Influence of applied potentials and loading waveform on the fatigue crack growth for steel A537 in 3.5% NaCl solution,and corresponding straining electrode behaviour have been studied.Under the applied potentials over...Influence of applied potentials and loading waveform on the fatigue crack growth for steel A537 in 3.5% NaCl solution,and corresponding straining electrode behaviour have been studied.Under the applied potentials over or below -800mV(SCE),the anodic dissolution or the hydrogen embrittlement is predominatant,respectively.For applied anodic potential,the acceleration effect of continuous loading pattern on the CF crack growth mainly appeared at the range of low ΔK values,while for cathodic potential,it appeared at the high ΔK values.The continuous straining causes a decrease of natural potential and an increase of anodic dissolution current.展开更多
From the corrosion fatigue test under intermit- tent wetting condition for offshore structural steel of A537 cl.l and data analysis,some results associ- ated with the role of pits in fatigue process have been discussed.
Investigation was carried out of the crack growth rate in weld metal and heat affected zone (HAZ)of offshore structural steels,homemade steel 36Z together with foreign steel A537 of similar strength grade by compariso...Investigation was carried out of the crack growth rate in weld metal and heat affected zone (HAZ)of offshore structural steels,homemade steel 36Z together with foreign steel A537 of similar strength grade by comparison,in artificial sea water undergone fatigue with different frequencies.The crack growth rate in weld metal and HAZ of steel 36Z fatigued at low fre- queney may be 3—5 and 4—10 times as high as that at high frequency respectivley.The crack growth rate for steel 36Z may fairly match that of A537,The crack growth model and frac- ture of weld metal in corrosive medium were also discussed.展开更多
文摘Influence of applied potentials and loading waveform on the fatigue crack growth for steel A537 in 3.5% NaCl solution,and corresponding straining electrode behaviour have been studied.Under the applied potentials over or below -800mV(SCE),the anodic dissolution or the hydrogen embrittlement is predominatant,respectively.For applied anodic potential,the acceleration effect of continuous loading pattern on the CF crack growth mainly appeared at the range of low ΔK values,while for cathodic potential,it appeared at the high ΔK values.The continuous straining causes a decrease of natural potential and an increase of anodic dissolution current.
文摘From the corrosion fatigue test under intermit- tent wetting condition for offshore structural steel of A537 cl.l and data analysis,some results associ- ated with the role of pits in fatigue process have been discussed.
文摘Investigation was carried out of the crack growth rate in weld metal and heat affected zone (HAZ)of offshore structural steels,homemade steel 36Z together with foreign steel A537 of similar strength grade by comparison,in artificial sea water undergone fatigue with different frequencies.The crack growth rate in weld metal and HAZ of steel 36Z fatigued at low fre- queney may be 3—5 and 4—10 times as high as that at high frequency respectivley.The crack growth rate for steel 36Z may fairly match that of A537,The crack growth model and frac- ture of weld metal in corrosive medium were also discussed.