This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of i...This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of improved performance of HVDC systems in terms of betterpower quality, high power factor, and lower total harmonic distortion (THD).The system under analysis consists of an 878 km long HVDC transmissionline connecting converter stations at Matiari and Lahore, two major cities inPakistan. The main focus of this research is to design a novel AC filter usingthe equivalent impedance method of two single-tuned and double-dampedtuned AC filters. Additionally, the impact of the damping resistor on the ACchannel is examined. TheTHDof theHVDCsystem with and without currentAC filters was also compared in this research and a double-damped tuned ACfilter was proposed. The results of the simulation represent that the proposeddouble-damped tuned AC filter is far smaller in size, offers better powerquality, and has a much lower THD compared to the AC filters currently inplace in the converter station. The simulation analysis was carried out utilizingpower systems computer-aided design (PSCAD) software.展开更多
Holding the greatest power transmission capacity in China, Three Gorges power transmission and substation (T&S) project is an important landmark in the
模块化多电平换流器高压直流输电(modular multilevel converter based high voltage direct current,MMC-HVDC)由于具备自换相能力,尤其适用于向弱交流电网供电。交流系统强度降低时,会制约系统的直流功率传输能力,甚至导致系统失稳。...模块化多电平换流器高压直流输电(modular multilevel converter based high voltage direct current,MMC-HVDC)由于具备自换相能力,尤其适用于向弱交流电网供电。交流系统强度降低时,会制约系统的直流功率传输能力,甚至导致系统失稳。针对联接弱交流电网时MMC-HVDC系统功率传输受限的问题,建立了状态空间与直流阻抗模型,从时域、频域两方面研究了交流系统强度对直流功率传输能力的影响,明确了弱交流电网工况下功率传输受限的原因。基于参与因子定位结果,提出了在定直流电压控制环节引入直流电流反馈的功率传输能力提升方法,从时域、频域两方面对控制策略的提升作用进行了机理分析,并定量得出了控制参数的可行域及功率传输能力的最大提升水平。该方法在避免稳态误差的前提下,有效提升了MMC-HVDC系统的直流功率传输能力。展开更多
This paper presents performance analysis on hybrid AC/DC microgrid networks for residential home cluster. The design of the proposed microgrid includes comprehensive types of Distributed Generators (DGs) as hybrid pow...This paper presents performance analysis on hybrid AC/DC microgrid networks for residential home cluster. The design of the proposed microgrid includes comprehensive types of Distributed Generators (DGs) as hybrid power sources (wind, Photovoltaic (PV) solar cell, battery, fuel cell). Details about each DG dynamic modeling are presented and discussed. The customers in home cluster can be connected in both of the operating modes: islanded to the microgrid or connected to utility grid. Each DG has appended control system with its modeling that will be discussed to control DG performance. The wind turbine will be controlled by AC control system within three sub-control systems: 1) speed regulator and pitch control, 2) rotor side converter control, and 3) grid side converter control. The AC control structure is based on PLL, current regulator and voltage booster converter with using of photovoltaic Voltage Source Converter (VSC) and inverters to connect to the grid. The DC control system is mainly based on Maximum Power Point Tracking (MPPT) controller and boost converter connected to the PV array block and in order to control the system. The case study is used to analyze the performance of the proposed microgrid. The buses voltages, active power and reactive power responses are presented in both of grid-connected and islanded modes. In addition, the power factor, Total Harmonic Distortion (THD) and modulation index are calculated.展开更多
As the steady-state frequency of an actual power system decreases from its nominal value,the composite load of the system generally responds positively to lower power consumption,and vice versa.It is believed that thi...As the steady-state frequency of an actual power system decreases from its nominal value,the composite load of the system generally responds positively to lower power consumption,and vice versa.It is believed that this load frequency damping(LFD)effect will be artificially enhanced,i.e.,sensitivities of loads with respect to operational frequency will increase,in future power systems.Thus,for wind-integrated power systems,this paper proposes a frequency-dependent chance constrained unit commitment(FDCCUC)model that employs the operational frequency as a dispatching variable so that the LFD effect-based load power can act as a supplemental reserve.Because the frequency deviation is safely restricted,this low-cost reserve can be sufficiently exerted to upgrade the wind power accommodation capability of a power system that is normally confined by an inadequate reserve to cope with uncertain wind power forecasting error.Moreover,when the FDCCUC model is applied to a bulk AC/DC hybrid power system consisting of several independently operated regional AC grids interconnected by DC tie-lines,a hierarchically implemented searching algorithm is proposed to protect private scheduling information of the regional AC grids.Simulations on a 2-area 6-bus system and a 3-area 354-bus system verify the effectiveness of the FDCCUC model and hierarchical searching algorithm.展开更多
为提高风电场交直流混合输电并网的系统性能,提出一种更加灵活的电压源换流器高压直流(voltage source converter based high voltage direct current,VSC-HVDC)控制策略。对于风电场侧电压源换流器,设计了一种新的交流电压–功角控制...为提高风电场交直流混合输电并网的系统性能,提出一种更加灵活的电压源换流器高压直流(voltage source converter based high voltage direct current,VSC-HVDC)控制策略。对于风电场侧电压源换流器,设计了一种新的交流电压–功角控制方法。对于交直流混合输电模式,该方法通过调节风电场交流母线电压与电压源换流器输出电压间的功角来实现定有功功率控制。对于纯柔性直流输电模式,风电场交流母线电压自动被调节为具有恒幅恒频的交流电压,实现了对波动风电的同步输送。该方法中输电模式的变化无需切换控制;另外,通过附加电流高通滤波器增强了对系统谐振的阻尼作用。对电网侧电压源换流器,采用一种新的直接电流矢量控制,使直流电压稳定在参考值上。运用PSCAD/EMTDC仿真软件对分别接入笼型感应发电机(squirrel cage induction generator,SCIG)风电场和双馈感应发电机(doubly fed induction generator,DFIG)风电场的交直流混合输电系统建模仿真。一系列运行条件下的仿真结果验证了控制方法的有效性与可行性。展开更多
基于电压源换流器高压直流输电(voltage source converter based HVDC,VSC-HVDC)的直流系统存在与交流线路并联运行的情况。交直流系统之间相互切换的运行工况复杂,且切换过程存在切换依据难以确定、切换冲击大以及通信延时等问题。为...基于电压源换流器高压直流输电(voltage source converter based HVDC,VSC-HVDC)的直流系统存在与交流线路并联运行的情况。交直流系统之间相互切换的运行工况复杂,且切换过程存在切换依据难以确定、切换冲击大以及通信延时等问题。为解决该问题,在分析VSC-HVDC工作原理、数学模型及其控制策略的基础上,提出了一种大型风电场经VSC-HVDC交直流并联系统并网的运行控制策略,该策略在不改变换流站控制方式的情况下,可实现交直流并联系统运行方式的无缝切换。基于MATLAB/Simulink仿真软件,建立了系统仿真模型,对交直流并联系统稳态运行及动态切换过程进行了仿真分析。仿真结果表明,所提出的控制策略能够较好地实现交直流并联系统有功功率的精确分配和运行方式的无缝切换,算法简单,可靠性高。展开更多
基金supported by Creative Challenge Research Program (2021R1I1A1A01052521)the BK-21 FOUR program through the National Research Foundation of Korea (NRF)under the Ministry of Education.
文摘This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of improved performance of HVDC systems in terms of betterpower quality, high power factor, and lower total harmonic distortion (THD).The system under analysis consists of an 878 km long HVDC transmissionline connecting converter stations at Matiari and Lahore, two major cities inPakistan. The main focus of this research is to design a novel AC filter usingthe equivalent impedance method of two single-tuned and double-dampedtuned AC filters. Additionally, the impact of the damping resistor on the ACchannel is examined. TheTHDof theHVDCsystem with and without currentAC filters was also compared in this research and a double-damped tuned ACfilter was proposed. The results of the simulation represent that the proposeddouble-damped tuned AC filter is far smaller in size, offers better powerquality, and has a much lower THD compared to the AC filters currently inplace in the converter station. The simulation analysis was carried out utilizingpower systems computer-aided design (PSCAD) software.
文摘Holding the greatest power transmission capacity in China, Three Gorges power transmission and substation (T&S) project is an important landmark in the
文摘模块化多电平换流器高压直流输电(modular multilevel converter based high voltage direct current,MMC-HVDC)由于具备自换相能力,尤其适用于向弱交流电网供电。交流系统强度降低时,会制约系统的直流功率传输能力,甚至导致系统失稳。针对联接弱交流电网时MMC-HVDC系统功率传输受限的问题,建立了状态空间与直流阻抗模型,从时域、频域两方面研究了交流系统强度对直流功率传输能力的影响,明确了弱交流电网工况下功率传输受限的原因。基于参与因子定位结果,提出了在定直流电压控制环节引入直流电流反馈的功率传输能力提升方法,从时域、频域两方面对控制策略的提升作用进行了机理分析,并定量得出了控制参数的可行域及功率传输能力的最大提升水平。该方法在避免稳态误差的前提下,有效提升了MMC-HVDC系统的直流功率传输能力。
文摘This paper presents performance analysis on hybrid AC/DC microgrid networks for residential home cluster. The design of the proposed microgrid includes comprehensive types of Distributed Generators (DGs) as hybrid power sources (wind, Photovoltaic (PV) solar cell, battery, fuel cell). Details about each DG dynamic modeling are presented and discussed. The customers in home cluster can be connected in both of the operating modes: islanded to the microgrid or connected to utility grid. Each DG has appended control system with its modeling that will be discussed to control DG performance. The wind turbine will be controlled by AC control system within three sub-control systems: 1) speed regulator and pitch control, 2) rotor side converter control, and 3) grid side converter control. The AC control structure is based on PLL, current regulator and voltage booster converter with using of photovoltaic Voltage Source Converter (VSC) and inverters to connect to the grid. The DC control system is mainly based on Maximum Power Point Tracking (MPPT) controller and boost converter connected to the PV array block and in order to control the system. The case study is used to analyze the performance of the proposed microgrid. The buses voltages, active power and reactive power responses are presented in both of grid-connected and islanded modes. In addition, the power factor, Total Harmonic Distortion (THD) and modulation index are calculated.
基金supported by the National Natural Science Foundation of China(No.51777143)。
文摘As the steady-state frequency of an actual power system decreases from its nominal value,the composite load of the system generally responds positively to lower power consumption,and vice versa.It is believed that this load frequency damping(LFD)effect will be artificially enhanced,i.e.,sensitivities of loads with respect to operational frequency will increase,in future power systems.Thus,for wind-integrated power systems,this paper proposes a frequency-dependent chance constrained unit commitment(FDCCUC)model that employs the operational frequency as a dispatching variable so that the LFD effect-based load power can act as a supplemental reserve.Because the frequency deviation is safely restricted,this low-cost reserve can be sufficiently exerted to upgrade the wind power accommodation capability of a power system that is normally confined by an inadequate reserve to cope with uncertain wind power forecasting error.Moreover,when the FDCCUC model is applied to a bulk AC/DC hybrid power system consisting of several independently operated regional AC grids interconnected by DC tie-lines,a hierarchically implemented searching algorithm is proposed to protect private scheduling information of the regional AC grids.Simulations on a 2-area 6-bus system and a 3-area 354-bus system verify the effectiveness of the FDCCUC model and hierarchical searching algorithm.
文摘为提高风电场交直流混合输电并网的系统性能,提出一种更加灵活的电压源换流器高压直流(voltage source converter based high voltage direct current,VSC-HVDC)控制策略。对于风电场侧电压源换流器,设计了一种新的交流电压–功角控制方法。对于交直流混合输电模式,该方法通过调节风电场交流母线电压与电压源换流器输出电压间的功角来实现定有功功率控制。对于纯柔性直流输电模式,风电场交流母线电压自动被调节为具有恒幅恒频的交流电压,实现了对波动风电的同步输送。该方法中输电模式的变化无需切换控制;另外,通过附加电流高通滤波器增强了对系统谐振的阻尼作用。对电网侧电压源换流器,采用一种新的直接电流矢量控制,使直流电压稳定在参考值上。运用PSCAD/EMTDC仿真软件对分别接入笼型感应发电机(squirrel cage induction generator,SCIG)风电场和双馈感应发电机(doubly fed induction generator,DFIG)风电场的交直流混合输电系统建模仿真。一系列运行条件下的仿真结果验证了控制方法的有效性与可行性。
文摘基于电压源换流器高压直流输电(voltage source converter based HVDC,VSC-HVDC)的直流系统存在与交流线路并联运行的情况。交直流系统之间相互切换的运行工况复杂,且切换过程存在切换依据难以确定、切换冲击大以及通信延时等问题。为解决该问题,在分析VSC-HVDC工作原理、数学模型及其控制策略的基础上,提出了一种大型风电场经VSC-HVDC交直流并联系统并网的运行控制策略,该策略在不改变换流站控制方式的情况下,可实现交直流并联系统运行方式的无缝切换。基于MATLAB/Simulink仿真软件,建立了系统仿真模型,对交直流并联系统稳态运行及动态切换过程进行了仿真分析。仿真结果表明,所提出的控制策略能够较好地实现交直流并联系统有功功率的精确分配和运行方式的无缝切换,算法简单,可靠性高。