期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
某双向灌排泵站的现场测试及改造思路 被引量:7
1
作者 成立 汤方平 +2 位作者 仇宝云 刘超 周济人 《扬州大学学报(自然科学版)》 CAS CSCD 2005年第3期67-69,共3页
采用五孔球形探针现场测流技术对某双向灌排泵站机组进行了流量测试.测试结果表明,该泵型流量系数小,效率低,因此须更新泵型,防止涡带产生,并应设置泵站实时水力参数监控系统.
关键词 泵站改造 现场测流 五孔球形探针
下载PDF
Effects of Probe Support on the Flow Field of a Low-Speed Axial Compressor 被引量:12
2
作者 MA Hongwei LI Shaohui WEI Wei 《Journal of Thermal Science》 SCIE EI CAS CSCD 2014年第2期120-126,共7页
This paper presents an investigation on the effect of probe support on the flow field of an axial compressor.The experiment is carried out in a large-scale low-speed research compressor.A cylindrical probe support int... This paper presents an investigation on the effect of probe support on the flow field of an axial compressor.The experiment is carried out in a large-scale low-speed research compressor.A cylindrical probe support intruding to 50% blade span was installed at 50% chord upstream from the rotor leading edge.The region from 5° to 32° off the probe support in the direction of rotation at the rotor outlet was measured with a 5-hole probe and a high-response total pressure probe.The experiment is performed at both near-design and near-stall points.The measuring results of 5-hole probe and high-response total pressure probe indicate that the probe blockage effect is different at different blade spans.The wake of the probe support weakens the leakage vortex intensity at the tip region,leading to greater total pressure rise.At near-design condition,the presence of probe support has a negative effect on the region from 75% to 92% span,while improves the flow field below 75% span.At near stall condition,the probe support has a negative effect on the region from 70% to 90% span,and almost has no influence on the flow field below 70% span. 展开更多
关键词 probe support COMPRESSOR 5-hole probe high-response total pressure probe tip leakage flow
原文传递
Effects of Airfoil-probe Tubes on the Flow Field of a Compressor Cascade 被引量:5
3
作者 MA Hongwei JIN Chao +1 位作者 ZHAO Lianpeng MA Rong 《Journal of Thermal Science》 SCIE EI CAS CSCD 2017年第4期321-330,共10页
To explore the effects of airfoil-probe tubes and its installment position on the flow field of the compressor cas- cade, and find out the mechanism that how the airfoil-probes affect the aerodynamic characteristics o... To explore the effects of airfoil-probe tubes and its installment position on the flow field of the compressor cas- cade, and find out the mechanism that how the airfoil-probes affect the aerodynamic characteristics of the com- pressor cascade, this paper performed both numerical and experimcntal works on the same compressor cascade. The experiment mainly focused on the cases of low Mach number (Ma = 0.1), and cases with different Mach numbers (0.1, 0.3, 0.7) and different incidence angles (-5, 0, 5) are investigated by the numerical method. The case without the airfoil-probe tube was referenced as the baseline, and other three cases with the airfoil-probe tubes installed in different chordwise positions O0%, 50%, 70% of the chord length) were studied. The diameter of the airfoil-probe tube is 3ram, which is configured as 300% amplification of some particular airfoil-probe ac- cording to the geometrical similarity principle. The results show that the airfoil-probe tubes have a negative in- fluenc~ on the flow capacity of the cascade at all investigation points. The separations and the large scale stream- wise vortices that induced by the airfoil-probe tube on the pressure side cause most the losses at the high Mach number. The influence of the airfoil-probe tube on the flow field in the vicinity of the pressure side surface is lo- cal separation at the low Mach number. The airfoil-probe tubes also have a clearly effect on the leakage flow. It decreases the mass flow of the leakage flow and weakens the intensity of the leakage vortex, but enlarges the in- fluence area. The total pressure loss of the case that the tube is installed at the half chordwise position is generally lower than other cases especially at the high Mach number, it can even decrease the losses compared with the ba- sic case. 展开更多
关键词 airfoil-probe compressor cascade installment position 5-hole probe
原文传递
Effects of Suction Side Squealer Tip on the Performance of a Low-Speed Axial Compressor 被引量:6
4
作者 Jun Zhang Hongwei Ma Jingyang Li 《Journal of Thermal Science》 SCIE EI CAS CSCD 2012年第3期223-229,共7页
This paper presents the investigation of the effects of suction side squealer tip on the performance of an axial compressor. The experiment is carded out in a single-stage large-scale low-speed compressor. The investi... This paper presents the investigation of the effects of suction side squealer tip on the performance of an axial compressor. The experiment is carded out in a single-stage large-scale low-speed compressor. The investigated tip geometries include fiat tip as the baseline and suction side squealer tip. The tip clearance of the baseline is 0.5% of the blade span. The static pressure rise characteristic curves of both the rotor and the stage are measured. The flow field at the exit of the rotor is measured by a 5-hole probe under design and off-design conditions. The static pressure on the endwall of the rotor passage is also obtained. The results show that the pressure rise characteristic curves obtained by measuring the pressure on the end wall are almost unchanged by using the suction side squealer tip. The measuring results of the 5-hole probe show the static pressure and the total pressure in tip region is slightly greater than that of the flat tip at the design condition at the exit of the rotor. It also leads to greater averaged static pressure rise and total pressure. At the near stall condition, the averaged static pressure and total pressure is lower than the baseline which is related to the redistribution of the blade load caused by the suction side squealer tip. 展开更多
关键词 COMPRESSOR squealer tip 5-hole probe off-design condition tip leakage flow.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部