The high proportion of nonlinear and unbalanced loads results in power quality issues in islanded microgrids.This paper presents a novel control strategy for harmonic and unbalanced power allocation among distributed ...The high proportion of nonlinear and unbalanced loads results in power quality issues in islanded microgrids.This paper presents a novel control strategy for harmonic and unbalanced power allocation among distributed genera-tors(DGs)in microgrids.Different from the existing sharing strategies that allocate the harmonic and unbalanced power according to the rated capacities of DGs,the proposed control strategy intends to shape the lowest output impedances of DGs to optimize the power quality of the microgrid.To achieve this goal,the feasible range of virtual impedance is analyzed in detail by eigenvalue analysis,and the findings suggest a simultaneous adjustment of real and imaginary parts of virtual impedance.Because virtual impedance is an open-loop control that imposes DG to the risk of overload,a new closed-loop structure is designed that uses residual capacity and absorbed power as feedback.Accordingly,virtual impedance can be safely adjusted in the feasible range until the power limit is reached.In addi-tion,a fuzzy integral controller is adopted to improve the dynamics and convergence of the power distribution,and its performance is found to be superior to linear integral controllers.Finally,simulations and control hardware-in-the-loop experiments are conducted to verify the effectiveness and usefulness of the proposed control strategy.展开更多
The effects of nonlinear loads on voltage quality represent an emerging concern for islanded microgrids.Existing research works have mainly focused on harmonic power sharing among multiple inverters,which ignores the ...The effects of nonlinear loads on voltage quality represent an emerging concern for islanded microgrids.Existing research works have mainly focused on harmonic power sharing among multiple inverters,which ignores the diversity of different inverters to mitigate harmonics from nonlinear loads.As a result,the voltage quality of microgrids cannot be effectively improved.To address this issue,this study proposes an adaptive harmonic virtual impedance(HVI)control for improving voltage quality of microgrids.Based on the premise that no inverter is overloaded,the main objective of the proposed control is to maximize harmonic power absorption by shaping the lowest output impedances of inverters.To achieve this,the proposed control is utilized to adjust the HVI of each inverter based on its operation conditions.In addition,the evaluation based on Monte Carlo harmonic power flow is designed to assess the performance of the proposed control in practice.Finally,comparative studies and control-in-the-loop experiments are conducted.展开更多
基金supported by the Science and Technology Project of SGCC under grant 5400-202219417A-2-0-ZN.
文摘The high proportion of nonlinear and unbalanced loads results in power quality issues in islanded microgrids.This paper presents a novel control strategy for harmonic and unbalanced power allocation among distributed genera-tors(DGs)in microgrids.Different from the existing sharing strategies that allocate the harmonic and unbalanced power according to the rated capacities of DGs,the proposed control strategy intends to shape the lowest output impedances of DGs to optimize the power quality of the microgrid.To achieve this goal,the feasible range of virtual impedance is analyzed in detail by eigenvalue analysis,and the findings suggest a simultaneous adjustment of real and imaginary parts of virtual impedance.Because virtual impedance is an open-loop control that imposes DG to the risk of overload,a new closed-loop structure is designed that uses residual capacity and absorbed power as feedback.Accordingly,virtual impedance can be safely adjusted in the feasible range until the power limit is reached.In addi-tion,a fuzzy integral controller is adopted to improve the dynamics and convergence of the power distribution,and its performance is found to be superior to linear integral controllers.Finally,simulations and control hardware-in-the-loop experiments are conducted to verify the effectiveness and usefulness of the proposed control strategy.
基金supported by the Science and Technology Project of State Grid Corporation of China(No.5400-202219417A-2-0-ZN)。
文摘The effects of nonlinear loads on voltage quality represent an emerging concern for islanded microgrids.Existing research works have mainly focused on harmonic power sharing among multiple inverters,which ignores the diversity of different inverters to mitigate harmonics from nonlinear loads.As a result,the voltage quality of microgrids cannot be effectively improved.To address this issue,this study proposes an adaptive harmonic virtual impedance(HVI)control for improving voltage quality of microgrids.Based on the premise that no inverter is overloaded,the main objective of the proposed control is to maximize harmonic power absorption by shaping the lowest output impedances of inverters.To achieve this,the proposed control is utilized to adjust the HVI of each inverter based on its operation conditions.In addition,the evaluation based on Monte Carlo harmonic power flow is designed to assess the performance of the proposed control in practice.Finally,comparative studies and control-in-the-loop experiments are conducted.