A new reflection approach for field distribution measurement of ultrasonic transducers was investigated. Instead of a point-like reflection target (rigid sphere) or thin wires (line-like targets), a line response ...A new reflection approach for field distribution measurement of ultrasonic transducers was investigated. Instead of a point-like reflection target (rigid sphere) or thin wires (line-like targets), a line response function of experimental knife-edge distribution combined with the inverse Abel transforms was used to estimate the lateral beam distributions of ultrasonic transducers. The measurement steps were as follows:① A knife-edge was scanned perpendicularly to acoustic beam axis of the transducer using an ultrasonic C-scan system to obtain its ultrasonic image line response function, ② the transverse beam distribution was solved by the inverse Abel transforms, and ③ experiments were performed to obtain the lateral beam profiles of two transducers, with and without focus, and the results were compared with those from a hydrophone. The results showed that this method was effective for ultrasonic field measurement and could be as a substitute for hydrophone in most cases.展开更多
A 3D temperature field reconstruction method using the colored background oriented schlieren(CBOS)method is proposed to address image blurring due to the different refractive index of the multi-wavelength light and si...A 3D temperature field reconstruction method using the colored background oriented schlieren(CBOS)method is proposed to address image blurring due to the different refractive index of the multi-wavelength light and significant errors produced when the traditional background oriented schlieren(BOS)method is applied to high-temperature gas.First,the traditional method is employed to reconstruct the non-uniform 3D temperature field.Second,the CBOS method is applied to correct the distortion.Then,by analyzing the correlation coefficient among different color points of the colored background pattern,the non-uniform temperature field is reconstructed much more accurately.Finally,the experimental results are verified by applying the Runge-Kutta ray-tracing method and the thermocouple contact measurement method.The maximum average temperature error of the CBOS-reconstructed temperature field is 12.92°C,compared with the thermocouples.Therefore,an accurate three-dimensional reconstruction of the temperature field can be achieved by the proposed method effectively.展开更多
The author studies the oscillating multipliers on Riemannian symmetric spaceSL(3,IH)/Sp(3).The results are analogous to that for Riemannian symmetric spaces of rank one and of complex type.
文摘A new reflection approach for field distribution measurement of ultrasonic transducers was investigated. Instead of a point-like reflection target (rigid sphere) or thin wires (line-like targets), a line response function of experimental knife-edge distribution combined with the inverse Abel transforms was used to estimate the lateral beam distributions of ultrasonic transducers. The measurement steps were as follows:① A knife-edge was scanned perpendicularly to acoustic beam axis of the transducer using an ultrasonic C-scan system to obtain its ultrasonic image line response function, ② the transverse beam distribution was solved by the inverse Abel transforms, and ③ experiments were performed to obtain the lateral beam profiles of two transducers, with and without focus, and the results were compared with those from a hydrophone. The results showed that this method was effective for ultrasonic field measurement and could be as a substitute for hydrophone in most cases.
基金Supported by the National Natural Science Foundation of China(52005500)Foundation of Tianjin Educational Committee(2018KJ242)Basic Science-Research Funds of National University(3122019088)。
文摘A 3D temperature field reconstruction method using the colored background oriented schlieren(CBOS)method is proposed to address image blurring due to the different refractive index of the multi-wavelength light and significant errors produced when the traditional background oriented schlieren(BOS)method is applied to high-temperature gas.First,the traditional method is employed to reconstruct the non-uniform 3D temperature field.Second,the CBOS method is applied to correct the distortion.Then,by analyzing the correlation coefficient among different color points of the colored background pattern,the non-uniform temperature field is reconstructed much more accurately.Finally,the experimental results are verified by applying the Runge-Kutta ray-tracing method and the thermocouple contact measurement method.The maximum average temperature error of the CBOS-reconstructed temperature field is 12.92°C,compared with the thermocouples.Therefore,an accurate three-dimensional reconstruction of the temperature field can be achieved by the proposed method effectively.
文摘The author studies the oscillating multipliers on Riemannian symmetric spaceSL(3,IH)/Sp(3).The results are analogous to that for Riemannian symmetric spaces of rank one and of complex type.