The persistence of left superior vena cava (PLSVC) is the most common congenital anomaly of the venous return system to the heart. Because of the increasing number of patients referred for cardiac resynchronization th...The persistence of left superior vena cava (PLSVC) is the most common congenital anomaly of the venous return system to the heart. Because of the increasing number of patients referred for cardiac resynchronization therapy (CRT) devices implantations, it is expected to encounter this venous anatomic variation. Left ventricular lead placement at an appropriate site is an integral and technically challenging part of successful CRT. In case of cardiac abnormalities could be difficult to achieve an optimal cardiac rhythm management devices implantation. Previous reports in patients with PLSVC highlighted the challenges to achieve an optimal cardiac rhythm device implantation. Recently, a new quadripolar active fixation left ventricular lead is available for CRT device implantation. Hereby we report a case of a device upgrading from dual-chamber pacemaker to CRT with defibrillator backup using the active fixation left ventricular quadripolar lead in a patient with PLSVC and right superior vena cava atresia.展开更多
We describe the case of a 77-year-old female who underwent dual-chamber permanent pacemaker implantation using two active screw-in leads for complete atrioventricular block. The two active screw-in leads perforated th...We describe the case of a 77-year-old female who underwent dual-chamber permanent pacemaker implantation using two active screw-in leads for complete atrioventricular block. The two active screw-in leads perforated the atrial and ventricular walls causing cardiac tamponade and a left hemothorax associated with ventricular perforation. An emergency sternotomy was performed to facilitate drainage and hemostasis. Although hemothorax due to pacing lead perforation is very rare, such a possibility should always be considered.展开更多
文摘The persistence of left superior vena cava (PLSVC) is the most common congenital anomaly of the venous return system to the heart. Because of the increasing number of patients referred for cardiac resynchronization therapy (CRT) devices implantations, it is expected to encounter this venous anatomic variation. Left ventricular lead placement at an appropriate site is an integral and technically challenging part of successful CRT. In case of cardiac abnormalities could be difficult to achieve an optimal cardiac rhythm management devices implantation. Previous reports in patients with PLSVC highlighted the challenges to achieve an optimal cardiac rhythm device implantation. Recently, a new quadripolar active fixation left ventricular lead is available for CRT device implantation. Hereby we report a case of a device upgrading from dual-chamber pacemaker to CRT with defibrillator backup using the active fixation left ventricular quadripolar lead in a patient with PLSVC and right superior vena cava atresia.
文摘We describe the case of a 77-year-old female who underwent dual-chamber permanent pacemaker implantation using two active screw-in leads for complete atrioventricular block. The two active screw-in leads perforated the atrial and ventricular walls causing cardiac tamponade and a left hemothorax associated with ventricular perforation. An emergency sternotomy was performed to facilitate drainage and hemostasis. Although hemothorax due to pacing lead perforation is very rare, such a possibility should always be considered.