The performance of Smith prediction monitoring automatic gauge control(AGC) system is influenced by model mismatching greatly in strip rolling process. Aiming at this problem, a feedback-assisted iterative learning co...The performance of Smith prediction monitoring automatic gauge control(AGC) system is influenced by model mismatching greatly in strip rolling process. Aiming at this problem, a feedback-assisted iterative learning control strategy, which learned unknown modeling error by using previous control information repeatedly, was introduced into Smith prediction monitoring AGC system. Firstly, conventional Smith predictor and improved Smith predictor with PI-P controller were analyzed. Secondly, on the basis of establishing of feedback-assisted iterative learning control strategy for improved Smith predictor, process control signal update law and control error were deduced, then convergence condition of this strategy was put forward and proved. Finally, after modeling the automatic position control system, the PI-P Smith prediction monitoring AGC system with feedback-assisted iterative learning control was researched through simulation. Simulation results indicate that this system remains stable during model mismatching. The robustness and response of monitoring AGC is improved by development of feedback-assisted iterative learning control strategy for PI-P Smith predictor.展开更多
In order to effectively control the working state of the gyroscope in drive mode, the drive characteristics of the micro electromechanical system (MEMS) gyroscope are analyzed in principle. A novel drive circuit for...In order to effectively control the working state of the gyroscope in drive mode, the drive characteristics of the micro electromechanical system (MEMS) gyroscope are analyzed in principle. A novel drive circuit for the MEMS gyroscope in digital closed-loop control is proposed, which utilizes a digital phase-locked loop (PLL) in frequency control and an automatic gain control (AGC) method in amplitude control. A digital processing circuit with a field programmable gate array (FPGA) is designed and the experiments are carried out. The results indicate that when the temperature changes, the drive frequency can automatically track the resonant frequency of gyroscope in drive mode and that of the oscillating amplitude holds at a set value. And at room temperature, the relative deviation of the drive frequency is 0.624 ×10^-6 and the oscillating amplitude is 8.0 ×10^-6, which are 0. 094% and 18. 39% of the analog control program, respectively. Therefore, the control solution of the digital PLL in frequency and the AGC in amplitude is feasible.展开更多
Essentially, it is significant to supply the consumer with reliable and sufficient power. Since, power quality is measured by the consistency in frequency and power flow between control areas. Thus, in a power system ...Essentially, it is significant to supply the consumer with reliable and sufficient power. Since, power quality is measured by the consistency in frequency and power flow between control areas. Thus, in a power system operation and control,automatic generation control(AGC) plays a crucial role. In this paper, multi-area(Five areas: area 1, area 2, area 3, area 4 and area 5) reheat thermal power systems are considered with proportional-integral-derivative(PID) controller as a supplementary controller. Each area in the investigated power system is equipped with appropriate governor unit, turbine with reheater unit, generator and speed regulator unit. The PID controller parameters are optimized by considering nature bio-inspired firefly algorithm(FFA). The experimental results demonstrated the comparison of the proposed system performance(FFA-PID)with optimized PID controller based genetic algorithm(GAPID) and particle swarm optimization(PSO) technique(PSOPID) for the same investigated power system. The results proved the efficiency of employing the integral time absolute error(ITAE) cost function with one percent step load perturbation(1 % SLP) in area 1. The proposed system based FFA achieved the least settling time compared to using the GA or the PSO algorithms, while, it attained good results with respect to the peak overshoot/undershoot. In addition, the FFA performance is improved with the increased number of iterations which outperformed the other optimization algorithms based controller.展开更多
This paper presents an innovative switched-mode auto gain control (AGC) circuit with internally created reset module for DC-10Mb/s burst-mode unbalanced (BMU) optical data transmission. Conventional AGC circuit is...This paper presents an innovative switched-mode auto gain control (AGC) circuit with internally created reset module for DC-10Mb/s burst-mode unbalanced (BMU) optical data transmission. Conventional AGC circuit is inappropriate for BMU data transmission because it is based on average level detection and requires considerable time to settle on a predefined gain. Therefore, we adopt a fast switched-mode AGC based on peak level detection. After the gain is adjusted, the peak level detectors need to re-detect the peak level of the input signal. Thus, we develop an internally created reset module. This AGC with reset module exhibits a fast operation and achieves an adjusted stable gain within one-bit, avoiding any bit loss up to 10Mb/s data rate. During power-up, the peak level detectors possibly hold an uncertain level resulting in the bit-errors. We propose a power-up reset circuit to solve this problem. Designed in a 0.5μm CMOS technology, the circuit achieves an optical sensitivity of better than -30dBm and a wide dynamic range of over 30dB with a power dissipation of only 30 mW from a 5V supply.展开更多
Since wind power has the features of being intermittent and unpredictable, and usually needs transmission over long distances, grid integration of large-scale wind power will exert signif icant influence on power grid...Since wind power has the features of being intermittent and unpredictable, and usually needs transmission over long distances, grid integration of large-scale wind power will exert signif icant influence on power grid planning and construction, and will make a heavy impact on the safe and reliable operation of power systems. To deal with the diff iculties of large scale wind power dispatch, this paper presents a new automatic generation control (AGC) scheme that involves the participation of wind farms. The scheme is based on ultra-short-term wind power forecast. The author establishes a generation output distribution optimization mode for the power system with wind farms and verif ies the feasibility of the scheme by an example.展开更多
Conventional techniques to control variations within one plate have been based on preset models and constant automatic position control (APC or pressure feedback automatic gauge control(PAGC).However.because of the r...Conventional techniques to control variations within one plate have been based on preset models and constant automatic position control (APC or pressure feedback automatic gauge control(PAGC).However.because of the rolling force prediction error in the preset models and of the inadequate response speed of dynamic system and of the eccentricity, etc.,the conventional method has not given satisfactory results, the statistics'variations within one plate are in range of 0.25-0.60 mm The authors have developed the techniques to control the variations, which are dynamic intelligent control of hydraulic screwdown system. synchronism control of hydraulic screwdown, eccentricity control method by rotary encoder and the curve of modulus of mill measured automatically, etc., The techniques were fully and successfully industrialized in The Plate Mill of Maanshan Iron and Steel Company and good results that variations are in range of 0.08-0.15min hare been obtained in that mill.展开更多
Present day power scenarios demand a high quality uninterrupted power supply and needs environmental issues to be addressed. Both concerns can be dealt with by the introduction of the renewable sources to the existing...Present day power scenarios demand a high quality uninterrupted power supply and needs environmental issues to be addressed. Both concerns can be dealt with by the introduction of the renewable sources to the existing power system. Thus, automatic generation control(AGC) with diverse renewable sources and a modified-cascaded controller are presented in the paper.Also, a new hybrid scheme of the improved teaching learning based optimization-differential evolution(hITLBO-DE) algorithm is applied for providing optimization of controller parameters. A study of the system with a technique such as TLBO applied to a proportional integral derivative(PID), integral double derivative(IDD) and PIDD is compared to hITLBO-DE tuned cascaded controller with dynamic load change.The suggested methodology has been extensively applied to a 2-area system with a diverse source power system with various operation time non-linearities such as dead-band of, generation rate constraint and reheat thermal units. The multi-area system with reheat thermal plants, hydel plants and a unit of a wind-diesel combination is tested with the cascaded controller scheme with a different controller setting for each area. The variation of the load is taken within 1% to 5% of the connected load and robustness analysis is shown by modifying essential factors simultaneously by± 30%. Finally, the proposed scheme of controller and optimization technique is also tested with a 5-equal area thermal system with non-linearities. The simulation results demonstrate the superiority of the proposed controller and algorithm under a dynamically changing load.展开更多
For anti-jamming and anti-countermeasure techniques of the sonar receiver, the response characteristics of the automatic gain control (AGC) circuit and the survivability of the prime circuit under strong interferenc...For anti-jamming and anti-countermeasure techniques of the sonar receiver, the response characteristics of the automatic gain control (AGC) circuit and the survivability of the prime circuit under strong interference are analyzed by simulations and experiments. An AGC simulation model based on the voltage control amplifier VCA810 prototype is proposed. Then static and dynamic simulations are realized with single frequency signal and linear frequency modulated (LFM) signal commonly used in the active sonar. Based on intense sound pulse (ISP) interference experiments, the real-time response characteristics of each module of the receiver are studied to verify the correctness of the model as well as the simulation results. Simulation and experiment results show that, under 252 dB/20 μs ISP interference, the specific sonar receiver will produce sustained cut top oscillation above 30 ms, which may affect the receiver and block the regular sonar signal.展开更多
A 6.25 Gbps SerDes core used in the high signed based on the OIF-CEI-02.0 standard. To speed backplane communication receiver has been decounteract the serious Inter-Syrmbol-Interference (ISI), the core employed a h...A 6.25 Gbps SerDes core used in the high signed based on the OIF-CEI-02.0 standard. To speed backplane communication receiver has been decounteract the serious Inter-Syrmbol-Interference (ISI), the core employed a half-rate four-tap decision feedback equalizer (DFE). The equalizer used the Signsign least mean-squared (SS-LMS) algorithm to realize the coefficient adaptation. An automatic gain control (AGC) amplifier with the sign least mean-squared (S-LMS) algorithm has been used to compensate the transmission media loss. To recover the clock signal from the input data serial and provide for the DFE and AGC, a bang-bang clock recovery (BB-CR) is adopted. A third order phase loop loek (PLL) model was proposed to predict characteristics of the BB-CR. The core has been verified by behavioral modeling in MATLAB. The results indicate that the core can meet the specifications of the backplane receiver. The DFE recovered data over a 34" FR-4 backplane has a peak-to-peak jitter of 17 ps, a horizontal eye opening of 0.87 UI, and a vertical eye opening of 500 mVpp.展开更多
This paper presented an automatic gain control (AGC) circuit suitable for FM/cw ladar. The proposed architecture was based on two-stage variable gain amplifier (VGA) chain with a novel DC offset canceller circuit,...This paper presented an automatic gain control (AGC) circuit suitable for FM/cw ladar. The proposed architecture was based on two-stage variable gain amplifier (VGA) chain with a novel DC offset canceller circuit, which contained an improved Gilbert cell and a Gm-C feedback loop. To keep the VGA with a linearity in dB characteristic, an improved exponential gain control circuit was introduced. The AGC was implemented in 0.18 gm standard CMOS process. Simulation and measurement results verified that its gain ranged from -20 dB to 30 dB, and band- width ranged from 100 kHz to 10 MHz. Its power consumption was 19.8 mW under a voltage supply of 3.3 V.展开更多
Automatic gauge control(AGC in the article)is the key technology of product thickness accuracy and flatness quality in modern cold rolling mill.Most traditional AGC control algorithms need stable external system condi...Automatic gauge control(AGC in the article)is the key technology of product thickness accuracy and flatness quality in modern cold rolling mill.Most traditional AGC control algorithms need stable external system conditions and hard to stabilize under complex interference that meets coverage requirements.This paper presents a new anti-interference strategy for AGC control of 20-Hi cold reversing mill.The proposed algorithm introduces a united dynamic weights algorithm of feed forward-mass flow to avoid the complex interference problem in AGC control,the relevant control strategy is provided to eliminate the adverse effects.At the same time,the D-value between feed forward-mass flow pre-computation and thickness measurement deviation is dynamic compared,the final gap position regulation is calculated by developing a set of united dynamic weights between feed forward control and mass flow control.Finally,the output of controllers is sent to actuator though a constant rate smoothing.The proposed strategy is compared with conventional AGC control on Experimental platform and project application,the results show that the proposed strategy is more stable than comparison method and majority of system uncertainty produced by mentioned interference is significantly eliminated.展开更多
An appropriate acquisition configuration in terms of signal quality can optimize the acquisition performance. In view of this, a new approach of acquisition assisted by the control voltage of automatic gain control(AG...An appropriate acquisition configuration in terms of signal quality can optimize the acquisition performance. In view of this, a new approach of acquisition assisted by the control voltage of automatic gain control(AGC) is proposed. This approach judges the signal power according to the AGC control voltage and switches the working modes correspondingly and adaptively. Non-coherent accumulation times and the detection threshold are reconfigured according to the working mode. Theoretical derivation and verification by simulation in typical situations are provided, and the algorithm is shown to be superior in terms of the mean acquisition time, especially in strong signal scenarios compared with the conventional algorithm.展开更多
With an increasing penetration of wind power in the modern electrical grid, the increasing replacement of large conventional synchronous generators by wind power plants will potentially result in deteriorated frequenc...With an increasing penetration of wind power in the modern electrical grid, the increasing replacement of large conventional synchronous generators by wind power plants will potentially result in deteriorated frequency regulation performance due to the reduced system inertia and primary frequency response. A series of challenging issues arise from the aspects of power system planning,operation, control and protection. Therefore, it is valuable to develop variable speed wind turbines(VSWTs) equipped with frequency regulation capabilities that allow them to effectively participate in addressing severe frequency contingencies. This paper provides a comprehensive surveyon frequency regulation methods for VSWTs. It fully describes the concepts, principles and control strategies of prevailing frequency controls of VSWTs, including future development trends. It concludes with a performance comparison of frequency regulation by the four main types of wind power plants.展开更多
The high penetration of wind energy sources in power systems has substantially increased the demand for faster-ramping thermal units participating in the frequency regulation service.To fulfill the automatic generatio...The high penetration of wind energy sources in power systems has substantially increased the demand for faster-ramping thermal units participating in the frequency regulation service.To fulfill the automatic generation control(AGC)and compensate the influence of wind power fluctuations simultaneously,ramping capacity should be considered in the dispatch model of thermals.Meanwhile,conventional methods in this area do not take the impact of transmission loss into the dispatch model,or rely on offline network model and parameters,failing to reflect the real relationships between the wind farms and thermal generators.This paper proposes an online approach for AGC dispatch units considering the above issues.Firstly,the power loss sensitivity is online identified using recursive least square method based on the real-time data of phasor measurement units.It sets up power balance constraint and results in a more accurate dispatch model.Then,an improved multi-objective optimization model of dispatch is proposed and a connection is established between the thermal units with fast ramping capacity and the wind farms with rapid fluctuations.Genetic algorithm is used to solve the dispatch model.The proposed method is compared with conventional methods in simulation case in the IEEE 30-bus system.Finally,simulation results verify the validity and the feasibility of identification method and optimization model.展开更多
Communication plays a vital role in incorporating smartness into the interconnected power system.However,historical records prove that the data transfer has always been vulnerable to cyber-attacks.Unless these cyber-a...Communication plays a vital role in incorporating smartness into the interconnected power system.However,historical records prove that the data transfer has always been vulnerable to cyber-attacks.Unless these cyber-attacks are identified and cordoned off,they may lead to black-out and result in national security issues.This paper proposes an optimal two-stage Kalman filter(OTS-KF)for simultaneous state and cyber-attack estimation in automatic generation control(AGC)system.Biases/cyber-attacks are modeled as unknown inputs in the AGC dynamics.Five types of cyber-attacks,i.e.,false data injection(FDI),data replay attack,denial of service(DoS),scaling,and ramp attacks,are injected into the measurements and estimated using OTS-KF.As the load variations of each area are seldom available,OTS-KF is reformulated to estimate the states and outliers along with the load variations of the system.The proposed technique is validated on the benchmark two-area,three-area,and five-area power system models.The simulation results under various test conditions demonstrate the efficacy of the proposed filter.展开更多
Highly wind power integrated power system requires continuous active power regulation to tackle the power imbalances resulting from the wind power forecast errors. The active power balance is maintained in real-time w...Highly wind power integrated power system requires continuous active power regulation to tackle the power imbalances resulting from the wind power forecast errors. The active power balance is maintained in real-time with the automatic generation control and also from the control room, where regulating power bids are activated manually. In this article, an algorithm is developed to simulate the activation of regulating power bids, as performed in the control room, during power imbalance between generation and load demand. In addition, the active power balance is also controlled through automatic generation control, where coordinated control strategy between combined heat and power plants and wind power plant enhances the secure power system operation. The developed algorithm emulating the control room response,to deal with real-time power imbalance, is applied and investigated on the future Danish power system model. The power system model takes the hour-ahead regulating power plan from power balancing model and the generation and power exchange capacities for the year 2020 into account.The real-time impact of power balancing in a highly wind power integrated power system is assessed and discussed by means of simulations for different possible scenarios.展开更多
In this paper, a fractional order proportional integral derivative (FOPID) controller for multiarea automatic generation control (AGC) scheme has been designed. FOPID controller has five parameters and provides tw...In this paper, a fractional order proportional integral derivative (FOPID) controller for multiarea automatic generation control (AGC) scheme has been designed. FOPID controller has five parameters and provides two additional degrees of flexibility in comparison to a proportional integral derivative (PID) controller. The optimal values of parameters of FOPID controller have been determined using Big Bang Big Crunch (BBBC) search algorithm. The designed controller regulates real power output of generators to achieve the best dynamic response of frequency and tie-line power on a load perturbation. The complete scheme for designing of the controllers has been developed and demonstrated on multiarea deregulated power system. The performance of the designed FOPID controllers has been compared with the optimally tuned PID controllers. It is observed from the results that the FOPID controller shows a considerable improvement in the performance as compared to the conventional PID controller.展开更多
Suppression of the dynamic oscillations of tie-line power exchanges and frequency in the affected interconnected power systems due to loading-condition changes has been assigned as a prominent duty of automatic genera...Suppression of the dynamic oscillations of tie-line power exchanges and frequency in the affected interconnected power systems due to loading-condition changes has been assigned as a prominent duty of automatic generation control(AGC). To alleviate the system oscillation resulting from such load changes, implementation of flexible AC transmission systems(FACTSs) can be considered as one of the practical and effective solutions. In this paper, a thyristor-controlled series compensator(TCSC), which is one series type of the FACTS family, is used to augment the overall dynamic performance of a multi-area multi-source interconnected power system. To this end, we have used a hierarchical adaptive neuro-fuzzy inference system controller-TCSC(HANFISC-TCSC) to abate the two important issues in multi-area interconnected power systems, i.e., low-frequency oscillations and tie-line power exchange deviations. For this purpose, a multi-objective optimization technique is inevitable. Multi-objective particle swarm optimization(MOPSO) has been chosen for this optimization problem, owing to its high performance in untangling non-linear objectives. The efficiency of the suggested HANFISC-TCSC has been precisely evaluated and compared with that of the conventional MOPSO-TCSC in two different multi-area interconnected power systems, i.e., two-area hydro-thermal-diesel and three-area hydro-thermal power systems. The simulation results obtained from both power systems have transparently certified the high performance of HANFISC-TCSC compared to the conventional MOPSO-TCSC.展开更多
The large-scale popularization of electric vehicles(EVs)brings the potential for grid frequency regulation.Considering the characteristics of fast response and adjustment of EVs,two control strategies of automatic gen...The large-scale popularization of electric vehicles(EVs)brings the potential for grid frequency regulation.Considering the characteristics of fast response and adjustment of EVs,two control strategies of automatic generation control(AGC)with EVs are proposed responding to two high frequency regulating signals extracted from area control error(ACE)and area regulation requirement(ARR)by a digital filter,respectively.In order to dispatch regulation task to EVs,the capacity of regulation is calculated based on maximum V2G power and the present V2G power of EVs.Finally,simulations based on a two-area interconnected power system show that the proposed approaches can significantly suppress frequency deviation and reduce the active power output of traditional generation units.展开更多
As synchronous generators(SGs)are gradually displaced by renewable energy sources(RESs),the frequency stability of power systems deteriorates because RESs,represented by utility-scale solar and wind power sources,do n...As synchronous generators(SGs)are gradually displaced by renewable energy sources(RESs),the frequency stability of power systems deteriorates because RESs,represented by utility-scale solar and wind power sources,do not provide the inertial response,primary frequency response,secondary frequency response,and tertiary frequency regulation.As a result,the remaining SGs may not be sufficient to maintain the power balance and frequency stability.The concept and control strategies of virtual synchronous generators(VSGs)enable the inverter-based wind and solar power sources to emulate the outer characteristics of traditional SGs and participate in the active power and frequency control of power systems.This paper focuses on the automatic generation control(AGC)with virtual synchronous renewables(VSRs).First,the VSR strategy that enables the RESs to participate in AGC is introduced.Second,based on the interval representation of uncertainty,the output of RES is transformed into two portions,i.e.,the dispatchable portion and the stochastic portion.In the dispatchable portion,the RESs can participate in AGC jointly with SGs.Accordingly,a security-constrained economic dispatch(SCED)model is built considering the RESs operating in VSR mode.Third,the solution strategy that employs the slack variables to acquire deterministic constraints is introduced.Finally,the proposed SCED model is solved based on the 6-bus and 39-bus systems.The results show that,compared with the maximum power point tracking(MPPT)mode,VSRs can participate in the active power and frequency control jointly with SGs,increase the maximum penetration level of RESs,and decrease the operating cost.展开更多
基金Project(51074051)supported by the National Natural Science Foundation of China
文摘The performance of Smith prediction monitoring automatic gauge control(AGC) system is influenced by model mismatching greatly in strip rolling process. Aiming at this problem, a feedback-assisted iterative learning control strategy, which learned unknown modeling error by using previous control information repeatedly, was introduced into Smith prediction monitoring AGC system. Firstly, conventional Smith predictor and improved Smith predictor with PI-P controller were analyzed. Secondly, on the basis of establishing of feedback-assisted iterative learning control strategy for improved Smith predictor, process control signal update law and control error were deduced, then convergence condition of this strategy was put forward and proved. Finally, after modeling the automatic position control system, the PI-P Smith prediction monitoring AGC system with feedback-assisted iterative learning control was researched through simulation. Simulation results indicate that this system remains stable during model mismatching. The robustness and response of monitoring AGC is improved by development of feedback-assisted iterative learning control strategy for PI-P Smith predictor.
基金The National Natural Science Foundation of China(No. 60974116 )the Research Fund of Aeronautics Science (No.20090869007)Specialized Research Fund for the Doctoral Program of Higher Education (No. 200902861063)
文摘In order to effectively control the working state of the gyroscope in drive mode, the drive characteristics of the micro electromechanical system (MEMS) gyroscope are analyzed in principle. A novel drive circuit for the MEMS gyroscope in digital closed-loop control is proposed, which utilizes a digital phase-locked loop (PLL) in frequency control and an automatic gain control (AGC) method in amplitude control. A digital processing circuit with a field programmable gate array (FPGA) is designed and the experiments are carried out. The results indicate that when the temperature changes, the drive frequency can automatically track the resonant frequency of gyroscope in drive mode and that of the oscillating amplitude holds at a set value. And at room temperature, the relative deviation of the drive frequency is 0.624 ×10^-6 and the oscillating amplitude is 8.0 ×10^-6, which are 0. 094% and 18. 39% of the analog control program, respectively. Therefore, the control solution of the digital PLL in frequency and the AGC in amplitude is feasible.
文摘Essentially, it is significant to supply the consumer with reliable and sufficient power. Since, power quality is measured by the consistency in frequency and power flow between control areas. Thus, in a power system operation and control,automatic generation control(AGC) plays a crucial role. In this paper, multi-area(Five areas: area 1, area 2, area 3, area 4 and area 5) reheat thermal power systems are considered with proportional-integral-derivative(PID) controller as a supplementary controller. Each area in the investigated power system is equipped with appropriate governor unit, turbine with reheater unit, generator and speed regulator unit. The PID controller parameters are optimized by considering nature bio-inspired firefly algorithm(FFA). The experimental results demonstrated the comparison of the proposed system performance(FFA-PID)with optimized PID controller based genetic algorithm(GAPID) and particle swarm optimization(PSO) technique(PSOPID) for the same investigated power system. The results proved the efficiency of employing the integral time absolute error(ITAE) cost function with one percent step load perturbation(1 % SLP) in area 1. The proposed system based FFA achieved the least settling time compared to using the GA or the PSO algorithms, while, it attained good results with respect to the peak overshoot/undershoot. In addition, the FFA performance is improved with the increased number of iterations which outperformed the other optimization algorithms based controller.
基金Supported by the Natural Science Foundation of Jiangsu Province ( BK2010411 ) and the National International Cooperation Project of China-Korea (2011DFA11310).
文摘This paper presents an innovative switched-mode auto gain control (AGC) circuit with internally created reset module for DC-10Mb/s burst-mode unbalanced (BMU) optical data transmission. Conventional AGC circuit is inappropriate for BMU data transmission because it is based on average level detection and requires considerable time to settle on a predefined gain. Therefore, we adopt a fast switched-mode AGC based on peak level detection. After the gain is adjusted, the peak level detectors need to re-detect the peak level of the input signal. Thus, we develop an internally created reset module. This AGC with reset module exhibits a fast operation and achieves an adjusted stable gain within one-bit, avoiding any bit loss up to 10Mb/s data rate. During power-up, the peak level detectors possibly hold an uncertain level resulting in the bit-errors. We propose a power-up reset circuit to solve this problem. Designed in a 0.5μm CMOS technology, the circuit achieves an optical sensitivity of better than -30dBm and a wide dynamic range of over 30dB with a power dissipation of only 30 mW from a 5V supply.
文摘Since wind power has the features of being intermittent and unpredictable, and usually needs transmission over long distances, grid integration of large-scale wind power will exert signif icant influence on power grid planning and construction, and will make a heavy impact on the safe and reliable operation of power systems. To deal with the diff iculties of large scale wind power dispatch, this paper presents a new automatic generation control (AGC) scheme that involves the participation of wind farms. The scheme is based on ultra-short-term wind power forecast. The author establishes a generation output distribution optimization mode for the power system with wind farms and verif ies the feasibility of the scheme by an example.
文摘Conventional techniques to control variations within one plate have been based on preset models and constant automatic position control (APC or pressure feedback automatic gauge control(PAGC).However.because of the rolling force prediction error in the preset models and of the inadequate response speed of dynamic system and of the eccentricity, etc.,the conventional method has not given satisfactory results, the statistics'variations within one plate are in range of 0.25-0.60 mm The authors have developed the techniques to control the variations, which are dynamic intelligent control of hydraulic screwdown system. synchronism control of hydraulic screwdown, eccentricity control method by rotary encoder and the curve of modulus of mill measured automatically, etc., The techniques were fully and successfully industrialized in The Plate Mill of Maanshan Iron and Steel Company and good results that variations are in range of 0.08-0.15min hare been obtained in that mill.
文摘Present day power scenarios demand a high quality uninterrupted power supply and needs environmental issues to be addressed. Both concerns can be dealt with by the introduction of the renewable sources to the existing power system. Thus, automatic generation control(AGC) with diverse renewable sources and a modified-cascaded controller are presented in the paper.Also, a new hybrid scheme of the improved teaching learning based optimization-differential evolution(hITLBO-DE) algorithm is applied for providing optimization of controller parameters. A study of the system with a technique such as TLBO applied to a proportional integral derivative(PID), integral double derivative(IDD) and PIDD is compared to hITLBO-DE tuned cascaded controller with dynamic load change.The suggested methodology has been extensively applied to a 2-area system with a diverse source power system with various operation time non-linearities such as dead-band of, generation rate constraint and reheat thermal units. The multi-area system with reheat thermal plants, hydel plants and a unit of a wind-diesel combination is tested with the cascaded controller scheme with a different controller setting for each area. The variation of the load is taken within 1% to 5% of the connected load and robustness analysis is shown by modifying essential factors simultaneously by± 30%. Finally, the proposed scheme of controller and optimization technique is also tested with a 5-equal area thermal system with non-linearities. The simulation results demonstrate the superiority of the proposed controller and algorithm under a dynamically changing load.
基金supported by the National Natural Science Foundation of China (10974154)the National Innovation Project of China for Undergraduates (101069935)
文摘For anti-jamming and anti-countermeasure techniques of the sonar receiver, the response characteristics of the automatic gain control (AGC) circuit and the survivability of the prime circuit under strong interference are analyzed by simulations and experiments. An AGC simulation model based on the voltage control amplifier VCA810 prototype is proposed. Then static and dynamic simulations are realized with single frequency signal and linear frequency modulated (LFM) signal commonly used in the active sonar. Based on intense sound pulse (ISP) interference experiments, the real-time response characteristics of each module of the receiver are studied to verify the correctness of the model as well as the simulation results. Simulation and experiment results show that, under 252 dB/20 μs ISP interference, the specific sonar receiver will produce sustained cut top oscillation above 30 ms, which may affect the receiver and block the regular sonar signal.
基金Supported by the High Technology Research and Development Programme of China (No. 2003AA31g030).
文摘A 6.25 Gbps SerDes core used in the high signed based on the OIF-CEI-02.0 standard. To speed backplane communication receiver has been decounteract the serious Inter-Syrmbol-Interference (ISI), the core employed a half-rate four-tap decision feedback equalizer (DFE). The equalizer used the Signsign least mean-squared (SS-LMS) algorithm to realize the coefficient adaptation. An automatic gain control (AGC) amplifier with the sign least mean-squared (S-LMS) algorithm has been used to compensate the transmission media loss. To recover the clock signal from the input data serial and provide for the DFE and AGC, a bang-bang clock recovery (BB-CR) is adopted. A third order phase loop loek (PLL) model was proposed to predict characteristics of the BB-CR. The core has been verified by behavioral modeling in MATLAB. The results indicate that the core can meet the specifications of the backplane receiver. The DFE recovered data over a 34" FR-4 backplane has a peak-to-peak jitter of 17 ps, a horizontal eye opening of 0.87 UI, and a vertical eye opening of 500 mVpp.
基金Supported by the National Science and Technology Major Project of the Ministry of Science and Technology of China(No.2012ZX03004008)
文摘This paper presented an automatic gain control (AGC) circuit suitable for FM/cw ladar. The proposed architecture was based on two-stage variable gain amplifier (VGA) chain with a novel DC offset canceller circuit, which contained an improved Gilbert cell and a Gm-C feedback loop. To keep the VGA with a linearity in dB characteristic, an improved exponential gain control circuit was introduced. The AGC was implemented in 0.18 gm standard CMOS process. Simulation and measurement results verified that its gain ranged from -20 dB to 30 dB, and band- width ranged from 100 kHz to 10 MHz. Its power consumption was 19.8 mW under a voltage supply of 3.3 V.
文摘Automatic gauge control(AGC in the article)is the key technology of product thickness accuracy and flatness quality in modern cold rolling mill.Most traditional AGC control algorithms need stable external system conditions and hard to stabilize under complex interference that meets coverage requirements.This paper presents a new anti-interference strategy for AGC control of 20-Hi cold reversing mill.The proposed algorithm introduces a united dynamic weights algorithm of feed forward-mass flow to avoid the complex interference problem in AGC control,the relevant control strategy is provided to eliminate the adverse effects.At the same time,the D-value between feed forward-mass flow pre-computation and thickness measurement deviation is dynamic compared,the final gap position regulation is calculated by developing a set of united dynamic weights between feed forward control and mass flow control.Finally,the output of controllers is sent to actuator though a constant rate smoothing.The proposed strategy is compared with conventional AGC control on Experimental platform and project application,the results show that the proposed strategy is more stable than comparison method and majority of system uncertainty produced by mentioned interference is significantly eliminated.
基金supported by the National Natural Science Foundation of China(Grant No.61401026)the National High Technology Research and Development Program of China(Grant No.2014AA1070)
文摘An appropriate acquisition configuration in terms of signal quality can optimize the acquisition performance. In view of this, a new approach of acquisition assisted by the control voltage of automatic gain control(AGC) is proposed. This approach judges the signal power according to the AGC control voltage and switches the working modes correspondingly and adaptively. Non-coherent accumulation times and the detection threshold are reconfigured according to the working mode. Theoretical derivation and verification by simulation in typical situations are provided, and the algorithm is shown to be superior in terms of the mean acquisition time, especially in strong signal scenarios compared with the conventional algorithm.
基金supported in part by the National Natural Science Foundation of China (Nos.61428301,61433004 and 61627809)
文摘With an increasing penetration of wind power in the modern electrical grid, the increasing replacement of large conventional synchronous generators by wind power plants will potentially result in deteriorated frequency regulation performance due to the reduced system inertia and primary frequency response. A series of challenging issues arise from the aspects of power system planning,operation, control and protection. Therefore, it is valuable to develop variable speed wind turbines(VSWTs) equipped with frequency regulation capabilities that allow them to effectively participate in addressing severe frequency contingencies. This paper provides a comprehensive surveyon frequency regulation methods for VSWTs. It fully describes the concepts, principles and control strategies of prevailing frequency controls of VSWTs, including future development trends. It concludes with a performance comparison of frequency regulation by the four main types of wind power plants.
基金This work is supported in part by Major State Basic Research Development Program of China(No.2012CB215206)National Natural Science Foundation of China(No.51107061).
文摘The high penetration of wind energy sources in power systems has substantially increased the demand for faster-ramping thermal units participating in the frequency regulation service.To fulfill the automatic generation control(AGC)and compensate the influence of wind power fluctuations simultaneously,ramping capacity should be considered in the dispatch model of thermals.Meanwhile,conventional methods in this area do not take the impact of transmission loss into the dispatch model,or rely on offline network model and parameters,failing to reflect the real relationships between the wind farms and thermal generators.This paper proposes an online approach for AGC dispatch units considering the above issues.Firstly,the power loss sensitivity is online identified using recursive least square method based on the real-time data of phasor measurement units.It sets up power balance constraint and results in a more accurate dispatch model.Then,an improved multi-objective optimization model of dispatch is proposed and a connection is established between the thermal units with fast ramping capacity and the wind farms with rapid fluctuations.Genetic algorithm is used to solve the dispatch model.The proposed method is compared with conventional methods in simulation case in the IEEE 30-bus system.Finally,simulation results verify the validity and the feasibility of identification method and optimization model.
文摘Communication plays a vital role in incorporating smartness into the interconnected power system.However,historical records prove that the data transfer has always been vulnerable to cyber-attacks.Unless these cyber-attacks are identified and cordoned off,they may lead to black-out and result in national security issues.This paper proposes an optimal two-stage Kalman filter(OTS-KF)for simultaneous state and cyber-attack estimation in automatic generation control(AGC)system.Biases/cyber-attacks are modeled as unknown inputs in the AGC dynamics.Five types of cyber-attacks,i.e.,false data injection(FDI),data replay attack,denial of service(DoS),scaling,and ramp attacks,are injected into the measurements and estimated using OTS-KF.As the load variations of each area are seldom available,OTS-KF is reformulated to estimate the states and outliers along with the load variations of the system.The proposed technique is validated on the benchmark two-area,three-area,and five-area power system models.The simulation results under various test conditions demonstrate the efficacy of the proposed filter.
基金a part of Ph.D.project funded by Sino-Danish centre for education and research(SDC)
文摘Highly wind power integrated power system requires continuous active power regulation to tackle the power imbalances resulting from the wind power forecast errors. The active power balance is maintained in real-time with the automatic generation control and also from the control room, where regulating power bids are activated manually. In this article, an algorithm is developed to simulate the activation of regulating power bids, as performed in the control room, during power imbalance between generation and load demand. In addition, the active power balance is also controlled through automatic generation control, where coordinated control strategy between combined heat and power plants and wind power plant enhances the secure power system operation. The developed algorithm emulating the control room response,to deal with real-time power imbalance, is applied and investigated on the future Danish power system model. The power system model takes the hour-ahead regulating power plan from power balancing model and the generation and power exchange capacities for the year 2020 into account.The real-time impact of power balancing in a highly wind power integrated power system is assessed and discussed by means of simulations for different possible scenarios.
文摘In this paper, a fractional order proportional integral derivative (FOPID) controller for multiarea automatic generation control (AGC) scheme has been designed. FOPID controller has five parameters and provides two additional degrees of flexibility in comparison to a proportional integral derivative (PID) controller. The optimal values of parameters of FOPID controller have been determined using Big Bang Big Crunch (BBBC) search algorithm. The designed controller regulates real power output of generators to achieve the best dynamic response of frequency and tie-line power on a load perturbation. The complete scheme for designing of the controllers has been developed and demonstrated on multiarea deregulated power system. The performance of the designed FOPID controllers has been compared with the optimally tuned PID controllers. It is observed from the results that the FOPID controller shows a considerable improvement in the performance as compared to the conventional PID controller.
文摘Suppression of the dynamic oscillations of tie-line power exchanges and frequency in the affected interconnected power systems due to loading-condition changes has been assigned as a prominent duty of automatic generation control(AGC). To alleviate the system oscillation resulting from such load changes, implementation of flexible AC transmission systems(FACTSs) can be considered as one of the practical and effective solutions. In this paper, a thyristor-controlled series compensator(TCSC), which is one series type of the FACTS family, is used to augment the overall dynamic performance of a multi-area multi-source interconnected power system. To this end, we have used a hierarchical adaptive neuro-fuzzy inference system controller-TCSC(HANFISC-TCSC) to abate the two important issues in multi-area interconnected power systems, i.e., low-frequency oscillations and tie-line power exchange deviations. For this purpose, a multi-objective optimization technique is inevitable. Multi-objective particle swarm optimization(MOPSO) has been chosen for this optimization problem, owing to its high performance in untangling non-linear objectives. The efficiency of the suggested HANFISC-TCSC has been precisely evaluated and compared with that of the conventional MOPSO-TCSC in two different multi-area interconnected power systems, i.e., two-area hydro-thermal-diesel and three-area hydro-thermal power systems. The simulation results obtained from both power systems have transparently certified the high performance of HANFISC-TCSC compared to the conventional MOPSO-TCSC.
基金This work was supported by Sino-US international Science and Technology Cooperation Project(Grant No.2016YFE0105300).
文摘The large-scale popularization of electric vehicles(EVs)brings the potential for grid frequency regulation.Considering the characteristics of fast response and adjustment of EVs,two control strategies of automatic generation control(AGC)with EVs are proposed responding to two high frequency regulating signals extracted from area control error(ACE)and area regulation requirement(ARR)by a digital filter,respectively.In order to dispatch regulation task to EVs,the capacity of regulation is calculated based on maximum V2G power and the present V2G power of EVs.Finally,simulations based on a two-area interconnected power system show that the proposed approaches can significantly suppress frequency deviation and reduce the active power output of traditional generation units.
基金supported by the Research and Application of Key Technologies of Flexible Power Supply System Under Various Emergency Scenarios(No.5442PD210001)。
文摘As synchronous generators(SGs)are gradually displaced by renewable energy sources(RESs),the frequency stability of power systems deteriorates because RESs,represented by utility-scale solar and wind power sources,do not provide the inertial response,primary frequency response,secondary frequency response,and tertiary frequency regulation.As a result,the remaining SGs may not be sufficient to maintain the power balance and frequency stability.The concept and control strategies of virtual synchronous generators(VSGs)enable the inverter-based wind and solar power sources to emulate the outer characteristics of traditional SGs and participate in the active power and frequency control of power systems.This paper focuses on the automatic generation control(AGC)with virtual synchronous renewables(VSRs).First,the VSR strategy that enables the RESs to participate in AGC is introduced.Second,based on the interval representation of uncertainty,the output of RES is transformed into two portions,i.e.,the dispatchable portion and the stochastic portion.In the dispatchable portion,the RESs can participate in AGC jointly with SGs.Accordingly,a security-constrained economic dispatch(SCED)model is built considering the RESs operating in VSR mode.Third,the solution strategy that employs the slack variables to acquire deterministic constraints is introduced.Finally,the proposed SCED model is solved based on the 6-bus and 39-bus systems.The results show that,compared with the maximum power point tracking(MPPT)mode,VSRs can participate in the active power and frequency control jointly with SGs,increase the maximum penetration level of RESs,and decrease the operating cost.