Uniformity of dosage units[1]is one of the most commonly employed compendial tests to evaluate the dosage units.In the test,the acceptance value(AV)is the key statistics-based acceptance parameter with the limit of no...Uniformity of dosage units[1]is one of the most commonly employed compendial tests to evaluate the dosage units.In the test,the acceptance value(AV)is the key statistics-based acceptance parameter with the limit of not more than 15 to measure the uniformity degree of the dosage units in terms of content uniformity or weight variation as applicable.With quality assurance(QA)principle,there should be some kinds of predetermined acceptance limits,like Bergum method introduced by James S.Bergum in 1990[2]and 2007[3]and recently recognized by ASTM 2709[4]and ASTM 2810[5]to ensure that the AV results for any future quality control(QC)samples will not exceed the compendial limit(NMT 15).展开更多
Minced pork paste was mixed with cooked rice and noodle resulted in very popular traditional gourmet meal in Taiwan. The 100 ℃, 4 h was normally cooking condition for commercial business. However, the pressure cooker...Minced pork paste was mixed with cooked rice and noodle resulted in very popular traditional gourmet meal in Taiwan. The 100 ℃, 4 h was normally cooking condition for commercial business. However, the pressure cooker with higher cooking temperature (106 ℃, 116 ℃ and 121 ℃) and different cooking time were under studied in order to improving efficiency, quality and even cost down. The samples of neck pork substitute, cooking at 106℃, 100 rain; 116℃, 75 min; 121 ℃, 45 min with different pressure were perfomed the result as well as traditional 20% fat in ordinary formulation and cooking at 100℃ for 4 h. During storage, the products were taste acceptable for 4 weeks at 4 ℃, 4 months at - 18 ℃ and better than 1 day at 25 ℃ storage.展开更多
文摘Uniformity of dosage units[1]is one of the most commonly employed compendial tests to evaluate the dosage units.In the test,the acceptance value(AV)is the key statistics-based acceptance parameter with the limit of not more than 15 to measure the uniformity degree of the dosage units in terms of content uniformity or weight variation as applicable.With quality assurance(QA)principle,there should be some kinds of predetermined acceptance limits,like Bergum method introduced by James S.Bergum in 1990[2]and 2007[3]and recently recognized by ASTM 2709[4]and ASTM 2810[5]to ensure that the AV results for any future quality control(QC)samples will not exceed the compendial limit(NMT 15).
文摘Minced pork paste was mixed with cooked rice and noodle resulted in very popular traditional gourmet meal in Taiwan. The 100 ℃, 4 h was normally cooking condition for commercial business. However, the pressure cooker with higher cooking temperature (106 ℃, 116 ℃ and 121 ℃) and different cooking time were under studied in order to improving efficiency, quality and even cost down. The samples of neck pork substitute, cooking at 106℃, 100 rain; 116℃, 75 min; 121 ℃, 45 min with different pressure were perfomed the result as well as traditional 20% fat in ordinary formulation and cooking at 100℃ for 4 h. During storage, the products were taste acceptable for 4 weeks at 4 ℃, 4 months at - 18 ℃ and better than 1 day at 25 ℃ storage.