NT build 443, or profile fitting method, is often used to measure the diffusion coefficient of chloride in concrete. However, this method is quite laborious and needs special equipment. Colorimetric method is a quick ...NT build 443, or profile fitting method, is often used to measure the diffusion coefficient of chloride in concrete. However, this method is quite laborious and needs special equipment. Colorimetric method is a quick and simple method to measure the penetration depth of chloride by spraying 0.1 mol/L silver nitrate solution. The objective of this work is to study the possibility of the use of colorimetric method in the calculation of non-steady-state diffusion coefficient. Twelve concrete mixtures with different supplementary cementitious materials and water-to-cement ratios of 0.35, 0.48 and 0.6 were used for study. According to NT build 443, the concrete specimens were immersed in 165 g/L NaC1 (2.8 mol/L) solution for 42 d. Both water-soluble (convert to free chloride) chloride and acid-soluble chloride at different layers of specimens were measured. The results show that the mean value of free chloride concentration at the color change boundary Cd was 0.306 mol/L. The surface free chloride concentration cs was obtained by profile fitting method, which was 40% lower than the chloride concentration of exposure solution after an immersion period of 42 d. Chloride diffusion coefficients obtained by the colorimetric method was not well correlated with those obtained by profile fitting method.展开更多
A simple, rapid and precise method has been developed for determination of lipase activity in microbial media. The method is based on using phenyl acetate as substrate for lipase and determination of liberated phenol ...A simple, rapid and precise method has been developed for determination of lipase activity in microbial media. The method is based on using phenyl acetate as substrate for lipase and determination of liberated phenol by Folin Ciocalteu reagent. Reaction mixture containing substrate 2.4 ml of phenyl acetate 165 μM in Tris HCl buffer, 0.1 M and pH 7, with 1% (v/v) Triton X-100) and 0.1 ml lipase is incubated at 40?C during 10 minutes and the absorbance was measured at 750 nm. Linearity was observed in the concentration range 0-0.8 g/L lipase.展开更多
This study aims to evaluate the presence of free chlorides by the silver nitrate colorimetric spraying method in mortars made with Portland cement CP II Z-32. In order to make an assessment beyond the qualitative anal...This study aims to evaluate the presence of free chlorides by the silver nitrate colorimetric spraying method in mortars made with Portland cement CP II Z-32. In order to make an assessment beyond the qualitative analysis, a calculation of the contaminated areas by free chlorides was performed by measuring the regions using a computer image analysis software (IMAGEJ). The experimental part of the research involved samples of 5 cm x 10 cm of mortar and 0.1 M solution of silver nitrate in distilled water. The mortar samples were made with cement CP II Z-32 with the following concentrations of chloride incorporated into the mixing water: 0%0, 0.4%, 0.6%, 0.8%, 1.0% and 2.0%, in relation to the mass of cement, totaling 108 samples. The average of percentage results from the contaminated area of the series of samples was respectively 0%, 14.9694%, 19.7444%, 46.0239%, 62.3311% and 96.0083% in relation to the total area, concluding that the method of silver nitrate spraying is applicable and that the white color indicates the presence of chloride ions and other possible aggressive salts to the structure or the concrete.展开更多
基金Project(2010QZZD018) supported by Central South Universtiy,China,and Ghent University,Belgium
文摘NT build 443, or profile fitting method, is often used to measure the diffusion coefficient of chloride in concrete. However, this method is quite laborious and needs special equipment. Colorimetric method is a quick and simple method to measure the penetration depth of chloride by spraying 0.1 mol/L silver nitrate solution. The objective of this work is to study the possibility of the use of colorimetric method in the calculation of non-steady-state diffusion coefficient. Twelve concrete mixtures with different supplementary cementitious materials and water-to-cement ratios of 0.35, 0.48 and 0.6 were used for study. According to NT build 443, the concrete specimens were immersed in 165 g/L NaC1 (2.8 mol/L) solution for 42 d. Both water-soluble (convert to free chloride) chloride and acid-soluble chloride at different layers of specimens were measured. The results show that the mean value of free chloride concentration at the color change boundary Cd was 0.306 mol/L. The surface free chloride concentration cs was obtained by profile fitting method, which was 40% lower than the chloride concentration of exposure solution after an immersion period of 42 d. Chloride diffusion coefficients obtained by the colorimetric method was not well correlated with those obtained by profile fitting method.
文摘A simple, rapid and precise method has been developed for determination of lipase activity in microbial media. The method is based on using phenyl acetate as substrate for lipase and determination of liberated phenol by Folin Ciocalteu reagent. Reaction mixture containing substrate 2.4 ml of phenyl acetate 165 μM in Tris HCl buffer, 0.1 M and pH 7, with 1% (v/v) Triton X-100) and 0.1 ml lipase is incubated at 40?C during 10 minutes and the absorbance was measured at 750 nm. Linearity was observed in the concentration range 0-0.8 g/L lipase.
文摘This study aims to evaluate the presence of free chlorides by the silver nitrate colorimetric spraying method in mortars made with Portland cement CP II Z-32. In order to make an assessment beyond the qualitative analysis, a calculation of the contaminated areas by free chlorides was performed by measuring the regions using a computer image analysis software (IMAGEJ). The experimental part of the research involved samples of 5 cm x 10 cm of mortar and 0.1 M solution of silver nitrate in distilled water. The mortar samples were made with cement CP II Z-32 with the following concentrations of chloride incorporated into the mixing water: 0%0, 0.4%, 0.6%, 0.8%, 1.0% and 2.0%, in relation to the mass of cement, totaling 108 samples. The average of percentage results from the contaminated area of the series of samples was respectively 0%, 14.9694%, 19.7444%, 46.0239%, 62.3311% and 96.0083% in relation to the total area, concluding that the method of silver nitrate spraying is applicable and that the white color indicates the presence of chloride ions and other possible aggressive salts to the structure or the concrete.