China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so...China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so long-distance and bulk power transmission are needed; besides, the geography and climate conditions are serious, rains, fogs, lightning and typhoon as well as high temperature are common all the year round. Facing these challenges, the power grid enhanced stability control, improved the equipment and strengthen the network structure. In the future, the power grid plans to optimize the disposition of power sources and build digitalized power system.展开更多
针对交直流混合微电网中双向AC/DC换流器在外界扰动下出现的直流母线电压波动问题,设计了一种应用于双向AC/DC换流器的非线性扩张状态观测器(nonlinear extended state observer,NLESO),以实现对分布式电源功率波动和负荷投切变化等不...针对交直流混合微电网中双向AC/DC换流器在外界扰动下出现的直流母线电压波动问题,设计了一种应用于双向AC/DC换流器的非线性扩张状态观测器(nonlinear extended state observer,NLESO),以实现对分布式电源功率波动和负荷投切变化等不确定因素的快速追踪与补偿,保证了在不同扰动下交直流混合微电网的稳定性。进一步提出了基于NLESO的改进积分滑模控制方法,提高了直流母线电压的控制精度。结合非线性光滑函数设计了滑模趋近律,消除了传统滑模控制中的高频抖振现象。通过Lyapunov理论对系统的稳定性进行分析验证,仿真结果表明该控制方法响应速度快、控制精度高、抗扰动能力强并且无抖振现象。展开更多
The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/D...The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.展开更多
The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power thr...The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power through overhead lines,HCBs are required to have reclosing capability due to the high fault probability and the fact that most of the faults are temporary faults.To avoid the secondary fault strike and equipment damage that may be caused by the reclosing of the HCB when the permanent fault occurs,an adaptive reclosing scheme based on traveling wave injection is proposed in this paper.The scheme injects traveling wave signal into the fault dc line through the additionally configured auxiliary discharge branch in the HCB,and then uses the reflection characteristic of the traveling wave signal on the dc line to identify temporary and permanent faults,to be able to realize fast reclosing when the temporary fault occurs and reliably avoid reclosing after the permanent fault occurs.The test results in the simulation model of the four-terminal dc grid show that the proposed adaptive reclosing scheme can quickly and reliably identify temporary and permanent faults,greatly shorten the power outage time of temporary faults.In addition,it has the advantages of easiness to implement,high reliability,robustness to high-resistance fault and no dead zone,etc.展开更多
Bidirectional interlinking converter(BIC)is the core equipment in a hybrid AC/DC microgrid connected between AC and DC sub-grids.However,the variety of control modes and flexible bidirectional power flow complicate th...Bidirectional interlinking converter(BIC)is the core equipment in a hybrid AC/DC microgrid connected between AC and DC sub-grids.However,the variety of control modes and flexible bidirectional power flow complicate the influence of AC faults on BIC itself and on DC sub-grid,which potentially threaten both converter safety and system reliability.This study first investigates AC fault influence on the BIC and DC bus voltage under different BIC control modes and different pre-fault operation states,by developing a mathematical model and equivalent sequence network.Second,based on the analysis results,a general accommodative current limiting strategy is proposed for BIC without limitations to specific mode or operation condition.Current amplitude is predicted and constrained according to the critical requirements to protect the BIC and relieving the AC fault influence on the DC bus voltage.Compared with conventional methods,potential current limit failure and distortions under asymmetric faults can also be avoided.Finally,experiments verify feasibility of the proposed method.展开更多
This paper presents performance analysis on hybrid AC/DC microgrid networks for residential home cluster. The design of the proposed microgrid includes comprehensive types of Distributed Generators (DGs) as hybrid pow...This paper presents performance analysis on hybrid AC/DC microgrid networks for residential home cluster. The design of the proposed microgrid includes comprehensive types of Distributed Generators (DGs) as hybrid power sources (wind, Photovoltaic (PV) solar cell, battery, fuel cell). Details about each DG dynamic modeling are presented and discussed. The customers in home cluster can be connected in both of the operating modes: islanded to the microgrid or connected to utility grid. Each DG has appended control system with its modeling that will be discussed to control DG performance. The wind turbine will be controlled by AC control system within three sub-control systems: 1) speed regulator and pitch control, 2) rotor side converter control, and 3) grid side converter control. The AC control structure is based on PLL, current regulator and voltage booster converter with using of photovoltaic Voltage Source Converter (VSC) and inverters to connect to the grid. The DC control system is mainly based on Maximum Power Point Tracking (MPPT) controller and boost converter connected to the PV array block and in order to control the system. The case study is used to analyze the performance of the proposed microgrid. The buses voltages, active power and reactive power responses are presented in both of grid-connected and islanded modes. In addition, the power factor, Total Harmonic Distortion (THD) and modulation index are calculated.展开更多
针对风电和光伏并网发电系统的功率波动问题,研究了一种基于双向DC/AC变换器的混合储能系统的动态控制策略。对含有超级电容器与蓄电池组的混合储能系统,通过双闭环控制器对变换器内部的电压电流进行控制,把波动变化较快的电流分量分配...针对风电和光伏并网发电系统的功率波动问题,研究了一种基于双向DC/AC变换器的混合储能系统的动态控制策略。对含有超级电容器与蓄电池组的混合储能系统,通过双闭环控制器对变换器内部的电压电流进行控制,把波动变化较快的电流分量分配给超级电容器,由蓄电池来响应波动变化较慢的电流分量。同时,控制系统将超级电容器的电压稳定在预设范围内。基于扩展卡尔曼滤波(Extended Kalman Filter,EKF)对蓄电池的荷电状态(State of Charge,SOC)进行控制,使其SOC值稳定在安全范围内并延长了蓄电池的使用寿命。通过仿真实验,验证了控制方法的有效性。展开更多
模块化多电平换流器高压直流输电(modular multilevel converter based high voltage direct current,MMC-HVDC)由于具备自换相能力,尤其适用于向弱交流电网供电。交流系统强度降低时,会制约系统的直流功率传输能力,甚至导致系统失稳。...模块化多电平换流器高压直流输电(modular multilevel converter based high voltage direct current,MMC-HVDC)由于具备自换相能力,尤其适用于向弱交流电网供电。交流系统强度降低时,会制约系统的直流功率传输能力,甚至导致系统失稳。针对联接弱交流电网时MMC-HVDC系统功率传输受限的问题,建立了状态空间与直流阻抗模型,从时域、频域两方面研究了交流系统强度对直流功率传输能力的影响,明确了弱交流电网工况下功率传输受限的原因。基于参与因子定位结果,提出了在定直流电压控制环节引入直流电流反馈的功率传输能力提升方法,从时域、频域两方面对控制策略的提升作用进行了机理分析,并定量得出了控制参数的可行域及功率传输能力的最大提升水平。该方法在避免稳态误差的前提下,有效提升了MMC-HVDC系统的直流功率传输能力。展开更多
文摘China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so long-distance and bulk power transmission are needed; besides, the geography and climate conditions are serious, rains, fogs, lightning and typhoon as well as high temperature are common all the year round. Facing these challenges, the power grid enhanced stability control, improved the equipment and strengthen the network structure. In the future, the power grid plans to optimize the disposition of power sources and build digitalized power system.
文摘针对交直流混合微电网中双向AC/DC换流器在外界扰动下出现的直流母线电压波动问题,设计了一种应用于双向AC/DC换流器的非线性扩张状态观测器(nonlinear extended state observer,NLESO),以实现对分布式电源功率波动和负荷投切变化等不确定因素的快速追踪与补偿,保证了在不同扰动下交直流混合微电网的稳定性。进一步提出了基于NLESO的改进积分滑模控制方法,提高了直流母线电压的控制精度。结合非线性光滑函数设计了滑模趋近律,消除了传统滑模控制中的高频抖振现象。通过Lyapunov理论对系统的稳定性进行分析验证,仿真结果表明该控制方法响应速度快、控制精度高、抗扰动能力强并且无抖振现象。
基金supported by National Key Research and Development Program of China (2016YFB0900500,2017YFB0903100)the State Grid Science and Technology Project (SGRI-DL-F1-51-011)
文摘The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.
基金supported by the Science and Technology Project of State Grid Corporation of China under Grant 520201210025。
文摘The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power through overhead lines,HCBs are required to have reclosing capability due to the high fault probability and the fact that most of the faults are temporary faults.To avoid the secondary fault strike and equipment damage that may be caused by the reclosing of the HCB when the permanent fault occurs,an adaptive reclosing scheme based on traveling wave injection is proposed in this paper.The scheme injects traveling wave signal into the fault dc line through the additionally configured auxiliary discharge branch in the HCB,and then uses the reflection characteristic of the traveling wave signal on the dc line to identify temporary and permanent faults,to be able to realize fast reclosing when the temporary fault occurs and reliably avoid reclosing after the permanent fault occurs.The test results in the simulation model of the four-terminal dc grid show that the proposed adaptive reclosing scheme can quickly and reliably identify temporary and permanent faults,greatly shorten the power outage time of temporary faults.In addition,it has the advantages of easiness to implement,high reliability,robustness to high-resistance fault and no dead zone,etc.
文摘Bidirectional interlinking converter(BIC)is the core equipment in a hybrid AC/DC microgrid connected between AC and DC sub-grids.However,the variety of control modes and flexible bidirectional power flow complicate the influence of AC faults on BIC itself and on DC sub-grid,which potentially threaten both converter safety and system reliability.This study first investigates AC fault influence on the BIC and DC bus voltage under different BIC control modes and different pre-fault operation states,by developing a mathematical model and equivalent sequence network.Second,based on the analysis results,a general accommodative current limiting strategy is proposed for BIC without limitations to specific mode or operation condition.Current amplitude is predicted and constrained according to the critical requirements to protect the BIC and relieving the AC fault influence on the DC bus voltage.Compared with conventional methods,potential current limit failure and distortions under asymmetric faults can also be avoided.Finally,experiments verify feasibility of the proposed method.
文摘This paper presents performance analysis on hybrid AC/DC microgrid networks for residential home cluster. The design of the proposed microgrid includes comprehensive types of Distributed Generators (DGs) as hybrid power sources (wind, Photovoltaic (PV) solar cell, battery, fuel cell). Details about each DG dynamic modeling are presented and discussed. The customers in home cluster can be connected in both of the operating modes: islanded to the microgrid or connected to utility grid. Each DG has appended control system with its modeling that will be discussed to control DG performance. The wind turbine will be controlled by AC control system within three sub-control systems: 1) speed regulator and pitch control, 2) rotor side converter control, and 3) grid side converter control. The AC control structure is based on PLL, current regulator and voltage booster converter with using of photovoltaic Voltage Source Converter (VSC) and inverters to connect to the grid. The DC control system is mainly based on Maximum Power Point Tracking (MPPT) controller and boost converter connected to the PV array block and in order to control the system. The case study is used to analyze the performance of the proposed microgrid. The buses voltages, active power and reactive power responses are presented in both of grid-connected and islanded modes. In addition, the power factor, Total Harmonic Distortion (THD) and modulation index are calculated.
文摘针对风电和光伏并网发电系统的功率波动问题,研究了一种基于双向DC/AC变换器的混合储能系统的动态控制策略。对含有超级电容器与蓄电池组的混合储能系统,通过双闭环控制器对变换器内部的电压电流进行控制,把波动变化较快的电流分量分配给超级电容器,由蓄电池来响应波动变化较慢的电流分量。同时,控制系统将超级电容器的电压稳定在预设范围内。基于扩展卡尔曼滤波(Extended Kalman Filter,EKF)对蓄电池的荷电状态(State of Charge,SOC)进行控制,使其SOC值稳定在安全范围内并延长了蓄电池的使用寿命。通过仿真实验,验证了控制方法的有效性。
文摘模块化多电平换流器高压直流输电(modular multilevel converter based high voltage direct current,MMC-HVDC)由于具备自换相能力,尤其适用于向弱交流电网供电。交流系统强度降低时,会制约系统的直流功率传输能力,甚至导致系统失稳。针对联接弱交流电网时MMC-HVDC系统功率传输受限的问题,建立了状态空间与直流阻抗模型,从时域、频域两方面研究了交流系统强度对直流功率传输能力的影响,明确了弱交流电网工况下功率传输受限的原因。基于参与因子定位结果,提出了在定直流电压控制环节引入直流电流反馈的功率传输能力提升方法,从时域、频域两方面对控制策略的提升作用进行了机理分析,并定量得出了控制参数的可行域及功率传输能力的最大提升水平。该方法在避免稳态误差的前提下,有效提升了MMC-HVDC系统的直流功率传输能力。