期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Surgical Fixation of Fourth and Fifth Metacarpal Shaft Fractures with Flexible Intramedullary Absorbable Rods: Early Clinical Outcomes and Implications 被引量:3
1
作者 Ge Xiong Zi-Run Xiao +2 位作者 Shi-Gong GUO Wei Zheng Lu-Fei Dai 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第21期2851-2855,共5页
Background: To avoid the irritation of tendons and soft tissues as well as hardware-related problems, we designed an intramedullary fixation with bioabsorbable rods for the treatment of the metacarpal shaft fractures... Background: To avoid the irritation of tendons and soft tissues as well as hardware-related problems, we designed an intramedullary fixation with bioabsorbable rods for the treatment of the metacarpal shaft fractures. Methods: Five patients with nine shaft fractures of the fourth and fifth metacarpi were treated with intramedullary absorbable implants and followed up with an average of 4.2 months postoperatively. Results: At final follow-up, all patients achieved fracture union with no signs of inflammatory or subcutaneous effusion. There was no shortening, angulatory, or rotatory deformity. There was almost full active extension range of motion (ROM) of the metacarpophalangeal joints while the active flexion ROM of these joints was 80.7 ± 9.6°. hand was 94.0 ± 9.6%. X-rays showed that the arch of the second Compared with the contralateral hand, the grip strength of the injured to fifth metacarpal heads was smooth. There were no intramedullary lytic changes and soft tissue swellings. Conclusion: The intramedullary absorbable implants are a safe, simple, and practical treatment for fourth and filth metacarpal fractures with good early clinical outcomes and no significant complications. 展开更多
关键词 absorbable Implant Follow-up: Intramedullary Fixation Metacarpal Fracture
原文传递
Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up 被引量:2
2
作者 Barzi Gareb Nico Bvan Bakelen +6 位作者 Leon Driessen Pieter Buma Jeroen Kuipers Dirk W.Grijpma Arjan Vissink Ruud R.M.Bos Baucke van Minnen 《Bioactive Materials》 SCIE 2022年第11期439-456,共18页
pplying biodegradable osteosyntheses avoids the disadvantages of titanium osteosyntheses. However, foreign-body reactions remain a major concern and evidence of complete resorption is lacking. This study compared the ... pplying biodegradable osteosyntheses avoids the disadvantages of titanium osteosyntheses. However, foreign-body reactions remain a major concern and evidence of complete resorption is lacking. This study compared the physico-chemical properties, histological response and radiographs of four copolymeric biodegradable osteo-synthesis systems in a goat model with 48-months follow-up. The systems were implanted subperiosteally in both tibia and radius of 12 Dutch White goats. The BioSorb FX [poly(70LLA-co-30DLLA)], Inion CPS [poly([70–78.5] LLA-co-[16–24]DLLA-co-4TMC)], SonicWeld Rx [poly(DLLA)], LactoSorb [poly(82LLA-co-18GA)] systems and a negative control were randomly implanted in each extremity. Samples were assessed at 6-, 12-, 18-, 24-, 36-, and 48-month follow-up. Surface topography was performed using scanning electron microscopy (SEM). Differential scanning calorimetry and gel permeation chromatography were performed on initial and explanted samples. Histological sections were systematically assessed by two blinded researchers using (polarized) light microscopy, SEM and energy-dispersive X-ray analysis. The SonicWeld Rx system was amorphous while the others were semi-crystalline. Foreign-body reactions were not observed during the complete follow-up. The SonicWeld Rx and LactoSorb systems reached bone percentages of negative controls after 18 months while the BioSorb Fx and Inion CPS systems reached these levels after 36 months. The SonicWeld Rx system showed the most predictable degradation profile. All the biodegradable systems were safe to use and well-tolerated (i.e., complete implant replacement by bone, no clinical or histological foreign body reactions, no [sterile] abscess formation, no re-interventions needed), but nanoscale residual polymeric fragments were observed at every system’s assessment. 展开更多
关键词 Biocompatible materials absorbable implants Polymers Orthopaedic fixation devices Reconstructive surgical procedures Fracture fixation
原文传递
上一页 1 下一页 到第