期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Management of geriatric acetabular fractures:Contemporary treatment strategies
1
作者 Theodoros Tosounidis Byron Chalidis 《World Journal of Clinical Cases》 SCIE 2024年第13期2151-2156,共6页
Acetabular fractures in the geriatric population are typically low-energy fractures resulting from a fall from standing height.Compromised bone quality in the elderly,as well as this population’s concomitant medical ... Acetabular fractures in the geriatric population are typically low-energy fractures resulting from a fall from standing height.Compromised bone quality in the elderly,as well as this population’s concomitant medical comorbidities,render the management of such fractures challenging and controversial.Non-operative management remains the mainstay of treatment,although such a choice is associated with numerous and serious complications related to both the hip joint as well as the general condition of the patient.On the other hand,operatively treating acetabular fractures(e.g.,with osteosynthesis or total hip arthroplasty)is gaining popularity.Osteosynthesis can be performed with open reduction and internal fixation or with minimally invasive techniques.Total hip arthroplasty could be performed either in the acute phase combined with osteosynthesis or as a delayed procedure after a period of non-operative management or after failed osteosynthesis of the acetabulum.Regardless of the implemented treatment,orthogeriatric co-management is considered extremely crucial,and it is currently one of the pillars of a successful outcome after an acetabular fracture. 展开更多
关键词 acetabular fractures Geriatric fractures Fracture fixation Total hip arthroplasty MORTALITY MORBIDITY
下载PDF
The analysis of relevant risk factors of traumatic arthritis resulting from the surgery of acetabular fractures
2
作者 黄金城 《外科研究与新技术》 2011年第2期116-116,共1页
Objective To explore the relevant risk factors of tramatic arthritis resulting from the surgery of acetabular fractures. Methods From January 2000 to January 2009,88 patients aged from 20 to 60 years old with acetabul... Objective To explore the relevant risk factors of tramatic arthritis resulting from the surgery of acetabular fractures. Methods From January 2000 to January 2009,88 patients aged from 20 to 60 years old with acetabular fractures 展开更多
关键词 The analysis of relevant risk factors of traumatic arthritis resulting from the surgery of acetabular fractures
下载PDF
Three-dimensional printing combined with open reduction and internal fixation versus open reduction and internal fixation in the treatment of acetabular fractures:A systematic review and meta-analysis 被引量:3
3
作者 Dong-Peng Tu Yi-Kang Yu +3 位作者 Zhen Liu Wen-Kai Zhang Xin Fan Chao Xu 《Chinese Journal of Traumatology》 CAS CSCD 2021年第3期159-168,共10页
Purpose:This meta-analysis compared the clinical outcome of three-dimensional(3D)printing combined with open reduction and internal fixation(ORIF)to traditional ORIF in the treatment of acetabular fractures.Methods:We... Purpose:This meta-analysis compared the clinical outcome of three-dimensional(3D)printing combined with open reduction and internal fixation(ORIF)to traditional ORIF in the treatment of acetabular fractures.Methods:We searched the Cochrane Library,PubMed,Embase,VIP database,CNKI,and Wanfang data-base with keywords"acetabular fracture","3D printing","three-dimensional printing","open reduction and internal fixation","Acetabulum","Acetabula"from January 2000 to March 2020.Two reviewers independently selected articles,extracted data,assessed the quality evidence and risk bias of included trials using the Cochrane Collaboration’s tools and/or Newcastle-Ottawa scale.When the two analysts had different opinions,they would ask the third analyst for opinion.Randomized controlled trials or retrospective comparative studies of 3D printing combined with ORIF(3D printing group)versus traditional ORIF(conventional group)in the treatment of acetabular fractures were selected.The data of operation time,intraoperative blood loss,intraoperative fluoroscopy times,incidence of complications,excellent and good rate of Matta score for reduction,and excellent and good rate of hip function score were extracted.Stata14.0 statistical software was used for data analysis.Results:Altogether 9 articles were selected,including 5 randomized controlled trials and 4 retrospective studies.A total of 467 patients were analyzed,250 in the conventional group,and 217 in the 3D printing group.The operation time in the 3D printing group was less than that in the conventional group and the difference was statistically significant(standardized mean difference(SMD)=-1.19,95%CI:-1.55 to-0.82,p<0.05).The intraoperative bleeding volume of the 3D printing group was significantly lower than that of the conventional group(SMD=-1.08,95%CI:-1.65 to-0.51,p<0.05).The fluoroscopy times were less in the 3D printing group than in the conventional group and the difference was statistically significant(SMD=-1.64,95%CI:-2.35 to-0.93,p<0.05).The total incidence of complications in the 3D printing group was significantly lower than that in the conventional group(OR=0.43,95%CI:0.24-0.79,p<0.05).There was no significant difference in the excellent and good rate of Matta score for reduction between the two groups(OR=0.60,95%CI:0.34-1.06,p>0.05).There was no significant difference in the excellent and good rate of hip function score at the end of postoperative follow-up between the two groups(OR=0.84,95%CI:0.46-1.56,p>0.05),but the follow-up time varies from 6 months to 40 months.Conclusion:Compared with traditional ORIF,3D printing combined with ORIF has certain advantages in terms that 3D printing not only helps surgeons to understand acetabular fractures more intuitively,but also effectively reduces operation time,intraoperative blood loss,intraoperative fluoroscopy times,and postoperative complications.However,there were no significant differences in the excellent and good rate of Matta score for reduction and the excellent and good rate of hip function score at the end of follow-up. 展开更多
关键词 Three-dimensional printing acetabular fractures Open reduction and internal fixation META-ANALYSIS
原文传递
A novel anatomical self-locking plate fixation for both-column acetabular fractures 被引量:1
4
作者 Ming Li Shuai-Yi Wang Jing-Wei Xiao 《Chinese Journal of Traumatology》 CAS CSCD 2022年第6期345-352,共8页
Purpose:To compare the stability of the posterior anatomic self-locking plate(PASP)with two types of popular reconstruction plate fixation,i.e.double reconstruction plate(DRP)and cross reconstruction plate(CRP),and to... Purpose:To compare the stability of the posterior anatomic self-locking plate(PASP)with two types of popular reconstruction plate fixation,i.e.double reconstruction plate(DRP)and cross reconstruction plate(CRP),and to explore the influence of sitting and turning right/left on implants.Methods:PASP,DRP and CRP were assembled on a finite element model of both-column fractures of the left acetabulum.A load of 600 N and a torque of 8 N·m were loaded on the S1 vertebral body to detect the change of stress and displacement when sitting and turning right/left.Results:The peak stress and displacement of the three kinds of fixation methods under all loading conditions were CRP>DRP>PASP.The peak stress and displacement of PASP are 313.5 MPa and 1.15 mm respectively when turning right;and the minimal was 234.0 Mpa and 0.619 mm when turning left.Conclusion:PASP can provide higher stability than DRP and CRP for both-column acetabular fractures.The rational movement after posterior DRP and PASP fixation for acetabular fracture is to turn to the ipsilateral side,which can avoid implant failure. 展开更多
关键词 acetabular fractures Internal fixation Posterior anatomic self-locking plate(PASP) BIOMECHANICS Stability
原文传递
Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study 被引量:1
5
作者 De-Yong Huang Liang Zhang +3 位作者 Yi-Xin Zhou Chun-YuZhang Hui Xu Yong Huang 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第8期903-908,共6页
Background:Porous-coated cups have been widely used in acetabular reconstruction after failed treatment of acetabular fractures,and good results have been reported with the use of these cups;however,the durability an... Background:Porous-coated cups have been widely used in acetabular reconstruction after failed treatment of acetabular fractures,and good results have been reported with the use of these cups;however,the durability and functionality of modular trabecular metal (TM) acetabular components in acetabular reconstruction after failed treatment of acetabular fractures remain unclear.This study aimed to examine the radiographic and clinical outcomes associated with the use of modular TM acetabular components for failed treatment of acetabular fractures to assess the durability and functionality of these components in acetabular reconstruction after failed treatment of acetabular fractures.Methods:A total of 41 patients (41 hips) underwent total hip arthroplasty (THA) using modular TM acetabular components for failed treatment of acetabular fractures at our hospital between January 2007 and December 2012.Among these patients,two were lost to follow-up.Therefore,39 patients (39 hips) were finally included in this study.The Harris hip score before and after the surgery,satisfaction level of the patients,and radiographic results were assessed.Results:The mean Harris hip score increased from 34 (range,8-52) before surgery to 91 (range,22-100) at the latest follow-up examination (P 〈 0.001).The results were excellent for 28 hips,good for six,fair for three,and poor for two.Among the 39 patients,25 (64%) and 10 (26%) were very satisfied and somewhat satisfied,respectively.All cups were found to be fully incorporated,and no evidence of cup migration or periacetabular osteolysis was noted.Conclusions:Despite the technically demanding nature of the procedure,THA using modular TM acetabular components showed good durability and functionality and may be an effective reconstruction option for failed treatment of acetabular fractures. 展开更多
关键词 acetabular Fracture Trabecular Metal Total Hip Arthroplasty
原文传递
Open Reduction by Fenestration to the Ilium for Central Acetabular Depression Fractures: A Case Report and Operative Technique
6
作者 Kazushige Yoshida Masaaki Maruyama +2 位作者 Kentaro Kasama Hiroyuki Hashidate Kazumi Kitagawa 《Open Journal of Orthopedics》 2016年第8期221-226,共6页
Aim: The aim was to report a fenestration technique for gap reduction of acetabular depression fractures. Case presentation: A 76-year-old man suffered from severe left leg pain. The computed tomography scanning showe... Aim: The aim was to report a fenestration technique for gap reduction of acetabular depression fractures. Case presentation: A 76-year-old man suffered from severe left leg pain. The computed tomography scanning showed a displaced acetabular depression fracture, including a third fracture fragment in the center of the acetabular weight-bearing area. We performed a fenestration technique to fenestrate the outer plate of ilium to push down the dislocated fragment of the fracture. The patient was pain-free with good functional outcome of the hip joint at three years after operation. Conclusion: The fenestration technique is useful for displaced acetabular depression fractures. We performed open reduction in this particular case, but the technique may be done less invasively with the use of hip arthroscopy. 展开更多
关键词 Hip Fracture FENESTRATION acetabular Fracture
下载PDF
Computer navigation-assisted minimally invasive percutaneous screw placement for pelvic fractures 被引量:18
7
作者 Tong Yu Xue-Liang Cheng +3 位作者 Yang Qu Rong-Peng Dong Ming-Yang Kang Jian-Wu Zhao 《World Journal of Clinical Cases》 SCIE 2020年第12期2464-2472,共9页
Pelvic fractures are often caused by high-energy injuries and accompanied by hemodynamic instability.Traditional open surgery has a large amount of bleeding,which is not suitable for patients with acute pelvic fractur... Pelvic fractures are often caused by high-energy injuries and accompanied by hemodynamic instability.Traditional open surgery has a large amount of bleeding,which is not suitable for patients with acute pelvic fracture.Navigationguided,percutaneous puncture-screw implantation has gradually become a preferred procedure due to its advantages,which include less trauma,faster recovery times,and less bleeding.However,due to the complexity of pelvic anatomy,doctors often encounter some problems when using navigation to treat pelvic fractures.This article reviews the indications,contraindications,surgical procedures,and related complications of this procedure for the treatment of sacral fractures,sacroiliac joint injuries,pelvic ring injuries,and acetabular fractures.We also analyze the causes of inaccurate screw placement.Percutaneous screw placement under navigational guidance has the advantages of high accuracy,low incidence of complications and small soft-tissue damage,minimal blood loss,short hospital stays,and quick recovery.There is no difference in the incidence of complications between surgeries performed by new doctors and experienced ones.However,computer navigation technology requires extensive training,and attention should be given to avoid complications such as screw misplacement,intestinal injury,and serious blood vessel and nerve injuries caused by navigational drift. 展开更多
关键词 Computer navigation Percutaneous puncture SCREW Pelvic fracture Sacral fracture acetabular fracture Iliac fracture Pubic fracture
下载PDF
Interobserver and intraobserver agreement for Letournel acetabular fracture classification system using 3-dimensional printed solid models 被引量:1
8
作者 Eran Keltz Doron Keshet +3 位作者 Eli Peled Yoav Zvi Doron Norman Yaniv Keren 《World Journal of Orthopedics》 2021年第2期82-93,共12页
BACKGROUND Acetabular fractures pose diagnostic and surgical challenges.They are classified using the Judet-Letournel system,which is based solely on X-ray.However,computed tomography(CT)imaging is now more widely uti... BACKGROUND Acetabular fractures pose diagnostic and surgical challenges.They are classified using the Judet-Letournel system,which is based solely on X-ray.However,computed tomography(CT)imaging is now more widely utilized in diagnosing these injuries.The emergence of 3-dimensional(3-D)printing technology in varying orthopedic fields has provided surgeons a solid model that improves their spatial understanding of complex fractures and ability to plan preoperatively.AIM To evaluate the reliability of the Judet-Letournel classification system of acetabular fractures,when using either CT imaging or 3-D printed models.METHODS Seven patients with acetabular fractures underwent pelvic CT imaging,which was then used to create solid,3-D printed models.Eighteen orthopaedic trauma surgeons responded to questionnaires regarding fracture classification and preferred surgical approach.The same questionnaire was completed using only CT imaging,and two weeks later,using only 3-D printed models.The inter-and intra-observer agreement rates were then analyzed.RESULTS Inter-observer agreement rates based on CT imaging or 3-D printed models were moderate for fracture classification:κ=0.44,κ=0.55,respectively(P<0.001)and fair for preferred surgical approach:κ=0.34,κ=0.29,respectively(P<0.005).Intra-observer agreement rates for fracture classification and preferred surgical approach comparing CT imaging or 3-D printed models were moderate:κ=0.48,κ=0.41,respectively.No significant difference in intra-observer agreement was detected when comparing orthopedic pelvic specialists to general orthopedic traumatologists.CONCLUSION The Judet-Letournel classification demonstrated only moderate rates of agreement.The use of 3-D printed models increased the inter-observer agreement rates with respect to fracture classification,but decreased it with respect to the preferred surgical approach.This study highlights the role of 3-D printed models in acetabular fractures by improving spatial understanding of these complex injuries,thus providing more reliable fracture diagnoses and alternative viewpoints for pre-operative planning. 展开更多
关键词 ACETABULUM Pelvic trauma acetabular fracture Three-dimensional printing Three-dimensional reconstruction Judet-Letournel
下载PDF
Functional Outcomes of Traumatic Complex Acetabulum Fractures with Open Reduction and Internal Fixation: 200 Cases 被引量:3
9
作者 Keykhosro Mardanpour Mahtab Rahbar +2 位作者 Maryam Rahbar Nyosha Mardanpour Sourena Mardanpour 《Open Journal of Orthopedics》 2016年第12期363-377,共15页
Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We ana... Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We analyzed a case series of patients with open reduction and internal fixation (ORIF) for complex acetabular fractures. Two hundred patients (132 men, 68 women) in four age groups including with a mean age of 43.39 ± 6.18 years (range 20 - 59 years) and a mean follow-up of 82.34 ± 12.48 months (range 18 - 109 months) met the inclusion criteria. Functional outcome at final follow-up was graded assessed according to Harris score. Factors affecting were defined. Results: Anatomic reduction was achieved in 192 hips, imperfect in 8 and poor in none. Radiological outcome revealed excellent results in 128 (64%) hips, good in eight, fair in five and none in poor. Harris score were excellent in 139 (69.5%) hips, good in 43 (21.5%) and fair in 18 (9%) and poor in none. The anatomical reduction results had a favorable final functional outcome. (0.003) However, BMI (P Conclusion: Optimal functional and radiological outcomes have been achieved with anatomic postoperative reduction. Also experience of specialist, on time surgery and good recovery lead to receiving excellent functional outcome with at least complications. 展开更多
关键词 Complex acetabular Fracture Internal Fixation Open Reduction OUTCOME
下载PDF
Quadrilateral plate fractures of the acetabulum:Classification,approach,implant therapy and related research progress
10
作者 Xue-Feng Zhou Si-Chao Gu +3 位作者 Wan-Bo Zhu Jia-Zhao Yang Lei Xu Shi-Yuan Fang 《World Journal of Clinical Cases》 SCIE 2022年第2期412-425,共14页
The quadrilateral plate(QP)is an essential structure of the inner wall of the acetabulum,an important weight-bearing joint of the human body,which is often involved in acetabular fractures.The operative exposure,reduc... The quadrilateral plate(QP)is an essential structure of the inner wall of the acetabulum,an important weight-bearing joint of the human body,which is often involved in acetabular fractures.The operative exposure,reduction and fixation of QP fractures have always been the difficulties in orthopedics due to the special morphological structure and anatomical features of the QP.Fortunately,there have been many effective methods and instruments developed for QP exposure,reduction and fixation by virtue of the combined efforts of numerous orthopedists.At the same time,each method presents with its own advantages and disadvantages,resulting in different prognoses.It is necessary to have a thorough understanding of the anatomy,radiology and fixation techniques of the QP in terms of patient prognosis optimization.In this paper,the anatomical features,definition and classification of QP,operative approach selection,implant internal fixation methods and efficacy were reviewed. 展开更多
关键词 acetabular fracture Quadrilateral plate Fracture classification Operative approach IMPLANT Internal fixation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部