Ag/AgCl electrode has been prepared using pressed powder techniques. In order to verify the feasibility of this type of electrode used as detecting electric field generated by vessels in seawater, its characteristics ...Ag/AgCl electrode has been prepared using pressed powder techniques. In order to verify the feasibility of this type of electrode used as detecting electric field generated by vessels in seawater, its characteristics of DC resistance, low frequency AC impedance, and receiving impedance in artificial seawater have been studied by polarization measurements, low frequency electrochemical impedance spectra, the open and short circuit cell conditions. The results show that the electrode can keep a low resistance when it responses the weak electrostatic field in seawater. The AC impedance of the electrode decreases as the frequency of the signal increasing. The receiving impedance decreases when the frequency of external field increases too. The valid detection bandwidth is determined by the properties of the impedance and the reactions occurring on the surface of the electrode.展开更多
The tremendous potential of triboelectric generators-TENGs for converting mechanical energy into electrical energy places them as one of the most promising energy harvesting technologies. In this work, the fabrication...The tremendous potential of triboelectric generators-TENGs for converting mechanical energy into electrical energy places them as one of the most promising energy harvesting technologies. In this work, the fabrication of enhanced performance TENGs using Ag octahedron nano-assemblies on ITO as electrodes significantly increases the electric charge collection of the induced tribocharges. Thereby, nanostructured electrical contacts coated with Ag macroscale nano-assemblies with octahedral features were obtained by the electrodeposition technique on flexible PET/ITO substrates. Consequently, the nanostructured triboelectric generator-TENG exhibited 65 times more maximum output power, and almost 10 times more open circuit output voltage than that of a TENG with non-nanostructured contacts passing from μW to m W capabilities, which was attributed to the increment of intrinsic interface states due to a higher effective contact area in the former. Likewise, output performances of TENGs also displayed an asymptotic behavior on the output voltage as the operating frequency of the mechanical oscillations increased, which is attributed to a decrement in the internal impedance of the device with frequency. Furthermore, it is shown that the resulting electrical output power can successfully drive low power consumption electronic devices. On that account, the present research establishes a promising platform which contributes in an original way to the development of the TENGs technology.展开更多
We put forward a method of rapid preparation of chloride selective electrode(Ag/AgCl electrode) by dipping silver wire into sodium hypochlorite solution. The electrodes were prepared through different immersion time...We put forward a method of rapid preparation of chloride selective electrode(Ag/AgCl electrode) by dipping silver wire into sodium hypochlorite solution. The electrodes were prepared through different immersion time. The properties of the electrodes, such as Nernst response, response time and longterm stability, were tested in simulated concrete pore solutions(SCPS). Moreover, the surface morphology of the electrodes was also detected after immersion in solutions over three months. The experimental results reveal that the Ag/AgCl electrode with the fabrication time of 20 minutes(E-20) which is recommended to work as the chloride ion selective electrode has the best performance. Compared to that fabricated by the electrolytic process(E-EP), E-20 can be manufactured in mass. The method has almost the same good performance of Nernst response as E-EP, and has a better response time which is less than 25 seconds. The method also shows a better good long-term stability in SCPS containing chloride ions over three months.展开更多
The most common reference electrode (RE) which is used in electrochemical measurements is the Ag/AgCl electrode. In this study, we present a novel solid-state Ag/AgCl planar electrode that was coated with a thin layer...The most common reference electrode (RE) which is used in electrochemical measurements is the Ag/AgCl electrode. In this study, we present a novel solid-state Ag/AgCl planar electrode that was coated with a thin layer of Graphite Oxide (GO) as a protective layer. The Ag/AgCl planar electrode was fabricated by using the photolithography and lift-off method combined with the Ag[NH3]2Cl complex. The GO was produced by Hummer’s method and was deposited on top of the Ag/AgCl layer by drop-casting method. The layers of the fabricated reference electrode were characterized by micro Raman spectroscopy, Scanning Electron Microscopy (SEM) and Energy-dispersive X-ray spectroscopy (EDX). The responding time of the planar electrode was short and the signal was more stable in comparison to the plainAg/AgCl electrode. The Open Circuit Potential (OCP) measurement with the fabricated electrode as the RE and the platinum electrode as the working electrode in electrolyte solutions which had various pH values was performed with a linear response in pH ranges from pH 5 to pH 8 and the linear correlation coefficient (R^2 = 0.9899). Moreover, the coating of the GO layers also enhanced the durability of the modified electrode. The results showed that the modified Ag/AgCl electrode with a thin layer GO as the protective layer could be used as plana REs for the potentiometric sensors.展开更多
Reference electrodes are a key part for corrosion monitoring and measurement of rebars in concrete. A reference electrode that can be buried in concrete is fabricated by using Ag/Ag Cl electrode and methyl cellulose g...Reference electrodes are a key part for corrosion monitoring and measurement of rebars in concrete. A reference electrode that can be buried in concrete is fabricated by using Ag/Ag Cl electrode and methyl cellulose gelling electrolyte. The stability, repeatability and anti-polarization of the reference electrode are investigated; the influences of the inner electrolyte loss, exterior OH- contamination, and temperature on the potential of the reference electrode are also investigated in this paper. The results show that the reference electrode has good stability, repeatability, and antipolarization. The influences of inner electrolyte loss, exterior OH- contamination, and temperature on the potential of the reference electrode are minimal. Therefore, it can be used for corrosion monitoring and measurement of rebars in concrete.展开更多
The behavior of chloride adsorbed on Ag(100) electrode has been studied using chronoamperometric technique, and the structural transition of chloride layer has been confirmed.
In this paper,the voltammetric behaviours of Ag cylinder electrode in 1 mol/dm(3) KOH solution have been investigated in the presence of ultrasound irradiation. The results based on the CV, EIS and polarization measur...In this paper,the voltammetric behaviours of Ag cylinder electrode in 1 mol/dm(3) KOH solution have been investigated in the presence of ultrasound irradiation. The results based on the CV, EIS and polarization measurements showed that ultrasound could enhance the mass transport, inhibit the oxygen evolution and increase the exchange current.展开更多
文摘Ag/AgCl electrode has been prepared using pressed powder techniques. In order to verify the feasibility of this type of electrode used as detecting electric field generated by vessels in seawater, its characteristics of DC resistance, low frequency AC impedance, and receiving impedance in artificial seawater have been studied by polarization measurements, low frequency electrochemical impedance spectra, the open and short circuit cell conditions. The results show that the electrode can keep a low resistance when it responses the weak electrostatic field in seawater. The AC impedance of the electrode decreases as the frequency of the signal increasing. The receiving impedance decreases when the frequency of external field increases too. The valid detection bandwidth is determined by the properties of the impedance and the reactions occurring on the surface of the electrode.
基金Consejo Nacional de Ciencia y Tecnología of México (CONACYT) for her Doctoral scholarshippostgraduate studies department at CIMAVMonterrey for fellowship support。
文摘The tremendous potential of triboelectric generators-TENGs for converting mechanical energy into electrical energy places them as one of the most promising energy harvesting technologies. In this work, the fabrication of enhanced performance TENGs using Ag octahedron nano-assemblies on ITO as electrodes significantly increases the electric charge collection of the induced tribocharges. Thereby, nanostructured electrical contacts coated with Ag macroscale nano-assemblies with octahedral features were obtained by the electrodeposition technique on flexible PET/ITO substrates. Consequently, the nanostructured triboelectric generator-TENG exhibited 65 times more maximum output power, and almost 10 times more open circuit output voltage than that of a TENG with non-nanostructured contacts passing from μW to m W capabilities, which was attributed to the increment of intrinsic interface states due to a higher effective contact area in the former. Likewise, output performances of TENGs also displayed an asymptotic behavior on the output voltage as the operating frequency of the mechanical oscillations increased, which is attributed to a decrement in the internal impedance of the device with frequency. Furthermore, it is shown that the resulting electrical output power can successfully drive low power consumption electronic devices. On that account, the present research establishes a promising platform which contributes in an original way to the development of the TENGs technology.
基金the National Key Technology Research and Development Program of the Ministry of Science and Technology of China(2015BAB07B04)the Natural Science Foundation of China(51278167)the Fundamental Research Funds for the Central Universities(2016B04514)
文摘We put forward a method of rapid preparation of chloride selective electrode(Ag/AgCl electrode) by dipping silver wire into sodium hypochlorite solution. The electrodes were prepared through different immersion time. The properties of the electrodes, such as Nernst response, response time and longterm stability, were tested in simulated concrete pore solutions(SCPS). Moreover, the surface morphology of the electrodes was also detected after immersion in solutions over three months. The experimental results reveal that the Ag/AgCl electrode with the fabrication time of 20 minutes(E-20) which is recommended to work as the chloride ion selective electrode has the best performance. Compared to that fabricated by the electrolytic process(E-EP), E-20 can be manufactured in mass. The method has almost the same good performance of Nernst response as E-EP, and has a better response time which is less than 25 seconds. The method also shows a better good long-term stability in SCPS containing chloride ions over three months.
文摘The most common reference electrode (RE) which is used in electrochemical measurements is the Ag/AgCl electrode. In this study, we present a novel solid-state Ag/AgCl planar electrode that was coated with a thin layer of Graphite Oxide (GO) as a protective layer. The Ag/AgCl planar electrode was fabricated by using the photolithography and lift-off method combined with the Ag[NH3]2Cl complex. The GO was produced by Hummer’s method and was deposited on top of the Ag/AgCl layer by drop-casting method. The layers of the fabricated reference electrode were characterized by micro Raman spectroscopy, Scanning Electron Microscopy (SEM) and Energy-dispersive X-ray spectroscopy (EDX). The responding time of the planar electrode was short and the signal was more stable in comparison to the plainAg/AgCl electrode. The Open Circuit Potential (OCP) measurement with the fabricated electrode as the RE and the platinum electrode as the working electrode in electrolyte solutions which had various pH values was performed with a linear response in pH ranges from pH 5 to pH 8 and the linear correlation coefficient (R^2 = 0.9899). Moreover, the coating of the GO layers also enhanced the durability of the modified electrode. The results showed that the modified Ag/AgCl electrode with a thin layer GO as the protective layer could be used as plana REs for the potentiometric sensors.
基金financially supported by the National Science and Technology Support Program of China(Grant No.2011BAG07B04)
文摘Reference electrodes are a key part for corrosion monitoring and measurement of rebars in concrete. A reference electrode that can be buried in concrete is fabricated by using Ag/Ag Cl electrode and methyl cellulose gelling electrolyte. The stability, repeatability and anti-polarization of the reference electrode are investigated; the influences of the inner electrolyte loss, exterior OH- contamination, and temperature on the potential of the reference electrode are also investigated in this paper. The results show that the reference electrode has good stability, repeatability, and antipolarization. The influences of inner electrolyte loss, exterior OH- contamination, and temperature on the potential of the reference electrode are minimal. Therefore, it can be used for corrosion monitoring and measurement of rebars in concrete.
基金We are greateful to the National Narural Science Foundation of China(No.20455017)Science and Technology Committee of Shanghai Municipal(No.0452nm084).
文摘The behavior of chloride adsorbed on Ag(100) electrode has been studied using chronoamperometric technique, and the structural transition of chloride layer has been confirmed.
文摘In this paper,the voltammetric behaviours of Ag cylinder electrode in 1 mol/dm(3) KOH solution have been investigated in the presence of ultrasound irradiation. The results based on the CV, EIS and polarization measurements showed that ultrasound could enhance the mass transport, inhibit the oxygen evolution and increase the exchange current.