期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Acoustic radiation force impulse predicts long-term outcomes in a large-scale cohort:High liver cancer,low comorbidity in hepatitis B virus 被引量:1
1
作者 Jennifer Tai Adam P Harrison +7 位作者 Hui-Ming Chen Chiu-Yi Hsu Tse-Hwa Hsu Cheng-Jen Chen Wen-Juei Jeng Ming-Ling Chang Le Lu Dar-In Tai 《World Journal of Gastroenterology》 SCIE CAS 2023年第14期2188-2201,共14页
BACKGROUND Acoustic radiation force impulse(ARFI)is used to measure liver fibrosis and predict outcomes.The performance of elastography in assessment of fibrosis is poorer in hepatitis B virus(HBV)than in other etiolo... BACKGROUND Acoustic radiation force impulse(ARFI)is used to measure liver fibrosis and predict outcomes.The performance of elastography in assessment of fibrosis is poorer in hepatitis B virus(HBV)than in other etiologies of chronic liver disease.AIM To evaluate the performance of ARFI in long-term outcome prediction among different etiologies of chronic liver disease.METHODS Consecutive patients who received an ARFI study between 2011 and 2018 were enrolled.After excluding dual infection,alcoholism,autoimmune hepatitis,and others with incomplete data,this retrospective cohort were divided into hepatitis B(HBV,n=1064),hepatitis C(HCV,n=507),and non-HBV,non-HCV(NBNC,n=391)groups.The indexed cases were linked to cancer registration(1987-2020)and national mortality databases.The differences in morbidity and mortality among the groups were analyzed.RESULTS At the enrollment,the HBV group showed more males(77.5%),a higher prevalence of prediagnosed hepatocellular carcinoma(HCC),and a lower prevalence of comorbidities than the other groups(P<0.001).The HCV group was older and had a lower platelet count and higher ARFI score than the other groups(P<0.001).The NBNC group showed a higher body mass index and platelet count,a higher prevalence of pre-diagnosed non-HCC cancers(P<0.001),especially breast cancer,and a lower prevalence of cirrhosis.Male gender,ARFI score,and HBV were independent predictors of HCC.The 5-year risk of HCC was 5.9%and 9.8%for those ARFI-graded with severe fibrosis and cirrhosis.ARFI alone had an area under the receiver operating characteristic curve(AUROC)of 0.742 for prediction of HCC in 5 years.AUROC increased to 0.828 after adding etiology,gender,age,and platelet score.No difference was found in mortality rate among the groups.CONCLUSION The HBV group showed a higher prevalence of HCC but lower comorbidity that made mortality similar among the groups.Those patients with ARFI-graded severe fibrosis or cirrhosis should receive regular surveillance. 展开更多
关键词 Non-alcoholic fatty liver disease Hepatitis B Hepatocellular carcinoma acoustic radiation force impulse MORTALITY COMORBIDITY
下载PDF
Application of acoustic radiation force impulse imaging for the evaluation of focal liver lesion elasticity 被引量:11
2
作者 Ping Zhang Ping Zhou +3 位作者 Shuang-Ming Tian Ying Qian Jin Deng Lu Zhang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2013年第2期165-170,共6页
BACKGROUND: Acoustic radiation force impulse (ARFI) imaging is a new elastography method for the evaluation of tissue stiffness. This study aims to evaluate the performance of ARFI in noninvasive assessment of the tis... BACKGROUND: Acoustic radiation force impulse (ARFI) imaging is a new elastography method for the evaluation of tissue stiffness. This study aims to evaluate the performance of ARFI in noninvasive assessment of the tissue stiffness of focal liver lesion (FLL) and to explore its potential value in the differential diagnosis of FLL. METHODS: ARFI was performed in 140 patients with 154 FLLs, which included 28 hemangiomas (ANGIs), 14 focal nodular hyperplasias (FNHs), 61 hepatocellular carcinomas (HCCs), 39 metastases and 12 cholangiocellular carcinomas (CCCs). Virtual touch tissue quantification (VTTQ) values were obtained, analyzed and compared. The area under the receiver operating characteristic curve (AUROC) and optimal cut-off values were obtained using a receiver operating characteristic (ROC) curve analysis to assess diagnostic performance. All cases were definitively diagnosed using histopathology, CT, MRI or contrast-enhanced ultrasound. RESULTS: The VTTQ median values of ANGI, FNH, HCC metastasis and CCC were 1.30, 1.80, 2.52, 3.08 and 3.89 m/s respectively. A significant increase in the VTTQ values of different lesions was observed: ANGI【FNH【HCC【metastasis 【CCC (P【0.001). The AUROC (95% CI) of VTTQ values was 0.94 (0.90-0.98) for ANGI, 0.91 (0.87-0.96) for malignant lesions and 0.87 (0.79-0.94) for CCC. The sensitivity and specificity for ANGI (86.5%, 89.3%, respectively), malignancy (81.3% 92.9%, respectively), and CCC (91.7%, 72.5%, respectively) were associated with VTTQ cut-off values of 1.76, 2.22 and 3.00 m/s respectively.CONCLUSIONS: ARFI can accurately and objectively assess the elasticity of lesions by obtaining the shear wave elastic value of FLL with VTTQ. Therefore, ARFI is a novel, simple, noninvasive and useful diagnostic method for the characterization of FLL. 展开更多
关键词 acoustic radiation force impulse imaging elastosonography focal liver lesion
下载PDF
Post-hepatoportoenterostomy Acoustic Radiation Force Impulse Elastography to Predict Two-year Outcome of Biliary Atresia
3
作者 Dongying Zhao Yahui Li +3 位作者 Wei Xie Wenjie Wu Yan Chen Yongjun Zhang 《Journal of Clinical and Translational Hepatology》 SCIE 2023年第3期595-604,共10页
Background and Aims: Early identification of prognostic factors to predict transplant/death outcome of biliary atresia (BA) is challenging. We aimed to investigate the longitudinal changes and predictive value of dyna... Background and Aims: Early identification of prognostic factors to predict transplant/death outcome of biliary atresia (BA) is challenging. We aimed to investigate the longitudinal changes and predictive value of dynamic changes in acoustic radiation force impulse elastography with shear wave speed (SWS) quantification and other parameters within three months after hepatoportoenterostomy (HPE) for 2-year BA outcomes. Methods: Seventy-four patients who underwent HPE between July 2016 and June 2019 were prospectively enrolled. Outcomes were classified into native liver survival and transplant/death groups. Acoustic radiation force im-pulse elastography was performed sequentially at 3 months intervals post-HPE. Cox regression analysis was used to de-termine the superior SWS values and other predictors of liver transplantation or death. Results: Among patients 2 years of age, 36 survived with a native liver, nine died, and 29 underwent liver transplantation. The trend in SWS levels in the transplant/death group was significantly different from that in the native liver survival group. ΔSWS at 1-3 months post-HPE and total bilirubin at 1 month post-HPE were se-lected as superior predictors of liver transplantation or death using multivariate Cox regression models: hazard ratio (HR)=1.927;95% confidence interval (CI): 1.475-2.661;p<0.001 and HR=1.010;95% CI: 1.003-1.017;p=0.007, respectively. The combination of the selected ΔSWS and total bilirubin had good predictive power, with an area under the receiver operating characteristics curve of 0.89, specificity 94.44% and sensitivity 73.68%. Conclusions: Our results suggest that early postoperative bilirubin levels and SWS changes were reliable predictors of 2-year BA outcomes. 展开更多
关键词 Biliary atresia Hepatoportoenterostomy acoustic radiation force impulse elastography Native liver survival Liver transplantation.
原文传递
Comparison of Rehabilitation Outcomes with Acoustic Radiation Force (ARFI) Elastosonography in Hemiplegic Patients Treated with Neuromuscular Electrical Stimulation
4
作者 Murat Toprak Nursen Toprak 《Open Journal of Therapy and Rehabilitation》 2019年第1期1-11,共11页
To evaluate the gastrocnemius/soleus and biceps brachii muscle stiffness by Acoustic Radiation Force Impulse (ARFI) elastography in the hemiplegia patients, sixty patients with hemiplegia after stroke were recruited. ... To evaluate the gastrocnemius/soleus and biceps brachii muscle stiffness by Acoustic Radiation Force Impulse (ARFI) elastography in the hemiplegia patients, sixty patients with hemiplegia after stroke were recruited. Baseline data were collected including age, gender, body mass index, education level, dominant side, affected side, time since stroke, stroke etiology. All patients were evaluated with before treatment and posttreatment with Broonstroom staging, Modified Ashworth spasticity scale, and Functional Independence Measures scale. The patient was divided into 3 groups: 1) Neuromuscular electrical stimulation group, 2) Rehabilitation group, 3) Neurumusculer electrical stimulation + Rehabilitation group. Affected and unaffected side biceps and gastrocnemius, ARFI elastography measurements were used to measure thickness and elastic values. In addition, before and after treatment, length and thickness were measured from all patients. Of the 60 subjects, 28 were female (46.7%) and 32 (53.3%) were males, with an average age of 58.42 ± 9.03 years. There was a significant difference between the upper and lower limbs after the treatment in terms of Brunstroom staging. In terms of Modified Ashworth scale, there was a significant difference in lower extremity only after treatment. When compared to the affected/unaffected side, before and after treatment, there was a significant difference in the measurements in both the medial gastrocnemius and the lateral gastrocnemius in all three groups. Further research with larger numbers of patients for longer periods is needed to clarify the relationship between the muscle hardness and degree of spasticity. 展开更多
关键词 HEMIPLEGIA REHABILITATION acoustic radiation force impulse ELASTOGRAPHY Electrical Stimulation
下载PDF
Application of ultrasonography-elastography score to suspect porto-sinusoidal vascular disease in patients with portal vein thrombosis
5
作者 Stefania Gioia Adriano De Santis +5 位作者 Giulia d’Amati Silvia Nardelli Alessandra Spagnoli Arianna Di Rocco Lorenzo Ridola Oliviero Riggio 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第1期20-24,共5页
Background:Porto-sinusoidal vascular disease(PSVD)and portal vein thrombosis(PVT)are causes of portal hypertension characterized respectively by an intrahepatic and a pre-hepatic obstacle to the flow in the portal sys... Background:Porto-sinusoidal vascular disease(PSVD)and portal vein thrombosis(PVT)are causes of portal hypertension characterized respectively by an intrahepatic and a pre-hepatic obstacle to the flow in the portal system.As PVT may be a consequence of PSVD,in PVT patients at presentation,a pre-existing PSVD should be suspected.In these patients the identification of an underlying PSVD would have relevant implication regarding follow-up and therapeutic management,but it could be challenging.In this setting ultrasonography may be valuable in differential diagnosis.The aim of the study was to use ultrasonography to identify parameters to discriminate between PSVD and“pure”PVT and then to suspect PVT secondary to a pre-existing PSVD.Methods:Fifty-three patients with histologically proven PSVD and forty-eight patients affected by chronic PVT were enrolled and submitted to abdominal ultrasonography with elastography by acoustic radiation force impulse(ARFI).Results:ARFI was higher and superior mesenteric vein(SMV)diameter was wider in PSVD patients than in PVT patients.Thus,a prognostic score was obtained as linear combinations of the two parameters with a good discrimination capacity between PSVD and PVT(the area under the curve=0.780;95%confidence interval:0.690-0.869).Conclusions:A score based on ARFI and SMV diameter may be useful to suspect an underlying PSVD in patients with PVT and to identify a subgroup of patients to be submitted to liver biopsy. 展开更多
关键词 Non-cirrhotic portal hypertension Porto-sinusoidal vascular disease Chronic portal vein thrombosis Liver stiffness Portal hypertension acoustic radiation force impulse
下载PDF
Shear wave velocity is a useful marker for managing nonalcoholic steatohepatitis 被引量:30
6
作者 Akihiko Osaki Tomoyuki Kubota +11 位作者 Takeshi Suda Masato Igarashi Keisuke Nagasaki Atsunori Tsuchiya Masahiko Yano Yasushi Tamura Masaaki Takamura Hirokazu Kawai Satoshi Yamagiwa Toru Kikuchi Minoru Nomoto Yutaka Aoyagi 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第23期2918-2925,共8页
AIM:To investigate whether a noninvasive measurement of tissue strain has a potential usefulness for management of nonalcoholic steatohepatitis(NASH).METHODS:In total 26 patients,23 NASHs and 3 normal controls were en... AIM:To investigate whether a noninvasive measurement of tissue strain has a potential usefulness for management of nonalcoholic steatohepatitis(NASH).METHODS:In total 26 patients,23 NASHs and 3 normal controls were enrolled in this study.NASH was staged based on Brunt criterion.At a region of interest(ROI),a shear wave was evoked by implementing an acoustic radiation force impulse(ARFI),and the propagation velocity was quantif ied.RESULTS:Shear wave velocity(SWV) could be reproducibly quantified at all ROIs in all subjects except for 4 NASH cases,in which a reliable SWV value was not calculated at several ROIs.An average SWV of 1.34 ± 0.26 m/s in fibrous stage 0-1 was significantly slower than 2.20 ± 0.74 m/s and 2.90 ± 1.01 m/s in stages 3 and 4,respectively,but was not significantly different from 1.79 ± 0.78 m/s in stage 2.When a cutoff value was set at 1.47 m/s,receiver operating characteristic analysis showed significance to dissociate stages 3 and 4 from stage 0-1(P=0.0092) with sensitivity,specificity and area under curve of 100%,75% and 94.2%,respectively.In addition,the correlation between SWV and hyaluronic acid was significant(P<0.0001),while a tendency toward negative correlation was observed with serum albumin(P=0.053).CONCLUSION:The clinical implementation of ARFI provides noninvasive repeated evaluations of liver stiffness at an arbitrary position,which has the potential to shed new light on NASH management. 展开更多
关键词 Nonalcoholic steatohepatitis ULTRASOUND Liver stiffness measurement Shear wave velocity acoustic radiation force impulse
下载PDF
Ultrasound-based elastography for the diagnosis of portal hypertension in cirrhotics 被引量:6
7
作者 Roxana Sirli Ioan Sporea +1 位作者 Alina Popescu Mirela Danila 《World Journal of Gastroenterology》 SCIE CAS 2015年第41期11542-11551,共10页
Progressive fibrosis is encountered in almost all chronicliver diseases. Its clinical signs are diagnostic in advanced cirrhosis, but compensated liver cirrhosis is harder to diagnose. Liver biopsy is still considered... Progressive fibrosis is encountered in almost all chronicliver diseases. Its clinical signs are diagnostic in advanced cirrhosis, but compensated liver cirrhosis is harder to diagnose. Liver biopsy is still considered the reference method for staging the severity of fibrosis, but due to its drawbacks(inter and intra-observer variability, sampling errors, unequal distribution of fibrosis in the liver, and risk of complications and even death), non-invasive methods were developed to assess fibrosis(serologic and elastographic). Elastographic methods can be ultrasound-based or magnetic resonance imaging-based. All ultrasoundbased elastographic methods are valuable for the early diagnosis of cirrhosis, especially transient elastography(TE) and acoustic radiation force impulse(ARFI) elastography, which have similar sensitivities and specificities, although ARFI has better feasibility. TE is a promising method for predicting portal hypertension in cirrhotic patients, but it cannot replace upper digestive endoscopy. The diagnostic accuracy of using ARFI in the liver to predict portal hypertension in cirrhotic patients is debatable, with controversial results in published studies. The accuracy of ARFI elastography may be significantly increased if spleen stiffness is assessed, either alone or in combination with liver stiffness and other parameters. Two-dimensional shearwave elastography, the Elast PQ technique and strain elastography all need to be evaluated as predictors of portal hypertension. 展开更多
关键词 Portal hypertension Transient elastography acoustic radiation force impulse elastography Two-dimensional shear-wave elastography
下载PDF
Evaluation of kidney allograft status using novel ultrasonic technologies 被引量:1
8
作者 Cheng Yang Mushuang Hu +1 位作者 Tongyu Zhu Wanyuan He 《Asian Journal of Urology》 2015年第3期142-150,共9页
Early diagnosis of kidney allograft injury contributes to proper decisions regarding treatment strategy and promotes the long-term survival of both the recipients and the allografts.Although biopsy remains the gold st... Early diagnosis of kidney allograft injury contributes to proper decisions regarding treatment strategy and promotes the long-term survival of both the recipients and the allografts.Although biopsy remains the gold standard,non-invasive methods of kidney allograft evaluation are required for clinical practice.Recently,novel ultrasonic technologies have been applied in the evaluation and diagnosis of kidney allograft status,including tissue elasticity quantification using acoustic radiation force impulse(ARFI)and contrast-enhanced ultrasonography(CEUS).In this review,we discuss current opinions on the application of ARFI and CEUS for evaluating kidney allograft function and their possible influencing factors,advantages and limitations.We also compare these two technologies with other non-invasive diagnostic methods,including nuclear medicine and radiology.While the role of novel non-invasive ultrasonic technologies in the assessment of kidney allografts requires further investigation,the use of such technologies remains highly promising. 展开更多
关键词 ULTRASOUND acoustic radiation force impulse Contrast-enhanced ultrasonography Kidney transplantation NON-INVASIVE
下载PDF
Comparison of point and two-dimensional shear wave elastography of the spleen in healthy subjects 被引量:1
9
作者 Friederike Nowotny Julian Schmidberger +2 位作者 Patrycja Schlingeloff Andreas Binzberger Wolfgang Kratzer 《World Journal of Radiology》 2021年第5期137-148,共12页
BACKGROUND Few systematic comparative studies of the different methods of physical elastography of the spleen are currently available.AIM To compare point shear wave and two-dimensional elastography of the spleen cons... BACKGROUND Few systematic comparative studies of the different methods of physical elastography of the spleen are currently available.AIM To compare point shear wave and two-dimensional elastography of the spleen considering the anatomical location(upper,hilar,and lower pole).METHODS As part of a prospective clinical study,healthy volunteers were examined for splenic elasticity using four different ultrasound devices between May 2015 and April 2017.The devices used for point shear wave elastography were from Siemens(S 3000)and Philips(Epiq 7),and those used for two-dimensional shear wave elastography were from GE(Logiq E9)and Toshiba(Aplio 500).In addition,two different software versions(5.0 and 6.0)were evaluated for the Toshiba ultrasound device(Aplio 500).The study consisted of three arms:A,B,and C.RESULTS In study arm A,200 subjects were evaluated(78 males and 122 females,mean age 27.9±8.1 years).In study arm B,113 subjects were evaluated(38 men and 75 women,mean age 26.0±6.3 years).In study arm C,44 subjects were enrolled.A significant correlation of the shear wave velocities at the upper third of the spleen(r=0.33088,P<0.0001)was demonstrated only for the Philips Epiq 7 device compared to the Siemens Acuson S 3000.In comparisons of the other ultrasound devices(GE,Siemens,Toshiba),no comparable results could be obtained for any anatomical position of the spleen.The influencing factors age,gender,and body mass index did not show a clear correlation with the measured shear wave velocities.CONCLUSION The absolute values of the shear wave elastography measurements of the spleen and the two different elastography methods are not comparable between different manufacturers or models. 展开更多
关键词 ULTRASONOGRAPHY ELASTOGRAPHY SPLEEN Healthy subjects acoustic radiation force impulse Two-dimensional shear-wave elastography Point shear wave elastography
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部