liver transplantation increases the number of grafts available for transplantation. Pre-recovery assessment of liver graft volume is essential for selecting suitable recipients. The purpose of this study was to determine the ability and feasibility of constructing a 3-D model to aid in surgical planning and to predict graft weight prior to an in situ division of the donor liver. METHODS: Over 11 months, 3-D volumetric reconstruction of 4 deceased donors was performed using Pathfinder Scout liver volumetric software. Demographic, laboratory, operative, perioperative and survival data for these patients along with donor demographic data were collected prospectively and analyzed retrospectively. RESULTS: The average predicted weight of the grafts from the adult donors obtained from an in situ split procedure were 1130 g (930-1458 g) for the extended right lobe donors and 312 g (222-396 g) for left lateral segment grafts. Actual adult graft weight was 92% of the predicted weight for both the extended right grafts and the left lateral segment grafts. The predicted and actual graft weights for the pediatric donors were 176 g and 210 g for the left lateral segment grafts and 308 g and 280 g for the extended right lobe grafts,respectively. All grafts were transplanted except for the right lobe from the pediatric donors due to the small graft weight.CONCLUSIONS: On-site volumetric assessment of donors provides useful information for the planning of an in situ split and for selection of recipients. This information may expand the donor pool to recipients previously felt to be unsuitable due to donor and/or recipient weight. 展开更多
关键词 split liver transplantation reduced-size liver transplantation 3-D reconstruction
下载PDF
3D printing of calcium phosphate bioceramic with tailored biodegradation rate for skull bone tissue reconstruction 被引量:7
19
作者 Boqing Zhang Huan Sun +6 位作者 Lina Wu Liang Ma Fei Xing Qingquan Kong Yujiang Fan Changchun Zhou Xingdong Zhang 《Bio-Design and Manufacturing》 SCIE CSCD 2019年第3期161-171,共11页
The bone regenerative scaffold with the tailored degradation rate matching with the growth rate of the new bone is essential for adolescent bone repair.To satisfy these requirement,we proposed bone tissue scaffolds wi... The bone regenerative scaffold with the tailored degradation rate matching with the growth rate of the new bone is essential for adolescent bone repair.To satisfy these requirement,we proposed bone tissue scaffolds with controlled degradation rate using osteoinductive materials(Ca-P bioceramics),which is expected to present a controllable biodegradation rate for patients who need bone regeneration.Physicochemical properties,porosity,compressive strength and degradation properties of the scaffolds were studied.3D printed Ca-P scaffold(3DS),gas foaming Ca-P scaffold(FS)and autogenous bone(AB)were used in vivo for personalized beagle skull defect repair.Histological results indicated that the 3DS was highly vascularized and well combined with surrounding tissues.FS showed obvious newly formed bone tissues.AB showed the best repair effect,but it was found that AB scaffolds were partially absorbed and degraded.This study indicated that the 3D printed Ca-P bioceramics with tailored biodegradation rate is a promising candidate for personalized skull bone tissue reconstruction. 展开更多
关键词 3D printing SKULL repair Calcium PHOSPHATE ceramics TAILORED BIODEGRADATION rate Bone reconstruction
下载PDF
3D reconstruction of worn parts for flexible remanufacture based on robotic arc welding 被引量:4
20
作者 殷子强 张广军 +1 位作者 高洪明 吴林 《China Welding》 EI CAS 2010年第4期54-58,共5页
3D reconstruction of worn parts is the foundation for remanufacturing system based on robotic arc welding, because it can provide 3D geometric information for robot task plan. In this investigation, a novel 3D reconst... 3D reconstruction of worn parts is the foundation for remanufacturing system based on robotic arc welding, because it can provide 3D geometric information for robot task plan. In this investigation, a novel 3D reconstruction system based on linear structured light vision sensing is developed. This system hardware consists of a MTC368-CB CCD camera, a MLH-645 laser projector and a DH-CG300 image grabbing card. This system software is developed to control the image data capture. In order to reconstruct the 3D geometric information from the captured image, a two steps rapid calibration algorithm is proposed. The 3D reconstruction experiment shows a satisfactory result. 展开更多
关键词 3D reconstruction remanufacture structured light robotic are welding
下载PDF
上一页 1 2 52 下一页 到第
使用帮助 返回顶部