期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Development of Super-Synchronization Speed Control Assembly in Two 80 MVA Motor Generators of HL-2A Tokamak
1
作者 LI Huajun DU Chang +9 位作者 XUAN Weimin PEN Jianfei HU Haotian LIU Lin KANG Li XU Lirong HUANG Zhaorong WANG Fen WANG Xiaoping WANG Haibing 《Southwestern Institute of Physics Annual Report》 2005年第1期71-73,共3页
The power of the toroidal field (TF) coil in HL-2A is supplied with two 80 MVA motor generators (MGs) together through a diode rectifier. The TF system is designed to obtain the parameters as follows: the highest... The power of the toroidal field (TF) coil in HL-2A is supplied with two 80 MVA motor generators (MGs) together through a diode rectifier. The TF system is designed to obtain the parameters as follows: the highest toroidal filed of 2.8 T, the biggest coil current of 45 kA, the fiat top time of 3-5 s. So the released energy of each MG set for one pulse discharge mast be more than 500 MJ. 展开更多
关键词 Double fed drive motor ac-ac cycloconverte Vector control
下载PDF
Modified PI Controller with Improved Steady-State Performance and Comparison with PR Controller on Direct Matrix Converters 被引量:2
2
作者 Jianwei Zhang Li Li +1 位作者 David G.Dorrell Youguang Guo 《Chinese Journal of Electrical Engineering》 CSCD 2019年第1期53-66,共14页
This paper proposes a modified proportional-integral(PI)controller and compares it with a proportional-resonant(PR)controller.These controllers are tested on a three-phase direct matrix converter(MC).The modified PI c... This paper proposes a modified proportional-integral(PI)controller and compares it with a proportional-resonant(PR)controller.These controllers are tested on a three-phase direct matrix converter(MC).The modified PI controller involves current feedforward together with space vector modulation(SVM)to control the MC output currents.This controller provides extra control flexibility in terms of the current error reduction,and it gives improved steady-state tracking performance.When the coefficient of current feedforward is equal to the load resistor(K=R),the steady-state error is effectively minimized even when regulating sinusoidal variables.The total harmonic distortion is also reduced.In order to comparatively evaluate the modified PI controller,a PR controller is designed and tested.Both the modified PI and PR controllers are implemented in the natural frame(abc)in a straightforward manner.This removes the coordinate transformations that are required in the stationary(αβ)and synchronous(dq)reference frame based control strategies.In addition,both controllers can handle the unbalanced conditions.The experimental and simulation results verify the feasibility and effectiveness of the proposed controllers. 展开更多
关键词 Matrix CONVERTER ac-ac CONVERSION STEADY-STATE error PI controlLER PR controlLER
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部